• Title/Summary/Keyword: Maintenance status

Search Result 921, Processing Time 0.029 seconds

Study on the Correlation between Dental Implant Patients' Oral Hygiene Behaviors and Satisfaction (치과 임플란트 환자의 구강위생 관리행태와 만족도의 관련성 조사)

  • Moon, Seon-Jeong;Kim, Eun-Hee;Park, Hong-Ryurn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.576-584
    • /
    • 2015
  • This research studiedthe correlation between dental implant patients' oral hygiene behaviors and satisfaction. By doing so, this study seeks to provide the basic data for the development of diagonal and educational programs to improve implant prosthesis maintenance and satisfaction. The data was collected from January 7 to June 30, 2014, analyzed by SAS (ver 9.2) and for this research, 6 dental hospitals and clinics in Daegu, Busan and Jinju, South Korea were examined for their implant patients receiving treatment. As a result, a total of 266 sets of data were investigated herein to reach the following findings: 1. The survey on status of dental implant prosthesis use and maintenance knowledge found 1.41 on average out of the total score of 3. 2. In the survey on implant prosthesis maintenance after putting in, the dental scaling cycle was found to be 'none' (63.2%). 3. In the survey on implant use status and satisfaction with their implant prosthesis, the masticatory function (p=0.001) were found to be significantly higher in the group using such oral-hygiene goods. 4. In the correlation analysis among one's knowledge on dental implant maintenance, discomfort and satisfaction, it was found that the more they used oral-hygiene supplementary goods (${\beta}=0.095$), the more they had knowledge on implant maintenance (${\beta}=0.069$) and the more they experienced oral health education (${\beta}=0.032$), the higher their satisfaction levels were. It is deemed that, for enhanced satisfaction of dental implant patients, their maintenance behaviors need to be further improved through oral health educational programs.

Survey of Current Status of the Graveyard Lawn Maintenance in Korea (우리나라 묘지의 잔디 관리 실태 조사 연구)

  • Chang, Seog-Won;Lee, Jeong-Ho;Kwon, Byeong-Seok;Hong, Jeum Kyu;Park, Sho-Jun;Byun, Jae-Bok;Jee, Jae-Uk
    • Weed & Turfgrass Science
    • /
    • v.6 no.2
    • /
    • pp.130-135
    • /
    • 2017
  • In the current study, we surveyed the status of graveyard lawn maintenance in Korea. The lawn maintenance information was obtained from the vicarious companies registered on the internet portal site and the Forestry Federation of Korea, and the questionnaire investigation from Primary Agricultural Cooperatives (Nonghyup). In all provinces surveyed, individual graves were maintained on a $66m^2$ (20 Pyeong) basis. The vicarious maintenance of graveyard lawn was carried out 1~5 times a year, and the maintenance cost increased as the number of times increased. Mowing the grass around a grave (Beolcho) was mainly done before the Korean Thanksgiving Day (Chuseok). The number of Beolcho was steadily increased from 2013 to 2015, and the price was getting higher and higher. Gyeonggi province had the highest cost, and Jeolla had the lowest cost. Regardless of the year, the number of orders received were higher in Gyeongnam > Gyeongbuk > Jeonnam province in order. Most of the reason for requested Beolcho was because the client lives in the area far from the graveyard. The direction of the cemetery was very varied. According to the survey, the all grass were zoysiagrass (Zoysia japonica), and grass coverage rate of the graves was 35.4~71.9%. Through questionnaire investigation, the reason why the density of grass was lowered was because the periodic management of weeds and fallen leaves was insufficient. Further research on the maintenance of graveyard in the future will be necessary.

A study on the present operation status and the efficient maintenance program of the air-conditioners in each train model (철도차량용 냉방기의 차종별 운용현황고찰과 효율적인 유지보수방안 연구)

  • Hwang, Myeong-Yeon;Sin, Myeong-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.426-430
    • /
    • 2008
  • Though the air-conditioners in each train model have almost identical function, there is incompatibility between them because of their different electric capacity and parts, even spares manufactures are different in the manufactured year. It cause over cost in the maintenance and repair of the each air-conditioner. In this paper, all the air-conditioners in each train model have been classified by their capacity and features so that grasp the operation status and the repair process of the air-conditioners, and draft systematically cost-effective solutions. By finding a way to deal with the emergency repair and extending the air-conditioner life though improvement of checking up progress, increase of passenger revenue can be reached considerably.

