• Title/Summary/Keyword: Maintenance and Reinforcement

Search Result 542, Processing Time 0.025 seconds

Evaluation of Shear Performance of Reinforced Concrete Beams for Varying Reinforcement Details of Web Opening (유공부 보강상세에 따른 철근콘크리트 유공 보의 전단 성능 평가)

  • Kim, Min-Jun;Lee, Bum-Sik;Kim, Dong-Whan;Kim, Hyeong-Gook;Lee, Yong-Jun;Kim, Kil-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.19-26
    • /
    • 2018
  • This study evaluates the shear performance of reinforced concrete members with web opening reinforcement. A total of 4 reinforced concrete members with or without openings were cast then tested. The main variables investigated were with or without of web openings and with or without of web opening reinforcement, respectively. The proposed web opening reinforcement was a rectangle and rhombus-shaped spiral considering of construct ability. Test result showed that the proposed web reinforcement had improved shear capacity and ductility of the specimens. It was found that the web opening reinforcement proposed in this study had a positive effect on the shear strength and crack control of RC beams with web openings. In addition, it was confirmed that the analytical results by the current design codes underestimates the test results of the specimens with the proposed web opening reinforcement.

Analytical Study for Optimal Reinforcement Amount and Development of FRP Seismic Reinforcement that can be Emergency Construction (긴급시공이 가능한 FRP 내진보강재 개발 및 최적 보강량 산정을 위한 해석적 연구)

  • Kim, Jin-Sup;Kwon, Min-Ho;Seo, Hyun-Su;Lim, Jeong-Hee;Kim, Dong-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.136-145
    • /
    • 2013
  • Social interest in the seismic retrofit of the structure is growing massive earthquake that occurred recently. The brittle fracture of Non-seismically designed Columns lead to full collapse of the building. In the past, cross-sectional expansion method, a steel plate reinforcing method is applied mainly in recent years, fiber-reinforced method utilizing the advantages of the composite material are preferred. However, the reinforcement methods such as this, there is a drawback to induce physical damage to structures, and time consuming work space is large. IIn this study, FRP seismic reinforcement was developed using the Aluminum connector and the composite material (Glass Fiber Reinforced Polymer). Then, the optimum quantities of FRP seismic reinforcement was determined using a nonlinear finite element analysis program. Finally, the quantity decision process through the design and analysis of FRP reinforcement was suggested.

A Study on the Reliability of Detecting Reinforcement Embedded in Concrete in Various Factors Using Electromagnetic Induction Method and Electromagnetic Wave Method (전자기유도법과 전자파레이더법을 이용한 각종인자에 따른 철근탐사의 신뢰성에 관한 연구)

  • Kim, Jong-Ho;Oh, Kwang-Chin;Park, Seung-Bum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.4
    • /
    • pp.179-186
    • /
    • 2008
  • Probing inside of concrete structures is one of the important steps in assessing condition of the structure. For the assessment, electromagnetic induction method and electromagnetic wave method are currently applied to the measurement of cover depth, and the detection of reinforcement embedded in concrete. To determine detection capability of locating reinforcement embedded in concrete, commercially available nondestructive testing (NDT) equipments have been tested. The equipments include electromagnetic wave system and electromagnetic induction system. In the tests, nine concrete specimens which have the dimensions of 1,000mm(length))${\times}$300mm(width) with thickness varying from 125mm to 150mm are used. The reinforcement are located at 45, 60, 100mm depth from the concrete surface. Horizontal reinforcement spacing has been set over 100mm. From the outcome, it is shown that error is increased as the diameter of reinforcement enlarge in case of using electromagnetic induction method. In case of using electromagnetic wave method, the detection of reinforcement embedded in deep is good in the view of reliability because of using the relative permittivity on the real cover depth.

A Study on the Flexural Capacity of Rectangular Section Wood Using Synthetic Resins (합성수지를 이용한 사각단면 목재의 휨 보강 성능에 관한 연구)

  • Park, Kwang-Seob;Kang, Pyeong-Doo;Ha, Jong-Han;Park, Sung-Moo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.6 s.58
    • /
    • pp.106-114
    • /
    • 2009
  • The basis principle of conservation about deterioration and corrosion of cultural assets building is the archetype maintenance, and should not make a factitious damage mistake by repair. Accordingly, conservation processing method using synthetic resins is embossed. The purpose of this paper is about flexural capacity of rectangular section wood using synthetic resins, the 11 specimens are manufactured and made an experiment about reinforcement length, ratio, material strength, direction of synthetic resins as variable. The results of this paper has shown that flexural reinforcement of wood by synthetic resins are efficient and found the possibility of using.

A Study on the Shear Behavior of Strengthened R/C Beams with CFS (탄소섬유쉬트로 보강한 R/C보의 전단거동에 관한 연구)

  • Shin, Sung-Woo;Bahn, Byong Youl;Lee, Kwang Soo;Cho, In-Chol;Nam, Jeong-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.3
    • /
    • pp.205-211
    • /
    • 1998
  • The purpose of this study is to evaluate shear strengthening effects of R/C beams with carbon fiber sheets. The major variables are shear reinforcement ratios, CFS strengthening ratios and strengthening methods of CFS. Following conclusions can be extracted. The shear capacity of beam strengthened with CFS is about 32~87% higher than that of beams without shear reinforcement. The strengthening effects of patch type is larger than those of strip type. The strain distribution in CFS intersected with shear crack is similar to that in stirrup and larger strain is observed in the middle of the shear span. It can be estimated that shear strength reduction factor ${\alpha}$=0.3 is appropriate for peeling effect of CFS.

