• Title/Summary/Keyword: Main circuit breaker

Search Result 53, Processing Time 0.03 seconds

The Study of relation most suitable betweenPantograp interface And Neutral Section (전기철도 절연구분장치와 팬터그래프 인터페이스 최적화에 관한 연구)

  • Kim, In-Chol
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.325-329
    • /
    • 2002
  • This paper is intended as an investigation of the interface between Neutral section insulators and pantograph interface. Neutral section insulators are installed at the boundary between AC catenary system and DC catenary system, which should provide electrical insolation between two different catenary systems and pass the trains without interruption. As the number of the pantographs installed on the train increased, which is necessary for the VVVF inverter drive trains introduced in recent years, there occurs an serious aspects of the interaction between pantographs and Neutral section insulators. These effects hinder the automatic switch operation of MCB(Main Circuit Breaker) after passing through the section insulators, and lead to the extra-ordinary wear of FRP insulator material of section insulators. Countermeasures in terms of the interface between the Neutral secton insulators and electric collection system of train are provided too.

  • PDF

Intelligent Diagnostic System of Photovoltaic Connection Module for Fire Prevention (화재 예방을 위한 태양광 접속반의 지능형 진단 시스템)

  • Ahn, Jae Hyun;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.161-166
    • /
    • 2021
  • To prevent accidents caused by changes in the surrounding environment or other factors, various protection facilities are installed at the photovoltaic connection module. The main causes of fire are sparks due to foreign substances inside the photovoltaic connection module through high temperature rise and dew condensation in the photovoltaic connection module, and fire due to heat from the power diode. The proposed method can predict the fire by measuring flame, carbon dioxide, carbon monoxide, temperature, humidity, input voltage, and current on the photovoltaic connection module, and when the fire conditions are reached, fire alarm and power off can be sent to managers and users in real time to prevent fire in advance.

Development of the Spark-gap Switch with Dual Trigger System (쌍방향 시동방식의 고속투입스위치 개발)

  • Kim, Maeng-Hyeon;Seo, Yun-Taek;Park, Seung-Jae;Park, Byeong-Rak;Go, Ui-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.7
    • /
    • pp.359-364
    • /
    • 2000
  • This paper is introducing a newly developed spark-gap switch with dual trigger system, into which the current from the voltage source is injected along with the test sequence during the synthetic testing of high voltage circuit-breaker. The currently-used spark gap switch is narrow in operating range due to the use of the method of triggering energy being injected by single way. As a result, the frequent happening of misoperation has greatly reduced the test quality and test efficiency and has required the cost of maintenance excessively. In this study, accordingly, in order to basically remove these problems, another triggering system is installed to the opposite direction on the existing triggering system; attaching the same time and the same rising time of pulse wave as on the existing system, so that at a comparatively trigger gap distance from the main electrode(the gap can be operated at 60% of self-break voltage, while at 80% in the current system), the main electrode has been enabled to be closed by the development of spark gap switch with dual trigger system.

  • PDF

Development of a Low-Price Device for Standby Power Cut-off (저가형 대기전력 차단장치 개발)

  • Lee, Sang-Yun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.3
    • /
    • pp.115-121
    • /
    • 2015
  • A device which could cut off the consumption of standby power by electric or electronic devices at homes and offices while waiting for a command to carry out the main functions from the inside or the outside was developed at a low price. Efforts to save standby power have been made on a global scale as well as by advanced countries. The consumption of standby power in South Korea is also increasing gradually due to increasing trend in the number of electronic and electric devices per household, becoming a major factor for waste of electric energy. The previous standby power cutoff devices themselves have high electric energy consumption and complicated structures, making the purpose less meaningful. Therefore, a low-priced standby power cutoff device is suggested in this study, which compensates such problems and cuts off the consumption of standby power completely. The circuit of the suggested standby power cutoff device was designed and implemented by applying it to an earth leakage breaker and an (electrical) outlet. Experimental results show its superiority.

Effects of Reclosing for Insulation Coordination in 345kV Combined Transmission Lines (345kV 혼합송전선로에서 재폐로가 절연설계에 미치는 영향)

  • Lee, Jong-Beom;Jung, Chae-Kyun;Lim, Kwang-Sik;Kang, Ji-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.847-853
    • /
    • 2010
  • This paper describes switching surge analysis for reclosing decision in 345kV combined transmission line with XLPE power cable. Reclosing operation should be decided based on the detailed technical analysis in combined transmission line because this line includes power cable section which is week on insulation. Insulation of power cable can be breakdown at the week point in case of reclosing moment. Therefore the detailed analysis has to be carried out by considering several conditions such as length ratio of power cable section, arrestor, inserting resistance, charging rate, grounding resistance, etc.. On the other hand sheath voltage on IJ(Insulated Joint) is analyzed to check dangerous condition on cable cover. Analysis is performed by EMTP/ATP. Analysis results show that reclosing can be operated as the single line-to-ground fault occurs on overhead line in 345kV combined transmission line, if the inserting resistance is considered before the operation of main circuit breaker.

