• 제목/요약/키워드: Main Air-ratio

검색결과 286건 처리시간 0.032초

Experimental Study on Upstream Fueled Cavity Flame-Holder Scramjet Engine (상류 분사 공동 화염 지지부를 가지는 스크램제트 엔진에 관한 실험적 연구)

  • Jeung, In-Seuck;O'Byrne, Sean;Houwing, A.F.P.;Jeong, Eun-Ju
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제32회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.197-204
    • /
    • 2006
  • The model cavity scramjet engine experiments are carried out using T3 free-piston shock tunnel. Upstream hydrogen fuel is injected before the cavity with different injection pressure. OH planar laser-induced fluorescence is used to investigate the combustion zone and piezoelectric pressure transducers are used to define the pressure rise due to the combustion. Main combustion region is a mixing layer which is between air and fuel. Also high OH fluorescence signal is appeared in the shear layer above the cavity in high equivalence ratio. From the OH signal in the cavity, this fuel injection system can be a role as a flame- holder.

  • PDF

Feasibility Study on the New Structure of a Spindle Motor for Hard Disk Drive

  • Kim, Tae-Woo;Chang, Jung-Hwan
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권3호
    • /
    • pp.295-299
    • /
    • 2013
  • This paper presents the new structure of a spindle motor for hard disk drive (HDD). It can produce axial force as well as torque without a pulling plate or a pulling magnet required for the normal operation of a hydrodynamic bearing in rotating-shaft structure. The proposed models have different air gap length along the axial direction by changing the thickness of permanent magnet (PM). One has a single slope and the other has double slopes on the surface of PM. For the design of the proposed models, variables are defined and its effects on the motor performances are investigated by 3-demensional finite element analysis (FEA). The equi-performance curves are investigated for the main characteristics of the spindle motor such as generated torque, axial force and torque ripple ratio. The validity of the proposed models is verified by the feasibility study and performance evaluation.

Clinical Evaluation of Spontaneous Pneumothorax A Review of 165 cases (자연기흉의 임상적 고찰: 165례)

  • 성후식
    • Journal of Chest Surgery
    • /
    • 제18권4호
    • /
    • pp.582-588
    • /
    • 1985
  • We have observed 165 cases of spontaneous pneumothorax from Aug. 1978 to May. 1985 at the department of Thoracic and Cardiovascular Surgery, School of Medicine, Keimyung University. The ratio of male to female cases were 8.2:1 in male predominance, and the incidence was highest in the adolescence between 21 to 30 year of age. There were 85 patients of primary spontaneous pneumothorax and 80 patients of secondary spontaneous pneumothorax. The etiologic factors of secondary spontaneous pneumothorax were tuberculous origin in 50 cases, chronic bronchitis with emphysematous bullae or blebs in 17 cases, asthma in 10 cases and lung cancer in 3 cases. Closed thoracotomy was performed for reexpansion of collapsed lung in 153 cases, bed rest in 3 cases, needle aspiration in 5 cases and open thoracotomy in 14 cases. Closed thoracotomy was the main therapeutic approach of choice in the great majority of spontaneous pneumothorax with recurrence rate of 21.6%. However, open thoracotomy was undertaken in patients with continuous air leakage, recurrent episodes, bilateral pneumothorax and large visible apical blebs or bullae.

  • PDF

Vibration isolation effect of floor impact sound by ceiling structure (바닥충격음에서의 천장구조에 따른 진동절연 효과)

  • Lee, S.H.;Jeong, G.C.;Chung, J.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.257-260
    • /
    • 2004
  • This study aims to evaluate factors of ceiling structure influencing to the floor impact sound. For this reasons, we measured the vibration of ceiling and the floor impact sound by ceiling structure. The main results from this study are that ceiling structure makes worse to non-ceiling structure for an effect of air layer in heavy-weight floor impact sound. But it has an effect on light-weight floor impact sound about $2\sim8dB$.

