• Title/Summary/Keyword: Malfunctioning

Search Result 124, Processing Time 0.027 seconds

A Study on the Usefulness of Development of a Steam Sterilizer Equipped with an Electronic Bowie-Dick Test System

  • Bae, Young Ok;Hwang, Jun Soo;Kim, Sung Il;Lee, Joon Ha
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.156-163
    • /
    • 2017
  • To verify the usefulness of a steam sterilizer equipped with an electronic Bowie-Dick test system, this study was carried out using two methods, utilizing both a steam sterilizer and an electronic Bowie-Dick tester. The first method is to confirm the error detection of the chemical Bowie-Dick test pack and the electronic Bowie-Dick tester in a malfunctioning sterilizer environment. For this purpose, the Bowie-Dick test program for the steam sterilizer was used to test three types of test packs commonly used in hospitals and the electronic Bowie-Dick tester by changing the set values of temperature, time, and vacuum frequency. The second is an experiment to check the sterilizer's normal operation with the electronic Bowie-Dick tester and the usefulness of grasping the cause of the malfunction. The results showed that the sterilization temperature was the same as that of the test pack at a temperature $1{\sim}6^{\circ}C$ lower than the reference temperature of $134^{\circ}C$. In the test with the sterilization exposure time as a variable, there was a normal discoloration at a time difference of 30~90 s. In the experiment using the number of vacuum cycles, the test was correct by performing the normal discoloration only at the normal condition of 3 times. The test results of 30 hospitals were 100 failure tests by a total of 291 Bowie-Dick tests. Of these, the failure factors related to an internal temperature that the chemical test packs could not detect were the greatest, and the four factors related to temperature, including the internal temperature, were found to be 71.18% of total malfunctions. In addition, the Bowie-Dick tester was provided within 30 min after the start of the Bowie-Dick test to confirm the performance of the sterilizer and the detailed cause. A steam sterilizer equipped with an electronic Bowie-Dick test system is used to manage individual sterilizers. In the current steam sterilizer with many temperature-related errors, it is possible to check the malfunction of the temperature difference that the test pack cannot detect, and the cause of error for the sterilizer is immediately detected after the test. The steam sterilizer equipped with the electronic Bowie-Dick test system assists with infection control with accurate sterilizer performance assurance.

The Literatual Study on Pathologic Change Cognition to the Liver Disease (간장의 병리변화 인식에 대한 문헌적 고찰)

  • Lee Young Su;Kwack Jeong Jin;Lee Gang Nyoung;Choi Chang Won;Kim Hee Chul
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.4
    • /
    • pp.630-636
    • /
    • 2002
  • After The Yellow Emperor's Canon of Internal Medicine, The text researches of pathologic change to the liver disease concluded the next, 1, The category of liver-disease(肝病) include the Symptoms of abnormality due to vital energy and blood motion, emotion and intention, muscular and reproductive function, and legions around descending liver channel. 2. In the theory that Liver-Yang energy(肝陽氣) is always overproducing, Liver-Yin blood(肝陰血) is always lacking, pathologic characteristics for liver disease is functional change of malfunction of the use of body(體用失調), So nourishing the liver and kidney is used for the principal aspects of a disease. regulating and calm the liver is used for the secondary aspects of a disease as the treatment plan, 3. If malfunctioning of the functions of dispersion and discharge(疏泄), Iiver-energy(肝氣) is becoming degected, So overproduct and overflow of ascent and exhalation of liver-yang(肝陽) is becoming blood are ascending following energy. complete usage of Yin-blood(陰血) is responsible for some kinds of mass formed by blood stasis in the early stage of pathogenesis of liver disease syndrome of the energy system as the progession of disease extravasated blood is forming. the pathologic characteristics is appeared loss of control of the vital energy and blood(體用失調) at the liver disease. 4. Sthenia-syndrome of liver(肝實證) and liver-heat syndrome(肝熱證) is appered that overproducing and overflow of dispersion(疏泄太過) and discharge is responsible for overfunctioning of liver disease or some kinds of heat syndrome such as liver fire(肝火), Sthenia of liver-yang(肝陽上亢), the syndromes of sthenic liver heat(肝實熱) are appered. deficiency of the liver(肝虛證) and cold syndrome of liver(肝寒證) is classified pathologic characteristics of cold and heat, deficiency and excess that regression of sensory, motor, mental due to lack of dispersion and discharge(疏泄不及), or intruding of the cold miasma, are degected. 5. The liver is close relation of physiologic function and internal organ such as spleen, stomach, lung, heart, kidney, gall bladder by the meridian channels, because of property of wind Zang, rapid progession is classified by phthologic charateristics.

