• 제목/요약/키워드: Malfunction Panel

검색결과 11건 처리시간 0.023초

OLED display device의 Line Defect 시험법에 관한 연구 (A Study on OLED display device's line defect test methode)

  • 최영태;조재립
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2009년도 춘계학술대회
    • /
    • pp.523-529
    • /
    • 2009
  • The ACF(Anisotropic Conductive Film) is used for bonding Drive IC and OLED display device panel. If ACF bonding process is problem, a malfunction of line defect can occur. Because electric resistance increase between the panel and drive IC after a period of time, drive IC can not supply enough current to the panel. This paper is studied on a method of test for line defect.

  • PDF

공동주택의 승강기 설비에 대한 오동작 원인 조사 및 고찰 (The Cause Analysis and Research of Malfunction for Elevator Equipment of the Apartment House)

  • 김기현;방선배;김종민;배석명;김재철
    • 조명전기설비학회논문지
    • /
    • 제20권4호
    • /
    • pp.65-71
    • /
    • 2006
  • 승강기 설치는 매년 약 15,000여 대씩 증가하고 있다. 승강기 증가에 따른 인명 사고 발생 및 갇힘, 급상승, 급정지, 층 표시 오류 등 승객의 불안감을 유발시킬 수 있는 오동작 사고가 크게 증가 하고 있다. 따라서 본 논문에서는 이런 오동작 및 고장이 승강기 전원품질과 어느 정도 연관성이 있는지를 조사하기위해 승강기 보수업체의 승강기 보수일지 및 공동주택 관리소에서 관리하고 있는 승강기 보수일지와 2004년도 119 구조대가 승강기 갇힘 사건에 대해 구조한 장소에 설문조사를 토대로 사고 발생 시간, 오동작 형태 및 원인에 대해서 조사 분석하였다. 분석 결과는 119 구조건수에 대해 단순 전원 리셋으로 재가동된 경우가 전체 24[%]를 차지하고, 갇힘 원인별 분류로 판별하면 단순 정전이 8.2[%]를 차지하는 것으로 조사 되었다. 분석 결과는 현장 전원 품질 측정 및 모의시험을 통하여 승강기 전기적 장해에 대한 상호 연관성을 분석하는데 자료로 이용될 것이다.

Automatic Detection of Malfunctioning Photovoltaic Modules Using Unmanned Aerial Vehicle Thermal Infrared Images

  • Kim, Dusik;Youn, Junhee;Kim, Changyoon
    • 한국측량학회지
    • /
    • 제34권6호
    • /
    • pp.619-627
    • /
    • 2016
  • Cells of a PV (photovoltaic) module can suffer defects due to various causes resulting in a loss of power output. As a malfunctioning cell has a higher temperature than adjacent normal cells, it can be easily detected with a thermal infrared sensor. A conventional method of PV cell inspection is to use a hand-held infrared sensor for visual inspection. The main disadvantages of this method, when applied to a large-scale PV power plant, are that it is time-consuming and costly. This paper presents an algorithm for automatically detecting defective PV panels using images captured with a thermal imaging camera from an UAV (unmanned aerial vehicle). The proposed algorithm uses statistical analysis of thermal intensity (surface temperature) characteristics of each PV module to verify the mean intensity and standard deviation of each panel as parameters for fault diagnosis. One of the characteristics of thermal infrared imaging is that the larger the distance between sensor and target, the lower the measured temperature of the object. Consequently, a global detection rule using the mean intensity of all panels in the fault detection algorithm is not applicable. Therefore, a local detection rule was applied to automatically detect defective panels using the mean intensity and standard deviation range of each panel by array. The performance of the proposed algorithm was tested on three sample images; this verified a detection accuracy of defective panels of 97% or higher. In addition, as the proposed algorithm can adjust the range of threshold values for judging malfunction at the array level, the local detection rule is considered better suited for highly sensitive fault detection compared to a global detection rule. In this study, we used a panel area extraction method that we previously developed; fault detection accuracy would be improved if panel area extraction from images was more precise. Furthermore, the proposed algorithm contributes to the development of a maintenance and repair system for large-scale PV power plants, in combination with a geo-referencing algorithm for accurate determination of panel locations using sensor-based orientation parameters and photogrammetry from ground control points.

