• Title/Summary/Keyword: Main Air-ratio

Search Result 286, Processing Time 0.029 seconds

Shear Behavior of Reinforced Concrete Deep Beams with Web Openings (개구부를 갖는 철근콘크리트 깊은 보의 전단거동)

  • 이진섭;김상식
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.6
    • /
    • pp.619-628
    • /
    • 2001
  • In building construction, openings of the story-height deep beams are usually required for accessibility and service lines such as air conditioning ducts, drain pipes and electric units. It is known that the main parameters affecting the load bearing capacity of deep beams with web openings are size, shape, location and reinforcements of openings. However, there have been no pertinent theories and national design codes for predicting ultimate shear strength of reinforced concrete deep beams with web openings. In this study, the shear behavior of simply supported reinforced concrete deep beams with web openings subject to concentrated loads has been scrutinized experimentally. A total of 34 specimens, the geometry of openings, its reinforcements and shear span to depth ratio, being taken as the experimental variables, has been cast and tested in the laboratory. The effects of these structural parameters on the shear strength and crack initiation and propagation have been carefully checked and analyzed. From the tests, it has been observed that the failures of all specimens were due to shear mechanism and the ultimate strength of specimens varies according to the location of openings, by which the formation of compression struts between the loading points and supports are deterred. All of the test results of specimens have been compared with the formulas proposed by previous researchers. The results were closely coincident with the formulas given by Ray and Kong's equation except for some X series specimens having a larger dimension of openings beyond the geometric limits of proposed equations.

A Study on the Production of Landfill-Cover Material Using the Physical Characteristics of Sludge and the Reduction of Odor (슬러지의 물리적 특성을 이용한 매립복토재 생산과 악취저감에 대한 연구)

  • Park, Jung Hyun;Yeo, Woon Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.28 no.2
    • /
    • pp.15-29
    • /
    • 2020
  • The aims of this study is to improve physical properties of the sewage sludge and the process sludge generated in the leachate treatment by mixing the dry fuel, to develop the neutral solidifing agents that reduce oder, and to recycle the sewage and the process sludges as landfill cover materials. The mixing ratio (W/W) of sludges and dry fuel was appropriate at about 1:1, and the mixed materials were shown to be homogeneous at that ratio. We could know that when the sludges were mixed with dry fuel, moisture contents and viscosities are reduced, and air passages are formed between particles and particles. The various mixing tests and odor tests showed that the neutral solidifing agent was effective for the odor reduction. The main ingredient of the solidifing agent is the ash of sewage sludge, enabling it competitive in waste recycling and production costs. The landfill cover, using developed neutral solidification agent, improved physical properties to satisfy the quality standards and to increase the compressive strength. It also proved to reduce the value of complex oder and the usage of solidification agent to 1/3 (3,000 to 1,000) and to 1/8 (50% to 6%), respectively, from the comparative study with alkaline solidified landfill cover. Further research is under way to prove that this can be mixed with general soil to be used as a soil improvement agent for plant cultivation.

Comparison of Growth Characteristics and Ginsenosides Content of 6-Year-Old Ginseng (Panax ginseng C. A. Meyer) by Drainage Class in Paddy Field (논토양에서 배수등급별 6년근 인삼의 생육특성 및 진세노사이드 함량 비교)

