• 제목/요약/키워드: Mandibular implant Overdenture

검색결과 73건 처리시간 0.018초

완전 무치악 환자에서 Locator® system을 이용한 임플란트 피개의치 수복 증례 (Implant Supported Overdenture using Locator® System on Edentulous Patient)

  • 이상엽;신수연
    • 구강회복응용과학지
    • /
    • 제24권4호
    • /
    • pp.351-359
    • /
    • 2008
  • 임플란트의 도입으로 악골이 흡수된 무치악 환자의 보철 치료에 획기적인 변화가 가능해졌다. 특히 하악 무치악 환자의 경우 2개의 임플란트에 의해 유지를 얻는 피개의치가 일반적인 총의치의 대안으로 자리잡았으며 첫 번째로 고려되어야 할 치료 방법으로 받아들여지고 있다. 본 증례는 상하악 완전 무치악 환자로서 상악에는 일반적인 총의치, 하악에는 2개의 임플란트를 식립하고 $Locator^{(R)}$ Attachment를 사용하여 수복한 임상과정 및 결과에 관하여 보고하고자 한다.

Immediate loading on mandibular edentulous patient with SFI Bar$^{(R)}$ overdenture

  • Kim, Ha-Young;Kim, Jin-Young-Ryan;Qadeer, Sarah;Jeong, Chang-Mo;Shin, Sang-Wan;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권1호
    • /
    • pp.47-50
    • /
    • 2011
  • Despite the greater retention and low maintenance of bar attachment system, the longer clinical time and increased number of visits were the assignments to overcome in bar attachment system. This case report describes SFI-Bar$^{(R)}$ (Cendres et Me$\'{e}$taux, Biel/Bienne, Switzerland) to be solve those problems. A 65-year-old female, who had severely absorbed mandible, hoped to wear a stable mandibular denture without pain. As soon as two implants were placed on mandible, a tube bar was connected to two adaptors connected to each implant. The length of the tube bar was adjusted considering inter implant distance, and reconnected to the adaptors. Finally a female part was seated beneath the denture. This case report showed that a satisfactory clinical result was achieved by delivering bar overdenture immediately after implant placement without laboratory procedure.

스트레인 게이지를 이용한 임플랜트 지지 오버덴춰의 응력분석 (A STRESS ANALYSIS OF THE IMPLANT - SUPPORTED OVERDENTURE USING STRAIN GAUGE)

  • 조혜원;권주홍;이화영
    • 대한치과보철학회지
    • /
    • 제37권1호
    • /
    • pp.93-103
    • /
    • 1999
  • Stress distribution on mandibular implants supporting overdentures were registered in vitro experimental model by means of 4 rosette gauges which were placed around the implant. The overdenture attachments used in this study were the Resilient Dolder bar, Rigid Bolder bar, Round bar, Hader bar & Dal-Ro attachment. An occlusal jig was placed on the overdenture and the loading sites were 3 points which mimicked working, balancing, and median relations. With 5 and 10kg loading, strains were measured by strain indicator(P-3500, Measurement group, Raleigh, USA), and using these data, maximum and minimum principal stresses and Von Mises stress were calculated and evaluated. The results were as follows : There was a tendency of high stress concentration in the lingual side of the implant, and in the buccal side low stress was developed regardless of the attachment systems. The resilient Bolder bar concentrated highest stress among the attachment systems, and the Round bar and the Dal-Ro attachment provided comparatively low stresses around the implant. The rigid Bolder bar concentrated high stress in the mesial side, and the Dal-Ro attachment developed tensile stress patterns in the lingual and distal sides of the implant at the balancing relation.