평판디스플레이의 대기중 분진농도에 따른 수명예측 시험방법 개발 (Development of Test Method for Flat Panel Display Life Time Prediction during Atmospheric Particle Exposure)

  • 유동현;이건호;최정욱;안강호
    • 반도체디스플레이기술학회지
    • /
    • 제12권4호
    • /
    • pp.45-48
    • /
    • 2013
  • The electronic device, such as flat panel display (FPD), is very important in our life as a means of communication between humans. Liquid crystal display (LCD), which is categorized as a flat panel display, has been used in many display products, especially in TV industry. An LED TV is composed of several electrical components, such as liquid critical module (LCM), analog to digital convertor (AD), power supplier, and inverter board. These modules are very vulnerable to particulate contamination, and causing malfunction or visibility degradation. In this study, we developed a test method for prediction of LCM's lifetime. The test system consists of carbon particle generation flame, dilution system, test chamber, and particle concentration monitoring instrument. Since the carbon particles are the most abundant in the atmosphere and easily absorb light, soot particles are used as a challenging material for this test. The concentration of generated soot particles is set around 4,000,000 #/cc, which is 400 times higher than that of usual atmospheric particles. Through this experiment, we deduced the relationship between the dust concentration and life time of the test specimen.

공기부상 FPD 이송장치에서 다공질판과 글래스 사이의 공기유동 해석 (Air Fluid Analysis between Porous PE-Plate and Glass in Air-Floating FPD Conveyor System)

  • 노태정;손태영
    • 한국산학기술학회논문지
    • /
    • 제9권4호
    • /
    • pp.878-885
    • /
    • 2008
  • 최근에 많은 수요와 각광을 받고 있는 디스플레이 장치에서 CRT는 곡면이며 무겁고 큰 부피 때문에 LCD, PDP, OLED와 같은 평판디스플레이(FPD)로 대체되고 있다. FPD는 $0.6\sim0.8mm$ 두께의 대면적 글래스에 여러 공정을 거친 후에 최종 제품 규격으로 절단하여 제작하기 때문에 글래스의 면적이 크면 클수록 FPD의 생산성이 높다는 밀접한 관계를 갖는다. 따라서 FPD 제조 업계에서는 글래스 면적을 증가시키기 위하여 노력하고 있으며, 예를 들면, 현재 8세대 LCD인 경우 약 $2,200mm\times2,600mm$의 면적을 가진다. 이러한 글래스를 이송하는 대표적인 장치로서 공기부상 컨베어시스템은 압축공기를 이용해서 FPD용 대면적 글래스 등을 약 $0.3\sim0.5mm$ 정도 부상시켜 비접촉으로 이송할 수 있는 장치이다. 이 때 글래스와 다공질판 표면 사이의 공기 유동이 모델링되고 해석되며, 이것으로부터 글래스의 공기부양 조건이 예측될 수 있다. 글래스를 이송시 전기공급 중단에 의하여 압축공기가 공급되지 않아 부상판과 접촉이 발생하였을 때, 자기윤활 특성을 가진 다공질판 위의 글래스는 1mm 홀을 많이 가진 사각덕트 부상판 위의 글래스와 조사, 비교된다.

단열재 개선을 통한 PKG-A Water Jet Room 온도저감 연구 (A Study on the Internal Temperature Reduction of PKG-A Water-jet-room by Substituting Heat Insulation Materials)

  • 정영인;최상민
    • 품질경영학회지
    • /
    • 제47권3호
    • /
    • pp.425-435
    • /
    • 2019
  • Purpose: The purpose of this study was to resolve the Naval ship's Local Operation Panel(LOP) malfunction problems which caused by overheating in summer season and dispatching to equatorial regions. Methods: Instead of using dual type heat insulation materials(consist with ceramic wool and glass wool), aerogel heat insulation materials were used for decreasing heat emissions from gas-turbine heat waste steam pipes passing water-jet- room. Experiment and Computational analysis of heat flow were conducted to analyze the internal room temperature changes. Results: The results of this study are as follows; The aerogel heat insulation materials suppress heat emission more efficiently than dual type insulation materials. The cold surface temperature of insulation was far more decreased and internal room, LOP surface temperature also showed significant results too. Conclusion: The substituted heat insulation materials appeared remarkable performance in decreasing room temperature that it could be used for suppressing the LOP overheatings and malfunctions.

펄스 출력 구현이 가능한 디지털 제어의 SCR형 CO2 용접시스템의 개발 (Development of Digital controlled SCR type CO2 Welding System for Implementation Pulse Output)

  • 은종목;최규하
    • Journal of Welding and Joining
    • /
    • 제32권1호
    • /
    • pp.102-107
    • /
    • 2014
  • SCR(Thyristor) type $CO_2$ welders have widely used for the welding process of heavy industries such as shipbuilding and plant. Since the industrial fields of shipbuilding and plant are usually exposed to severe welding condition with lots of dust, extreme temperature, high humidity and vibration, it is not recommended to use inverter type welder despite its state-of-the-art technology. Many sophisticated functions in the inverter welder may not work due to malfunction of its sensitive components. Hence this study focused on digitalization of SCR $CO_2$ welder by making use of microprocessor for SCR phase control. By this application, fine control of output of the $CO_2$ welding systems is achieved. Also pulse output mode of operation is realized and its verification is carried out with aluminum sample welding. The experimental results showed sound weld bead. The front operation panel provide user with numerical parameter settings and monitors. It will help precise weld process monitoring and control with digital value.

