검색결과 62건 처리시간 0.024초

브레이커 소음측정시스템을 활용한 소음의 측정 및 평가 (Measurement of Breaker Noise by Using Breaker Noise Measurement System)

  • 이재원;강대준;구진회;박형규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1173-1176
    • /
    • 2007
  • The breaker noise is one of the main noise sources of construction site. It is very important to assess and measure the breaker noise accurately, because the noise labelling will be in effect January 2008 in Korea. Therefore, It is necessary to measure the sound power level of breakers and use a appropriate test method in accordance with international standard. In this study, we measure the sound power level of breakers by using the breaker noise measurement system. This system makes it possible to measure the breaker noise more accurately than to measure the noise of that attached with excavator, because this system can control main factors affecting breaker noise such as hydraulic input power, hydraulic supply pressure, breaker inlet oil flow and so on.

  • PDF

주회로차단기 투입전원 위상제어를 위한 지능형 제어기 개발 (A Development of Intelligent Controller for Phase Control in Main Circuit Breaker)

  • 오용국;김재원;류준형
    • 한국산학기술학회논문지
    • /
    • 제18권11호
    • /
    • pp.755-761
    • /
    • 2017
  • 교류 철도차량에 사용되는 주회로차단기 (Main Circuit Breaker)는 전차선 전원을 차량 내 투입 또는 차단하는 기능을 한다. 일반적으로 주회로차단기는 판토그라프와 주변압기 사이에 위치하며, 주회로차단기의 동작시점에 따라 차량에 투입되는 전원의 위상이 변화하게 된다. 투입전원의 위상에 따라 차량 내 돌입전류, 서지전압 등의 형태로 차량 전기장치 내 의도하지 않은 과도현상이 야기될 수 있으므로, 주회로차단기의 동작은 전차선 전원의 위상각에 따라 능동적으로 제어되어야 한다. 하지만 주회로차단기는 동작신호 인가 이후, 실제 개폐 동작 시까지 일정하지 않은 동작지연시간이 존재한다. 따라서 동작 지연시간을 예측하고, 이를 고려하여 주회로차단기를 개폐시점을 제어하는 지능형 제어기가 필요하다. 본 논문에서는 주회로차단기의 투입전원 위상 제어를 위하여 동작 메카니즘 및 동작 지연요소를 분석하였다. 그리고 차단기 및 구성품 별 반복동작시험을 통하여 동작 지연시간을 분석하고, 이를 예측하기 위한 이동평균 (Moving Average) 알고리즘을 제안하였다. 또한 지능형 제어기 개발 및 제작을 통하여 제안된 알고리즘을 구현하였으며, 주회로차단기와의 연동시험을 통하여 알고리즘의 성능을 검증하였다.

원자력발전소의 발전기차단기 설계요건 검토 (Design requirements for Generator Circuit Breaker)

  • 지문구;한성흠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.371-373
    • /
    • 2001
  • Main functions of Generator Circuit Breaker(GCB) is cut the generator off from the main transformers and the aux. transformers when plant trip or startup. In this paper, the design requirements For GCB of nuclear power plant is examined. NRC presented the area of review, acceptance criteria and review procedures of GCB in the SRP(Standard Review Plan). In Korea, APR1400 adapted the GCB in main power system.

  • PDF

전기철도차량 주변압기의 %임피던스에 따른 차단기 개폐시 과도특성 분석 (Transient Characteristics by Transformer %Impedance at the time of Opening the Main Circuit Breaker on the Electric Railway Vehicle)

  • 창상훈
    • 전기학회논문지
    • /
    • 제63권5호
    • /
    • pp.719-725
    • /
    • 2014
  • Transient of Electric railway vehicle occurs when change to another state. The duration of the transient phenomenon only takes a few second. During this time is considered, the present of short circuit current and the normal state, the energy is present in the form of a magnetic field. Recognized by the vibration of the transient voltage or transient current at witch energy is present in the field. This paper is presented the result of transient characteristics by transformer % impedance at the time of opening and closing of the main circuit Breaker on the electric railway vehicle.

저압용차단기 전원 개폐시 개인용 PC에 미치는 영향 분석 (Analysis of Effect on Personnel Computer in case of turning off Power supply of Circuit Breaker for Low Voltage)

  • 길형준;송길목;김영석;김종민
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.124-129
    • /
    • 2014
  • This paper describes the analysis of the effect on personnel computer in case of turning off power supply of main breaker in general electrical installation. In order to analyze the effect on personnel computer in case of turning off the power supply of main breaker, the switching impulse generator has been designed and fabricated which makes it possible to evaluate the effect on electrical product by switching impulse. The switching impulse tests were carried out for personnel computer according to applied voltage and number of switching impulse. As a consequence, switching impulse had not a significant influence on personnel computer in this study. The varistor of power input section functions as a protection of switching impulse as well as lightning impulse. The results will be used to related organization, and electrical product manufacturer, and residents.