  • PDF

CAD/CAM 시스템으로 제작한 Milled Bar를 이용한 하악 임플란트 피개의치 수복증례 (Rehabilitation using mandibular implant overdenture with CAD/CAM milled bar: A case report)

  • 반민희;양홍서;박상원;임현필;윤귀덕;신진호;박찬
    • 대한치과보철학회지
    • /
    • 제55권3호
    • /
    • pp.292-299
    • /
    • 2017
  • 무치악 환자에서 치아 상실 후 오랜 기간에 걸친 치조골 흡수는 의치의 사용을 어렵게 한다. 하악 무치악 환자에게 두 개 혹은 네 개의 임플란트를 식립하여 임플란트 피개의치를 이용하는 방식은 쉽게 접근할 수 있고, 의치의 유지, 지지와 안정을 크게 향상시킬 수 있는 방법이다. 임플란트 피개의치에 사용되는 어태치먼트 중에서 milled bar는 기성 bar보다 상부 구조물의 견고한 안정성과 충분한 유지력을 얻기 위해 사용할 수 있으며, 최근 CAD/CAM system의 발달과 함께 기공과정이 간소화되어 이용이 용이하게 되었다. 본 증례는 오랜 기간 상, 하악 총의치를 사용했던 환자에게 상악은 전통적인 방식으로 제작한 총의치와 하악에 네 개의 임플란트를 식립하여 CAD/CAM milled bar를 이용해 하악 임플란트 피개의치로 수복하여 만족스러운 결과를 얻었기에 이를 보고하는 바이다.

The influence of the number and the type of magnetic attachment on the retention of mandibular mini implant overdenture

  • Lee, Eunjee;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권1호
    • /
    • pp.14-21
    • /
    • 2017
  • PURPOSE. The aim of this study was to compare the retention of mini implant overdenture by the number, the type of magnetic attachment, and the directions of applied dislodging force. MATERIALS AND METHODS. The experimental groups were designed by the number and type of magnetic attachment. Twenty samples were tested with Magden implants. Each attachment was composed of the magnet assembly in overdenture sample and the abutment keeper in a mandibular model. Dislodging forces were applied to the overdenture samples (50.0 mm/min) in 3 directions. The loading was repeated 10 times in each direction. The values of dislodging force were analyzed statistically using SPSS at 95% level of confidence. RESULTS. The retentive force of group 2 was greater than that of group 1 in both types of attachment in every direction (P < .05). Oblique retentive force of flat type magnetic attachment was higher than that of cushion type attachment in both groups (P < .05). In group 1, oblique retentive force showed the highest and anterior-posterior retentive force showed the lowest value in both attachment types (P < .05). In group 2, both types of attachment showed the lowest retentive force with anterior-posterior direction of dislodging force (P <.05). CONCLUSION. Proper retentive properties for implant overdenture were obtained, regardless of the number and type of magnetic attachment. In both types of magnetic attachment, the greater retentive force was attained with more implants. Oblique retentive force of flat type magnetic attachment was greater than that of cushion type. Among all subgroups, anterior-posterior retentive force was the lowest among three different directions of dislodging force.

한 환자에서 실패한 임플란트 부착장치들의 원인과 이중관 임플란트 피개 의치의 적용 (Causes of failed implant attachments and application of double crown implant overdenture in one patient)

  • 권재욱;조진현
    • 대한치과보철학회지
    • /
    • 제56권4호
    • /
    • pp.368-374
    • /
    • 2018
  • 본 증례의 환자는 약 10여년 전 2개의 임플란트를 이용하여 Gold Hader bar 하악 임플란트 피개 의치로 수복하였고, 3년 6개월의 사용으로 인한 bar의 심한 마모로 유지력을 상실하였다. 이를 Locator 부착장치를 이용하여 하악 피개 의치를 수리하였으나, Locator 사용 6년 6개월 후 male 부위가 완전히 닳은 상태로 내원하게 되었다. 다음으로는 하이브리드 이중관(Hybrid telescopic double crown with friction pin)을 사용하여 임플란트 피개 의치를 새로 제작하였고, 이를 2년동안 관찰한 결과 우수한 예후를 보여주고 있다. 여기에서 한 환자에서 2가지(Gold Hader bar, Locator)방법으로 수복한 임플란트 피개 의치에서 각 부착장치의 실패원인에 대해서 알아보고, 이중관 피개 의치의 장단점과 성공을 위한 조건에 대해서 보고하고자 한다.

