• 제목/요약/키워드: Malodor Removal

검색결과 33건 처리시간 0.023초

악취 발산감소를 위한 필터의 이용 효과 (Effect of Biofilter on Reducing Malodor Emission)

  • 김원영;정광화;노진식;김원호;전병수;류호현;전영륜
    • 한국축산시설환경학회지
    • /
    • 제4권2호
    • /
    • pp.161-166
    • /
    • 1998
  • Controlling malodor originating from livestock feces has become a major issue, due to its influence on the health of man and livestock, together with its influences on atmospheric pollution. In this study, Five types of biofilters filled with saw-dust, night soil, fermented compost, leaf mold and a mixture(a compound of night soil, fermented compost and leaf mold at the same rates, respectively) were manufactured and tested. To study the effect of the biofilter on reducing malodor in a composting facility and swine building, a pilot scale composting facility enclosed with polyethylene film was constructed. Swine feces was composted in the facility and malodorous gas generated from the decomposition of organic matter in the feces was gathered by vacuum pump. Each biofilter achieved 87∼96% NH3 removal efficiency. This performance was maintained throughout 10 days of operation. The highest NH3 removal efficiency was achieved by leaf mold on the first day of operation period. It reduced the concentration of NH3 by about 96%. Night soil and fermented compost showed nearly equal performance of 93 to 94% for 10 days from the beginning of operation. The mixture achieved the lowest NH3 removal efficiency. It reduced NH3 concentration by about 89∼94% for 10 days from the beginning of operation. However NH3 removal efficiency of each biofilter declined with the passage of operational time. After 30 days from the beginning of operation, NH3 removal efficiency of each biofilter of each biofilter was below 60%, respectively. The concentration of H2S and CH3-SH originating from compost were equal to or less than 5mg/l and 3mg/l, respectively. After passing throughout the biofilter, the concentration of H2S and CH3-SH were not detected.

  • PDF

악취 및 VOC를 함유한 폐가스의 바이오필터 처리: 2. 개선된 바이오필터설계에 의한 악취 및 VOC 제거거동 (Biofilter Treatment of Waste Air Containing Malodor and VOC: 2. Transient Behavior of Biofilter with Improved Design to Eliminate Malodor and VOC)

  • 이은주;임광희
    • Korean Chemical Engineering Research
    • /
    • 제51권1호
    • /
    • pp.136-143
    • /
    • 2013
  • 본 연구에서는 악취 및 휘발성 유기화합물(VOC)를 함유하는 폐가스 처리에 있어서 개선된 바이오필터시스템의 악취 및 VOC의 제거거동 및 제거효율 등을 관찰하고, 전통적 바이오필터의 경우의 악취 및 VOC의 제거거동 및 제거효율 등과 비교하였다. 개선된 바이오필터시스템 운전 1~7단계에서 바이오필터 유효높이 차이에도 불구하고 미생물 population 분포 차이로 인하여, 정해진 시간에 각 단에서 에탄올 농도 순서가 바뀌었다. 반면에 운전 8단계에서 폐가스의 개선된 바이오필터시스템으로의 공급방향들이 바뀌었을 때에 에탄올 농도가 높은 순서는 운전 1~7단계와 다르게 바이오필터의 유효높이가 낮은 순서와 일치하였다. 황화수소 경우도 마찬가지였으나 에탄올 경우와 비교하였을 때에 농도순서가 바뀐 단의 황화수소 농도의 차이는 매우 적었다. 바이오필터 운전 8단계에서 개선된 바이오필터시스템의 에탄올 제거효율은 약 96%로서 전통적 바이오필터반응기의 에탄올 제거효율인 94%보다 약 2% 증가하였다. 개선된 바이오필터시스템 처리가스의 황화수소 농도의 거동은 전통적 바이오필터반응기와 비슷하였으나 황화수소 처리농도가 더 낮았다. 운전 8단계의 개선된 바이오필터시스템의 황화수소제거효율은 전통적 바이오필터반응기의 황화수소 제거효율보다 약 2% 가량 높았다. 따라서 개선된 바이오필터시스템의 제거효율은 에탄올과 황화수소 경우에 전통적 바이오필터반응기보다 각각 2% 제고되었음이 관찰되었다.