Design of Vision Based Punching Machine having Serial Communication

  • Lee, Young-Choon;Lee, Seong-Cheol;Kim, Seong-Min
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2430-2434
    • /
    • 2005
  • Automatic FPC punching instrument for the improvement of working condition and cost saving is introduced in this paper. FPC(flexible printed circuit) is used to detect the contact position of K/B and button like a cellular phone. Depending on the quality of the printed ink and position of reference punching point to the FPC, the resistance and current are varied to the malfunctioning values. The size of reference punching point is 2mm and the above. Because the punching operation is done manually, the accuracy of the punching degree is varied with operator's condition. Recently, The punching accuracy has deteriorated severely to the 2mm punching reference hall so that assembly of the K/B has hardly done. To improve this manual punching operation to the FPC, automatic FPC punching system is introduced. Precise mechanical parts like a 5-step stepping motor and ball screw mechanism are designed and tested and low cost PC camera is used for the sake of cost down instead of using high quality vision systems for the FA. 3D Mechanical design tool(Pro/E) is used to manage the exact tolerance circumstances and avoid design failures. Simulation is performed to make the complete vision based punching machine before assembly, and this procedure led to the manufacturing cost saving. As the image processing algorithms, dilation, erosion, and threshold calculation is applied to obtain an exact center position from the FPC print marks. These image processing algorithms made the original images having various noises have clean binary pixels which is easy to calculate the center position of print marks. Moment and Least square method are used to calculate the center position of objects. In this development circumstance, Moment method was superior to the Least square one at the calculation of speed and against noise. Main control panel is programmed by Visual C++ and graphical Active X for the whole management of vision based automatic punching machine. Operating modes like manual, calibration, and automatic mode are added to the main control panel for the compensation of bad FPC print conditions and mechanical tolerance occurring in the case of punch and die reassembly. Test algorithms and programs showed good results to the designed automatic punching system and led to the increase of productivity and huge cost down to law material like FPC by avoiding bad quality.

  • PDF

Automatic On-Chip Glitch-Free Backup Clock Changing Method for MCU Clock Failure Protection in Unsafe I/O Pin Noisy Environment (안전하지 않은 I/O핀 노이즈 환경에서 MCU 클럭 보호를 위한 자동 온칩 글리치 프리 백업 클럭 변환 기법)

  • An, Joonghyun;Youn, Jiae;Cho, Jeonghun;Park, Daejin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.12
    • /
    • pp.99-108
    • /
    • 2015
  • The embedded microcontroller which is operated by the logic gates synchronized on the clock pulse, is gradually used as main controller of mission-critical systems. Severe electrical situations such as high voltage/frequency surge may cause malfunctioning of the clock source. The tolerant system operation is required against the various external electric noise and means the robust design technique is becoming more important issue in system clock failure problems. In this paper, we propose on-chip backup clock change architecture for the automatic clock failure detection. For the this, we adopt the edge detector, noise canceller logic and glitch-free clock changer circuit. The implemented edge detector unit detects the abnormal low-frequency of the clock source and the delay chain circuit of the clock pulse by the noise canceller can cancel out the glitch clock. The externally invalid clock source by detecting the emergency status will be switched to back-up clock source by glitch-free clock changer circuit. The proposed circuits are evaluated by Verilog simulation and the fabricated IC is validated by using test equipment electrical field radiation noise

Analysis of GPS signal environment at DGNSS stations (DGNSS 기준국 관측환경 분석)