  • Lee, Sung-Woo;Park, Jin-Myeon;Kim, Geum-Soog;Park, Kee-Choon;Jang, In-Bok;Lee, Seung-Ho;Kang, Seung-Won;Cha, Seon-Woo
    • Korean Journal of Medicinal Crop Science
    • /
    • v.20 no.3
    • /
    • pp.177-183
    • /
    • 2012
  • To develop the practical cultivation for paddy field, we investigated the properties of paddy soil, growth characteristics and ginsenoside content of 6-year-old ginseng, Cheonpung variety between poor drainage class (PDC) and imperfect drainage class (IDC). Groundwater level in PDC showed monthly small changes of 20~30 cm, while IDC showed monthly great changes of 28~71 cm depending on rainfall. Soil moisture content in PDC and IDC was 17.2%, 22.5%, respectively. Air temperature in IDC was lower than $0.3^{\circ}C$, while soil temperature was higher than $0.8^{\circ}C$ compare to PDC, respectively. Main soil color of PDC was grayish olive, while IDC was brownish olive. PDC showed yellowish mottles only at underground of 20~40 cm, while IDC showed that at underground of 30~90 cm. IDC showed lower pH, EC, potassium, calcium and magnesium content, but higher organic matter, phosphate, and iron content than that of PDC, respectively. All of EC, organic matter, potassium, calcium, and magnesium content were decreased, but iron content was increased at the subsoil layers of PDC. All of EC, organic matter, phosphorus, and potassium content were decreased, but calcium and magnesium content were increased at the subsoil layers of IDC. Root yield in IDC was more increased by 33% than that of PDC. The moisture content and rusty ratio of ginseng root in IDC were lower than that of PDC. Ginsenoside content in IDC was higher than that of PDC because the ratio of lateral and fine root showing relatively high content of ginsenoside was higher in IDC than that of PDC.

The Comparison of Quantitative Accuracy Between Energy Window-Based and CT-Based Scatter Correction Method in SPECT/CT Images (SPECT/CT 영상에서 에너지창 기반 산란보정과 CT 기반 산란보정 방법의 정량적 정확성 비교)

  • Kim, Ji-Hyeon;Son, Hyeon-Soo;Lee, Juyoung;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.93-101
    • /
    • 2015
  • Purpose In SPECT image, scatter count is the cause of quantitative count error and image quality degradation. Thus, a wide range of scatter correction(SC) methods have been studied and this study is to evaluate the accuracy of CT based SC(CTSC) used in SPECT/CT as the comparison with existing energy window based SC(EWSC). Materials and Methods SPECT/CT images were obtained after filling air in order to acquire a reference image without the influence of scatter count inside the Triple line insert phantom setting hot rod(74.0 MBq) in the middle and each SPECT/CT image was obtained each separately after filling water instead of air in order to derive the influence of scatter count under the same conditions. In both conditions, Astonish(iterative : 4 subset : 16) reconstruction method and CT attenuation correction were commonly applied and three types of SC methods such as non-scatter correction(NSC), EWSC, CTSC were used in images filled with image. For EWSC, 9 sub-energy windows were set additionally in addition to main(=peak) energy window(140 keV, 20%) and then, images were acquired at the same time and five types of EWSC including DPW(dual photo-peak window)10%, DEW(dual energy window)20%, TEW(triple energy window)10%, TEW5.0%, TEW2.5% were used. Under the condition without fluctuations in primary count, total count was measured by drawing volume of interest (VOI) in the images of the two conditions and then, the ratio of scatter count of total counts was calculated as percent scatter fraction(%SF) and the count error with image filled with water was evaluated with percent normalized mean-square error(%NMSE) based on the image filled with air. Results Based on the image filled with air, %SF of images filled with water to which each SC method was applied is NSC 37.44, DPW 27.41, DEW 21.84, TEW10% 19.60, TEW5% 17.02, TEW2.5% 14.68, CTSC 5.57 and the most scattering counts were removed in CTSC and %NMSE is NSC 35.80, DPW 14.28, DEW 7.81, TEW10% 5.94, TEW5% 4.21, TEW2.5% 2.96, CTSC 0.35 and the error in CTSC was found to be the lowest. Conclusion In SPECT/CT images, the application of each scatter correction method used in the experiment could improve the quantitative count error caused by the influence of scatter count. In particular, CTSC showed the lowest %NMSE(=0.35) compared to existing EWSC methods, enabling relatively accurate scatter correction.

