• Title/Summary/Keyword: Main/Standby control

Search Result 17, Processing Time 0.044 seconds

Development of Generator Excitation System with Main/Standby Controller in In-chun Thermal power plant #4 (인천화력 4호기 발전기용 주/부 제어기를 갖는 정지형 여자시스템 개발)

  • 류호선;임익헌
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.407-410
    • /
    • 1999
  • Potential-source controlled excitation system had been developed for synchronous generator in In-Chun thermal power plant #4 by KEPRI. This paper describes the characteristics of Main/Standby control system employed analog, digital circuit devices (hybrid type) and 3 PCRs(Phase Controlled Rectifier)

  • PDF

Cost-effective Power System with an Electronic Double Layer Capacitor for Reducing the Standby Power Consumption of Consumer Electronic Devices

  • Park, Kyung-Hwa;Yi, Kang-Hyun
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.362-368
    • /
    • 2013
  • Commercial home appliances using remotely controlled systems consume electric power while in standby mode to prepare for receiving a remote turn-on signal. The proposed power system can significantly reduce standby power consumption without increasing cost. Furthermore, since a Electronic Double Layer Capacitor (EDLC) is used as an auxiliary power storage element, the life cycle is longer and system reliability can be better than with existing approaches. When the energy of the EDLC is not sufficient for turning on the appliance, the power system charges the EDLC without affecting the main system. The proposed power system is verified with a commercial LCD TV and a 3.93mW standby consumption is obtained. This standby consumption can be regarded as zero standby equipment according to the IEC-62031 standard.

An active system for unnecessary noise reduction in kitchen range hoods

  • Kim, Eunhee;Jang, Jaechun;Lim, Changmok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.3
    • /
    • pp.91-96
    • /
    • 2016
  • We have surrounded undesired living noises in our life. One of biggest noises coming out of range hood during cooking in the kitchen. A range hood is one of the most important appliances in the kitchen because it ventilates polluted air out during cooking, and maintains air quality in the kitchen. But current kitchen range hoods bring up some issues; First, the range hoods consume massive amount of standby power not in use condition. Second, current models have designed manual fan operating system with sudden onset of noise with starting. In this paper, we propose an auto control system entire processes from air ventilation to noise reduction. Our system is consist of three parts (Eco-sensors pack, Main Controller and Active Noise Controller); Eco-sensors pack detects air pollution of kitchen areas and sends the detection values to Main Controller. Main Controller determines operation of range hood by detected values. Active Noise Controller is located inside of the range hood. It received starting signals from Main Controller which elicits degrees of polluted air condition and fan operating speed from 1 to 3. Once Active Noise Controller detected the signals, it runs a ventilating fan until new value from Main Controller becomes 0. while the range hood works, A noise cancellation algorithm inside of Active Noise Controller become activated to reduce levels of noise. As a result, the proposed system clearly shows reduction in power consumption include standby power and decreases in levels of noise.

Paper Duplication Method Supported by Task (태스크 기반 이중화 방안)

  • Lee, Jong-Chan;Park, Sang-Joon;Kang, Kwon-Il
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.1C
    • /
    • pp.103-111
    • /
    • 2002
  • In RNC of IMT-2000, main control processors such as ASP, ACP and OMP are responsible for call control function, and the high reliability and real-time property should be provided for it. So, the study of real-time fault-tolerant for it is needed. In this paper, we proposes an Task based duplication method, in which Tasks in active side operated on message unit and send the updated data to standby side after operation, log in the message to standby side for recovery during take-over. This scheme decreases the dual down and the complexity of synchronization procedure, and performs the synchronization more exactly because Tasks control the synchronization of system. This paper also proposes the fault detection and the fault handing method for effective implementation of Task based duplication. This scheme focus on increasing the fault detection rate and intercepting originally that fault data is send to standby side.

Redundant Architectural Design of Hydraulic Control System for Reliability Improvement of Underwater Construction Robot (수중건설로봇의 유압 제어 안정성 향상을 위한 이중화 설계)

  • Lee, Jung-Woo;Park, Jeong-Woo;Suh, Jin-Ho;Choi, Young-Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.380-385
    • /
    • 2015
  • In the development of an underwater construction robot, the reliability of the operating system is the most important issue because of its huge maintenance cost, especially in a deep sea application. In this paper, we propose a new redundant architectural design for the hydraulic control system of an underwater construction robot. The proposed architecture consists of dual independent modular redundancy management systems linked with a commercial profibus network. A cold standby redundancy management system consisting of a preprocessing switch circuit is applied to the signal network, and a hot standby redundancy management system is adapted to utilize two main controllers.

