A Study on the Internal Temperature Reduction of PKG-A Water-jet-room by Substituting Heat Insulation Materials  

Jung, Young In (Naval Sea Systems Center, Defense Agency for Technology and Quality)
Choi, Sang Min (Naval Sea Systems Center, Defense Agency for Technology and Quality)
Publication Information
Abstract
Purpose: The purpose of this study was to resolve the Naval ship's Local Operation Panel(LOP) malfunction problems which caused by overheating in summer season and dispatching to equatorial regions. Methods: Instead of using dual type heat insulation materials(consist with ceramic wool and glass wool), aerogel heat insulation materials were used for decreasing heat emissions from gas-turbine heat waste steam pipes passing water-jet- room. Experiment and Computational analysis of heat flow were conducted to analyze the internal room temperature changes. Results: The results of this study are as follows; The aerogel heat insulation materials suppress heat emission more efficiently than dual type insulation materials. The cold surface temperature of insulation was far more decreased and internal room, LOP surface temperature also showed significant results too. Conclusion: The substituted heat insulation materials appeared remarkable performance in decreasing room temperature that it could be used for suppressing the LOP overheatings and malfunctions.
Keywords
Waste Steam Pipe; Cold Surface Temperature; Local Operation Panel; Heat Insulation; Aerogel;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Catherine A. Morris, and Micheie L. Anderson. 1999. "Silica Sol as a Nanoglue: Flexible Synthesis of Composite Aerogels." SCIENCE 284(4).
2 Defense Acquisition Program Administration. 2012. DDH-993 INSULATION PLAN FOR PIPING.
3 Park, Donggi, and Yoon, Sookhyun. 2013. "A Study on Necessity of Porous Aerogel Materials Apply to Naval Ship." Defense and Technology 418(12):74-91.
4 Republic of Korea Navy Naval Ship Building Department. 2004. PKG-A Pipe Insulation Specification.
5 Republic of Korea Navy. "Criteria for Insulation Felt, Thermal and Sound Absorbing Felt, Fibrous Glass, Flexible." Naval Ship Design/building Criteria, Ship Building(SOO)-KI-6-009(0).
6 Republic of Korea Navy. "Criteria for Thermal Insulation for Machinery, Equipment, and Piping." Naval Ship Design/Building Criteria Ship Building(SOO)-KI-5-202(0).
7 Seo, Dongjin. 2005. "Fabrication & Application of Ultra-Porous Aerogel." Korea Institute of Science and Technology Information.
8 Na Jong cheol. 2012. "The plan of applying advanced novel material aerogels; the core technology of low carbon, green growth." Defense and technology 402(8):60-67.
9 Kang, Myungyoon. 2019. "A study on heat reduction of propulsion system with aerogel material." naval technology 86(1):170-193.