• Title/Summary/Keyword: Man Hour

Search Result 228, Processing Time 0.024 seconds

Improvement of Atmospheric Dispersion Assessment for Accidental Releases Using a Fuzzy Logic Inference Method (퍼지 논리 추론 방법을 이용한 사고시 대기확산 평가 개선)

  • Na, Man-Gyun;Sim, Young-Rok;Kim, Soong-Pyung
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.1
    • /
    • pp.19-26
    • /
    • 2001
  • In order to assess the atmospheric dispersion for the accidental releases of nuclear power plants, in calculating X/Q values in the XOQAR and PAVAN codes which are based on Reg. Guide 1.145, the X/Q and frequency values are plotted on log-normal paper. Starting with the highest X/Q value of this plot, the codes compare the slope of the line drawn from this point to every other point within an increment containing ten X/Q values. If there are fewer than ten values, only the number available are used. The coefficients that produce the line with the least negative slope are saved. The end point of this line is used as the next starting point, from which slopes to the points within the next increment, containing ten X/Q values, are compared. The X/Q values corresponding to the cumulative frequency values 0.5%, 5% or 50% are calculated to search for the $0{\sim}2$ hour X/Q value that tends to be a very conservative value. In this work, a fuzzy logic inference method is used for nonlinear interpolation of the X/Q values versus the cumulative frequency. The fuzzy logic inference method is known to be a food technique for nonlinear interpolation. The proposed method was applied to a potential accidential radioactive release of the Yonggwang nuclear power plant, which gives more realistic X/Q values.

  • PDF

Engineering Character of Ultra Rapid Hardening Concrete-Polymer Composite using CAC and Gypsum Mixed CAC (CAC 및 석고혼입 CAC를 사용한 초속경 콘크리트-폴리머 복합체의 공학적 특성)

  • Koo, Ja Sul;Yoo, Seung Yeup;Kim, Jin Man
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.2
    • /
    • pp.97-105
    • /
    • 2016
  • Recently, application case of the ultra rapid hardening concrete-polymer composite(URHCPC) are increasing to repair for the deterioration of pavement. But it is a major disadvantage that the main material is expensive and has environmental load. For these reasons, the development of the economic, eco-friendly materials is needed. Calcium Aluminate Composite (CAC), produced by rapid cooling of atomizing method with molten ladle furnace slag, is a material capable of improving the economic feasibility and reducing the environmental load of URHCPC. In this paper, the properties of CAC and gypsum mixed CAC (GC) as alternative materials of RSC according to the types of polymer dispersion were studied. The results were as follows; compressive strength, tensile strength, flexural strength, bonding strength and modulus of elasticity of the composites using CAC or GC showed higher values than those of plain proportion in 3 hour. In later age, they were at the same level as the general proportions. URHCPC using BPD as polymer dispersion had superior strength properties generally. But modulus of elasticity was the same level as the case of using a SBR latex. According to these results, CAC or GC can partially substituted for RSC to product the URHCPC. When URHCPC uses the BPD as the polymer dispersion, it can be improved performance.

Correlation between Deoxycytidineuria and CdR-aminohydrolase Activity following X-Irradiation (X線照射에 따르는 Deoxycytidineuria와 CdR-aminohydrolase의 活性變化와의 連關性)

  • Man Sik kang;Rhee, Juong-Gile;Cho, Joong-Myung
    • The Korean Journal of Zoology
    • /
    • v.18 no.4
    • /
    • pp.163-172
    • /
    • 1975
  • This work was undertaken to elucidate some aspects of mechanisms underlying the increased deoxycytidineuria following irradiation in the mice, by observing Dische-positive substances liberated from thissues, the activity of CdR-aminohydrolase of tissues and the CdR excreted in the urine at various times after single whole-body exposure to 400 and 800 R of X-rays. The activity of CdR-aminohydrolase declined markedly at 1 hour in the small intestine and liver, followed by a gradual rise reaching a maximum at 3 days after irradiation. In the case of the spleen and blood, however, only a trace of activity was observed in the control and irradiated animals. The amount of Dische-positive substance liberated from the small intestine postirradiation was elevated from 3 to 12 hours, showing a maximum during 6 to 9 hours after irradiation. On the contrary, the activity of the enzyme in the liver, spleen and kidney was less than one twentieth that of the small intestine, suggesting a prediction that these organs are not attributable to the increased deoxycytidineuria. A maximum deoxycytidineuria was exhibited at 9-12 hours period, attributed a large amount of CdR to the small intestine, which might correlate with the change in the CdR-aminohydrolase activity. Radiation-induced CdR seems to be liberated from the small intestine into the blood when the CdR-aminohydrolase activity declines abruptly. Then, the CdR is rapidly subjected to a filtration in the kidney without undergoing a further degradation pathway in the blood.