A Study on Standby Power and Reduced Power Consumption Control System for High-efficiency Module (대기전력 및 소비전력 절감을 위한 고효율 모듈제어 시스템에 관한 연구)

  • Lee, Myung-Hwan;Park, Yung-Teak;Chung, Hun-Suk;Kang, Ey-Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.5
    • /
    • pp.334-339
    • /
    • 2012
  • A study on electrical and electronic equipment will occur in the atmosphere, which is essential to cut the power to prevent the waste of power by power measurement technology development and to develop the technology to do this operation is the main core of standby power to detect and block it and return the configured for software and hardware, while the actual construction to ensure stability through field testing and debugging of problems improved accordingly, as well as ease of installation and so it could be done while the test. In addition, in terms of basic hardware switching of standby power when blocking, reducing stress and ensure stable operation and circuit design, power off and back to ensure stable operation even when a protection circuit is applied.

Method and implementation for reducing standby power consumption in intermediate capacity power supply with Power Line Communication (전력선통신기능 적용 중.대용량 전원공급장치의 대기전력 절감방법 및 구현)

  • Son, Do-Sun;Kim, Ki-Hyun;Kim, Sang-Cheol;Jeon, Eui-Seok;Lee, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1947-1948
    • /
    • 2008
  • This paper presents the implementation of Power Line Communication(PLC) module which can reduce standby-power consumption. The suggested PLC module consists of PLC modem, coupling circuit, ZCP(Zero-Cross Point) Circuit and main SMPS control relay. The test results under power line communication test-bed used home appliance show the 77% saving of standby-power.

  • PDF

Stable Standby-mode Implementation of Multi-output Power Supply using a New Load Current Estimation Technique with Linear Regulator (다중 출력 전원공급장치의 안정적 대기전력 구현을 위한 새로운 방식의 부하전류 측정기법 구현)

  • Lee, Jong-Hyun;Jung, An-Yeol;Kim, Dong-Joon;Park, Joung-Hu;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.88-95
    • /
    • 2011
  • In this paper, a new standby-mode control method for multiple output switching-mode power-supply is suggested, which uses the control signal of the feedback compensator of the inner loop in the linear voltage regulator located at the transformer secondary side, as the load current information. Conventional method has a problem that standby mode occurs depending only on the load condition of the main controller output, which makes the other secondary side output very inaccurate by burst mode operation. The proposed method detects all the load current information and operates in burst mode only when the all of them are light load condition. Minimum of the additional components are required for the implementation of the proposed method because the load information is obtained from the existing feedback circuit of the post-stage linear regulator. In this paper, the operating principles of the proposed standby-mode circuit are presented with an numerical analysis, and are verified by 25W hardware prototype implementation.

Development of generator excitation system with main/standby controller in Inchun thermal power plant #4 (인천화력 4호기 발전기용 주/부 제어기를 갖는 정지형 여자시스템 개발)

  • 류호선;김수열;김장목;임익헌
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.507-514
    • /
    • 1999
  • 한국전력에서는 인천화력 4호기 수명연장의 일환으로 여자시스템 교체가 이루어졌다. 기존의 회전형 여자 시스템은 발전기축에 부여자기와 교류여자기가 부착되어 회전하는 형태로 과거 스위칭소자 용량의 한계를 극복하기 위하여 설계된 시스템으로 전력연구원에는 회전형 여자시스템을 새롭게 개발된 아날로그와 디지털의 하이브리드 제어기와 대용량 사이리스터 제어정류기를 가지고 잇는 정지형 이중화 여자시스템으로 교체하였다. 설비의 신뢰성을 높이기 위하여 정지형 여자시스템의 상태를 순시 감시하기 위한 데이터 취득 시스템이 설치 되었고 위상제어정류기는 운전시 1대가 고장이 발생하더라도 발전기의 전부하 능력을 유지하기 위하여 3대가 병렬로 운전되는 N+1 방식을 채택하였다. 시스템의 신뢰성 시험은 성능평가를 위한 시운전시에 검증되었으며 성공적으로 운전중에 있다.

  • PDF

Design and Implementation of Standby Power Cutoff System for Smart Home Environment Based on Zigbee-MQTT (Zigbee-MQTT 기반 스마트 홈 환경에 적합한 대기전력 차단 시스템 설계 및 구현)

  • Jang, Young-Hwan;Yang, Seung-Su;Park, Seok-Cheon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.4
    • /
    • pp.129-135
    • /
    • 2017
  • Recently, with the development of IoT technology, there has been an increase in interest in the power consumption of the devices used by the internal devices. Especially, the standby power consumption during the main function of the devices is about 11% of the power energy and the problem of standby power interruption is suggested. However, there is a problem that the plug must be unplugged in order to substantially shut off standby power. Therefore, in this paper, we design and implement a standby power cutoff algorithm that can automatically control and manage users' participation in order to solve there problems. As a result of evaluating the implemented system, it was confirmed that the standby power interruption rate improved by about 5.89Wh on average compared to the existing system.