• Title/Summary/Keyword: Mandibular position

Search Result 546, Processing Time 0.028 seconds

EVALUATION OF CONDYLAR DISPLACEMENT USING COMPUTER TOMOGRAPHY AFTER THE SURGICAL CORRECTION OF MANDIBULAR PROGNATHISM (전산화단층촬영법을 이용한 하악전돌증 환자의 외과적 악교정술후 하악과두 위치 변화 검토)

  • Lee, Ho-Kyung;Jang, Hyun-Jung;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.3
    • /
    • pp.191-200
    • /
    • 1998
  • This study was intended to perform the influence of condyle positional change after surgical correction of skeletal Class III malocclusion after orthognathic surgery in 37 patients(male 13, female 24) using computed tomogram that were taken in centric occlusion before, immediate after, and long term after surgery and lateral cephalogram that were taken in centric occlusion before, 7 days within the period of intermaxillary fixation, at the 24 hours later removing intermaxillary fixation and long term after surgery. 1. Mean intercondylar distance was $84.42{\pm}5.30mm$ and horizontal long axis of condylar angle was $12.79{\pm}4.92^{\circ}$ on the right, $13.53{\pm}5.56^{\circ}$ on the left side. Condylar lateral poles were located about 12mm and medial poles about 7mm away from the reference line(AA') on the axial tomogram. Mean intercondylar distance was $83.15{\pm}4.62mm$ and vertical axis angle of condylar angle was $76.28{\pm}428^{\circ}$ on the right, $78.30{\pm}3.79^{\circ}$ on the left. 2. In amount of set back, We found the condylar change(T2C-T1C) which had increasing tendency in group III (amount of setback : 10-15mm). but there was no statistical significance(p>0.05). 3. There was some correlation between condylar change(T2C-T1C) and TMJ dysfunction. It seemed that postoperative condylar change had influenced postoperative TMJ dysfunction, through there was no statistical significance (p>0.05). As we have observed the change of condylar axis in the group that complained of TMJ dysfunction in cases of large amount of mandibular setback. So we consider that the more trying to conserve condylar position will decrease occurrence rate of post operational TMJ dysfunction.

  • PDF

A CEPHALOMETRIC STUDY ON THE AIRWAY SIZE ACCORDING TO THE TYPES OF THE MALOCCLUSION (부정교합 유형에 따른 기도의 크기)

  • Lee, Yong-Seung;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.25 no.1 s.48
    • /
    • pp.19-29
    • /
    • 1995
  • This study was performed to compare the size of soft palate, tongue and airway according to the types of the malocclusion and evaluate the correlation between the size of soft palate, tongue, airway and dentofacial skeleton respectively. The sample of this study was 98 malocclusion female patients between the ages 12 and 17 years. The lateral cephalometric radiographs were taken and the distance, angle, ratio and area of the dentofacial skeleton, soft palate, tongue and airway were measured and evaluated statistically. The results obtained were as follows: 1. There was significant difference in SNB, ANB, facial angle, facial convexity, A-B plane angel, Y axis to FH, SN-MP, Wits appraisal, ODI and APDI according to the types of malocclusion. 2. The hyoid bone was more posteriorly positioned in Class II malocclusion group than other two groups and superio-inferior position of the hyoid bone was not different according to the malocclusion types. 3. The nasopharyngeal area of Class II and Class III malocclusion group was smaller than that of Class I malocclusion group, and the pharyngeal area of Class II malocclusion group was smaller than that of Class I and Class III maocclusion group. There was no difference of the area of the soft palate, tongue, oropharynx and hypopharynx according to malocclusion types. 4. The ramal height and mandibular body length(Go-Me) showed positive correlation with the area of tongue, nasopharynx, oropharynx, and pharynx. SNA did not correlated with the area of tongue and airway but SNB showed positive correlation with the area of hypopharynx and pharynx. The anterior, posterior facial height, upper and lower central incisor position to facial plane showed positive correlation with tongue area.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE MANDIBULAR CANTILEVERED PROSTHESIS SUPPORTED BY IMPLANTS (임프란트로 지지된 하악 켄티레버 보철물의 3차원 유한요소 분석)

