• Title/Summary/Keyword: Major foramen

Search Result 22, Processing Time 0.021 seconds

An evaluation of the accuracy of Root ZX according to the conditions of major apical foramen (주근단공의 조건에 따른 Root ZX의 정확성 평가)

  • Park, Shin-Young;Lee, Dong-Kyun;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.2
    • /
    • pp.68-73
    • /
    • 2012
  • Objectives: The purpose of this study was to assess the accuracy of Root ZX (J. Morita Corp.) according to the location of major foramen and open apex. Materials and Methods: 81 mandibular premolars with mature apices were selected. After access preparation, 27 teeth were instrumented to simulate open apices. 54 teeth were classified according to location of major foramen under surgical microscope (${\times}16$). The file was fixed at the location of apical constriction by Root ZX using glass ionomer cement .The apical 4 mm of the apex was exposed and photo was taken and the distance from file tip to the major foramen was measured by calibrating metal ruler on graph paper. The results were statistically analyzed using ANOVA and Scheffe test at p < 0.05 level. Results: Mean distance from file tip to major foramen was 0.308 mm in Tip foramen group (I), 0.519 mm in Lateral foramen group (II) and 0.932 mm in open apex group (III). Root ZX located apical constriction accurately within ${\pm}0.5mm$ in group I of 85.71%, in group II of 59.09%, and in group III of 33.33%. There was a statistically significant difference between group I and III (p < 0.05). Conclusion: Root ZX located apical constriction accurately regardless of location of major foramen. However, Root ZX couldn't find it in open apex. Clinicians have to use a combination of methods to determine an appropriate working length at open apex. It may be more successful than relying on just electronic apex locator.

Occipital Dysplasia in Dogs (개의 후두골 이형성)

  • 윤정회;이회천;안용주;최호정;윤화영;권오경;남치주;성재기
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.357-360
    • /
    • 1997
  • Occipital dysplasias in five dogs showing various neurologic signs of unknown origin were diagnosed with clinical examination and skull radiographic assessment at this university teaching hospital. The severities of occipital dysplasia were Grade III in four dogs and Grade II in one dog. Major clinical signs were ataxia and convulsion. In skull radiographs, there were dorsal extents of the foramen magnum reached nuchal crest in all cases. Also, hydrocephalus or vertebral malformation was complicated in three cases.

  • PDF

A Fatal Complication Associated with Combined Posterior Petrous and Suboccipital Approach to a Giant Jugular Foramen Schwannoma - A Case Report - (하후두부 접근법과 후경추체 접근법에 의한 거대 경정맥공 신경초종의 제거술과 동반된 합병증 - 증례보고 -)

  • Koh, Sung-Bum;Koh, Young-Cho;Yoo, Heon;Park, Si-Young;Park, Hyo-IL
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.9
    • /
    • pp.1144-1149
    • /
    • 2001
  • Schwannomas of the jugular foramen, originating from the glossopharyngeal nerve, vagus and accessory nerve represent approximately 0.17-0.72% of all intracranial tumor, and consists of 1.4-2.9% of all intracranial schwannomas. The clinical presentation of these tumors varies significantly according to originated nerve and it's growth pattern. Magnetic resonance(MR) image and temporal bone computed tomography(CT) scan have a major role for diagnosis of such tumor. The treatment of choice is total resection whenever possible. Generally, suboccipital approach is sufficient for the removal of the tumor, but in case with large size, combination of resection of petrous part of temporal bone with or without transection of sigmoid sinus is may be necessory. We have recently experienced one case of giant jugular foramen schwannoma and postoperative fatal complication in a 34-year-old male who was treated with combined posterior petrous and suboccipital approach with transection of sigmoid sinus

  • PDF

The Study on Static Alignment Classification based on the Full Spine AP X-ray of Adults aged 30-39 (30대 성인의 골반, 척추 및 견갑대 정렬의 패턴 분석 - Full Spine AP X-ray 분석에 따른 -)

  • Park, Ji-Hyun;Hong, Seo-Young
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.20 no.2
    • /
    • pp.89-99
    • /
    • 2010
  • Objectives : This study was designed to analyze the pattern of asymmetrical alignment. Methods : This study was carried out with the data from comprehensive medical testing. 91 subjects aged 30-39 were evaluated by full spine AP X-ray. For pelvis, innominate measurement(IM), off centering measurement(OCM), ilium shadow measurement(ISM), major axis of obturator foramen(MaF), minor axis of obturator foramen(MiF) were analyzed. Spinal curvature and height of shoulder girdle were analyzed. Results : 1. In pelvis, It. posterior-inferior and it. inflare combination pattern was 38 cases(42.8%). 2. In spinal curvature, "reverse S" curve was 45 cases(49.4%) and "reverse C" curve was 30 cases(33%). 3. In shoulder girdle, It. superior pattern was 42 cases(46.1 %) and It. superior pattern was 39 cases(42.9%). 4. In whole body analysis, It. posterior-inferior and It. inflare pelvis, "reverse S" spinal curvature and It. superior shoulder girdle combination patten was 11 cases(12.1 %). This pattern is similar to Kendall's right handedness pattern and Zink's common compensatory pattern. Conclusions : Results from this investigation showed asymmetrical alignment in 30-39 years-old adults. This results are expected to contribute to classifying the alignment pattern in clinic and systemic treatment.