상악 완전 무치악 환자에서 CM LOC® Pekkton® attachment를 이용한 임플란트 유지 피개의치 수복 증례 (Implant-retained overdenture with CM LOC® Pekkton® in maxillary edentulous patient)

  • 홍문기;신수연
    • 구강회복응용과학지
    • /
    • 제33권4호
    • /
    • pp.321-328
    • /
    • 2017
  • 무치악은 총의치나 임플란트 보철물로 수복이 가능하며 임플란트를 이용한 피개의치는 총의치보다 유지와 안정이 우수하고, 임플란트 고정성 보철물에 비해 저렴하고 심미적이다. CM $LOC^{(R)}$ $Pekkton^{(R)}$ 어태치먼트는 여자부가 poly-ether-ketone-ketone으로 마모저항성이 뛰어나다. 한편, SR Ivocap system은 가압주사성형법으로 의치의 수직고경 변화가 적고 강도가 우수하다. 본 증례에서 상악은 4개의 임플란트 식립 후 CM $LOC^{(R)}$ $Pekkton^{(R)}$ 어태치먼트와 SR Ivocap system을 이용한 임플란트 유지 피개의치를, 하악은 가철성 국소의치를 제작하였고 심미적 및 기능적으로 만족스러운 결과를 얻었기에 이를 보고하는 바이다.

심한 편측 하악 치조골 흡수를 보이는 환자에서의 임플란트 피개의치 수복 증례 (Implant overdenture of mandible with severe unilateral atrophy: Report of two cases)

  • 김소연;권은영;정경화;전혜미;백영재;윤미정;허중보
    • 대한치과보철학회지
    • /
    • 제57권3호
    • /
    • pp.271-279
    • /
    • 2019
  • 심한 하악 치조골 흡수룰 보이는 완전 무치악 환자에서 의치는 환자의 저작 효율이 극히 저하되며 특히 치조골의 형태가 불규칙한 경우 의치의 안정성은 더 떨어질 수 있다. 이때 임플란트를 통한 지지를 얻는 피개의치를 통해 편안감 회복과 향후 지속적인 치조골 흡수를 줄이는데 도움을 줄 수 있다. 임플란트 피개의치를 위한 하방의 attachment는 크게 bar attachment와 solitary attachment로 나뉘며 임플란트 고정체의 위치가 하악 전방 치조골에 있으면서 의치 전체가 견고한 지지를 얻기 위해서는 bar attachment가 유리하고 구치부에도 고정체가 위치하며 쉬운 착탈과 유지관리의 편의를 얻고자 하면 solitary attachment를 고려할 수 있다. 본 증례는 환자의 상황에 따른 임플란트 식립 위치 결정, attachment를 선택을 통하여 임플란트 피개의치를 다양하게 적용하여 만족할만한 결과를 얻어 이를 보고하는 바이다.

Influence of marginal bone resorption on two mini implant-retained mandibular overdenture: An in vitro study

  • Guo, Ying;Kono, Kentaro;Suzuki, Yasunori;Ohkubo, Chikahiro;Zeng, Jian-Yu;Zhang, Jing
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권1호
    • /
    • pp.55-64
    • /
    • 2021
  • PURPOSE. To investigate the biomechanical effect of marginal bone resorption (MBR) on the mandibular mini implant (MI)-retained overdenture (MI-OD) on the edentulous model. MATERIALS AND METHODS. The experimental mandibular edentulous model was modified from a commercial model with 2 mm thick artificial soft tissue under denture base. Two MIs (Φ2.6 mm × 10 mm) were bilaterally placed between the lateral incisor and the canine area and attached with magnetic attachments. Three groups were set up as follows: 1) alveolar bone around the MI without MBR (normal group), 2) with MBR to 1/2 the length of the implant (resorption group), and 3) complete denture (CD) without MI (CD group). Strain around the MI, pressure near the first molar area, and displacement of denture were simultaneously measured, loading up to 50 N under bilateral/unilateral loading. Statistical analysis was performed using independent-samples t test and one-way ANOVA (α=.05). RESULTS. The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure in CD was higher than in MI-ODs (P<.05), while there was no statistical difference between the normal and resorption group (P>.05). Similarly, the CD demonstrated a greater displacement of the denture base than did the MI-ODs during bilateral and unilateral loadings (P<.05). CONCLUSION. The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure on posterior alveolar ridge and denture displacement of MI-ODs significantly decreased compared to CDs, even when MBR occurs. Bilateral balanced occlusion was recommended for MI-ODs, especially when MBR occurred.