Design of Controller for Reducing In-Rush Current of Single-Phase Induction Motor (단상유도전동기의 돌입전류저감을 위한 제어기 설계)

  • Park, Su-Kang;Baek, Hyung-Lae;Lee, Sang-Il
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.5
    • /
    • pp.238-245
    • /
    • 2001
  • During an AC motor's start-up accelerating period, a large amount of current is required to reach to the rating speed. This is called in-rush current. This peak in-rush current can be more than about several times the operating or steady-state current in the full load rating of the motor. In-rush current is present in both and electronic ballasts. The main area of concern is the tripping of circuit breaker and fuses which can affect electrical system components From this, we can see that the electrical power controllers will be rather concerned, since they have to supply the actual current necessary to start the motor. This paper presents a new method to reducing in-rush current and energy saving of the single-phase induction motor used in air-conditioner. It can be obtained that proposed system is low cost and small size as compared with other controller. Experiments are focused on a capacitor starting single-phase induction motor. The optimal power saving and in-rush current limiting by phase angle control are verified by experimental results. Also, auxiliary winding was controlled by electronic starting switch.

  • PDF

Review of Typical Fault Current Limiter Types and Application Effect to Improve Power System Reliability (전력 계통 신뢰도 개선을 위한 대표적인 한류기 유형 및 적용 효과 분석)

  • Yun-Seok Ko;Woo-Cheol Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.6
    • /
    • pp.1133-1142
    • /
    • 2023
  • A rapid increase in power capacity in a power system can seriously reduce system reliability by causing the fault capacity to exceed the breaking capacity of circuit breaker. Fault current limiter is a practical and effective way to improve reliability by limiting fault capacity to the breaking capacity level. In this study, in order to help develop an application methodology when applying fault current limiters to power systems, first the topology and operating principles of each type of fault current limiters was reviewed, and the main advantages and disadvantages was compared. Next, to verify the effect of applying fault current limiter to the power system, the power system in which the fault current limiter was introduced was modeled. Finally, after simulating a three-phase short-circuit fault using EMTP-RV, the effect of application was verified by comparing the fault current before and after application of the fault current limiter and confirming that the fault current was reduced by the fault current limiter.

Effective Protection Methods of Household Electric Appliances. from Lightning Surges (가정용 전기기구의 효과적인 뇌서지 보호기법)

  • 이복희;강성만;엄주홍;이수봉;길형준;구본완;안창환
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.3
    • /
    • pp.149-156
    • /
    • 2004
  • This paper deals with the effective protection method for the household electric appliances against lightning surges invading from the Power lines. Direct or induced lightning is the main cause of the breakdown of household electric appliance. The most effective protection method is to install SPDs(surge protective devices) at household electric appliances. If SPDs were not installed at most household electric appliances, it is necessary to install SPDs on the mains. Therefore the propagation aspect and protection methods of lighting surges coming into household electric appliances through the mains was experimentally investigated. The in actual-sized test circuits results of protection method for 8 household electric appliances including computer monitors and TV set could be summarized as follows: The breakdown characteristics of household electric appliances from lightning surges were significantly changed with the their input impedance. Namely, the types of input impedance are classified into infinite, resistive or inductive impedances. Especially, the monitor for computer with inductive input impedance from lightning surges was relatively weak against lightning surges. It was confirmed that the self inductance of branch circuits on the mains have protection effect for household electric appliances against lightning surges invading from the power lines. Also the varistors installed at cabinet panel or circuit-breaker were more effective than multi-tap outlet with varistors. When installed varistors in cabinet panel and multi-tap outlet together, the surge protection effect is much more excellent in technical and economical aspects.

A study on the cause Analysis and solution of an overheated NGR of the Main Transformer (변압기 중성점 접지리액터 과열원인분석 및 해소방안에 관한 연구)

  • Park, Gil-Soo;Park, Soo-Hong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.2
    • /
    • pp.262-267
    • /
    • 2011
  • In the power system, the transformer's neutral earth reactor line 1 grounding failure may occur. By limiting the magnitude of the failure grounding current flow, it will aid to reduce the failure of the transformer. Consequently, this also may avoid the failure of the disconnection of the industrial insulator line that cause by melting. Besides, utilizing the decreasing circuit breaker or others related equipment can use to avoid the possibility of explosion of the transformer. If the failure happen during the operation of the power system, a huge interference will definitely may occur. Therefore, by installing the DONGBUSAN S/S #3M.Tr neutral earth reactor among TOP and BOTTOM BRACE part in the power system, the causes of the rising temperature and reason of the over-current flow that cause by over-current can be analyze.

A 3-D Steady-State Analysis of Thermal Behavior in EHV GIS Busbar

  • Lei, Jin;Zhong, Jian-ying;Wu, Shi-jin;Wang, Zhen;Guo, Yu-jing;Qin, Xin-yan
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.781-789
    • /
    • 2016
  • Busbar has been used as electric conductor within extra high voltage (EHV) gas insulated switchgear (GIS), which makes EHV GIS higher security, smaller size and lower cost. However, the main fault of GIS is overheating of busbar connection parts, circuit breaker and isolating switch contact parts, which has been already restricting development of GIS to a large extent. In this study, a coupled magneto-flow-thermal analysis is used to investigate the thermal properties of GIS busbar in steady-state. A three-dimensional (3-D) finite element model (FEM) is built to calculate multiphysics fields including electromagnetic field, flow field and thermal field in steady-state. The influences of current on the magnetic flux density, flow velocity and heat distribution has been investigated. Temperature differences of inner wall and outer wall are investigated for busbar tank and conducting rod. Considering the end effect in the busbar, temperature rise difference is compared between end sections and the middle section. In order to obtain better heat dissipation effect, diameters of conductor and tank are optimized based on temperature rise simulation results. Temperature rise tests have been done to validate the 3-D simulation model, which is observed a good correlation with the simulation results. This study provides technical support for optimized structure of the EHV GIS busbar.