• 제목/요약/키워드: Mandibular foramen

검색결과 104건 처리시간 0.025초

수종의 Engine driven NiTi file과 stainless steel K-file을 이용한 근관형성 후 근관의 조직형태학적 변화에 관한 연구 (A STUDY OF HISTOMORPHOLOGICAL CHANGE OF CURVED ROOT CANAL PREPARATION USING GT ROTARY FILE, PROFILE AND STAINLESS STEEL K-FILE)

  • 고현정;백승호
    • Restorative Dentistry and Endodontics
    • /
    • 제27권6호
    • /
    • pp.612-621
    • /
    • 2002
  • The purpose of this study was to compare the histomorphological change of curved root canal preparation using GT rotary File, Profile .04 taper and stainless steel K-file. 45 mesial canals(over 20 degree) of extracted human mandibular first molars were mounted in resin using a modified Bramante muffle system and divided into three groups. The roots were cross-sectioned at 2.5mm 5mm and 8mm levels from apical foramen. Tracings of the canals were made from preinstrumentation pictures of the cross section. The canals were prepared using a step-back technique with stainless steel K file(group 1), Profile .04 taper rotary file(group 2) and GT rotary file(group 3). Tracings of the prepared canals were made from postinstrumentation picture. Canal centring ratio. amount of transportation, area of dentin removed and shape of canal were measured and statistically were evaluated with Student-Newman-Keuls test using Sigma Stat(Jandel Scientific Software, USA). The results were as followings : 1 Amount of transportation of group 2 was the lowest at apical part, but there was no statistical difference. The direction of transportation was the outside of curvature at apical part. 2. Centering ratio at the apical part of group 1 was the highest, and there was statistical differences between apical and middle part, apical and coronal part(p<0.05). Centering ratio at the middle part of group 3 was the lowest, and there was statistical difference between apical and middle part(p<0.05). Centering ratio of group 2 was the lowest at apical part, but there was no statistical difference. 3. Amount of dentin removed of group 1 was the highest at coronal, middle and apical part among three groups, and there was statistical difference(p<0.05). 4. The majority of the cross-sectioned canal shape after instrumentation were irregular at coronal, middle and apical part. But there are more number of round shaped canals at group 3 than other group.

Radiographic evaluation of the symphysis menti as a donor site for an autologous bone graft in pre-implant surgery

  • Bari, Roberto Di;Coronelli, Roberto;Cicconetti, Andrea
    • Imaging Science in Dentistry
    • /
    • 제43권3호
    • /
    • pp.135-143
    • /
    • 2013
  • Purpose: This study was performed to obtain a quantitative evaluation of the cortical and cancellous bone graft harvestable from the mental and canine regions, and to evaluate the cortical vestibular thickness. Materials and Methods: This study collected cone-beam computed tomographic (CBCT) images of 100 Italian patients. The limits of the mental region were established: 5 mm in front of the medial margin of each mental foramen, 5 mm under the apex of each tooth present, and above the inferior mandibular cortex. Cortical and cancellous bone volumes were evaluated using SimPlant software (SimPlant 3-D Pro, Materialize, Leuven, Belgium) tools. In addition, the cortical vestibular thickness (minimal and maximal values) was evaluated in 3 cross-sections corresponding to the right canine tooth (3R), the median section (M), and the left canine tooth (3L). Results: The cortical volume was $0.71{\pm}0.23mL$ (0.27-1.96 mL) and the cancellous volume was $2.16{\pm}0.76mL$ (0.86-6.28 mL). The minimal cortical vestibular thickness was $1.54{\pm}0.41mm$ (0.61-3.25 mm), and the maximal cortical vestibular thickness was $3.14{\pm}0.75mm$ (1.01-5.83 mm). Conclusion: The use of the imaging software allowed a patient-specific assessment of mental and canine region bone availability. The proposed evaluation method might help the surgeon in the selection of the donor site by the comparison between bone availability in the donor site and the reconstructive exigency of the recipient site.

ProTaper와 ProFile을 사용한 Hybrid instrumentation method의 근관 형성 전, 후 근관 단면적과 근관벽에서 치근외면까지 최단거리의 변화에 미치는 영향에 대한 실험적 연구 (The experimental study of the effect of the hybrid instrumentation method with ProTaper and ProFile on the change of root canal area and distance from the canal to the root surface after canal shaping.)