악취 및 VOC를 함유한 폐가스의 광촉매 처리: 1. 처리효율에 대한 광촉매담체 다공성의 영향 (Treatment of Waste Air Containing Malodor and VOC: 1. Effect of Photocatalyst-carrying Media Porosity on the Photocatalytic Removal Efficiency of Malodor and VOC of Waste Air)

  • 이은주;박혜리;임광희
    • Korean Chemical Engineering Research
    • /
    • 제50권6호
    • /
    • pp.945-951
    • /
    • 2012
  • 광촉매반응기의 충전제로서 glass bead-광촉매담체를 control로 하고 다공성의 silica-based 광촉매담체를 사용하였을 때의 악취 및 VOC를 함유한 폐가스의 광촉매 처리효율에 대한 광촉매담체 다공성의 영향평가를 수행하였다. 다공성의 silica-based-광촉매담체의 광촉매 코팅량은 $1,716.3{\mu}g/cm^2$로서 nonporous glass bead(control)에 담지된 광촉매코팅량인 $670{\mu}g/cm^2$ 값의 약 250%이었다. Porous silica-based 담체가 충전된 광촉매반응기의 황화수소 및 톨루엔 제거효율은 각각 22% 및 82%로서, glass-bead 담체가 충전된 UV/광촉매반응기의 경우의 황화수소 및 톨루엔 제거효율인 각각 19% 및 53%와 비교하였을 때에 황화수소의 경우는 약 16% 증가하였고 톨루엔의 경우는 약 55% 증가하였다. 따라서 다공성의 silica-based 광촉매담체를 사용함으로써 황화수소와 톨루엔의 동시처리효율을 각각 제고하였고, 처리효율의 제고율은 황화수소보다 톨루엔의 경우가 3.4배 높았다.

악취 및 VOC를 함유한 폐가스의 광촉매 처리: 2. 광도의 폐가스 처리효율에 대한 영향 (Treatment of Waste Air Containing Malodor and VOC: 2. Effect of Light-intensity on the Photocatalytic Removal Efficiency of Malodor and VOC of Waste Air)

  • 이은주;임광희
    • Korean Chemical Engineering Research
    • /
    • 제50권6호
    • /
    • pp.952-959
    • /
    • 2012
  • 환형 광촉매반응기 외경지지체의 반사막에 의한 광촉매반응기시스템의 광도를 제고함으로써 개선된 광촉매반응기에 의한 악취성분 및 휘발성 유기화합물을 동시 포함한 폐가스의 처리를 수행하였다. 그리고 광도 제고가 각 운전조건에서의 폐가스처리효율에 미치는 영향을 조사하였다. 광촉매 코팅된 nonporous glass bead 담체와 porous silica-based 담체를 각각 광촉매반응기에 충전하였을 때에 반사필름이 부착된 개선된 광촉매반응기 외경에서 측정한 광도는, 반사필름이 부착되지 않아서 광도가 제고되지 않은 광촉매반응기보다 각각 30.1%와 28.5% 증가하였다. Porous silica-based 담체를 충전한 개선된 광촉매반응기의 제거효율에 대한 제고효과는 약 2~3%이었다. 그러나 glass-bead 담체를 충전했을 때에 개선된 광촉매반응기의 제거효율 제고효과는 미미하였다. Porous silica-based 담체가 충전된 개선된 광촉매반응기인 최적화 광촉매반응기의 경우의 황화수소 및 톨루엔 제거효율은 nonporous glass bead가 충전되고 반사막이 없는 광촉매반응기 경우의 제거효율인 각각 19%와 53%보다 각각 약 26%와 약 60%의 증가율을 보였다. 반사막 필름표면의 roughness가 종래의 상업용 거울의 roughness보다 4배 정도 컸으나, 향후 개선된 광촉매반응기의 반사막의 roughness를 개선할 경우에 광도 개선효과가 더욱 커져서 이에 따른 악취 및 VOC를 함유한 광촉매 처리효율이 더욱 제고되리라 예상된다.

