• Title/Summary/Keyword: Malfunction Panel

Search Result 11, Processing Time 0.027 seconds

A Study on OLED display device's line defect test methode (OLED display device의 Line Defect 시험법에 관한 연구)

  • Choi, Young-Tae;Choi, Jai-Rip
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.04a
    • /
    • pp.523-529
    • /
    • 2009
  • The ACF(Anisotropic Conductive Film) is used for bonding Drive IC and OLED display device panel. If ACF bonding process is problem, a malfunction of line defect can occur. Because electric resistance increase between the panel and drive IC after a period of time, drive IC can not supply enough current to the panel. This paper is studied on a method of test for line defect.

  • PDF

The Cause Analysis and Research of Malfunction for Elevator Equipment of the Apartment House (공동주택의 승강기 설비에 대한 오동작 원인 조사 및 고찰)

  • Kim, Gi-Hyun;Bang, Sun-Bae;Kim, Chong-Min;Bae, Suk-Myong;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.65-71
    • /
    • 2006
  • The number of elevator installation increases every year about 15,000. The number of confine-disease of elevator increases every year and then sudden in, sudden stop, error of level indication, stand; those can bring to uneasiness of elevator passenger and malfunction related life accident is increasing. Therefore we researched elevator repair diary of elevator repairing company, APT management office and 119 life rescue for elevator confine-disease during 2004. 1. 1.${\sim}$12. 31. we analyzed the content and the time type and cause of the malfunction and fault for APT elevator. Form the result of 119 life rescue, only power reset is 24[%] and only power failure is 8.2[%] by cause of confine-disease. This paper will be used data of the analysis for mutual relation between Power Quality and malfunction and fault of elevator.

Automatic Detection of Malfunctioning Photovoltaic Modules Using Unmanned Aerial Vehicle Thermal Infrared Images

  • Kim, Dusik;Youn, Junhee;Kim, Changyoon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.6
    • /
    • pp.619-627
    • /
    • 2016
  • Cells of a PV (photovoltaic) module can suffer defects due to various causes resulting in a loss of power output. As a malfunctioning cell has a higher temperature than adjacent normal cells, it can be easily detected with a thermal infrared sensor. A conventional method of PV cell inspection is to use a hand-held infrared sensor for visual inspection. The main disadvantages of this method, when applied to a large-scale PV power plant, are that it is time-consuming and costly. This paper presents an algorithm for automatically detecting defective PV panels using images captured with a thermal imaging camera from an UAV (unmanned aerial vehicle). The proposed algorithm uses statistical analysis of thermal intensity (surface temperature) characteristics of each PV module to verify the mean intensity and standard deviation of each panel as parameters for fault diagnosis. One of the characteristics of thermal infrared imaging is that the larger the distance between sensor and target, the lower the measured temperature of the object. Consequently, a global detection rule using the mean intensity of all panels in the fault detection algorithm is not applicable. Therefore, a local detection rule was applied to automatically detect defective panels using the mean intensity and standard deviation range of each panel by array. The performance of the proposed algorithm was tested on three sample images; this verified a detection accuracy of defective panels of 97% or higher. In addition, as the proposed algorithm can adjust the range of threshold values for judging malfunction at the array level, the local detection rule is considered better suited for highly sensitive fault detection compared to a global detection rule. In this study, we used a panel area extraction method that we previously developed; fault detection accuracy would be improved if panel area extraction from images was more precise. Furthermore, the proposed algorithm contributes to the development of a maintenance and repair system for large-scale PV power plants, in combination with a geo-referencing algorithm for accurate determination of panel locations using sensor-based orientation parameters and photogrammetry from ground control points.

