• Title/Summary/Keyword: Mandibular molar

Search Result 887, Processing Time 0.035 seconds

Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an ex vivo study using a bovine rib model

  • Choi, Yoon-Sil;Oh, Jae-Woon;Lee, Young;Lee, Dong-Woon
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.5
    • /
    • pp.411-421
    • /
    • 2022
  • Purpose: In this study, we aimed to evaluate the degree of heat generation when a novel drill design with an irrigation slot was used with metal sleeve-free (MF) and metal sleeve-incorporated (MI) surgical guides in an environment similar to that of the actual oral cavity. Methods: A typodont with a missing mandibular right first molar and 21 bovine rib blocks were used. Three-dimensional-printed MF and MI surgical guides, designed for the placement of internal tapered implant fixtures, were used with slot and non-slot drills. The following groups were compared: group 1, MI surgical guide with slot drill; group 2, MI surgical guide with a non-slot drill; and group 3, MF surgical guide with a slot drill. A constant-temperature water bath at 36℃ was used. The drilling was performed in 6 stages, and the initial, highest, and lowest temperatures of the cortical bone were measured at each stage using a non-contact infrared thermometer. Results: There were no temperature increases above the initial temperature in any drilling procedure. The only significant difference between the non-slot and slot groups was observed with the use of the first drill in the MI group, with a higher temperature in the non-slot group (P=0.012). When the heat generation during the first and the second drilling was compared in the non-slot group, the heat generation during the first drilling was significantly higher (P<0.001), and there was no significant difference in heat generation between the drills in the slot group. Conclusions: Within the limitations of this study, implant-site preparation with the surgical guide showed no critical increase in the temperature of the cortical bone, regardless of whether there was a slot in the drill. In particular, the slotted drill had a cooling effect during the initial drilling.

Effects of titanium and PEEK abutments on implant-supported dental prosthesis and stress distribution of surrounding bones: three-dimensional finite element analysis (티타늄 및 PEEK 지대주 소재가 임플란트 유지 수복물 및 주위 지지골 응력 분포에 미치는 영향: 3차원 유한요소해석)

  • Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.44 no.3
    • /
    • pp.67-75
    • /
    • 2022
  • Purpose: This study aimed to comparatively evaluate the stress distribution of bones surrounding the implant system to which both titanium and polyetheretherketone (PEEK) abutments are applied using a three-dimensional finite element analysis. Methods: The three-dimensional implant system was designed by the computer-aided design program (CATIA; Dassault Systemes). The discretization process for setting nodes and elements was conducted using the HyperMesh program (Altair), after finishing the design of each structure for the customized abutment implant system. The results of the stress analysis were drawn from the Abaqus program (Dassault Systèmes). This study applied 200 N of vertical load and 100 N of oblique load to the occlusal surface of a mandibular first molar. Results: Under external load application, the PEEK-modeled dental implant showed the highest von Mises stress (VMS). The lowest VMS was observed in the Ti-modeled abutment screws. In all groups, the VMS was observed in the crestal regions or necks of implants. Conclusion: The bones surrounding the implant system to which the PEEK abutment was applied, such as the cortical and trabecular bones, showed stress distribution similar to that of the titanium implant system. This finding suggests that the difference in the abutment materials had no effect on the stress distribution of the bones surrounding implants. However, the PEEK abutments require mechanical and physical properties improved for clinical application, and the clinical application is thought to be limited.

Effects of Kinesio Taping on Edema Control in Patients With Musculoskeletal Injuries: A Literature Review

  • Yong, Joon-hyoung;Lim, Jin-seok;Moon, Il-young;Yi, Chung-hwi
    • Physical Therapy Korea
    • /
    • v.29 no.3
    • /
    • pp.171-179
    • /
    • 2022
  • Background: The application of Kinesio tape (KT) has become an alternative treatment for the reduction of edema owing to its distinct characteristics that mimic skin behavior. Although many studies have found that KT application has a positive effect on edema related to breast cancer and rehabilitation following mandibular third molar surgery, there is little evidence to support the use of KT for musculoskeletal injuries. Objects: The purpose of this study was to review the literature related to KT application for reducing edema caused by musculoskeletal disorders. Methods: A literature search (July 2022) was performed on PubMed for articles published between January 2012 and June 2022. The following keywords were used: "Kinesio taping," "Kinesio tape," "swelling," and "edema," with different combinations and derivations. Only articles available in English were included in this study. Results: Among 68 identified studies, seven met our search strategy and criteria and were included in the literature review. Five of these studies investigated musculoskeletal disorders of the knee joint; two of them reported that KT application had a positive effect on edema measured using perimetry following total knee replacement and anterior cruciate ligament reconstruction. However, the KT application did not improve swelling in patients with acute lateral ankle sprains. Pediatric patients with acute proximal phalangeal joint sprain experienced a more significant improvement in the reduction of swelling than the group using a splint. Conclusion: This literature review found discrepant evidence to support using KT for edema control in musculoskeletal disorders. Further research is needed to determine the effectiveness of KT for controlling edema following musculoskeletal injuries.