  • PDF

A Study on the Material and Production Method of Bronze Casting Earthen Mold - Focusing on Earthen Mold Excavated in Dongcheon-dong, Gyungju - (청동주조 토제범(土製范)의 재질과 제작기법 연구 - 경주 동천동 출토 토제범을 중심으로 -)

  • Son, Da-nim;Yang, Hee-jae
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.4
    • /
    • pp.108-125
    • /
    • 2013
  • This study examined the actual reconstruction drawing, composite mineral, particle size and property test, fine organic matters, color differences and main ingredients of the earthen mold excavated in Dongcheon-dong, Gyungju. The cross-section of the inner mold and outer mold divides into inside (1st layer) and outside (2nd layer), with organic matters mixed outside. The cross-section has been altered due to heat and form removal agent. X-ray analysis revealed that the layer was made of minerals with high transmissivity and only quartz particles were observed through a polarizing microscope. The inside of cross-section in SEM observation identified enlarged air gap, with crack developed in the center, but no changes observed on the outside. The particle size of the composites is almost the same for the inner mold and outer mold and is silt clay loam. The ratio between silt clay and silt clay loam was about 2.7:1 and 2.9:1 respectively. In the property test, the density and absorption rate of inner mold and outer mold were similar, but porosity was different, with inner mold of 27.36% and outer mold of 31.09%. The color difference of cross-section seems to have been caused by the spread of soot on the 1st layer surface for removal of form or by the covering of ink to protect the 1st layer. Composite mineral analysis revealed the same composition for the inner mold and outer mold, except for the magnetite that was detected in the inner mold alone. As for the main ingredient analysis, the average content of $SiO_2$ was 71.64% and that of $Al_2O_3$ was 14.59%. As for the sub-ingredients, $Fe_2O_3$ was 4.51%, $K_2O$ 3.06%, $Na_2O$, MgO, CaO, $TiO_2$, $P_2O_5$ and MnO was less than 2%.

Comparison of OC and EC Measurement Results Determined by Thermal-optical Analysis Protocols (열광학적 분석 프로토콜에 의한 유기탄소와 원소탄소 측정값 비교)

  • Kim, Hyosun;Jung, Jinsang;Lee, Jinhong;Lee, Sangil
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.5
    • /
    • pp.449-460
    • /
    • 2015
  • Carbonaceous aerosol is generally classified into OC (organic carbon) and EC (elemental carbon) by thermal optical analysis. Both NIOSH (National institute of occupational safety and health) with high temperature (HighT) and IMPROVE-A (Interagency monitoring of protected visual environments) with low temperature (LowT) protocols are widely used. In this study, both protocols were applied for ambient $PM_{2.5}$ samples (Daejeon, Korea) in order to underpin differences in OC and EC measurements. An excellent agreement between NIOSH and IMPROVE-A protocol was observed for TC (total carbon). However, significant differences between OC and EC appeared and the differences were larger for EC than OC. The main differences between two protocols are temperature profile and charring correction method. For the same charring correction method, HighT_OC was 10% higher than LowT_ OC, while HighT_EC was 15% and 33% lower than LowT_EC for TOT (thermal-optical transmittance) and TOR (thermal-optical reflectance), respectively. This difference may be caused by the temperature of OC4 in He step and possibly difference in POC (pryorilized OC) formation. For the same temperature profile, OC by TOT was about 26% higher than that by TOR. In contrast, EC by TOT was about 50% lower than that by TOR. POC was also dependent on both temperature profile and the charring correction method, showing much distinctive differences for the charring correction method (i.e., POC by TOT to POC by TOR ratio is about 2). This difference might be caused by different characteristics between transmittance and reflectance for monitoring POC formation within filters. Results from this study showed that OC and EC depends on applied analysis protocol as shown other studies. Because of the nature of the thermal optical analysis, it may not be possible to have an absolute standard analysis protocol that is applicable for any ambient $PM_{2.5}$. Nevertheless, in order to provide consistent measurement results for scientists and policy makers, future studies should focus on developing a harmonized standard analysis protocol that is suitable for a specific air domain and minimizes variations in OC and EC measurement results. In addition, future elaborate studies are required to find and understand the causes of the differences.