In vivo assessment of accuracy of Propex II, Root ZX II, and radiographic measurements for location of the major foramen

  • Tampelini, Fernanda Garcia;Coelho, Marcelo Santos;de Azevedo Rios, Marcos;Fontana, Carlos Eduardo;Rocha, Daniel Guimaraes Pedro;Pinheiro, Sergio Luiz;da Silveira Bueno, Carlos Eduardo
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.3
    • /
    • pp.200-205
    • /
    • 2017
  • Objectives: The aim of this in vivo study was to assess the accuracy of 2 third-generation electronic apex locators (EALs), Propex II (Dentsply Maillefer) and Root ZX II (J. Morita), and radiographic technique for locating the major foramen (MF). Materials and Methods: Thirty-two premolars with single canals that required extraction were included. Following anesthesia, access, and initial canal preparation with size 10 and 15 K-flex files and SX and S1 rotary ProTaper files, the canals were irrigated with 2.5% sodium hypochlorite. The length of the root canal was verified 3 times for each tooth using the 2 apex locators and once using the radiographic technique. Teeth were extracted and the actual WL was determined using size 15 K-files under a ${\times}25$ magnification. The Biostat 4.0 program (AnalystSoft Inc.) was used for comparing the direct measurements with those obtained using radiographic technique and the apex locators. Pearson's correlation analysis and analysis of variance (ANOVA) were used for statistical analyses. Results: The measurements obtained using the visual method exhibited the strongest correlation with Root ZX II (r = 0.94), followed by Propex II (r = 0.90) and Ingle's technique (r = 0.81; p < 0.001). Descriptive statistics using ANOVA (Tukey's post hoc test) revealed significant differences between the radiographic measurements and both EALs measurements (p < 0.05). Conclusions: Both EALs presented similar accuracy that was higher than that of the radiographic measurements obtained with Ingle's technique. Our results suggest that the use of these EALs for MF location is more accurate than the use of radiographic measurements.

IN VITRO EVALUATION OF THE CONSISTENCY OF TWO ELECTRONIC APEX LOCATORS (2종 전자근관장측정기의 일관성에 관한 in vitro 연구)

  • Hwang, Gyu-Young;Roh, Byoung-Duck;Kim, Eui-Sung;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.20-27
    • /
    • 2008
  • The purpose of this study was to evaluate the consistency of two electronic apex locators in vitro model. Materials consisted of fifty two extracted premolars and two electronic apex locators; Root ZX (J. Morita, Osaka, Japan) and E-Magic Finder Deluxe (S-Denti. Cheonan, Korea). After access preparation, the teeth were embedded in a saline-mixed alginate model. Canal lengths of each tooth were measured at "0.5" and "Apex" mark of the apex locators, respectively so that each tooth had two measurements from 0.5 and Apex points. The file was fixed at final measurement using a glass ionomer cement. The apical 4 mm from the apex was exposed to measure the distance from the file tip to the major apical foramen of each tooth. Average distances and standard deviations were used to evaluate the consistency. Results showed that all measurements of both Root ZX and E-Magic Finder located the major foramen the range of ${\pm}0.5\;mm$ level. Both apex locators showed better consistency at Apex mark than at 0.5 mark. The average distance of file tip-major foramen was - 0.18 mm at 0.5 mark and - 0.07 mm at Apex mark in Root ZX, - 0.25 mm at 0.5 mark and - 0.02 mm at Apex mark in E-Magic Finder. Standard deviation was 0.21 at 0.5 mark and 0.12 at Apex mark in Root ZX, 0.12 at 0.5 mark and 0.09 at Apex mark in E-Magic Finder.

In vivo evaluation of accuracy and consistency of two electronic apex locators (2종 전자근관장측정기의 정확도 및 일관성에 관한 in vivo 연구)

  • Pi, Chien-Yun;Kim, Eui-Seong;Jung, Il-Young;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.453-460
    • /
    • 2010
  • Objectives: To evaluate the accuracy and consistency of two different apex locators at both the Apex and 0.5 marks. Materials and Methods: Twenty-six root canals was scheduled for extraction for periodontal or prosthodontic reasons. Thirteen canals were measured using Root ZX and the rest by i-ROOT. The root canal length was measured both the at 0.5 mark and the Apex mark. The file was then fixed to the toot, and the distance from the file tip to the major foramen of each canal was measured after removing the root dentin under the microscope so that the major foramen and the file tip were seen. Results: 1. When the Apex mark was used, 100% of both the Root ZX and i-ROOT groups were within 0.5 mm of the major foramen. 2. When 0.5 mark was used, 100% of the Root ZX group and 77% of the i-ROOT group were within 0.5 mm of the major foramen. 3. In terms of standard deviation and quartile value, the Apex mark was more consistent than 0.5 mark in the Root ZX group, and 0.5 mark was more consistent in the i-ROOT group, but there was no statistically significant difference when compared with t-test. 4. The root canal length difference between the Apex mark and 0.5 mark was 0.22 mm and 0.46 mm in the Root ZX and i-ROOT groups, respectively. Conclusions: In this study, the Apex mark was the more consistent mark. Therefore, it is recommended to subtract 0.5 mm, which is the average length between the apex and apical constriction, from the root canal length at the Apex mark to obtain the working length clinically.