  • PDF

Development of a Die Ejector Using Thermopneumatic System (열 공압 방식을 이용한 다이 이젝터의 개발)

  • Jeong Hwan Yun;An Mok Jeong;Hak Jun Lee
    • Journal of the Semiconductor & Display Technology
    • /
    • 제22권3호
    • /
    • pp.1-7
    • /
    • 2023
  • Recently, in the semiconductor industry, memory device market is focusing on producing ultra-thin wafers for high integration. In the wafer manufacturing process, wafers after backgrinding and CMP process must be picked up as individual dies and subjected to be peeled off from the dicing tape. However, ultra-thin dies are vulnerable to the possibility of breakage and failure in their thickness and size. This research studies the mechanism of peeling a die with a high-aspect ratio using a thermopneumatic method instead of a die ejector with physical pins. Setting compressed air and the temperature as main factors, we determine the success of the digester using thermopneumatic system and analyze the good die to find the possibility of making mass-production equipment.

  • PDF

CFD Simulation of Non-reacting and Reacting Flows for a Gas Turbine Combustor Firing Biogas (바이오 가스터빈 연소기의 비반응장과 반응장의 3차원 유동해석)

  • An, Yun-Ho;Nam, Sam-Sik;Choe, Jin-Hoon;Im, Ji-Hyuk;Kim, Ho-Keun;Chun, Jae-Chul
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.439-444
    • /
    • 2011
  • Doosan Heavy Industries & Construction Co., Ltd. has been recently developing the gas turbine engine using the biogas as fuel. This paper describes the non-reacting and reacting flow analysis of the combustor which is one of the main components in gas turbine engine. Through CFD analysis, investigation has been performed to evaluate the primary factors for aerodynamic design and to predict combustor behaviors during operation with various fuel distribution ratios. The calculation results are compared with rig test data, which reveals that CFD predictions such as pressure loss, air distribution ratio, and recirculation flow are quite reliable. The trend of NO formation was similar with the test, except the low fuel distribution ratio.

  • PDF

High-Resolution Numerical Simulations with WRF/Noah-MP in Cheongmicheon Farmland in Korea During the 2014 Special Observation Period (2014년 특별관측 기간 동안 청미천 농경지에서의 WRF/Noah-MP 고해상도 수치모의)

  • Song, Jiae;Lee, Seung-Jae;Kang, Minseok;Moon, Minkyu;Lee, Jung-Hoon;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • 제17권4호
    • /
    • pp.384-398
    • /
    • 2015
  • In this paper, the high-resolution Weather Research and Forecasting/Noah-MultiParameterization (WRF/Noah-MP) modeling system is configured for the Cheongmicheon Farmland site in Korea (CFK), and its performance in land and atmospheric simulation is evaluated using the observed data at CFK during the 2014 special observation period (21 August-10 September). In order to explore the usefulness of turning on Noah-MP dynamic vegetation in midterm simulations of surface and atmospheric variables, two numerical experiments are conducted without dynamic vegetation and with dynamic vegetation (referred to as CTL and DVG experiments, respectively). The main results are as following. 1) CTL showed a tendency of overestimating daytime net shortwave radiation, thereby surface heat fluxes and Bowen ratio. The CTL experiment showed reasonable magnitudes and timing of air temperature at 2 m and 10 m; especially the small error in simulating minimum air temperature showed high potential for predicting frost and leaf wetness duration. The CTL experiment overestimated 10-m wind and precipitation, but the beginning and ending time of precipitation were well captured. 2) When the dynamic vegetation was turned on, the WRF/Noah-MP system showed more realistic values of leaf area index (LAI), net shortwave radiation, surface heat fluxes, Bowen ratio, air temperature, wind and precipitation. The DVG experiment, where LAI is a prognostic variable, produced larger LAI than CTL, and the larger LAI showed better agreement with the observed. The simulated Bowen ratio got closer to the observed ratio, indicating reasonable surface energy partition. The DVG experiment showed patterns similar to CTL, with differences for maximum air temperature. Both experiments showed faster rising of 10-m air temperature during the morning growth hours, presumably due to the rapid growth of daytime mixed layers in the Yonsei University (YSU) boundary layer scheme. The DVG experiment decreased errors in simulating 10-m wind and precipitation. 3) As horizontal resolution increases, the models did not show practical improvement in simulation performance for surface fluxes, air temperature, wind and precipitation, and required three-dimensional observation for more agricultural land spots as well as consistency in model topography and land cover data.