Flowering and Fruiting of Characteristics of Short Flowering Period Lines in Peanut (땅콩 단기개화성 선발 계통의 개화 및 결실 특성)

  • ;Jeom-Ho Ryu
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47 no.6
    • /
    • pp.437-442
    • /
    • 2002
  • To breed high quality and yield peanut variety according to select the short flowering duration, fifteen germplasms (1 virginia,7 spanish,6 valencia types and var, Daekwang) were investigated the flowering habit and agronomic characteristics from 1998 to 1999. Emergence date of the selected short flowering duration germplasms (SPFGs) was earlier 1-3 days and middle or small seed than that of var, Daekwang. Main stem length was longer 57cm but the number of branches, pods, 100-seed weight, and pod weight per plant was reduced 25%, 23%, 42%, 46%, respectively, in SPFCs comparing to var, Daekwang. The flowering date in SPFGs was similar but the flowering duration was earlier 5-16 days than that of var, Daekwang (52 days). Varieties that flowered shorter duration than 50 days were 18.8% among the SPFGs. The number of total flowers in SPFGs was fewer 50% than that of var, Daekwang. The rate of flowering inhibition were 50-52% than that of var Daekwang. The frequencies of flowering duration (under 50 days) were 7.7% in virginia, 46.2% in spanish, 53.9% in valencia. The effect of shading treatment on rate of flowering inhibition were 11%, but number of branches and pods were reduced by 27-31% in valencia type compared to non-shade. Correlation coefficient was significant positively ($r=0.9314^*$ virginia, $r=0.9551^*$ spanish, $r=0.9551^*$ valencia) between the air temperature and flower number, The frequency of peg and pod number on 1st to 2nd nodes in SPFGs were more 3-12%, 21-26% than that of var. Daekwang. The rate of mature pods at 80 days after flowering were higher 12-17% than that of var, Daekwang (68%). Correlation coefficient was high significant negatively between date of first flower and flowering date, the ratio of mature pod.

Reduction of Particulate Matters Levels in Railway Cabins in Korea

  • Park, Duck-Shin;Kwon, Soon-Bark;Cho, Young-Min;Park, Eun-Young;Jeong, Woo-Tae;Lee, Ki-Young
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.1
    • /
    • pp.51-56
    • /
    • 2012
  • Objectives: High concentrations of airborne particulate matters (PM) can affect the health of passengers using public transportation. The objectives of this research were to develop a PM control system for a railway cabin and to evaluate the performance of the device under conditions of an actual journey. Methods: This study measured the concentrations of $PM_{10}$ and $PM_{2.5}$ simultaneously in a reference cabin and a cabin with the PM control device. Results: The average $PM_{10}$ concentration in the reference cabin was 100 ${\mu}g/m^3$, and the $PM_{10}$ concentration in the cabin with the control device was 79 ${\mu}g/m^3$. While the overall control efficiency of the control device was 15.4%, reduction was more effective for peak $PM_{10}$ concentration. However, $PM_{2.5}$ levels did not differ greatly between the reference cabin and the cabin with the control device. The ratio of $PM_{2.5}$ to $PM_{10}$ was 0.37. $PM_{10}$ concentrations in cabins were not associated with ambient concentrations, indicating that the main sources of $PM_{10}$ were present in cabins. Additionally, average $CO_2$ concentration in the cabins was 1,359 ppm, less than the maximum of 2,000 ppm set out by the Korean Ministry of Environment's guideline. The $CO_2$ concentration in cabins was significantly associated with the number of passengers: the in-cabin concentration = $23.4{\times}N+460.2$, where N is the number of passengers. Conclusions: Application of the PM control device can improve $PM_{10}$ concentration, especially at peak levels but not $PM_{2.5}$ concentration.