A case report of "minor" trauma leading to a major disability: whiplash-associated dysphagia, dysphonia, and dysgeusia

  • Schattner, Ami;Glick, Yair
    • Journal of Trauma and Injury
    • /
    • v.35 no.2
    • /
    • pp.115-117
    • /
    • 2022
  • "Whiplash"-type injuries are commonly encountered and often cause neck pain, neck stiffness, and headaches. However, these injuries can have rare and poorly recognized complications, such as the development of a prevertebral hematoma leading to acute respiratory failure in the emergency department, followed by severe, life-threatening dysphagia and recurrent aspirations. In the patient described herein, a whiplash injury was accompanied by vocal cord paralysis and dysphonia (vagus nerve), dysgeusia (glossopharyngeal nerve, vagus nerve), and upper esophageal spasm (cricopharyngeal muscle, vagus nerve). It is unlikely that this was a complication of cervical fusion surgery. Instead, a combined stretch-induced lower cranial nerve injury, possibly on the exit of these nerves through the jugular foramen, seems to be a likely, but underappreciated mechanism occurring in rare instances of whiplash injuries.

IN VITRO EVALUATION OF ACCURACY AND CONSISTENCY OF FOUR DIFFERENT ELECTRONIC APEX LOCATORS (4종 전자근관장측정기의 정확성과 일관성에 관한 in vitro 연구)

  • Cho, Jae-Hyun;Kum, Kee-Yeon;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.390-397
    • /
    • 2006
  • The purpose of this study was to evaluate the accuracy and the consistency of four different electronic apex locators in an in vitro model. Fourty extracted premolars were used for the study. Four electronic apex locators (EAL) were Root ZX, Smarpex, Elements Diagnostic Unit (EDU), and E-Magic Finder Deluxe (EMF). After access preparation, the teeth were embedded in an alginate model and the length measurements were carried out at '0.5' and 'Apex' mark using four EALs. The file was cemented at the location of the manufacturers' instruction (Root ZX, EDU, EMF: 0.5 mark, SmarPex: Apex mark). The apical 4mm of the apex was exposed and the distance from the file tip to the major foramen was measured by Image ProPlus (${\times}100$). The distance from the file tip to the major foramen was calculated at 0.5 and Apex mark and the consistency of 0.5 and Apex mark was compared by SD and Quartile of Box plots. In this study, Root ZX and EMF located the apical constriction accurately within ${\pm}0.5 mm$ in 100%, whereas SmarPex and EDU located in 90% and in 70% respectively. For Root ZX and EMF, there was no significant difference between the consistency of 0.5 and Apex mark. However, for the EDU and SmarPex, Apex mark was more consistent than 0.5 mark. From the evaluation of the consistency in this study, for Root ZX and EMF, both 0.5 and Apex mark can be used as a standard mark. And for EDU and SmarPex, the Apex mark can be recommended to be used as a standard mark.

A Review of the Total Correction of Tetralogy of Fallot (Fallot 사징증에 대한 근치수술)

  • 최세영
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.258-264
    • /
    • 1985
  • The experience with operative treatment for total correction of Fallot at the department of Thoracic and Cardiovascular Surgery, Keimyung University Dong San Medical Center from July 1980 to July 1984 was reviewed. There were 37 males and 12 females and their ages ranged from 3 years to 30 years, with the average age of 12.2 years. Sixty nine point four percent of patients were younger than 15 years of age. The most frequent type of right ventricular outflow stenosis was the combined type [pulmonary valvular and infundibular stenosis] containing 41 patients [83.7%] and there were 9 deaths in this group. The major associated lesions included Patent foramen ovale in 20 patients [40.8%], Atrial septal defect in 7 patients [14.3%], Left superior vena cava in 4 patients [8.2%], Right sided aortic arch in 2 patients [4.1%] and Patent ductus arteriosus in 11 patient [2.0%]. The pulmonary valvotomy was performed in 41 patients and patch graft reconstruction of the right ventricular outflow tract was performed in 23 patients. In 11 patients the monocusp patches were used. Thirty-five patients [71.4%] had the right bundle branch block postoperatively. There were 11 postoperative deaths with hospital mortality rate of 22.4% and the leading causes of death were low output syndrome, bleeding, and cerebral embolism.

  • PDF