Development of Test Method for Flat Panel Display Life Time Prediction during Atmospheric Particle Exposure (평판디스플레이의 대기중 분진농도에 따른 수명예측 시험방법 개발)

  • Yoo, Dong-Hyun;Lee, Gun-Ho;Choi, Jung-Uk;Ahn, Kang-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.4
    • /
    • pp.45-48
    • /
    • 2013
  • The electronic device, such as flat panel display (FPD), is very important in our life as a means of communication between humans. Liquid crystal display (LCD), which is categorized as a flat panel display, has been used in many display products, especially in TV industry. An LED TV is composed of several electrical components, such as liquid critical module (LCM), analog to digital convertor (AD), power supplier, and inverter board. These modules are very vulnerable to particulate contamination, and causing malfunction or visibility degradation. In this study, we developed a test method for prediction of LCM's lifetime. The test system consists of carbon particle generation flame, dilution system, test chamber, and particle concentration monitoring instrument. Since the carbon particles are the most abundant in the atmosphere and easily absorb light, soot particles are used as a challenging material for this test. The concentration of generated soot particles is set around 4,000,000 #/cc, which is 400 times higher than that of usual atmospheric particles. Through this experiment, we deduced the relationship between the dust concentration and life time of the test specimen.

Air Fluid Analysis between Porous PE-Plate and Glass in Air-Floating FPD Conveyor System (공기부상 FPD 이송장치에서 다공질판과 글래스 사이의 공기유동 해석)

  • Lho, Tae-Jung;Shon, Tae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.4
    • /
    • pp.878-885
    • /
    • 2008
  • The FPDs(Flat Panel Displays) such as LCD(Liquid Crystal Display) and PDP(Plasma Display Panel) and OLED(Organic Light Emitting Diode), recently, have been substituted for CRT(Cathode Ray Tube) displays because they have a convex surface, small volume, light weight and lower electric power consumption. The productivity of FPDs is greatly dependent on the area of thin glass panel with 0.6 - 0.8mm thickness because FPDs are manufactured by cutting a large-scaled thin glass panel with patterns to the required product dimensions. So FPD's industries are trying to increase the area of thin glass panel. For example, the thin glass panel size of the 8th generation is 2,200mm in width, 2,600mm in length and 0.7mm in thickness. The air flows both in the thin glass panel and in the porous PE-plate surface were modeled and analyzed, from which a working condition was estimated. The thin glass panel on the porous PE-plate surface with self-lubricating characteristics was investigated and compared with that on the square duct floating bar surface with many holes of 1mm diameter when the thin glass panel contacts the floating bar surface due to malfunction of electric power supply.

A Study on the Internal Temperature Reduction of PKG-A Water-jet-room by Substituting Heat Insulation Materials (단열재 개선을 통한 PKG-A Water Jet Room 온도저감 연구)

  • Jung, Young In;Choi, Sang Min
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.3
    • /
    • pp.425-435
    • /
    • 2019
  • Purpose: The purpose of this study was to resolve the Naval ship's Local Operation Panel(LOP) malfunction problems which caused by overheating in summer season and dispatching to equatorial regions. Methods: Instead of using dual type heat insulation materials(consist with ceramic wool and glass wool), aerogel heat insulation materials were used for decreasing heat emissions from gas-turbine heat waste steam pipes passing water-jet- room. Experiment and Computational analysis of heat flow were conducted to analyze the internal room temperature changes. Results: The results of this study are as follows; The aerogel heat insulation materials suppress heat emission more efficiently than dual type insulation materials. The cold surface temperature of insulation was far more decreased and internal room, LOP surface temperature also showed significant results too. Conclusion: The substituted heat insulation materials appeared remarkable performance in decreasing room temperature that it could be used for suppressing the LOP overheatings and malfunctions.

Development of Digital controlled SCR type CO2 Welding System for Implementation Pulse Output (펄스 출력 구현이 가능한 디지털 제어의 SCR형 CO2 용접시스템의 개발)

  • Eun, Jong-Mok;Choe, Gyu-Ha
    • Journal of Welding and Joining
    • /
    • v.32 no.1
    • /
    • pp.102-107
    • /
    • 2014
  • SCR(Thyristor) type $CO_2$ welders have widely used for the welding process of heavy industries such as shipbuilding and plant. Since the industrial fields of shipbuilding and plant are usually exposed to severe welding condition with lots of dust, extreme temperature, high humidity and vibration, it is not recommended to use inverter type welder despite its state-of-the-art technology. Many sophisticated functions in the inverter welder may not work due to malfunction of its sensitive components. Hence this study focused on digitalization of SCR $CO_2$ welder by making use of microprocessor for SCR phase control. By this application, fine control of output of the $CO_2$ welding systems is achieved. Also pulse output mode of operation is realized and its verification is carried out with aluminum sample welding. The experimental results showed sound weld bead. The front operation panel provide user with numerical parameter settings and monitors. It will help precise weld process monitoring and control with digital value.