밀폐용기내 압력변화를 이용한 유압식 브레이커의 타격에너지 시험법 개발 (Development the Test System of Impact Energy Using the Pressure Variation in Closed Vessel for Hydraulic Breaker)

  • 이근호;이용범;이기용
    • 연구논문집
    • /
    • 통권32호
    • /
    • pp.45-53
    • /
    • 2002
  • Hydraulic breaker attached excavator generally used for the destroying and disassembling of buildings, crashing road pavement, breaking rocks at quarry and etc. The developed breaker are determined their own destructive force and number of impact by the input hydraulic flow rate and pressure than the operating conditions, In this study, the characteristics of pressure variation in closed vessel is invested for testing the impact energy of hydraulic breaker. To test the impact energy, the test system is designed as a mechanism consisted with a hydraulic cylinder, main base, pressure sensor, LVDT, data acquisition system and etc.. The developed test system is applied to measure the impact energy for hydraulic breaker. The proposed testing method could be applied for conventional impact test and the control system evaluation for hydraulic breakers.

  • PDF

직류 철도용 MOV 병렬연결 1,800V급 IGBT 직류 고속차단기 연구 (IGBT DC Circuit Breaker with Paralleled MOV for 1,800V DC Railway Applications)

  • 한문섭;이장무;김주락;창상훈;김인동
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2109-2112
    • /
    • 2016
  • The rate of rise of the fault current in DC grids is very high compared to AC grids because of the low line impedance of DC lines. In AC grids the arc of the circuit breaker under current interruption is extinguished by the zero current crossing which is provided naturally by the system. In DC grids the zero current crossing must be provided by the circuit breaker itself. Unlike AC girds, the magnetic energy of DC grids is stored in the system inductance. The DC circuit breaker must dissipate the stored energy. In addition the DC breaker must withstand the residual overvoltage after the current interruption. The main contents of this paper are to ${\cdot}$ Explain the theoretical background for the design of DC circuit breaker. ${\cdot}$ Develop the simulation model in PSIM of the real scaled DC circuit breaker for 1,800V DC railway. ${\cdot}$ Suggest design guidelines for the DC circuit breaker based on the experimental work, simulations and design process.

2중 한류 구조를 갖는 배선용 차단기의 차단성능 평가 연구 (A Study on Estimation of Interrupting capability on Molded Case Circuit Breaker including Current Limiting Unit)

  • 김용기;송중천;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.144-146
    • /
    • 2002
  • The latest development flow of MCCB(Molded Case Circuit Breaker) is largely separated from which are high capability of interrupting compact of size and multi-ability in functions. As follow of development of industrial system. MCCB which are including communication function and having a ultimate interrupting capability is required in electrical system. to attain an effective limitation of the peak let-through current and the let-through energy, the arc has to move rapidly off the contacts and has to increase the arc voltage which mainly effect to interrupt. In this paper. we made high performance circuit breaker which including current limiting unit which is attached to the main which is simulated by CAE tool that are repulsion force and mechanical dynamics after that we tested and finally selected optimized for circuit breaker.

  • PDF

ANSI/IEEE를 적용한 초고압 차단기의 차단시험 (Breaking test of UHV circuit breaker by ANSI/IEEE standard)

  • 박승재;류형기;강영식;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.467-469
    • /
    • 2003
  • IEC(International Electrotechnical Commission) 62271-100 has been adopted for the design test of circuit breaker which is used as the main protecting device of power system. But, it is also necessary to separately receive the testing certificate in accordance with ANSI/IEEE standard for getting into the american market. Up to now, several domestic companies have completed the ANSI/IEEE testing in medium circuit breaker of distribution system, but they recently started the ANSI/IEEE testing in ultra high-voltage class of transmission and substation system. This paper introduces the testing techniques and its results for the making and breaking performance of 145kV, 40kA $SF_6$ gas circuit breaker which was firstly performed in KERI(Korea Electrotechnology Institute) by the ANSI/IEEE standard.

  • PDF

고장계산 및 보호협조 판정 소프트웨어 개발 (A Development of Software about Short-circuit Calculation and Protective-coordination)

  • 박성찬;최장흠;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.159-162
    • /
    • 2002
  • A software, called touch-one, is developed about the determination of short-circuit values and protective co-ordination in power system. The used solution algorithm reviewed intensively, and the protective co-ordination determination technique presented by using the circuit-breaker's current-limitation characteristic. The protective coordination concerns the behaviour of two devices placed in series in an electrical network, with a short-circuit downstream circuit-breaker. It has two basic principles: First, discrimination which is an increasing requirement of low voltage electrical distribution systems. Second, which is less well known: cascading, which consists of installing a device, whose breaking capacity is less than the three-phase short-circuit current at its terminals and helped by main circuit-breaker. With this software, we can construct a electric-power system which is reliable and economic according to user's purpose.

  • PDF