  • 김석민;박동성
    • 대한치과의사협회지
    • /
    • 제45권6호통권457호
    • /
    • pp.362-369
    • /
    • 2007
  • The aim of this study was to investigate the effect of the hybrid instrumentation method with ProTaper and ProFile on the change of root canal area and distance from the canal to the root surface after canal shaping. The mesial canals of twenty extracted mandibular first molars having $10-20^{\circ}\Delta$ curvature were scanned using X-ray microcomputed tomography (XMCT)-scanner before root canals were instrumented. They were divided into four groups (n=10 canals ter group). In Group 1, root canals were instrumented by the step-back technique with stainless steel K-Flexofile after coronal flaring. The remainders were instrumented by the crown-down technique with, ProTaper system (Group 2), ProFile (Group 3) or ProTaper (Group 4). All canals were prepared up to size 25 at the end-point of preparation and scanned again. Pre- and post-operative cross-sectional images of 1, 3, 5, and 7 mm from the apical foramen were compared. For each level, change of cross-sectional canal are and distance to the nearest external root surface was calculated using Adobe Photoshop 6.0 and image software program. In the change of cross-sectional area, Group 4 was less than Group 2 at 3 mm and 5 mm level (p<0.05). In the difference of the distance from the canal to the root surface after canal shaping, Group 4 was least among the other groups at 7 mm level (p<0.05). According to the results, the methods using ProFile or K file only and the hybrid instrumentation technique using ProTaper and ProFile are more appropriate methods of canal preparation than ProTaper system for narrow of curved canals.

  • PDF

The Utility of a Three-Dimensional Approach with T-Shaped Osteotomy in Osseous Genioplasty

  • Jegal, Jung Jae;Kang, Seok Joo;Kim, Jin Woo;Sun, Hook
    • Archives of Plastic Surgery
    • /
    • 제40권4호
    • /
    • pp.433-439
    • /
    • 2013
  • Background Facial beauty depends on the form, proportion, and position of various units of the face. In terms of the frontal view and facial profile, the chin is the most prominent aesthetic element of the lower third of the face. Many methods have been implemented to obtain good proportions of the lower face. In this study, we applied the T-shaped genioplasty method to correcting chin deformities. Methods All of the procedures in 9 cases were performed under general anesthesia. For genioplasty, a horizontal cutting line and 1 or 2 vertical cutting lines were drawn 5 mm below the mental foramen. Osteotomed bone segments of the chin were used for horizontal widening using bone grafts or for horizontal shortening. Likewise, they were used as bone grafts for vertical lengthening or vertical shortening. The bone segments were approximated in the midline and held in place using miniplates. Results The postoperative appearance of the 9 cases showed that the lower third of the face had been naturally changed. At the same time, vertical lengthening or shortening, and horizontal widening or shortening could be implemented during the operation. Satisfactory results were obtained based on reviews of the patients' preoperative and postoperative photographs. The patients were also satisfied with the outcomes. Conclusions Using T-shaped genioplasty, we efficiently adjusted the shape and position of the chin to obtain good proportions of the lower face and change its contour to obtain an aesthetically appealing oval face in accordance with East Asians' aesthetic preferences.

치근단 손상부의 치유에 영향을 미치는 제재에 관한 병리조직학적 연구 (HISTOPATHOLOGIC STUDY ON THE HEALING PROCESS OF APICAL WOUND IN APPLYING SEVERAL MATERIALS)

  • 조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제14권2호
    • /
    • pp.49-64
    • /
    • 1989
  • The purpose of this study was to evaluate the effect of several materials on the healing process of apical wound. Sixteen mandibular premolars obtained from 4 healthy dogs were used for this study. Under general anesthesia, the pulpal chamber of each tooth was opened and the pulps were extirpated. The root canals were then instrumented with H-file and irrigated with physiologic saline solution ; the apices were purposely perforated and enlarged with the engine K-reamer. In the experimental groups, apical wounds were filled with one of calcium hydroxide, hydroxylapatite, and tricalcium phosphate materials, mixture of each materials and physiologic saline solution, with a lentulo spiral. In the control group, apical wounds were not filled with any material. All the root canals were filled by the lateral condensation technique with gutta-percha cone and ZOE sealer. The access opening of all the teeth were closed with amalgam. On the 10, 20, 40 and 60th day after experiment, experimental animals were sacrificed. Segments of jaws, each containing one tooth, were fixed in 10% formalin solution and decalcified in Plank-Rychlo solution. The specimens were embedded in paraffin and serially sectioned to an average thickness of $6{\mu}m$. The sections were stained by hematoxylin-eosin and Masson's trichrome stain method and examined under light microscope. The results were as follows : 1. In the experimental groups, the new bone formations were observed in apical wounds. 2. Fourty days later, apical wounds were healed by granulation tissue in the experimental groups, but were not healed by granulation tissue in the control group, and the healing process of experimental groups were more rapid than that of control group. 3. Sixty days later, chronic inflammation disappeared in the experimental groups, and the materials used showed biologic affinity to the periapical tissue. 4. In all the groups, the resorption of cementum appeared on the 10th and 20th day after experiment, and the deposition of cementum appeared on the 40th and 60th day after experiment, especially showing narrowness of apical foramen due to newly formed cementum in calcium hydroxide group. 5. Calcum hydroxide and tricalcium phosphate particles were gradually resolved, but hydroxylapatite particles were not resolved through the experimental period.