  • PDF

Effect of Band Spotty Fertilization on the Yield and Growth of Peanut(Arachis hypogaea L.) in Plastic Film Mulching Cultivation (비닐피복 땅콩 재배시 생육 및 수량에 미치는 국소시비 효과)

  • Yang, Chang-Hyu;Yoo, Chul-Hyun;Shin, Bok-woo;Cheong, Young-Keun;Kang, Seung-Won
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.5
    • /
    • pp.298-302
    • /
    • 2006
  • This study was carried out to establish low-input fertilization and seeding technique using the simultaneous with seeding and fertilizer application machine and band spotty applicator which were manufactured for experiment during cultivation of mulching for peanut(Arachis hypogaea L.). The labor hour for seeding by simultaneous with seeding and fertilizing machine was appeared over 90% reduction effect compared with control plot($17.3hr\;10a^{-1}$). In band spotty fertilization plots, the emergence date was delayed about 4 days and the seedling stand rate was decreased 11~18% compared with control plot(man power). The content of total nitrogen of soil after experiment was increased while the contents of organic matter, available phosphate and exchangeable potassium were decreased than before experiment. The content of nitrogen forming nitrate was increased in band spotty fertilization(BSF) plots by increasing the amount of applied fertilizer from early growth stage till the middle growth stage. Growth rate was increased in band spotty fertilization plots and the absorbed amount of phosphate and potassium for peanut were increased in 70% band spotty fertilization plot compared with control plot. Yield of peanut was increased 70% in band spotty fertilization plot due to high pod kernel ratio and ripened pod rate compared with control plot($3,150kg\;ha^{-1}$). It was found that 70% band spotty fertilization was more effective as fertilization method to reduce both environmental pollution and chemical nitrogen fertilizer in plastic film mulching cultivation of peanut.

Deep Sedation with Sevoflurane in Patients with Double Outlet of Right Ventricle (양대혈관 우심실 기시 환아의 Sevoflurane을 이용한 깊은 진정 하 치과치료)

  • Hyun, Hong-Keun;Shin, Teo Jeon;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Kim, Hyun-Jeong;Seo, Kwang-Suk;Lee, Jung-Man;Shin, Soonyoung
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.12 no.2
    • /
    • pp.115-119
    • /
    • 2012
  • Double outlet of right ventricle (DORV) refers to a congenital heart disease in which pulmonary and systemic circulation originates from the right ventricle. In the patient with DORV, it is important to maintain the balance between pulmonary and systemic circulation in anesthetic management. A 4-year-old boy with DORV, who underwent a Blalock-Taussig shunt operation, was transferred to the clinic with a chief complaint of multiple caries. Due to poor cooperability, it was impossible to treat the caries without sedation or general anesthesia. We planned to sedate him with consideration with detrimental effects associated with positive pressure ventilation for dental treatment. After a prophylactic administration of antibiotics, sevoflurane was administered through T-cannula site. Throughout the treatment, His blood remained stable around 80/40 mmHg, oxygen saturation remained around 91%. After 3 hour of sedation with sevoflurane (end-tidal sevoflurane con 1-1.8 vol%), he fully regained consciousness, and discharged from hospital without complications. In case of DORV patient, deep sedation with sevoflurane may be used as effective method of behavioral management during dental treatment.

Evaluation of Ventilation Performance of a Residential Unit for Different Sampling Points through Actual Field Tests (실증실험을 통한 측정 위치에 따른 주거공간 환기성능 평가)

  • Kwag, Byung Chang;Lee, Soo Man;Kim, Gil Tae;Kim, Jong Yeob
    • Land and Housing Review
    • /
    • v.13 no.3
    • /
    • pp.93-106
    • /
    • 2022
  • Ventilation plays an important role in controlling indoor air quality. Due to the recent spread of infectious diseases such as COVID-19 and with people spending more time indoors, there's been increased attention on the importance of ventilation performance. In many countries, ventilation is regulated by airflow rates and the number of air changes per hour (ACH). However, airflow rates and ACH alone do not provide an accurate account of actual indoor pollutant removal and ventilation uniformity in a space. This study looked into the ventilation performance of an actual residential unit using several sampling points instead of basing it off of airflow and air change rates. Literature review was used to derive relevant influencing factors and the tracer gas dilution method was used for the field test. The study measured air velocity, age of air, and ventilation efficiency at several locations and compared them to the average value at the center of the test space to determine the differences in ventilation performance at the selected measurement points. The study showed that different sampling locations resulted in different ventilation values. Findings of this study will be used to develop an experimental procedure for evaluating indoor ventilation performance of actual residential spaces.

Effects of Combine Harvesting and Drying Methods on Grain Quality in Rice Cultivars (벼 품종의 콤바인 수확과 건조방법에 따른 미입질의 변화)