The comparison of the accuracy of temporary crowns fabricated with several 3D printers and a milling machine

  • Junsik Lee;Sungwon Ju;Jihyung Kim;Sion Hwang;Jinsoo Ahn
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.2
    • /
    • pp.72-79
    • /
    • 2023
  • PURPOSE. The purpose of this in vitro study was to compare the accuracy of various 3D printers and a milling machine. MATERIALS AND METHODS. The die model was designed using CAD (Autodesk Inventor 2018 sp3). The 30 ㎛ cement space was given to the die and the ideal crown of the mandibular left first molar was designed using CAD (ExoCAD). The crowns were produced using the milling machine (Imes-icore 250i) and the 3D printers (Zenith U, Zenith D, W11) and they were divided into four groups. In all groups, the interior of each crown was scanned (Identica blue) and superimposed (Geomagic Control X) with the previously designed die. The difference between the die and the actual crown was measured at specific points. The Kruskal-Wallis test, the Mann-Whitney test, and Bonferroni's method were performed with a statistical analysis software (P < .008 in inter-group comparison P < .001 in intra-group comparison). RESULTS. In all groups, the center of the occlusal area and the anti-rotational dimple area showed significantly greater difference and the marginal area showed the smallest difference comparatively. The mean value of the difference in each area and the sum of the differences were higher in order of W11, Imes-icore 250i, Zenith D, and Zenith U. CONCLUSION. The digital light processing (DLP) method shows higher accuracy compared to the sereolithography (SLA) method using the same resin material.

Marginal fit of three different nanocomposite inlays fabricated with computer-aided design/computer-aided manufacturing (CAD/CAM) technology: a comparative study

  • Hyunsuk Choi;Jae-Young Jo;Min-Ho Hong
    • Journal of Yeungnam Medical Science
    • /
    • v.41 no.2
    • /
    • pp.80-85
    • /
    • 2024
  • Background: This study aimed to compare and evaluate the marginal fit of nanocomposite computer-aided design/computer-aided manufacturing (CAD/CAM) inlays. Three types of nanocomposite CAD/CAM blocks (HASEM, VITA Enamic, and Lava Ultimate) were used as materials. Methods: Class II disto-occlusal inlay restorations were prepared on a typodont mandibular right first molar using diamond rotary instruments. The inlays were fabricated using CAD/CAM technology and evaluated using the silicone replica technique to measure marginal gaps at five locations on each inlay. The data were analyzed by two-way analysis of variance and Tukey post hoc tests (α=0.05). Results: There were no significant differences in the marginal gaps based on the type of nanocomposite CAD/CAM inlay used (p=0.209). However, there was a significant difference in the marginal gaps between the measurement regions. The gingival region consistently exhibited a larger marginal gap than the axial and occlusal regions (p<0.001). Conclusion: Within the limitations of this in vitro study, the measurement location significantly influenced the marginal fit of class II disto-occlusal inlay restorations. However, there were no significant differences in the marginal gaps among the different types of CAD/CAM blocks. Furthermore, the overall mean marginal fits of the class II disto-occlusal inlay restorations made with the three types of nanocomposite CAD/CAM blocks were within the clinically acceptable range.