Mean Heat Flux at Gunsan Harbor (군산항의 평균 열속)

  • CHOI Yong-Kyu;JO Young-Jo;CHOI Ok-In;YANG Won-Seok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • 제36권5호
    • /
    • pp.535-540
    • /
    • 2003
  • Based on the monthly weather report of Korea Meteorological Administration (KMA) and daily sea surface temperature (SST) data from National Fisheries Research and Development Institute (NFRDl) (1991-2001), mean heat fluxes were estimated at the Gunsan harbor Net heat flux was transported from the air to the sea surface during March to early September, and it amounts to $125\;Wm^{-2}$ in average daily during May to June. During the middle of September to February, the transfer of net heat flux was conversed from the sea surface to the air with $-125\;Wm^{-2}$ in mininum value in October. Short wave radiation was ranged from 50 to $248\;Wm^{-2}$ showing maxima in April to June. Long wave radiation was ranged from 25 to $92\;Wm^{-2}$ with mininum value in June to July. Sensible heat flux denoting negative values in April to August was ranged from -30 to $72\;Wm^{-2}.$ Latent heat flux was ranged from 15 to $82\;Wm^{-2}$ with maxima in August to September. The phase of heat exchange was changed from cooling to heating in the end of February, and from heating to cooling In the beginning of September. The advective term of heat flux showed minima in April to June and maxima in November. The ratio of temperature variations was 1.37 in the sea surface process and the horizontal process by advection. This indicates that the main factor in variation of temperature at Gunsan harbor is the heat exchange process through the sea surface from the air.

Foreign bodies in air passage in Children (소아의 기도이물에 관한 통계적 관찰)

  • 유장열;오경균;백만기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 대한기관식도과학회 1977년도 제11차 학술대회연제 순서 및 초록
    • /
    • pp.8.5-9
    • /
    • 1977
  • Foreign bodies in food and air passage, especially the latter in infants and children requires emergency treatment. The frequent symptoms are coughing, wheezing, and dyspnea, So may be confused as asthma, pneumonia and acute Laryngitis. The species and incidence of the foregin bodies are variable according to the age, method of life, environment and economic condition. The authors experienced 35 cases of foreign body in air passage during the period of last 3yrs which were treated by ventilating Bronchoscopy, and thoractomy in this hospital. One of them was lead to death. The authors analysed above cases and report with it's literature consideration. Results: 1. The prevalent foreign bodies were peanut, metal, food particles in order of frequency. 2. In frequent symptoms were dyspnea, coughing and wheezing in the order. 3. In the age incidence, 48% of the foreign bodies were 1∼5yrs. 4. In sex distribution, male to female ratio was 2.1: 1 5. In duration of lodgment, 65% of the foreign body were removed within 24hrs. 6. Most prevalent site of the foreign body was Rt. main bronchus Rt. to Lt. ratis was 2 : 1 was 7. Treatment was done; 25 cases were by ventilating bronchoscopy.

  • PDF

An Operation Status Analysis of Library Building using BEMS Data; Energy Performance Evaluation on Initial Stage of Completion (BEMS 데이터를 활용한 도서관 건물의 운전현황 분석 -준공 초기단계의 건물 에너지 성능 평가)

  • Park, Seong-cheol;Ha, Ju-wan;Kim, Hwan-yong;Song, Young-hak
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • 제12권6호
    • /
    • pp.669-679
    • /
    • 2018
  • Energy consumption savings in buildings should be reviewed in diverse areas such as air conditioning system and lighting responsible for cooling and heating, and energy management systems such as BAS (Building Automation System) and BEMS (Building Energy Management System) are introduced to improve energy consumption efficiency and to promote economic control of related facilities by integrated management of energy generated and consumption in buildings. The measured building of this study uses regenerative geothermal system. Measured values of heat pump and system COP were 4.7 and 4.2 respectively, and they were found to be higher 11.9% and 23.5% than rated values. As a result of analyzing the air conditioning and lighting energy from the first floor to the fourth floor performing the air conditioning, the second and third floors, which have a high frequency of use, are compared with the first and fourth floors 50% higher energy consumption ratio. On the other hand, the general heat storage system uses the nighttime power of the previous day to store heat and use it the next day. The total number of days of abnormal operation during the summer season is 61 days. The electricity cost corresponding to the abnormal operation is 1,840,641 KRW, and the normal operation using the nighttime power is 1,363,561 KRW, which is difference of 477,080 KRW, 35% increase in cost. We will utilize it as the main data of BEMS through analysis of winter operation characteristics as well as summer operation characteristics.