  • PDF

A Study on Structural Safety Evaluation of Improved PSC Beam Bridges Considering To-Box Reinforcement Effect (박스형 보강효과를 고려한 개선된 PSC Beam교의 구조 안전성 평가에 관한 연구)

  • Han, Sung Ho;Shin, Jae Chul;Bang, Myung Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.197-211
    • /
    • 2007
  • The deteriorated PSC Beam bridge is necessary improved reinforcement method. In the study, it is proposed the box reinforcing method which could make the stiffness of the PSC Beam bridges increase more stably through the secondary composition effect of open type PSC Beam bridge's girder which is converted into the consolidation box type and the half panel is formed between the lower flange of the PSC Beam about the deteriorated PSC Beam bridge suffering the capacity decline. In case the proposed reinforcement method combine with the existed external prestressed method, the close analysis depending on the time is conducted by the construction stage because of searching the effect of reinforcement quantitatively. The reinforcement method of the box type which is proposed an efficiency improvement in objective in application case, by a reinforcement method after proposing the whole and bend sectional reinforcement method, against a each reinforcement method evaluated the upward camber which it follows in secondary composite effect and a member stress characteristics. Also, the structural safety of PSC Beam bridge is evaluated quantitatively by examining of rating factor through load carrying capacity evaluation.

Evaluation of Bond Behavior of Reinforced Concrete Beams with High-Strength Transverse Reinforcement (고강도 횡보강근을 사용한 철근콘크리트 보의 부착 거동 평가)

  • Kim, Sang-Woo;Kim, Young-Sik;Baek, Seung-Cheol;Kim, Kil-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.5
    • /
    • pp.102-109
    • /
    • 2010
  • This paper investigates the bond behavior of reinforced concrete beams having high-strength transverse reinforcement. A total of four reinforced concrete beams were tested in this study to estimate the bond capacity of the proposed U-shape reinforcement. The proposed U-shape reinforcement not only has a simple structure to install, but also can increase the bond capacity of reinforced concrete beams by controling bond cracks. This study follow the test method proposed by Ichinose to obtain the bond stress and the bond slip of the specimens. The main test parameters were the yield strength, ratio, and reinforcing types of transverse reinforcements. It was found that the proposed U-shape reinforcement was able to effectively improve the bond performance of reinforced concrete beams with high-strength transverse reinforcement.

Maintenance Characteristics of Geotechnical Structures in Cold Region for Freeze Damage Analysis (동결피해분석을 위한 저온지역 지반구조물의 보수보강특성)

  • Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.3
    • /
    • pp.35-40
    • /
    • 2013
  • In most cases, Geotechnical Structures installed in freezing areas require extra countermeasures for reducing freeze damage. However, in terms of domestic tunnels, studies and case reports for geotechnical structures such as tunnels and retaining walls are not fluently carried out, causing lack of research about ways to decrease freeze damage. For these causes, domestic design criteria about structures does not specifically institutionalization for geotechnical structures. This research have done on-site investigation about tunnels, cut slopes and retaining walls. Also, this research includes the process of analyzing the histories of maintenance for class 1 and class 2 structures that happened in the past 40 years, studying characteristics of structure's maintenance and reinforcement in different areas with different climate. As the result, it was analyzed that domestic geotechnical structures showed need for longer maintenance and reinforcement that are located in Gangwon mountain area, Gangwon north region and Gyeonggi north region where the temperature is relatively low. This research can be concluded in need for revision of design criteria for structures located in freeze damage area.

Improvement and Evaluation for Seismic Resistant Capacity of Reinforced Concrete Shear wall with Connection Types and Diagonal Reinforcement (철근콘크리트 전단벽의 접합방식과 대각보강에 따른 내진성능 평가 및 개선)

  • Shin, Jong-Hack;Ha, Gee-Joo;An, Joon-Suk;Ju, Jung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.3
    • /
    • pp.139-147
    • /
    • 1999
  • Six reinforced concrete shear wall, constructured with fully rigid, slit, and infilled types, were tested under both vertical and cyclic loadings. Experimental programs were carried out to evaluate the seismic performance of such test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility, under load reversals. All the specimens were modeled in one-third scale size. Based on the test results, the following conclusions can be made. For the diagonal reinforced slit and infilled shear wall specimens, it was found that the failure mode shows very effective crack control and crushing due to slippage prevention of boundary region and reduction of diagonal tension rathar than the brittle shear and diagonal tension failure. The ductility of specimens designed by the diagonal reinforcement for the slit and infilled shear wall was increased 1.72~1.81 times in comparison with the fully rigid shear wall frame. Maximum horizontal load-carrying capacity of specimens designed by the diagonal reinforcement ratio the slit and infilled shear wall was increased respectively by l.14 times and l.49 times in comparison with the standard fully rigid shear wall frame.

  • PDF

A Experimental and Analytical Study on One directional Bond Behavior of Grid typed CFRP Reinforcement (격자형 탄소 보강재의 일방향 부착특성에 대한 실험 및 해석적 연구)

  • Chi Hoon Noh;Nak Seop Jang;Hongseob Oh
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.2
    • /
    • pp.77-86
    • /
    • 2024
  • In this study, authors attempted to determine the bond behavior characteristics to utilize Grid typed CFRP reinforcement as an alternative to steel rebar used as concrete reinforcement. Since it is difficult to understand the influence of the transverse grid length of the Grid typed CFRP reinforcement in the existing numerical analysis proposal for bond behavior, a nonlinear 3D model was created and finite element analysis was performed. To perform the analysis, the analysis was conducted by inputting a nonlinear material model and modeling the bond interface characteristics between the Grid typed CFRP reinforcement and concrete and comparing them with the actual direct pull-out test results. The bond behavior characteristics of the Grid typed CFRP reinforcement were found to be very dominated by the factors of the transverse grid, and showed a tendency to continuously increase load.