  • Sohn, Dong-Hyo;Park, Kwan-Dong;Won, Ji-Hye;Choi, Yong-Kwon;Kee, Chang-Don
    • Journal of Navigation and Port Research
    • /
    • v.35 no.8
    • /
    • pp.625-629
    • /
    • 2011
  • In this study, we analyzed the signal environment of 17 DGNSS stations operated by DGPS Central Office through TEQC quality checking, visibility analysis and site visits. With TEQC, we produced times series of four indices of TEQC quality checking: observation ratio, L1 pseudorange multipath, L2 pseudorange multipath, and the frequency of cycle slip events. From visibility analysis, the directions where missing observations are happening were identified and the result was verified through onsite investigation. Without considering TEQC indices at the six sites(Palmido, Eochungdo, Geomundo, Pyeongchang, Seongju, and Chungju), the average TEQC indices were: 98% observation ratio, 0.19m of L1 pseudorange multipath, 0.71m of L2 pseudorange multipath, and 1.3 cycle slips per 1000 observations. The observation ratios at Palmido and Eochungdo were low. It was found that receiver settings were incorrect so that they could track the P2 signal of GPS satellites with L2C capability. No signal-blocking obstacles were found around the Geomundo station except the lighthouse. Thus, we guess that the poor TEQC indices at the site are believed to be caused by problems in the GPS hardware or cables. The low observation ratio at Pyeongchang is being caused by the surrounding hills blocking the satellite view from the south to the northwest directions. Even though all of four TEQC indices were bad at Seongju and Chungju stations, we found that the signal reception environment at the two sites is in good condition. We think that the quality indices got poor probably because of malfunctioning equipment. So, further investigation is needed for the Seongju and Chungju sites.

Dynamic Analysis of 3 Different Cross-Sectional Shapes of a Fill Dam using 3D FEM Analysis (3차원 유한요소해석에 의한 필 댐의 3가지 단면 형상을 고려한 지진해석)

  • Choi, Byoungil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.8
    • /
    • pp.37-43
    • /
    • 2015
  • Dam movements are identified in real-time with measuring instruments for dam maintenance. However, for dams that have aged, the measuring instruments that were installed during the dam construction are frequently malfunctioning or completely failing altogether. Precision safety diagnosis is being executed for dams that are national facilities Type 1. During the diagnosis, a safety assessment is conducted for the dam body. Normally, during the analysis of dam safety, the widest cross-section is selected and a two-dimensional numerical analysis is taken place for the cross-section. However, numerous researchers have recently looked into applying the 3-dimensional numerical analysis program developments to precisely analyze the structure of the dam, as well as the surrounding strata, and the lower dam strata. In this study, PLAXIS 3D, a geotechnical generic FEM analysis program, was used to conduct dam safety assessments for earthquakes. The following were compared and analyzed: considering the seismic properties of the dam body with all zoned structures reflected as one rock-fill zone together with the dam body, considering the dam body as the rock-fill zone and the core zone, and the numerical analysis results. Thus, the study was aimed to analyze the impact properties of seismic waves according to the different zones.

Development and Safety Evaluation of Earth Leakage Alarm Breaker Equipped with Fire Current (IGR) Alarming Function (화재전류(IGR) 경보 기능이 내장된 누전경보차단기의 개발 및 안전성 평가에 관한 연구)

  • Ko, Wan-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.43-48
    • /
    • 2020
  • The purpose of this study is to develop an earth leakage alarm circuit breaker, equipped with a leakage alarming function (JER-E2S, ETECKOREA Co., Korea), and to analyze its characteristics. The developed mechanism is exclusively used for single-phase and 220 V circuits, with a rated current of 32 A, 20 A, 20 A (for restrooms), 16 A, etc. It satisfies all characteristics of existing earth leakage circuit breakers (ELB). If a fire current, which is a resistive leakage current (Igr), flows through an electric line, the device detects the leakage current in real time and warns against the leakage through a blinking LED lamp. Since the developed device displays a tolerance to a capacitative leakage current (Igc) that inevitably occurs in LED lamps, communication devices, etc., it ensures a stable power supply. In addition, the earth leakage alarm circuit breaker protects against power failure due to a momentary ground fault. Therefore, it can supply power without the risk of the circuit breaker malfunctioning due to a momentary ground fault caused by water droplets, leaves, etc. Moreover, with a standby power of less than 0.1 W, the developed earth leakage alarm circuit breaker exhibits a power saving performance that is 3~8 times greater than that of other ELBs. Installation of approximately 10 earth leakage alarm circuit breakers in one apartment household, with an area of 120 ㎡, can save 2~5 kWh per month. Therefore, the developed earth leakage alarm breaker not only satisfies the characteristics of existing earth leakage breakers, but also exhibits outstanding power supply quality since it has the functions of electric fire prevention and malfunction prevention. Therefore, this device can innovatively contribute to electric fire prevention.