Dental and skeletal characteristics and growth in Class III malocclusion between skeletal ages of 10 and 14 (10세에서 14세 사이 III급 부정교합자의 치아안면두개의 형태학적 특성에 대하여)

  • Min, Seungki;Lee, Young-Jun;Park, Young-Guk;Rothstein, Ted
    • The korean journal of orthodontics
    • /
    • v.33 no.6 s.101
    • /
    • pp.419-435
    • /
    • 2003
  • The purpose of this study was to evaluate growth changes and skeletal characteristics of Korean children with Class III malocclusions from 10 to 14 years of skeletal age. Radiographs of 60 children with Class III malocclusion and 60 normal controls were assessed. Both groups were subdivided into 6 samples according to sex and skeletal age. Skeletal age was assessed using handwrist X-rays using the Greulich and Pyle norms. The Krogman-Walker plane (occipitale-maxillon) through Sella was used as a reference plane in this study with x-axis perpendicular to the x-axis. Sir Student t-tests were conducted to compare the control group with the Class III group according to each gender a:nd age. The characteristics of Class III malocclusion group compared to the control group included shorter anterior and posterior cranial base, shorter and retrusive maxilla, forger mandible, increased molar-incisor distance, retroclined lower incisors, labially proclined upper incisors, and anteriorly located mandibular molar, smaller upper and middle facial depth, and larger lower facial depth. Landmarks representing facial depth, size of maxilla and mandible, and their AP relationship including anterior facial height indicate that growth characteristic was determined early in life. But growth Pattern of cranial base and some of the dental landmarks showed progressive divergence between Control and Class III groups with age. The position of the posterior border of the mandible was found to be significantly forward in both females and males by the age of 14 and at the anterior border in males and females at all ages. Hyperdivergent mandibular plane, changes in anterior segment of mandible, small anterior cranial base, and decrease in cranial base flexure was also noted.

A Study on the changes of periodontal tissue after orthodontic tooth movement in young adult dogs (유성견에서 교정적 치아이동에 따른 치주조직 변화에 관한 연구)

  • Kang, Nam-Yong;Yoon, Young-John;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.559-568
    • /
    • 1997
  • For orthodontic tooth movement, optimal orthodontic force should be maintained without periodontal breakdown and alveolar bone should be remodeled physiologically Therefore, To obtain proper occlusion through tooth movement within alveolar bone, we should know the biomechanics of teeth and supporting 4issues. The present study was performed to observe histologic changes of periodontal tissue immediately after application of orthodontic force and during the retention period in growing young adult dogs. In this study, experimental group contained between mandibular left canine and 1st molar and control group contained contralateral teeth of same animal. The .018'x.022' stainless steel closed coil spring(Dentaurum Co.) was ligated on the experimental teeth at initial 200gm-force from mandibular canine to 1st molar The animals(4 to 6 months aged young adult dogs) were sacrificed on 0, 14, 28 days after the finish of appliance activation, and then tissue samples were divided into hematoxylin-eosin(HE) staining section, ground section, alkaline phosphatase(ALP) staining section, and tartrate-resistant acid phosphatase(TRAP) staining section. Thereafter, the preparations were examined under light microscopy The following results were obtained: 1. Immediately after the finish of appliance activation, the periodontal space was increased in tension side, but decreased in pressure side compared to that of control. The hyalinized zone was also observed in the periodontium. 2. After the 14-day retention, peridontal space was decreased in tension side and slightly increased in pressure side compared to that of immediately after the finish of appliance activation. The hyalinized zone was repaired and a few osteoblasts showing slightly new bone formation were seen. Osteoblasts were scarcely observed along the alveolar bone. 3. Aftter the 28-day retention, the periodontal fibers are normally repaired. A lot of TRAP(+) osteoclasts md increased alveolar bone resorption were observed in pressure side, and AP(+) osteoblast and increased new bone formation were observed in tension side.

  • PDF

The Influence of Attachment Type on the Distribution of Occlusal Force in Implant Supported Overdentures (하악 임플란트 오버덴쳐에서 어태치먼트 종류에 따른 응력분포)

  • Sung, Chai-Ryun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.375-390
    • /
    • 2009
  • Statement of problem: Implant supported overdenture is accepted widely as a way to restore edentulous ridge providing better retention and support of dentures. Various types of attachment for overdenture have been developed. Purpose: The purpose of this study was to investigate the influence of attachment type in implant overdentures on the biomechanical stress distribution in the surrounding bone, prosthesis and interface between implant and bone. Material and methods: Finite element analysis method was used. Average CT image of mandibular body(Digital $Korea^{(R)}$, KISTI, Korea) was used to produce a mandibular model. Overdentures were placed instead of mandibular teeth and 2mm of mucosa was inserted between the overdenture and mandible. Two implants($USII^{(R)}$, Osstem, Korea) were placed at both cuspid area and 4 types of overdenture were fabricated ; ball and socket, Locator, magnet and bar type. Load was applied on the from second premolar to second molar tooth area. 6 times of finite element analyses were performed according to the direction of the force $90^{\circ}$, $45^{\circ}$, $0^{\circ}$ and unilateral or bilateral force applied. The stress at interface between implants and bone, and prosthesis and the bone around implants ware compared using von Mises stress. The results were explained with color coded graphs based on the equivalent stress to distinguish the force distribution pattern and the site of maximum stress concentration. Results: Unilateral loading showed that connection area between implant fixture and bar generated maximum stress in bar type overdentures. Bar type produced 100 Mpa which means the most among 4 types of attachments. Bilateral loading, however, showed that bar type was more stable than other implants(magnet, ball and socket). 26 Mpa of bar type was about a half of other types on overdenture under $90^{\circ}$ bilateral loading. Conclusions: In any directions of stress, bar type was proved to be the most vulnerable type in both implants and overdentures. Interface stress did not show any significant difference in stress distribution pattern.