Surface Flux Measurements at King Sejong Station in West Antarctica: II. Turbulent exchanges of sensible heat and latent heat in the austral summer of 2002-2003 (남극 세종기지에서의 지표 플럭스 관측: II. 2002-2003년 남반구 여름 기간의 열과 수증기의 난류 교환)

  • Choi, Tae-Jin;Lee, Bang-Yong;Lee, Hee-Choon;Kim, Seong-Joong;Hong, Sung-Min
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.3
    • /
    • pp.159-167
    • /
    • 2005
  • Turbulent fluxes of sensible heat and latent heat were analyzed at King Sejong station in the austral summer of 2002 (December) and 2003 (January and February). Monthly mean air temperatures of January and February (2.2oC) were similar to those averaged over 1988 to 2001. Precipitation was less in January and greater in February than those averaged over last 14 years. In December of 2002 and January, there was precipitation primarily when easterly wind blew usually. The frequency of snowfall was equal to or larger than that of rainfall. In the mean while, precipitation primarily in forms of rainfall occurred with westerly wind in February. In addition, while for easterly wind, temperature and humidity was low, temperature and humidity were high in case of westerly wind. Based on flux footprint, measured flux mainly came from within 300 m with maximum of 40 m upwind, indicating the insignificant role of the sea around the study site. Half-hourly downward short wave radiation amounted up to ∼ 1000 Wm-2 and net radiation ranged from -50 to 600 Wm-2. Half-hourly sensible heat flux was positive at daytime with maximum of ∼ 400 Wm-2, except the 27th and 28th in February of 2003 when it was negative all day despite of positive net radiation at short daytime. Latent heat flux was positive with maximum of ∼ 130 Wm-2. Depending on wind direction, the partitioning of net radiation into the sum of sensible heat flux and latent heat flux was larger than 0.8, indicating the strong source of the land surface for the atmospheric heating. The daytime averaged Bowen ratio (=sensible heat flux /latent heat flux) was significantly greater than 1, indicating that sensible heat flux was the main source to heat the atmosphere over the site.

  • PDF

Stabilization Characteristics of the Diffusion Flame Formed in the Wake of Bluff Body with Fuel Injection (연료분출을 수반하는 보염기 후류에 형성되는 확산화염의 보염특성)

  • 안진근
    • Journal of Energy Engineering
    • /
    • v.10 no.3
    • /
    • pp.223-232
    • /
    • 2001
  • To study the stabilization characteristics of diffusion flame formed in the wake of a cylindrical bluff body with fuel injection, the flame stability limits, length and temperature of recirculation zone of flame, turbulence intensity distribution near the recirculation zone of flame were measured and analyzed. The length of recirculation zone is independent on main fuel injection quantity, but it is dependent on fuel injection angles, air stream velocity, and auxiliary fuel injection into recirculation zone. For diffusion flame, in general, the flame stabilization is deteriorated with increase of he length of recirculation zone, but if the turbulence generator is installed, the flame stabilization is improved with increase of the length of recirculation zone. The temperature of recirculation zone is dependent on fuel injection angles, auxiliary fuel injection into recirculation zone, turbulence generators, and it dependent on fuel injection angles, auxiliary fuel injection into recirculation zone, turbulence generators, and it has a maximum value at the condition of each theoretical mixture. In general, the more temperature of recirculation zone is low, the more flame is stable. But when the turbulence generator is installed, the more temperature of recirculation zone is low, the more flame is unstable. The turbulence intensity in the wake of bluff body is increased with increase of diameter or blockage ratio of grid. The more turbulence intensity is increased by installation of turbulence generator, the more flame is unstable. Finally, It is clear that the stabilization characteristics of diffuser flame can be controlled by some parameters such as fuel injection angles, auxiliary fuel injection into recirculation zone, turbulence generators.

  • PDF