• 제목/요약/키워드: Main Power Transformer

검색결과 192건 처리시간 0.025초

Bus Reconfiguration Strategy Based on Local Minimum Tree Search for the Event Processing of Automated Distribution Substations

  • Ko Yun-Seok
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.177-185
    • /
    • 2005
  • This paper proposes an expert system that can enhance the accuracy of real-time bus reconfiguration strategy by adopting the local minimum tree search method and that can minimize the spreading effect of the fault by considering the operating condition when a main transformer fault occurs in an automated substation. The local minimum tree search method is used to expand the best-first search method. This method has the advantage that it can improve the solution performance within the limits of the real-time condition. The inference strategy proposed expert system consists of two stages. The first stage determines the switching candidate set by searching possible switching candidates starting from the main transformer or busbar related to the event. The second stage determines the rational real-time bus reconfiguration strategy based on heuristic rules from the obtained switching candidate set. Also, this paper proposes generalized distribution substation modeling using graph theory, and a substation database based on the study results is designed.

DC 전압이 유입변압기 절연시스템에 미치는 영향에 관한 연구 (Study on the effect of DC voltage in oil-immersed transformer insulation system)

  • 장효재;김용한;석복렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1552-1553
    • /
    • 2011
  • The HVDC transformer which is one of the main equipments for HVDC(High Voltage Direct Current) electric power transmission systems is exposed to not only AC voltage but also the inflowing DC voltage which comes from the DC-AC converter systems. Therefore, the HVDC transformer insulation system is required to withstand the electric field stress under AC, DC and DC polarity reversal conditions. However the electric field distributions under those conditions are different because the AC electric field and DC electric field are governed by permittivity and conductivity, respectively. In this study, the changes of electric potential and electric field of conventional AC transformer insulation system under DC polarity reversal test condition were analyzed by FEM(Finite Element Method). The DC electric field stress was concentrated in the solid insulators while the AC electric field stress was concentrated in the mineral oil. In addition, the electric stress under that condition which is affected by the surface charge accumulation at the interfaces between insulators was evaluated. The stress in some parts could be higher than that of AC and DC condition, during polarity reversal test. The result of this study would be helpful for the HVDC transformer insulation system design.

  • PDF

Series Compensated Step-down AC Voltage Regulator using AC Chopper with Transformer

  • Ryoo, H.J.;Kim, J.S.;Rim, G.H.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권3호
    • /
    • pp.277-282
    • /
    • 2005
  • This paper describes a step-down AC voltage regulator using an AC chopper and auxiliary transformer, which is a series connected to the main input. The detail design of the AC regulator, logic and PWM pattern of the AC chopper is described and the three-phase AC regulator using two single­phase AC choppers with a three transformer configuration is proposed for three-phase application. The proposed three-phase system has the advantages of lower system cost due to reduced switch number and gate driver circuit as well as advantages of decreased size and weight because it uses a series compensated scheme. The proposed AC regulator has many benefits such as fast voltage control, high efficiency and simple control logic. Experimental results indicate that it can be used as a step-down AC voltage regulator for power saving purposes very efficiently.

변압기 부하패턴 분석을 위한 시간 데이터마이닝 연구 (Study of Temporal Data Mining for Transformer Load Pattern Analysis)

  • 신진호;이봉재;김영일;이헌규;류근호
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1916-1921
    • /
    • 2008
  • This paper presents the temporal classification method based on data mining techniques for discovering knowledge from measured load patterns of distribution transformers. Since the power load patterns have time-varying characteristics and very different patterns according to the hour, time, day and week and so on, it gives rise to the uninformative results if only traditional data mining is used. Therefore, we propose a temporal classification rule for analyzing and forecasting transformer load patterns. The main tasks include the load pattern mining framework and the calendar-based expression using temporal association rule and 3-dimensional cube mining to discover load patterns in multiple time granularities.

진도-제주 HVDC 변환설비 소음특성 분석 (Analysis of Acoustic Noise Characteristics of Jindo-Cheju HVDC)

  • 김재한;김찬기;이성두;김진영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.574-576
    • /
    • 2010
  • HVDC converter station consists of a number of noise sources such as converter transformer, ac filter, cooling system and so on. In this paper, we analyzed the simulation results of the outdoor acoustic noise characteristics for HVDC converter station. It shows that maximum noise level in boundary of HVDC converter station exceeds regulation value. The main factors in generating maximum noise level are ac filter and converter transformer. Then we applied some soundproof countermeasure in HVDC converter station. Shielding wall is enough to reduce transformer noise level but not enough to reduce ac filter noise level. In case of ac filter, soundproof building is effective in satisfying noise level regulation in boundary of HVDC converter station. In addition, we also studied effects of season, soundproof woods, ground.