  • PDF

Development of Standard Guideline for Water-leakage and Maintenance by parts of the Underground Structures in Multi-Family Housing - A Case Analysis of Water Leak Diagnosis - (공동주택 지하구조물의 부위별 표준 누수 진단 유지관리 지침 개발 - 누수 진단 사례 분석 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Song, Je Young;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.142-143
    • /
    • 2017
  • An analysis of the current water leak status of understand structure (underground parking lots, staircases, plumbing systems, water reservoirs, etc.) of multi-family housing in South Korea shows that water leaks are found from cracks in all areas of the underground structure caused by the degradation environment (water pressure by underground water, humidity, temperature, earth pressure, soil behaviour and vibration, etc.), which result in various problems, including mold, malodour, debonding of finishing materials, exfoliation, breakout, water leaks in electrical boxes, efflorescence, sedimentation of calcium hydroxide, decoloration, rusting, damages and pollution among others. Therefore, this study aims to analyse the current status of water leaks in underground structure and use the results as the basic data for developing a standard guideline for water leaks and maintenance by parts of the underground structure of multi-family housing.

  • PDF

Proposal on the Standard Water Leakage Diagnosis Manual of Leakage Type in Underground Structures Housing -Focused on Maintenance Plan - (공동주택 지하구조물 표준 누수 진단 매뉴얼 제안 - 유지관리 계획을 중심으로 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Song, Je Young;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.221-222
    • /
    • 2017
  • An analysis of the current water leak status of understand structure (underground parking lots, staircases, plumbing systems, water reservoirs, etc.) of multi-family housing in South Korea shows that water leaks are found from cracks in all areas of the underground structure caused by the degradation environment (water pressure by underground water, humidity, temperature, earth pressure, soil behaviour and vibration, etc.), which result in various problems, including mold, malodour, debonding of finishing materials, exfoliation, breakout, water leaks in electrical boxes, efflorescence, sedimentation of calcium hydroxide, decoloration, rusting, damages and pollution among others. Therefore, this study aims to analyse the current status of water leaks in underground structure and use the results as the basic data for developing a standard guideline for water leaks and maintenance by parts of the underground structure of multi-family housing.

  • PDF

Dispersive Wave Analysis of a Beam under Impact Load by Piezo-Electric Film Sensor and Wavelet Transform (충격하중을 받는 보에서 압전 필름센서와 웨이브렛 변환을 이용한 문산파동의 해석)

  • Kwon., Il-Bum;Choi, Man-Yong;Jeong., Hyun-Jo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.4
    • /
    • pp.215-225
    • /
    • 2001
  • Stress waves monitored on the surface of structures under various loading conditions can provide useful information on the structural health status. In this paper, stress waves are measured by several sensors when a steel beam is impacted by a ball drop. The sensors used include the piezo-electric film Sensor, the electrical strain gage, and the ultrasonic transducer, and special attention is given to the pieza film sensor. The wavelet transform is used for the time-frequency analysis of dispersive waves propagating in the beam. The velocities of the wave produced in the team due to the lateral impact is found to be frequency-dependent and identified as the flexural wave velocity based on the comparisons with the Timoshenko beam theory. A linear impact site identification method is developed using the flexural wave, and the impact sites of the beam can be accurately estimated by the piezo film sensors. It is found that the piezo film sensor is appropriate for sensing stress waves due to impact and for locating impact sites in the beam.

  • PDF

Neural Net Application Test for the Damage Detection of a Scaled-down Steel Truss Bridge (축소모형 강트러스 교량의 손상검출을 위한 신경회로망의 적용성 검토)

  • Kim, Chi-Yeop;Kwon, Il-Bum;Choi, Man-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.4
    • /
    • pp.137-147
    • /
    • 1998
  • The neural net application was tried to develop the technique for monitoring the health status of a steel truss bridge which was scaled down to 1/15 of the real bridge for the laboratory experiments. The damage scenarios were chosen as 7 cases. The dynamic behavior, which was changed due to the breakage of the members, of the bridge was investigated by finite element analysis. The bridge consists of single spam, and eight (8) main structural subsystems. The loading vehicle, which weighs as 100 kgf, was operated by the servo-motor controller. The accelerometers were bonded on the surface of 7 cross-beams to measure the dynamic behavior induced by the abnormal structural condition. Artificial neural network technique was used to determine the severity of the damage. At first, the neural net was learnt by the results of finite element analysis, and also, the maximum detection error was 3.65 percents. Another neural net was also learnt, and verified by the experimental results, and in this case, the maximum detection error was 1.05 percents. In future study, neural net is necessary to be learnt and verified by various data from the real bridge.