  • Cho, Chul;Shin, Sang-Wan;Kwon, Jong-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.724-743
    • /
    • 2000
  • One of the biggest clinical problems of osseointegrated implant prosthesis is the excessive stress caused by bite forces which are transfered directly into the bone through the osseointegrated implant fixtures. So several biodynamic problems occur when there is an excessive fatigue stress. The factors of stress distribution are the number, kind, position, arrangement of the implants, and the distance between the implants, and the kind, quality of superstructure prosthesis and connection type between the rest implant and the superstructure. Recently, a distal short additional implant, socalled rest implant, is employed to reduced the stresses in conventional cantilevered prostheses. This study was undertaken to analyze the stresses transfered by osseointegrated implant cantilevered prostheses depending upon the number and the position of implants, the presence of rest implant, and the type of their connection. Three dimensional finite element analysis was attempted using ANSIS ver. 5.3 program under IBM INDIGO computer. The results were as follows : 1. The rest implant influenced on the pattern of stress distribution on the anterior area of the mandible and the superstructure. 2. In the group employing the rest implants, the fixed type of connection between the rest implant and the superstructure was more stable than the ball attachment type on the stress distribution. 3. In the group employing the ball attachment between the rest implant and the superstructure, the case with 4-implants(on canine, premolar) was little more stable than the case with 6-implants and the case with 4-implants(on incisor, premolar) on the stress distribution. 4. In the cantilevered group, the case with 4-implants(on incisor, premolar) and the case with 6-implants were more stable than the case with 4-implants(on canine, premolar) on the stress distribution. 5. In all of the group, the case with 6-implants and the fixed type of connection was the most stable and the case with 4-implants (on canine, premolar) was the most unstable on the stress distribution.

  • PDF

Autotransplantation of Ectopically Impacted Teeth : Two Case Reports (이소매복된 치아의 자가치아이식 증례)

  • Lim, Yuran;Kim, Jaehwan;Choi, Namki;Kim, Seonmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.1
    • /
    • pp.108-115
    • /
    • 2017
  • Numerous therapeutic approaches are available for impacted teeth, including orthodontic retraction, implantation, and autogenous tooth transplantation. Autotransplantation is a promising method, especially for juvenile patients, as it enables preservation of the function of the periodontal tissues, as well as continued alveolar bone growth. This report describes autotransplantation in two cases in which the tooth was fully-ectopically impacted. With case 1, an ectopically impacted premolar was extracted and transplanted in an upright position, and regenerative endodontic treatment was performed using a platelet-rich fibrin clot and mineral trioxide aggregate (MTA). With case 2, a calcifying odontogenic cyst with an impacted left mandibular second molar was treated by enucleation. The tooth was transplanted into the proper position 3 months after enucleation, and endodontic treatment was performed using MTA. In both cases, autotransplantation appeared to provide a simple and rapid treatment option for patients with ectopically impacted teeth. These cases demonstrate that autotransplantation of ectopically impacted teeth is a viable treatment option rather than implant placement or prosthesis, especially in juvenile patients.

CEPHALOMETRIC PREDICTORS OF OBSTRUCTIVE SLEEP APNEA (폐쇄성 수면 무호흡증에 있어 두부 규격 방사선 계측학적 기여 인자)

  • Kwon, Tae-Geon;Cho, Yong-Won;Ahn, Byung-Hoon;Suh, Young-Sung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.5
    • /
    • pp.338-345
    • /
    • 2003
  • Purpose : This study was intended to perform cephalometric comparison between the patients with and without obstructive sleep apnea (OSA). The factors influencing the OSA in the lateral cephalogram was also investigated. Patient and Method : Twenty four patients who visited Sleep Disorder Clinic in Dongsan Medical Center, Keimyung University and evaluated with polysomnograph(PSG) and cephalogram were included in the study. The patients had apnea-hypopnea episode(AHI) over 10 times per hour was diagnosed as OSA after overnight PSG. To evaluate hard and soft tissue profile, cephalometric radiogram were taken at maximal intercuspation(P1) and mandibular protruding position(P2). The diffefence between the OSA and normal group were evaluated statistically and the stepwise regression analysis was applied to analyse the cephalometric influencing factors to OSA. Result : The OSA Group(n=14) had significantly higher Body Mass Index(BMI) than control group(n=10). Lower facial height(ANSGn) was longer in OSA group. However statistically significant difference was not detected in other anteroposterior craniofacial measurements. The soft palate lenth (PNS-P), hyoid position (MP-Hyoid) had positive correlation between AHI (r=0.496, r=0.413, respectively, p<0.05). However, the measurements of oropharyngeal airway was not different between the two groups. The hypothesis, the antero-posteriorly narrow oropharyngeal airway might aggravate the airway resistance and can give rise to higher AHI, was not accepted in the study. This can be attributed by inclusion of the patients performed uvulopalatopharyngoplasty because of the tonsilar or soft palate hypertrophy in the present study. The results of regression analysis revealed that PNS-P, upper airway width(Nph1), upper facial heght(N-ANS), and lower facial height(ANS-Gn) could influence the degree of AHI (F value < 0.0001, $R^2$ = 0.829). Conclusion : We suggest lateral cephalogram may utilized as a useful method to evaluate OSA. The patient with long soft palate, narrow upper airway width, long upper & lower facial height can be expected to have high risk of OSA. However, it should be emphasized the comphrehensive intraoral inspection including soft palate and tonsilar hypertrophy because lateral cepahlogram cannot visualize oropharyngeal status completely.