Comparative Experiments for the Improvement of NDGPS Signal Quality (NDGPS 관측자료의 품질향상을 위한 비교실험)

  • Sohn, Dong-Hyo;Park, Kwan-Dong;Kim, Hye-In;Kim, Du-Sik;Kee, Chang-Don
    • Journal of Navigation and Port Research
    • /
    • v.36 no.8
    • /
    • pp.625-630
    • /
    • 2012
  • The DGNSS Central Office operates 17 DGNSS reference stations. Compared to the other DGNSS sites, the TEQC data quality of some sites is poorer. In this study, we tried to find out the causes that degrade the quality of GPS data for the purpose of improving the signal quality of the DGNSS stations. We selected the Chungju station that is the one of those stations with bad data quality. Through the on-site visit, we found that there is no signal-blocking obstacles. In addition to site surveys, we conducted two experiments; simultaneous observation considering environmental factors and comparison test through equipment replacements to check the malfunctioning of GPS equipments. In the simultaneous test results, we realized that environmental factors do not induce any bad effects on the data quality. In equipment replacement experiments, we confirmed that the data quality is of excellent quality when the test receiver was used instead of the original one installed at the site. When we replaced the antenna instead of the receiver, the data quality was bad. Through those two experiments, we concluded that the receiver is the main factor that degrades the signal quality.

Investigation on Design Aspects of the Constructed Wetlands for Agricultural Reservoirs Treatment in Korea (농업용 저수지 수질개선을 위한 국내 인공습지 설계 및 시공실태 조사)

  • Kim, Youngchul;Choi, Hyeseon;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.23 no.2
    • /
    • pp.189-200
    • /
    • 2021
  • To improve the water quality of agricultural reservoirs, constructed wetlands are applied in many places. These are technologies that establish ecosystems and important design factors include water depth distribution, inflow and outflow, water flow distribution, hydraulic residence time, water quality treatment efficiency, aspect ratio, and the distribution of open water and covered water surfaces. For high efficiency during the operation of a constructed wetland, the design needs to be optimized and this requires consideration of the different types and length of the intake dam as well as the type and connection of wetland cells. Therefore, this study was conducted to investigate and suggest factors that needs to be considered during the design and for efficient operation measures through field surveys of 23 constructed wetlands that have been established and operated in agricultural reservoirs. Results of the field investigation shows that several sites were being operated improperly due to the malfunctioning or failure of the water level sensors, sedimentation in the intake dam, and clogging of the mechanical sluice frames. In addition, it was found that as the length of the inlet channel increases, the ecological disconnection between the intake dam upstream and the wetland outlet downstream also increases and was identified as a problem. Most of the wetlands are composed of 2 to 5 cells which can result to poor hydraulic efficiency and difficulty in management if they are too large. Moreover, it was found that the flow through a small wetland can be inadequate when there are too many cells due to excessive amounts of headloss.

The Status of Endangered Plants Distributed in the Middle Eastern Area of Korea and Evaluation of the Risk Factors (우리나라 중동부지역에 분포하는 멸종위기야생식물 현황과 위험요인 평가)

  • Kim, Young-Chul;Chae, Hyun-Hee;Hong, Bo-Ram;Oh, Hyun-Kyung;Lee, Kyeong-Hwa;Lee, Kyu-Song
    • Korean Journal of Environment and Ecology
    • /
    • v.30 no.3
    • /
    • pp.291-307
    • /
    • 2016
  • Evaluation of the extinction risk of endangered plants at international, national as well as at regional levels is essential to the implementation of plans for direct conservation activities. Reports indicate that 34 endangered plants are distributed in the middle eastern area of Korea. For each endangered plant, we investigated the sites, area of extents, population size, and factors that affect population extinction. We assessed risk factors based on 10 evaluation criteria including the results from the investigation and the life traits each endangered plant has. As a result of evaluating the risk factors, these 34 endangered plants are classified into 3 groups: the first category comprises 12 endangered plants that require active and urgent conservation of habitats due to multiple risk factors; the second group has 16 endangered plants that should be able to persist with the removal of a few direct risk factors; the third category has 6 endangered plants that can persist with minimal management due to comparatively large distributed area and numerous individuals. It was found that most major risk factors in the population of endangered plants are caused by disruption of habitats and population extinction due to the increase of human habitation in the concerned areas, development and illegal harvesting. Futhermore, ecological collapse from decreasing habitats and malfunctioning mechanism of extinction and regeneration due to the changes of vegetational environment can be the other causes. From the area of the present investigations, we selected 5 regions according to the number of species and the frequency of appearance and importance of conservation measures. Also, we suggested a conservation strategy according to the regional characteristics. We suggest that the method for evaluating extinction risk of endangered plants includes distributional data and life traits of species. In addition, we underscore the necessity for understanding population dynamics and ecological niche of the each target species.