Relationship between the Malocclusion and Caries Prevalence of Adolescents in Iksan (익산시 청소년의 부정교합과 치아우식 유병률 사이의 연관성)

  • Shin, Gayoung;Ra, Jiyoung;An, Soyoun;Song, Jihyun;Lee, Kwanghee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.3
    • /
    • pp.207-217
    • /
    • 2014
  • The purpose of the present study was to evaluate the relationship between the malocclusion and dental caries in adolescents with permanent dentition. The subjects of the study were 385 adolescents aged 12 to 15 years. Dental Aesthetic Index (DAI) and DMFT index were recorded as clinical indicators of malocclusion and dental caries. The mean Dental Aesthetic Index (DAI) score of the subjects was 12.42 and the mean DMFT index of the subjects was 2.89. Four students (1.04%) were included in the group of orthodontic treatment mandatory, which signifies the handicapping malocclusion. Moreover, the result of gender-specific analysis of the DAI components observed that the prevalence of midline diastema and mandibular overjet were significantly higher among boys (p < 0.05). In 7 components (missing teeth, incisal segment crowding, maxillary anterior irregularity, mandibular anterior irregularity, mandibular overjet, anterior openbite, antero-posterior molar relationship) among the 10 DAI components, abnormal groups showed significantly higher DMFT index than normal groups (p < 0.05). The subjects in the group of definite to handicapping malocclusion (DAI ${\geq}$ 26) showed significantly higher DMFT index than the subjects in the group of minor or no malocclusion (p < 0.01). In addition, the DAI score had significant positive linear correlation with the DMFT index (r = 0.584, p < 0.01). Consequently, the current findings suggested a positive relationship between the malocclusion and caries prevalence. And several specific types of malocclusion were supposed to be significantly correlated with dental caries.

Photoelastic stress analysis of the mandibular unilateral free-end removable partial dentures according to the design (하악 편측 유리단 가철성 국소의치의 설계에 따른 광탄성 응력 분석)

  • Park, Cheol-Woo;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.206-214
    • /
    • 2009
  • Statement of problem: There are common clinical cases in which the mandibular first and second molars are missing unilaterally. Purpose: This study was designed to compare and evaluate the magnitude and distribution of stress produced by four kinds of mandibular unilateral free-end removable partial dentures that could be applied clinically in Kennedy class II cases. Material and methods: Four unilateral free-end removable partial dentures using clasp, Konus crown, resilient attachment, and flexible resin were fabricated on the photoelastic models of the Kennedy class II cases. The vertical load of 6㎏ was applied on the central fossa of the first molar of every removable partial denture in the stress freezing furnace and the photoelastic models were frozen according to the stress freezing cycle. After these models were sliced mesio-distally to a thickness of 6mm, the photoelastic isochromatic white and black lines of the sliced specimens were examined with the transparent photoelastic experiment device and photographs were taken with a digital camera. The fringe order numbers at eight measuring points in the photograph were measured with the naked eye. Results: The maximum fringe order number of each sliced specimen and the fringe order number at the residual ridge just below the loading point were in the decreasing order of the unilateral removable partial dentures using flexible resin followed by clasp, resilient attachment, and Konus crown. The fringe order number at the root apex of the second premolar was in the decreasing order of the unilateral removable partial dentures using clasp followed by flexible resin, Konus crown, and resilient attachment. Conclusion: The removable partial denture using Konus crown showed the most equalized stress distribution to the supporting alveolar bone of abutment teeth and residual ridge under the vertical loads. The removable partial denture using flexible resin can be applied to the case that has a better state of residual ridge than abutment teeth.