Esthetic Full Zirconia Fixed Detachable Implant-Retained Restorations Manufactured from Monolithic Zirconia : Clinical Report (Monolithic zirconia framework으로 제작된 fixed detachable prostheses를 이용한 심미적인 임플란트 전악 수복 증례)

  • Hong, Jun-Tae;Choi, Yu-Sung;Han, Se-Jin;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.253-268
    • /
    • 2012
  • Full-mouth reconstruction of a patient using dental implants is a challenge if there is vertical and horizontal bone resorption, since this includes the gingival area and restricts the position of the implants. however, hard- and soft-tissue grafting may allow the implants to be placed into the desired position. Although it is possible to regenerate lost tissues, an alternative is to use fixed detachable prostheses that restore the function and the esthetics of the gingiva and teeth. Various material combinations including metal/acrylic, metal/ceramic, and zirconia/ceramic have been used for constructing this type of restoration. Other problems include wear, separation or fracture of the resin teeth from the metal/acrylic prosthesis, chipping or fracture of porcelain from the metal/ceramic or zirconia/ceramic prosthesis, and fracture of the framework in some free-end prostheses. With virtually unbreakable, chip-proof, life-like nature, monolithic zirconia frameworks can prospectively replace other framework materials. This clinical report describes the restoration of a patient with complete fixed detachable maxillary and mandibular prostheses made of monolithic zirconia with dental implants. The occluding surfaces were made of monolithic zirconia, to decrease the risk of chipping or fracture. The prostheses were esthetically pleasing, and no clinical complications have been reported after two years.

Finite Element Stress Analysis of Implant Prosthesis according to Position and Direction of Load (하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소법적 응력분석)

  • Bae, Sook-Jin;Chung, Chae-Heon;Jeong, Seung-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.4
    • /
    • pp.257-268
    • /
    • 2003
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis according to position and direction of load, under vertical and inclined loading using FEA analysis. The finite element model was designed according to standard fixture (4.1mm restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric usp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant in both vertical and oblique loading but stresses in the cancellous bone were low in both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. 4. The relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 5. The magnitude of the stress in the supporting bone, fixture and abutment screw was greater with the outward oblique loading than with the inward oblique loading and was the greatest under loading at the centric cusp in a $30^{\circ}$ outward oblique direction. Conclusively, this study provides evidence that bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. But it seems to be more important that how long is the distance from center of rotation of the implant itself to the resultant line of force from occlusal contact(leverage). The goal of improving implants should be to avoid bending of the implant.

Assessment of Predicting Factors for Pediatric Sleep Disordered Breathing (소아 수면호흡장애의 예측 인자 평가)

  • Moon, Soyeon;Lee, Daewoo;Kim, Jaegon;Yang, Yeonmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.4
    • /
    • pp.377-388
    • /
    • 2020
  • The aim of this study was to evaluate the association between various predicting tools and Apnea-Hypopnea Index (AHI) to identify children with sleep disordered breathing (SDB). From 5 to 10 years old who came for orthodontic counseling, 61 children, whom had lateral cephalograms, pediatric sleep questionnaire (PSQ) records, and portable sleep monitoring results, were included in this study. A total of 17 measurements (11 distances and 6 angles) were made on lateral cephalograms. The measurements of lateral cephalograms, PSQ scales and portable sleep monitoring results were statistically analyzed. 49 of 61 (80%) patients showed AHI > 1, which suspected to have SDB and their mean AHI was 2.75. In this study, adenoid size (A/N ratio), position of the hyoid bone from mandibular plane, gonial angle, and PSQ scale were related to a higher risk of pediatric SDB. Also, oxygen desaturation index (ODI) and snoring time from sleep monitoring results were statistically significant in children with SDB using Mann-Whitney test (p < 0.05). In conclusion, evaluation of hyoid bone position, adenoidal hypertrophy, gonial angle in lateral cephalogram, and PSQ scale was important to screen out potential SDB, especially in children with frequent snoring.