항균작용을 가진 수종 한약재의 구취억제 효과 (Deodorizing Effect of Several Antibacterial Medicinal Herbs on Oral Malodor)

  • 김현경;박재우;윤성우;류봉하;김진성
    • 대한한의학회지
    • /
    • 제31권4호
    • /
    • pp.151-163
    • /
    • 2010
  • Objective: We investigated the oral malodor inhibitory effect of Scutellariae Radix (SR), Phellodendri Cortex (PC), Moutan Cortex (MTC) and Magnoliae Cortex (MGC) for the development of a gargle solution. Methods: 1. Against P. gingivalis and Pr. intermedia, the minimal bactericidal concentration (MBC) and the change of viable cells that were exposed to 1% each herbal extract were observed. 2. Deodorizing activity of 2% herbal extract and Garglin $Mint^{(R)}$ against methyl mercaptan were evaluated by gas chromatography (GC). 3. We used the salivary sediment system (SSS) as the malodor model. 4. The clinical examination was repeated 3 times by 2 subjects by $Halimeter^{(R)}$. Baseline VSC of each subject was measured. Then, the control subject gargled with cysteine for 30 sec. After 4 min, subjects would gargle for 30 seconds with herbal extracts (2%) and Garglin $Mint^{(R)}$. Subsequently, the concentration of VSC was measured at 0, 4, 8, 12, 16, 20, 40 and 60 minutes. Results: 1. Against P. gingivalis, MBC of SR, PC and MTC was 0.1%, and MBC of MGC was 1%. Removal time of P. gingivalis was as follows; 5 hr in MGC, 24 hr in SR and PC, and 48 hr in MTC. Against Pr. intermedia, MBC of SR and PC was 0.5%, and MBC of MTC, MGC was 1%. Removal time of Pr. intermedia was as follows; 5 hr in MTC and 24 hr in SR, PC and MGC. 2. Deodorizing effect of herbal extracts against methyl mercaptan was as follows; MGC and MTC had 100%, SR had 82.22%, PC had 66.60%, Garglin $Mint^{(R)}$ had 40.54%. 3. In the experiment using SSS, PC and MTC had statistically significant malodor-inhibitory effects (p<.05). 4. In the clinical examination, PC and MGC had statistically significant inhibitory effects at every elapsed time compared to the control subject. MTC had that until 40 min. SR had that at 0, 4, 8, 20, and 60 min. Conclusions: SR, PC, MTC and MGC have an antibacterial effect and the chemical removable activity of the oral malodor caused by VSC. These four herbs could have potential as effective anti-malodor agents.

A Study on the Odor Removal Control System of Sewage Sludge

  • KIM, Su-Hye;LEE, So-Hee;YUN, Yeo-Jin;CHOI, Soo-Young;JUNG, Min-Jae;KWON, Woo-Taeg
    • 웰빙융합연구
    • /
    • 제4권2호
    • /
    • pp.19-25
    • /
    • 2021
  • Purpose: The purpose of this study is to reduce odor complaints by identifying problems with odor management at the site of the water regeneration center and researching odor management methods. Due to the high population density of Korea, sewage treatment facilities are adjacent to residential and industrial areas. According to previous studies, the main malodor-emitting facilities of sewage treatment facilities were preliminary treatment facilities (2,220 times), sedimentation basins (4,628 times), and sludge treatment facilities (9,616 times). Research design, data and methodology: Compound malodors and designated malodor-producing substances were collected from five site boundaries of the water regeneration center and analyzed according to the official methods to test malodor, and a total of two times (August and September 2020) were conducted. Results: As a result of the measurement, in the green area in front of the center office, compound malodors were detected at a maximum of 8 times and at least 3 times during the dawn time. As for the designated malodor-producing substances, 0.1ppm of ammonia was detected in the green area in front of the center office and the park golf course. This is within 15 times the maximum allowable emission level of compound malodors and within 1ppm of the maximum allowable emission level of ammonia. Conclusions: Even if the dilution rate of the compound malodors did not exceed the maximum allowable emission level, the odor could be recognized, and more research is needed in the future to establish effective reduction measures according to the subjective and individual and seasonal odor characteristics.