  • Lee, Ho-Jin;Seo, Jong-Ho;Lee, Un-Woong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.35 no.3
    • /
    • pp.282-286
    • /
    • 1990
  • Currently, mechanization and automation have been introduced into rice harvest and drying process due to the shortage of man power. After rice cultivars, Chucheong and Milyang #23 were cutted with manual method (H1) or harvested with combine (H2), the threshed grain were dried in natural sun-drying (D1), in natural air in-bin system (D2), or in contineous hot-air drier (D3). We have evaluated grain losses, operation hour, and grain quality on each harvest and drying methods. Shattering loss during harvesting with combine was not dirfered significant from that of manual method, but threshing loss was 1.2% higher in combine harvest than in manual. Operation hours required for combine harvest was 3.5 times faster than for manual, even without head threshing. There was a significant difference bel ween cultivars in harvesting loss, which Milyang #23, a Tongil rice had two times more grain loss than Chucheong, a Japonica rice. Drying hours required to reduce to 14% grain moisture content were ten days for H1D1, 5-9 days for H2 D1, 2-3 days for H2D2, and only 15 hours for H2D3, respectively. In grain quality, complete grain ratio after dehulling was decreased about four percent in H2D3 compared to H1D1. while it was lower in Milyang #23 than in Chucheong, Hot-air drier increased occurence of cracked and broken grain. Combine harvest increased significantly these incomplete grain ratio of :Milyang #23, but not Chucheong.

  • PDF

Evaluation of TVOC contribution from Raw materials of PVC wallpaper using the Headspace-SPME-GC/MS (HS-SPME-GC/MS 법을 이용한 PVC벽지 원자재의 TVOC 기여도 평가)

  • Jang, Mi-Ok;Jeong, Tak-Kyo;Jeong, Yung-Rim;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.488-495
    • /
    • 2007
  • A wallpaper having many surfaces in indoor is composed of various raw materials. In this study, TVOC contribution from raw materials of PVC wallpaper was evaluated by using headspace-solid phase microextraction (HS-SPME)-GC/MS. Samples were diluent, resin stabilizer, plasticizer, filler, blowing agent and PVC resin. 9 mL of each sample was put into 22 mL glass vial and they were equilibrated for 1 hour at $100^{\circ}C$. Headspace in vial was absorbed to $75{\mu}m$ Carboxen-PDMS fiber and analyzed by GC/MS. Aromatic compounds like a toluene, ethylbenzene and xylene, ketones compounds like a acetone, methoxyacetone and 2-butanone and alkane compounds like a nonane decane and undecane were identified from raw materials. And alcohol compounds like a ethanol and butanol and aldehydes were detected. TVOC emission of diluent, resin stabilizer, plasticizer, PVC resin, blowing agent and filler were $54.20{\mu}g/g$, $32.88{\mu}g/g$, $0.50{\mu}g/g$, $0.88{\mu}g/g$, $0.22{\mu}g/g$ and $0.11{\mu}g/g$, respectively. Contribution of TVOC emission of diluent, resin stabilizer and PVC resin that were concerned about add ratio were 0.708, 0.129, 0.115, respectively. In conclusion, it's necessary to reduce TVOC emission through improvement of diluent, resin stabilizer and PVC resin. Also, HS-SPME-GC/MS method which was developed in this study will be used for raw materials analysis effectively.

A Study on the Estimation of Change Orders Impact for the Public Construction (공공건설공사 설계변경에 따른 손실 추정에 관한 기초연구)

  • Lee, Min-Jae;Park, Bum-Jin;Im, Keon-Soon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3D
    • /
    • pp.363-369
    • /
    • 2008
  • Change is inevitable and is a reality of construction projects. Change adjustment includes the cost associated with materials, labor, etc. However, the actions of a contractor can cause a loss of productivity and furthermore can result in disruption of the whole project because of a cumulative or ripple effect. Because of its complicated nature, it becomes a complex issue to determine the cumulative impact (ripple effect) caused by single or multiple change orders. Furthermore, owners and contractors do not always agree on the adjusted contract price for the cumulative impact of the changes. What is needed is a reliable method to identify and quantify the loss of productivity caused by cumulative impact of change orders. This study survey the change orders data in domestic area for public construction and analyze to quantify change order impact. This study developed concepts of "%CO", "%Delta", "%T" to capture change order effect on project and search the relationships between them. Finally, this study find strong relationship between change order and loss.

Evaluation of Ventilation Performances for Various Combinations of Inlets and Outlets in a Residential Unit through CO2 Tracer-Gas Concentration Decay Method (CO2 추적가스 농도감소법을 이용한 공동주택의 급·배기구 조합에 따른 환기 성능 분석)

  • Sang Yoon Lee;Soo Man Lee;Jong Yeob Kim;Gil Tae Kim;Byung Chang Kwag
    • Land and Housing Review
    • /
    • v.14 no.4
    • /
    • pp.111-120
    • /
    • 2023
  • Indoor air quality has become increasingly important with the increase in time spent in residential environments, impact of external fine dust, yellow dust, and the post-COVID 19 pandemic. Residential mechanical ventilation plays a key role in addressing indoor air quality. The legal standard for residential air changes per hour in Korea is 0.5 ACH. However, there are no standards for the location of supply and return vents. This study atempts to analyze the impact of ventilation performance based on the location of supply and return vents. An experiment was conducted using the CO2 tracer gas concentration decay method in a mock-up house set inside a large chamber to minimize external influences. The experimental results indicated that the commonly used combination of 2 supply and 2 return vents in living room spaces had a lower mean age of air than the combination of 1 supply and 2 return vents. Using multiple supply and return vents had lower mean age of air than using just 1 supply and 1 return vent.