• Title/Summary/Keyword: Malfunction

Search Result 918, Processing Time 0.036 seconds

A Study of the Reliability of Distribution System for Malfunction of Protective Relay (보호계전기의 오동작에 의한 배전계통 신뢰도에 대한 연구)

  • Shin, Jung-Jin;Lee, Hee-Tae;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.205_206
    • /
    • 2009
  • Protection system is important part in distribution system. Protection system in power systems can fail either by not responding when they should(failure to operate) or by operating when they should not(false tripping). Customers has dissatisfied that due to the failure of protection system. The reliability of distribution system also has influenced. However, the failure of protection system can reduced by the maintenance. This paper has focused on malfunction of protection system. The approach is based on Markov models.

  • PDF

The Development of No-Mercury Type Card Relay for Improving the Reliability of Electrical Facilities (설비신뢰성 향상을 위한 무수은형 카드릴레이 개발 및 운영)

  • Ahn, J.K.;Chang, J.W.;Kim, J.K.;Yang, J.W.;Lee, S.I.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.641-644
    • /
    • 2007
  • The electro-mechanical mercury relay is used as an auxiliary relay of power facility because it is superior to operating time and no-bounce. So the KEPCO had used the mercury relay for operating HVDC(High Voltage Direct Current) system. But it has many problems with facility operation by occurrence of mercury evaporation, held contact point and malfunction according to long term use, furthermore it is forbidden to produce for fear of environmental pollution in 2002. This paper presents the no-mercury relay development, comparison test and application.

Multiple Case-based Reasoning Systems using Clustering Technique (클러스터링 기법에 의한 다중 사례기반 추론 시스템)

  • 이재식
    • Journal of Intelligence and Information Systems
    • /
    • v.6 no.1
    • /
    • pp.97-112
    • /
    • 2000
  • The basic idea of case-based reasoning is to solve a new problem using the previous problem-solving experiences. In this research we develop a case-based reasoning system for equipment malfunction diagnosis. We first divide the case base into clusters using the case-based clustering technique. Then we develop an appropriate case-based diagnostic system for each cluster. In other words for individual cluster a different case-based diagnostic system which uses different weights for attributes is developed. As a result multiple case-based reasoning system are operating to solve a diagnostic problem. In comparison to the performance of the single case-based reasoning system our system reduces the computation time by 50% and increases the accuracy by 5% point.

  • PDF

The Damage of Microcontroller Devices due to Coupling Effects by High Power Electromagnetic Wave (고출력 전자기파의 커플링 효과에 의한 마이크로컨트롤러 소자의 피해)

  • Hong, Joo-Il;Hwang, Sun-Mook;Huh, Chang-Su
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.148-155
    • /
    • 2008
  • We investigated the damage effects of microcontroller devices under high power electromagnetic(HPEM) wave. HPEM wave was radiated from the open-ended standard rectangular waveguide(WR-340) to free space. The influence of different reset-, clock-, data-, and power supply-line lengths has been tested. The susceptibility of the tested microcontroller devices was in general much influenced by clock-, reset-, and power supply-line length, little influenced by data-line length. Further the line length was increased, the malfunction threshold was decreased as expected, because more energy couples to the devices. The surfaces of the destroyed microcontroller devices were removed and the chip conditions were investigated with microscope. The microscopic analysis of the damaged devices showed component and bondwire destructions such as breakthroughs and melting due to thermal effects.

A Study on Development of Maintenance Skill Training Simulator for Railway Vehicle

  • Jung, NoGeon;Kim, BoSung;Lee, JaeBong;Lee, SangMoon;Koo, KyungWan;Kim, JaeMoon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.113-116
    • /
    • 2015
  • Generally, in the railway vehicle the driving force of gravity happens by the high-speed running and the repetitive impulse cause the degradation and the malfunction phenomenon shows differently because the durability of each component changes according to the internal and external causes. The maintenance of propulsion control device which is played the very important role as to the stable service of the railway vehicle is greatly important among them. Therefore maintenance training propulsion control device simulator is needed to maximize learning through repetition and improve the maintenance practical skills training. This paper designed the railway vehicle running device with a miniature for the railway vehicle maintenance training and developed a propulsion control device simulator equipped the imitation steering wheel.

Development of a Digital Motor Control Center (디지틀형 MOTOR CONTROL CENTER 개발)

  • Byun, Young-Bok;Joe, Kee-Yeon;Kim, Yo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.563-566
    • /
    • 1989
  • Drive malfunction take many forms and every possible one must be protected against. Until recently a separate analog device was needed for each type of malfunction. In this approach to simplified, more reliable motor-circuit protection and control, a microprocessor's digital controller for motor control center simultaneously examine most of the possible sources of circuit trouble and has more efficent functions (sequence control,display) than the conventional motor control center. The result of standard surge tests provided a realistic evaluation of the surge withstand capability of equipment.

  • PDF

A study on the data fault detection system for diesel engine using neural network. (뉴럴네트웍을 이용한 디젤기관의 데이터 이상감지 시스템에 관한 연구)

  • 천행춘;김영일;김경엽;안순영;오현경;유영호
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.245-250
    • /
    • 2002
  • The operational data of diesel generator engine is two kind of discrete signal and analog signal. We can find the fault information from analog data measured for every sampling time if it is invested the changing rate or direction of data. This paper propose the Malfunction Diagnosis Engine(MDE) using the commercial data mining tool and show the data Process and fault finding method with the data collected from generator engine of the ship.

  • PDF

Study on the Ground Fault Protection in 6.6KV Ungrounded Power System SGR Malfunction or Non-Tripping (선택지락보호계전기 오.부동작에 관한 연구)

  • Kim, Byung-Tae;Lee, Dal-Woo;Jeon, Myung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.296-301
    • /
    • 2008
  • This paper presents a study on the ground fault protection in 6.6KV ungrounded power system relay(SGR) malfunction or non-tripping. Ground test had made on 6.6KV HV(high voltage) system, Some of domestic and oversea's SGR products are different from their own specific characteristics. This study on the ground protection relay 6.6KV power supply system is focused to protect human.

Acute Shunt Malfunction Caused by Percutaneous Endoscopic Gastrostomy without Shunt Infection

  • Choi, Jingyu;Ki, Seung Seog;Park, Seoungwoo
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.4
    • /
    • pp.361-363
    • /
    • 2014
  • Percutaneous endoscopic gastrostomy tube placement is often performed in patients with a ventriculoperitoneal shunt and it has been accepted as a safe procedure. The authors report a case of a 50-year-old male who developed acute exacerbation of the hydrocephalus immediately after the percutaneous endoscopic gastrostomy tube placement without any signs of shunt infection, which has not been reported until now. After revision of the intraperitoneal shunt catheter, the sizes of the intracranial ventricles were normalized.

Lightning Surge Response Characteristics of Non-tripping Type Earth Leakage Breakers for Impulse (충격파 부동작형 누전차단기의 뇌써지 응답 특성)

  • Lee, J.B.;Myung, S.H.;Cho, Y.G.;Chang, S.H.;Kim, J.S.;Kil, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1688-1690
    • /
    • 2002
  • The unpredictable threat of lightning surge is ever increasing in today's low-voltage power supplies. Thus Surge protection devices for AC mains are more widely used. The false-tripping of the earth leakage breaker (ELB) can be caused by the installation of surge protection devices with MOV. In order to examine the cause of malfunction, the malfunction characteristics of ELBs applied by lightning surge were investigated experimentally. As a result, all of them brought about malfunctions under 7 kV of the impulse voltage. The suitable position of MOV and use of zener diode were suggested to eliminate the problems.

  • PDF