의치장착자의 구취발생에 관한 연구 (A study of oral malodor of denture wearers)

  • 권택가;장경수
    • 구강회복응용과학지
    • /
    • 제17권2호
    • /
    • pp.85-90
    • /
    • 2001
  • In order to investigate the amount of oral malodor of denture wearers, concentration of volatile sulfur compounds of 20 denture wearers(10 male, 10 female) was measured by Halimeter(RH-17, Interscan, CA, USA) at following four conditions ; condition 1(with denture) : male - $415.0{\pm}90.1$, female - $430.9{\pm}101.3$ condition 2(immediately after denture removal) : male - $291.4{\pm}35.5$, female - $259.8{\pm}20.4$ condition 3(with denture after 30 minutes immersing in chlorhexidine) :male - $210.1{\pm}25.7$, 여자 - $197.4{\pm}22.2$ condition 4(with denture after 24 hours immersing in chlorhexidine) : male - $120.1{\pm}35.2$, 여자 - $109.2{\pm}20.0$ There was no sexual difference, but, value at the condition 1 showed statistically significant difference from the others(p<0.05). It is dentists' responsibility and privilege to understand and diagnose the strong association between mouth and oral malodor and treat it.

  • PDF

광촉매와 적외선을 이용한 악취저감 (Removing Malodor Using Photocatalyst and Infrared)

  • 전태영;김재용
    • 대한환경공학회지
    • /
    • 제36권8호
    • /
    • pp.528-533
    • /
    • 2014
  • 현재 사람들은 환경오염에 대한 관심이 많으며 각종 오염물질로 오염된 실내의 공기질을 향상시키고자 노력한다. 건강하고 쾌적한 생활환경을 조성하는 것은 매우 중요한 문제다. 본 연구에서는 공기정화분야에서 최초로 녹색기술 인증을 받은 기술을 사용하여 실내공기오염의 주범인 악취물질의 제거 효율을 향상시키고자 하였다. 이 녹색기술은 광촉매를 사용한 기존의 공기정화 시스템에 적외선램프를 사용하여 오염원인 물질들과 OH라디칼의 반응성을 높여 산화반응이 보다 쉽게 일어나도록 한 기술이다. 기존의 공기정화기와 비교하여 적외선램프를 부착한 녹색기술의 효율을 평가하였을 때, 오염원인물질의 초기 농도와 원인물질 종류에 따라 분해 효율의 차이가 나타났다. 저농도의 경우 16.9%의 제거효율 향상이 관찰되었고, 고농도의 경우 13.2%의 제거효율이 향상되었다.

가축분뇨 슬러리 액비 부숙 조건별 특성비교 (Comparison of Liquid Composting Efficiency using Liquid Pig Manure in Different Condition)

  • 정광용;조남준;정이근
    • 한국환경농학회지
    • /
    • 제17권4호
    • /
    • pp.301-305
    • /
    • 1998
  • 본 연구는 농가에서 사용하는 저류조, 연속 폭기조, 혐기성 정치식, 혐기성 교반식의 4가지 형태의 부숙조를 이용하여 액상 가축분 퇴비 부숙효율을 평가하기 위하여 수행하였다. 호기성 폭기조는 BOD 및 악취 제거율에서 혐기성 부숙방법보다 우수하였다. 반면에 질소는 초기농도의 47%가 손실되어 혐기성 부숙방법보다 심한 편이었다. 혐기성 부숙방법중 교반식과 정치식간에는 큰 차이는 인정되지 않았다. 그러나 혐기성 교반식이 정치식보다 대장균 제거율, 악취제거율은 더 높았으며, 질소 손실율은 더 낮게 나타났다. 농가에서 사용하는 저류조 형태의 부숙조는 혐기 또는 호기성 처리 방법보다 BOD, 대장균, 악취제거율등이 낮았다. 각 개별요인들의 효율을 종합 평가한 결과 액비 부숙효율은 혐기성 교반조>호기성 폭기조>무교반 혐기성조>저류조 순으로 높았다.

  • PDF