  • PDF

수종 근관확대 기구를 이용한 근관 형성후의 근관형태 변화에 관한 연구 (A STUDY OF ROOT CANAL SHAPE FOLLOWING CANAL PREPARATION OF VARIOUS CANAL ENLARGING INSTRUMENTS)

  • 최호영;민효기
    • Restorative Dentistry and Endodontics
    • /
    • 제16권1호
    • /
    • pp.74-86
    • /
    • 1991
  • The purpose of this study was to evaluate the resulting root canal angulation and shape change after using various enlarging instruments. The mesial canals (120) of extracted human mandibular 1st and 2nd molars were randomly divided into 6 groups; Control, K-type me, Heliapical me, Canal Master me, sonic and ultrasonic instrumentation group. Vertical angulation of each canal was determined by a straight line through the long axis of canal and another straight line through the apical foramen to intersect at the point where the canal began to leave the long axis of the tooth. By recording and comparing the measured angles of the each set of pre-and postinstrumentation. Then, the roots were sectioned horizontally in the apical, middle, coronal thirds and the canal shapes examined, as was the mesiodistal canal diameter as it relates to the external root surface. The results were as follows: 1. Instrumentation using K-type me group resulted in the highest mean change in angulation ($9.900^{\circ}$) (p < 0.005), while Sonic Air MM 3000 group resulted in the least degree of straightening canals ($8.250^{\circ}$) (p < 0.005). 2. Canal Master file group resulted in the best canal shape at the three levels (P < 0.005). 3. Measured minimal mesial root width produced Heliapical me group at the apical 1/3 level, Sonic Air MM 3000 group at the middle 1/3 level, Heliapical me group at the coronal 1/3 level (P < 0.005). 4. Measured minimal distal root width produced Sonic Air MM 3000 group at the apical 1/3 level (P < 0.05), Heliapical me group at the middle 1/3 level (P < 0.005), Canal Master me group at the coronal 1/3 level (P < 0.005). 5. HeIiapical me group produced more increased canal diameter than any other groups (P < 0.005).

  • PDF

기계적 협착부를 갖는 근관에서 Root-ZX의 정확도에 관한 연구 (A STUDY ON THE ACCURACY OF THE ROOT-ZX IN THE CANAL WITH MECHANICALLY FORMED CONSTRICTION)

  • 김병현;이영규;김용식
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.628-632
    • /
    • 1999
  • Currently electronic apex locators have been widely used to determine working length in endodontic treatment. According to Manufacture's recommendation, it is beneficial to find the working length before instrumenting the canal. However, in crown-down pressureless technique, working length of tooth is established following coronal instrumentation 3mm short of radiographic apex. In narrow canals, mechanically formed constriction might be established by coronal instrumentation in some distance from anatomical constriction. The purpose of this study was to evaluate the accuracy of Root-ZX in the canal with mechanical constriction following considerable coronal enlargement with ProFile .06 series. The 40 root canals in 30 extracted mandibular molars were accessed, and their actual length (AL) established by passing a size 10 file just through the minor apical foramen. The teeth were then embedded in an acrylic container with normal saline. The initial canal length(IL) was measured with Root-ZX by negotiating a size 10 file to the apical constriction. The canal was sequentially enlarged to size 40 with ProFile .06 file 3mm short of actual length. The enlarged final canal lengths (FL) were obtained with a size 15 file. The average values of IL, FL were calculated and compared using Repeated measures Analysis of Variance followed Turkey's Studentized Range test. The results were obtained as follows: 1. The initial canal length was 0.12mm shorter than actual canal length(P>0.05). 2. The differences between initial canal length and final canal length were not significant(P>0.05). 3. As a result of this study, regardless of mechanically formed constriction. Root-ZX differentiated between mechanical and anatomic constriction.

  • PDF

The occurrence of dental implant malpositioning and related factors: A cross-sectional cone-beam computed tomography survey