A Study on the Cutoff time and the Malfunction Current Characteristics of RCDs (누전차단기 동작시간 및 부동작 전류 특성)

  • Han, Woon-Ki;Shong, Gil-Mok;Kim, Yong-Seok;Kim, Dong-Wook;Choi, Chung-Seog;Lee, Bok-Yong;Park, Sang-Tae
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.61-65
    • /
    • 2005
  • This paper describes the cut off time and the current characteristics of virgin RCDs and deteriorated ones in the seashore. The RCDs(Residual Current Protective Devices) are used for protecting the human body from electrical shock and for preventing facility accidents. According to the Korean standards, the RCDs are installed in panel boards. When RCDs are installed outside, they must be enclosed inside waterproof cases. In the case that RCDs are employed at temporary power sites and electrical facilities on the road they are exposed to the external environment. As a result, the RCDs deteriorated in the seashore for 3 months showed high failure rate, while the virgin RCDs all complied with Korean Standard. Considering that the RCDs are used under exposed condition outside, the reliance of RCDs must be ensured by modifying the related regulations and codes and by developing improved advanced in their performance.

  • PDF

A Study on the Operating Characteristics of Molded Case Circuit Breakers according to Temperature Rise (온도상승에 따른 배선용 차단기의 동작특성에 관한 연구)

  • Jung, Da-Woon;Kim, Jae-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.8-13
    • /
    • 2015
  • Molded Case Circuit Breakers (MCCBs) are typically used to provide over current protection for electrical safety caused by short circuit faults and overloads in indoor low voltage power systems. The MCCB automatically connects and disconnects loads from the electrical source when the current reaches a value and duration that will cause an excessive. However, the MCCB sometimes is not interrupted due to a malfunction, nuisance tripping, or in a fire. Ensuring electrical safety is very important in a indoor low voltage power system. This paper presents the operating characteristics of MCCBs according to a temperature rise from room temperature to 160 degrees Celsius delivered by a radiant panel heater. The ABS 54c(rated current: 30A) of the hydraulic magnetic trip type was used in the experiments. The signals of temperature, voltage, and current were measured using the high accuracy Signal Conditioning Extensions for Instrumentation (SCXI) measurement system with the LabVIEW program manufactured by National Instruments. The operating characteristics were measured as functions of current amplitude and ramp-up rate. The MCCB tripping time decreased as a result of increasing current amplitude and ramp-up rate under a temperature rise condition, because the temperature and level of the current are directly proportional to the tripping time. Additionally, an instantaneous operation was observed after 8 times of the rated current, and the MCCB began to melt a surface temperature of around 300 degrees Celsius of. The experimental results coincided well with the operating curve.

Study of Examples for Air Bag Non-deployment Including Rear Collision and Failure Phenomenon by Damage of Control Parts in Vehicle Air Bag (자동차 에어백의 제어부품 불량에 의한 고장현상 및 후방 추돌에 관련된 에어백 미전개에 대한 사례 연구)

  • Lee, Il Kwon;Kim, Young Gyu;Moon, Hak Hook
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.102-106
    • /
    • 2012
  • The purpose of this paper is to study the failure cases in relation to system of Air Bag in vehicle happened in the field. In the first example, it was separated the soldering parts connected the wire pin between air bag module and clock spring of air bag. Whenever the pin shake by the car's vibration, the driver verified the malfunction phenomenon appeared air bag warning lamp on instrument panel in front of driver's seat. in car inside room. The second example, it verified the warning lamp lighting phenomenon of air bag by produced the circuit plate non-contacting of single an element in air bag electronic control unit. The third example, it verified the light of air bag warning indicator lamp by separated with soldering parts connecting inner pin and resistance terminal of seat belt pretensioner using passenger seat. The fourth example, when the passenger car crash a back of truck, the former bumper get jammed under the latter as the roof height of car low less than that. Therefore, the impact of Car's collision verified that don't transfer with body frame of vehicle because of no attachment impact sensor in it.