누전차단기 동작시간 및 부동작 전류 특성 (A Study on the Cutoff time and the Malfunction Current Characteristics of RCDs)

  • 한운기;송길목;김영석;김동욱;최충석;이복영;박상태
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.61-65
    • /
    • 2005
  • This paper describes the cut off time and the current characteristics of virgin RCDs and deteriorated ones in the seashore. The RCDs(Residual Current Protective Devices) are used for protecting the human body from electrical shock and for preventing facility accidents. According to the Korean standards, the RCDs are installed in panel boards. When RCDs are installed outside, they must be enclosed inside waterproof cases. In the case that RCDs are employed at temporary power sites and electrical facilities on the road they are exposed to the external environment. As a result, the RCDs deteriorated in the seashore for 3 months showed high failure rate, while the virgin RCDs all complied with Korean Standard. Considering that the RCDs are used under exposed condition outside, the reliance of RCDs must be ensured by modifying the related regulations and codes and by developing improved advanced in their performance.

  • PDF

온도상승에 따른 배선용 차단기의 동작특성에 관한 연구 (A Study on the Operating Characteristics of Molded Case Circuit Breakers according to Temperature Rise)

  • 정다운;김재호
    • 한국안전학회지
    • /
    • 제30권5호
    • /
    • pp.8-13
    • /
    • 2015
  • Molded Case Circuit Breakers (MCCBs) are typically used to provide over current protection for electrical safety caused by short circuit faults and overloads in indoor low voltage power systems. The MCCB automatically connects and disconnects loads from the electrical source when the current reaches a value and duration that will cause an excessive. However, the MCCB sometimes is not interrupted due to a malfunction, nuisance tripping, or in a fire. Ensuring electrical safety is very important in a indoor low voltage power system. This paper presents the operating characteristics of MCCBs according to a temperature rise from room temperature to 160 degrees Celsius delivered by a radiant panel heater. The ABS 54c(rated current: 30A) of the hydraulic magnetic trip type was used in the experiments. The signals of temperature, voltage, and current were measured using the high accuracy Signal Conditioning Extensions for Instrumentation (SCXI) measurement system with the LabVIEW program manufactured by National Instruments. The operating characteristics were measured as functions of current amplitude and ramp-up rate. The MCCB tripping time decreased as a result of increasing current amplitude and ramp-up rate under a temperature rise condition, because the temperature and level of the current are directly proportional to the tripping time. Additionally, an instantaneous operation was observed after 8 times of the rated current, and the MCCB began to melt a surface temperature of around 300 degrees Celsius of. The experimental results coincided well with the operating curve.

자동차 에어백의 제어부품 불량에 의한 고장현상 및 후방 추돌에 관련된 에어백 미전개에 대한 사례 연구 (Study of Examples for Air Bag Non-deployment Including Rear Collision and Failure Phenomenon by Damage of Control Parts in Vehicle Air Bag)

  • 이일권;김영규;문학훈
    • 한국가스학회지
    • /
    • 제16권6호
    • /
    • pp.102-106
    • /
    • 2012
  • 이 논문의 목적은 현장에서 발생되는 자동차 에어백 시스템의 고장사례를 모아 분석하고 연구하는 것이다. 첫 번째 사례에서는 에어백 시스템의 클럭 스프링과 에어 백 모듈 사이 배선 핀의 납땜부가 이탈되어, 배선 접촉불량에 의해 핀이 흔들릴 때마다 에어백의 작동불량 현상이 발생되는 것을 확인하였다. 두 번째 사례에서는 에어백 컴퓨터 내부의 단품 소자의 손상으로 인해 에어백 작동불량 현상이 발생된 것을 확인하였다. 세 번째 사례에서는 조수석 시트 벨트 프리텐셔너(pre-tensioner)의 내부 핀과 저항을 연결해 주는 납땜부 이탈로 인해 에어백 경고등이 점등된 것을 확인하였다. 네 번째 사례에서는 승용자동차가 화물자동차의 후면을 추돌하였을 때 때 범퍼는 상대편 차량보다 낮아 아래로 끼어들게 된다. 이 때 사고의 충격은 차량의 프레임부분에 전달되지 않기 때문에 충격센서가 설치된 프레임부분에 충격이 적게 전달되어 에어백이 작동하지 않은 것을 확인하였다.