  • PDF

A Study on Analysis of Damaged Facilities in Rural Area by Storm and Flood Hazard (풍수해에 의한 농촌지역 피해시설 현황 분석)

  • Lim, Chang-Su;Oh, Yun-Kyung;Lee, Seung Chul;Kim, Eun-Ja;Choi, Jin-Ah
    • Journal of Korean Society of Rural Planning
    • /
    • v.22 no.2
    • /
    • pp.19-29
    • /
    • 2016
  • Disasters that occur most frequently in rural areas are drought, flood, damages from wind and cold weather. Among these, damages from storm and flood and drought are the main disasters and recently, these are occurring on a large scale due to unusual weather conditions. Under such circumstances, projects and researches on disasters in rural areas are under way but they are mostly targeting one area or making approaches focusing on repair facilities, maintenance project of facilities in small streams, and disaster management, so there have not been enough studies on the current status of overall damaged facilities in the rural areas. Against this backdrop, through the analysis of the current status of damaged facilities due to storm and flood in rural areas, this study aims to provide base data for policies needed for disaster recovery planning and maintenance work of rural areas. For the analysis of damaged facilities due to storm and flood in rural areas, using the annual report on disasters issued by Ministry of Public Safety and Security and based on the occurrence rate of estimated damage in each city and district for the past 10 years(2004~2013), 8 areas with the highest number of occurrence and cost of damage were found from each province and target areas were selected. Then, regarding the selected target areas, the General Plan for Reducing Damages from Storm and Flood, which is the report on top-level plan for preventing disasters, was secured and the current status of damaged facilities were analyzed. After organizing the analysis of current status, the tendency of damaged facilities due to storm and flood in rural areas, the items of damaged facilities depending on the types of storm and flood damages, and risk factors were suggested. Based on this result, in order to generalize the results of follow-up researches, it is thought that disaster recovery planning and establishing the system of remodeling items necessary for maintenance work would be possible by analyzing damage investigation items recorded in additional researches on rural areas, researches on natural disasters, and recovery plan instructions and by conducting on-site investigation on the damaged villages from storm and flood in rural areas.

Influential Factors on Size of Residential Space in Later Life (중년기 이후의 주거공간 규모에 영향을 미치는 특성)

  • 이인수
    • Journal of the Korean housing association
    • /
    • v.12 no.4
    • /
    • pp.93-104
    • /
    • 2001
  • This study has been performed to analyze size and deficit problem of residential space in later life. In this study, 216 Koreans aged 50 to 79 were surveyed for their current residential space ad family related items such as age, marital status, living arrangement, birth order, and housing status. The results are drawn as follows: 1. The space size significantly fluctuates by marital status, number of generations living together, tenure, and structure type; For example, use of indoor area per person ranges from 7.01 pyoung for three-generation households to 19.53 for one-generation households. 2. s for space deficit, very old widowed females, 60's living in rented or multi-family housing units, and those living in three generations are high risk groups of the space deficit below 7 young per person. In this study, further researches are recommended as follows; Regarding the highest risk group of space deficit, life styles causing space-related conflicts should be studied, and accordingly proper welfare services for the causal life styles be offered. Housing maintenance & utility costs be investigated and guidelines should be proposed for any surplus groups among the 60's, so that their space surplus can be reduced by suitable adjustment process.

  • PDF

Cefepime-induced nonconvulsive status epilepticus in a hemodialysis patient

  • Lee, Yoo Jin;Park, Bong Soo;Park, Kang Min;Kim, Il Hwan;Park, Jin Han;Park, Si Hyung;Kim, Yang Wook
    • Annals of Clinical Neurophysiology
    • /
    • v.20 no.2
    • /
    • pp.97-100
    • /
    • 2018
  • Nonconvulsive status epilepticus (NCSE) is an unusual complication in patients treated with cefepime. An 82-year-old woman on maintenance hemodialysis was given cefepime for pneumonia. Her level of consciousness decreased since the administration of cefepime, and she was diagnosed with NCSE based on electroencephalography (EEG) findings. After discontinuation of cefepime, improvement was seen both in the level of consciousness and EEG findings. Clinicians should be aware of cefepime-induced NCSE, particularly in patients with renal failure.