Cephalometric Predisposing Factors of the Snoring and Obstructive Sleep Apnea (코골이 및 폐쇄성 수면 무호흡증의 두부 규격 방사선 계측학적 기여 인자)

  • Seo, Eun-Woo;Lee, Ho-Kyung;Han, Min-Woo;Seo, Mi-Hyun;Kim, Hyun-Jun;Song, Seung-Il
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.3
    • /
    • pp.161-166
    • /
    • 2013
  • Purpose: This study was intended to perform a cephalometric comparison between the patients with and without obstructive sleep apnea (OSA). The factors influencing the OSA in the lateral cephalogram were also investigated. Methods: Fifty patients who had visited the Sleep Disorder Clinic at the Ajou University Hospital and evaluated with the polysomnograph (PSG) and cephalogram, were included in the study. The patients had the apnea-hypopnea episode over 5 times per hour (apnea-hypopnea index $[AHI]{\geq}5$) were diagnosed as OSA after the overnight PSG. To evaluate the hard and soft tissue profiles, the cephalometric radiograms were taken at the maximal intercuspation. The correlation between the patient's age, height, weight, body mass index (BMI) and AHI was inspected in the OSA and control group. The difference between the OSA and control group was evaluated (Mann-Whitney U Test). The cephalometric influencing factors to OSA were analyzed (Pearson's correlation coefficient) statistically using SPSS statistics. Results: The OSA Group had a significantly higher BMI than the control group. The mean lower facial height (ANS-Me) was longer in the OSA group; however, statistically significant difference was not detected in the anteroposterior craniofacial measurements. The distance between mandibular plane and hyoid bone of the OSA group was significantly longer than that of the control group. The hyoid position (MP-Hyoid) had a positive correlation between AHI (P<0.001). However, the measurements of oropharyngeal airway were not different between the two groups. The hypothesis, that the antero-posteriorly narrow oropharyngeal airway may aggravate the airway resistance and give rise to a higher AHI, was rejected in the study. Conclusion: We suggest that the lateral cephalogram may be utilized as a useful method to evaluate OSA. The patients with a lower hyoid position can be expected to have higher risks of OSA. However, a comprehensive intraoral inspection, including the soft palate and tonsilar hypertrophy, is emphasized, as the lateral cepahlogram cannot visualize the oropharyngeal status completely.

Finite Element Stress Analysis of Bone Tissue According to the Implant Connection Type (2종의 임플란트 내부결합구조체에 따른 치조골상 유한요소응력 분석)

  • Byun, Ook;Jung, Da-Un;Han, In-Hae;Kim, Seong-Ryang;Lee, Chang-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.259-271
    • /
    • 2013
  • The purpose of this study was to make the stress distribution produced by simulated different load under two types of internal connection implant system (stepped and tapered type) by means of 3D finite element analysis, The finite element model was designed with the parallel placement of the one fixtures ($4.0mm{\times}11.5mm$) with reverse buttress thread on the mandibular 1st molar. Two models were loaded with 200 N magnitude in the vertical direction on the central position of the crown, the 1.5 mm and 3 mm buccal offset point from the central position of the fixture. The oblique load was applied at the angle of $30^{\circ}$ on the crown surface. Von Mises stress value was recorded and compared in the fixture-bone interface in the bucco-lingual dimension. The results were as follows; 1. The loading conditions of two internal connection implant systems (stepped and tapered type) were the main factor affecting the equivalent bone strain, followed by the type of internal connections. 2. The stepped model had more mechanical stability with the reduced max. stress compared to $11^{\circ}$ tapered models under the distributed oblique loading. 3. The more the contact of implant-abutment interface to the inner wall of implant fixture, the less stress concentration was reduced.