References
- Ding J, Gutmann JL, Fan B, Lu Y, Chen H. Investigation of apex locators and related morphological factors. J Endod 2010;36:1399-1403.
- Riccuci D, Langeland K. Apical limit of root canal instrumentation and obturation, part 2. a histological study. Int Endod J 1998;31: 394-409.
- Suzuki K. Experimental study on iontophoresis. J Jpn Stomatol 1942;16:411-417.
- Sunada I. New method for measuring the length of the root canal. J Dent Res 1962;41:375-387.
- Kobayashi C, Suda H. New electronic canal measuring device based on the ratio method. J Endod 1994;20: 111-114.
- Kobayashi C. Electronic canal length measurement. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1995; 79:226-231.
- Green D. Stereomicroscopic study of 700 root apices of maxillary and mandibular posterior teeth. Oral Surg Oral Med Oral Pathol 1960;13:728-733.
- Dummer PM, McGinn JH, Rees DG. The position and topography of the apical canal constriction and apical foramen. Int Endod J 1984; 17:192-198.
- Kuttler Y. Microscopic investigation of root apexes. J Am Dent Assoc 1955;50:544-552.
- Torabinejad M, Walton RE. Endodontics: principles and practice. 4th ed. Missouri: Saunders Elsevier; 2009. p29-34.
- Herrera M, Abalos C, Planas AJ, Llamas R. Influence of apical constriction diameter on Root ZX apex locator precision. J Endod 2007;33:995-998.
- Stein TJ, Corcoran JF, Zillich RM. Influence of the major and minor foramen diameters on apical electronic probe measurements. J Endod 1990;16:520-522.
- Fouad AF, Rivera EM, Krell KV. Accuracy of the Endex with variations in canal irrigants and foramen size. J Endod 1993;19:63-67.
- Huang L. An experimental study of the principle of electronic root canal measurement. J Endod 1987;13:60-64.
- Hachmeister DR, Schindler WG, Walker WA 3rd, Thomas DD. The sealing ability and retention characteristics of mineral trioxide aggregate in a model of apexification. J Endod 2002;28:386-390.
- Cho JH, Kum KY, Lee SJ. In vitro evaluation of accuracy and consistency of four different electronic apex locators. J Korean Acad Cons Dent 2006;31:390-397.
- Ponce EH, Vilar Fernandez JA. The cemento-dentinocanal junction, the apical foramen, and the apical constriction: evaluation by optical microscopy. J Endod 2003;29:214-219.
- Sjogren U, Hagglund B, Sundqvist G, Wing K. Factors affecting the long-term results of endodontic treatment. J Endod 1990;16:498-504.
- Pagavino G, Pace R, Baccetti T. A SEM study of in vivo accuracy of the Root ZX electronic apex locator. J Endod 1998;24:438-441.
- Goldberg F, De Silvio AC, Manfre S, Nastri N. In vitro measurement accuracy of an electronic apex locator in teeth with simulated apical root resorption. J Endod 2002;28:461-463.
- Nguyen HQ, Kaufman AY, Komorowski RC, Friedman S. Electronic length measurement using small and large files in enlarged canals. Int Endod J 1996;29:359-364.
- Kim BH, Lee YK, Kim YS. A study on the accuracy of the ROOT-ZX in the canal with mechanically formed constriction. J Korean Acad Cons Dent 1999;24:628-632.
- Czerw RJ, Fulkerson MS, Donnelly JC. An in vitro test of a simplified model to demonstrate the operation of electronic root canal measuring devices. J Endod 1994;20:605-606.
- Cho YL, Son WH, Hwang HK. An accuracy of the several electronic apex locators on the mesial root canal of the mandibular molar. J Korean Acad Cons Dent 2005;30:477-485.
- Lee SJ, Nam KC, Kim YJ, Kim DW. Clinical accuracy of a new apex locator with an automatic compensation circuit. J Endod 2002;28;706-709.
- Ounsi HF, Naaman A. In vitro evaluation of the reliability of the Root ZX electronic apex locator. Int Endod J 1999;32:120-123.
- Mayeda DL, Simon JH, Aimar DF, Finley K. In vivo measurement accuracy in vital and necrotic canals with the Endex apex locator. J Endod 1993;19:545-548.
- Herrera M, Abalos C, Planas AJ, Llamas R. Influence of apical constriction diameter on Root ZX apex locator precision. J Endod 2007;33:995-998.
- Shabahang S, Goon WW, Gluskin AH. An in vivo evaluation of Root ZX electronic apex locator. J Endod 1996;22:616-618.
- Tselnik M, Baumgartner JC, Marshall JG. An evaluation of root ZX and elements diagnostic apex locators. J Endod 2005;31:507-509.
- Plotino G, Grande NM, Brigante L, Lesti B, Somma F. Ex vivo accuracy of three electronic apex locators: Root ZX, Elements Diagnostic Unit and Apex Locator and ProPex. Int Endod J 2006;39:408-414.
- Meredith N, Gulabivala K. Electrical impedance measurements of root canal length. Endod Dent Traumatol 1997;13:126-131.
- Nekoofar MH, Ghandi MM, Hayes SJ, Dummer PM. The fundamental operating principles of electronic root canal length measurement devices. Int Endod J 2006;39:595-609.
- Berman LH, Fleischman SB. Evaluation of the accuracy of the Neosono-D electronic apex locator. J Endod 1984;10:164-167.
- Saito T, Yamashita Y. Electronic determination of root canal length by newly developed measuring device. Influences of the diameter of apical foramen, the size of K-file and the root canal irrigants. Dent Jpn (Tokyo) 1990;27:65-72.
- Huang L. An experimental study of the principle of electronic root canal measurement. J Endod 1987;13: 60-64.
- ElAyouti A, Weiger R, Lost C. Frequency of overinstrumentation with an acceptable radiographic working length. J Endod 2001;27:49-52.
Cited by
- Evaluating Accuracy according to the Evaluator and Equipment Using Electronic Apex Locators vol.13, pp.2, 2012, https://doi.org/10.5856/jkds.2020.13.2.52