  • Safi, Yaser;Amid, Reza;Zadbin, Fariba;Ahsaie, Mitra Ghazizadeh;Mortazavi, Hamed
    • Imaging Science in Dentistry
    • /
    • 제51권3호
    • /
    • pp.251-260
    • /
    • 2021
  • Purpose: Dental implants are widely used for the rehabilitation of edentulous sites. This study investigated the occurrence of dental implant malpositioning as shown on post-implantation cone-beam computed tomography (CBCT) and to identify related factors. Materials and Methods: Samples with at least 1 malpositioned dental implant were collected from a central radiology clinic in Tehran, Iran from January 2017 to January 2019. Variables such as demographic characteristics, length and diameter of implants, type of implant, sites of implant insertion, different types of implant malpositioning problems (cortical plate perforation, interference with anatomical structures), angulation of the implant, and the severity of malpositioning were assessed. In addition, the incidence of implant fracture and over-drilling was evaluated. Data were statistically analyzed using the chi-square test, 1-sample t-test, and Spearman correlation coefficients. Results: In total, 252 patients referred for implant postoperative CBCT evaluations were assessed. The cases of implant malpositioning included perforation of the buccal cortical plate (19.4%), perforation of the lingual cortical plate (14.3%), implant proximity to an adjacent implant (19.0%), implant proximity to an adjacent tooth (3.2%), interference with anatomical structures(maxillary sinus: 18.3%, mandibular canal: 11.1%, nasal cavity: 6.3%, mental foramen: 5.6%, and incisive canal: 0.4%). Implant fracture and over-drilling were found in 1.6% and 0.8% of cases, respectively. Severity was categorized as mild (9.5%), moderate (35.7%), severe (37.7%), and extreme (17.1%), and 52.4% of implants had inappropriate angulation. Conclusion: CBCT imaging is recommended for detecting dental implant malpositioning. The most common and severe type of malpositioning was buccal cortex perforation.

Comparing the precision of panoramic radiography and cone-beam computed tomography in avoiding anatomical structures critical to dental implant surgery: A retrospective study

  • Ozalp, Oznur;Tezerisener, Huseyin Alican;Kocabalkan, Burak;Buyukkaplan, Ulviye Sebnem;Ozarslan, Mehmet Mustafa;Kaya, Goksel Simsek;Altay, Mehmet Ali;Sindel, Alper
    • Imaging Science in Dentistry
    • /
    • 제48권4호
    • /
    • pp.269-275
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the correlations between measurements made using panoramic radiography and cone-beam computed tomography (CBCT) based on certain anatomical landmarks of the jaws, with the goal of preventing complications due to inaccurate measurements in the pre-surgical planning phase of dental implant placement. Materials and Methods: A total of 56 individuals who underwent panoramic radiography and a CBCT evaluation before dental implant surgery were enrolled in the study. Measurements were performed to identify the shortest vertical distance between the alveolar crest and neighboring anatomical structures, including the maxillary sinus, nasal floor, mandibular canal, and foramen mentale. The differences between the measurements on panoramic radiography and CBCT images were statistically analyzed. Results: Statistically significant differences were observed between the measurements on panoramic radiography and CBCT for all anatomical structures (P<.05). The correlation coefficients (r) between the paired samples obtained from panoramic radiography and CBCT were closely correlated (P<.05), with r values varying from 0.921 and 0.979 for different anatomical regions. Conclusion: The results of this study support the idea that panoramic radiography might provide sufficient information on bone height for preoperative implant planning in routine cases or when CBCT is unavailable. However, an additional CBCT evaluation might be helpful in cases where a safety margin cannot be respected due to insufficient bone height.

Evaluating Accuracy according to the Evaluator and Equipment Using Electronic Apex Locators

  • Yu, Beom-Young;Son, Keunbada;Lee, Kyu-Bok
    • Journal of Korean Dental Science
    • /
    • 제13권2호
    • /
    • pp.52-58
    • /
    • 2020
  • Purpose: Using two types of electronic apex locators, this study aimed to investigate the differences in accuracy according to the evaluator and equipment. Materials and Methods: Artificial teeth of the lower first premolars and two mandibular acrylic models (A and B) were used in this study. In the artificial teeth, the pulp chamber was opened and the access cavity was prepared. Using calibrated digital Vernier calipers, the distance from the top of the cavity and the root apex was measured to assess the actual distance between two artificial teeth. The evaluation was conducted by 20 dentists, and each evaluator repeated measurements for each electronic apex locator five times. The difference between the actual distance from the top of the cavity to the root apex and the distance measured using electronic measuring equipment was compared. For statistical analysis, the Friedman test the Mann-Whitney U-test were conducted and the differences between groups were analyzed (α=0.05). Result: As for the accuracy of measurement according to the two types of electronic apex locators, the value of the measurement error was 0.4753 mm in Dentaport ZX and 0.3321 mm in E-Cube Plus. Moreover, electronic apex locators Dentaport ZX and E-Cube Plus showed statistically significant differences (P<0.05). As for the difference in the accuracy of the two types of electronic apex locators according to the evaluator, the resulting values differed depending on the evaluator and showed a statistically significant difference (P<0.001). Conclusion: Electronic apex locator E-Cube Plus showed higher accuracy than did Dentaport ZX. Nevertheless, both types of electronic apex locators showed 100% accuracy in finding the region within root apex ±0.5 mm zone. Furthermore, according to the evaluator, the two electronic apex locators showed different resulting values.