  • PDF

$SF^6 $ 가스변압기의 탭절환기용 스페이서의 절연내력에 관한 연구 (A study of Dielectric Strength of Spacer for Tap Changer in a $SF^6 $ Gas Insulated Transformer)

  • 허우행;하영식;홍정균;김규탁
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권11호
    • /
    • pp.556-562
    • /
    • 2001
  • Spacer is used between main tank and auxiliary tank for on load tap changer in gas insulated power transformer. This paper deals with electrical design of spacer and discusses different analysis method of between 2D FEM(finite element method) and 3D FEM. To design spacer, we modeled structure of two kind of coaxial cylinders of spacer conductors and analysised electric field of spacer at impulse and induced test voltage condition. Spacer has 13 conductors and electric field was changed according to arrangement of conductors. We could find out arrangement of conductors at which electric stress is minimum. And this arrangement was satisfied with actual test conditions.

  • PDF

아크 용접에 적합한 영전압영전류 방식의 풀브릿지 컨버터 (A Zero-Voltage and Zero-Current Switching Full Bridge DC-DC Converter for Arc Welding Machines)

  • 전성즙
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권6호
    • /
    • pp.342-348
    • /
    • 1999
  • A new welding machine which adopts zero voltage and zero current switching(ZVZCS) full bridge(FB) DC-DC converter is proposed. The proposed ZVZCS FB DC-DC converter uses auxiliary transformer to obtain ZCS for leading leg. It has capability of controlling load current even in short circuit condition and is suitable for arc welding machines. The power rating of the auxiliary transformer is about one 5th to one 10th of the main transformer. Experimental results for 10KW prototype are shown to verify the principle of operation.

  • PDF

새로운 영전압 스위칭 2-트랜스포머 승압형 컨버터 (A New Zero-Voltage-Switching Two-Transformer Boost Converter)

  • 박기범;김정은;문건우;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.292-294
    • /
    • 2005
  • A new zero voltage switching (ZVS) 2-transformer boost converter is proposed in this paper. The proposed converter has the advantage that the magnetizing inductor of the transformer acts for the boost inductor without additional inductor. Moreover, ZVS of main switches and auxiliary switches can be achieved, and the switch turn-off surge problem of conventional isolated boost converter is effectively solved. The operational principle, DC voltage gain, and ZVS characteristics are analyzed. To confirm the validity of the proposed converter, simulation results with 200w, 24Vdc/200Vdc specification are presented.

  • PDF

진동신호 분석을 위한 On-Line 시스템 개발 (Developement of On-Line System for Vibration Signal Analysis)

  • 김언석;임성정;김영식;이영길;김재철;정찬수;정상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.616-619
    • /
    • 1995
  • This paper describes developement of on-line system for vibration signal analysis. In the power system, the main reason of transformer fault is due to a large amount of current by a short-circuit and a ground-fault. The electromagnetic force caused by fault-current deforms transformer windings and results in vibration pattern change. Therefore if the continuous on-line vibration monitoring on transformer is performed, an incipient failure can be detected. The developed system is composed of data acquisition devices, user interface program, signal processing program, diagnosis and trend analysis program, self diagnosis program and communication program.

  • PDF

저주파용 고전압 구형파 발생장치의 개발 (Development of high-voltage rectangu1ar waveform generator operating in low-frequency domain)

  • 이복희;최원규;장석훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.959-961
    • /
    • 1998
  • In this paper, we present design rule of high-voltage rectangular generator working in wide band frequency domain. Though power electronics now have voltage ratings up to several kV, it is difficult to design and fabricate high-voltage systems with the power electronic devices alone. So we have combined IGBT with technically designed transformer to get the high-voltage rectangular waveforms. In this work, next two things are the main factors. The first one is design of transformer working low-frequency domain of less than 10Hz. And the second one is adding offset voltage part. As a result, we can get variable frequency high-voltage rectangular waveform and this can be used as a voltage source of sandpaper manufacturing process.