• 제목/요약/키워드: Magnitude factor

검색결과 545건 처리시간 0.022초

Damping modification factor of pseudo-acceleration spectrum considering influences of magnitude, distance and site conditions

  • Haizhong Zhang;Jia Deng;Yan-Gang Zhao
    • Earthquakes and Structures
    • /
    • 제25권5호
    • /
    • pp.325-342
    • /
    • 2023
  • The damping modification factor (DMF) is used to modify the 5%-damped response spectrum to produce spectral values that correspond to other necessary damping ratios for seismic design. The DMF has been the subject of numerous studies, and it has been discovered that seismological parameters like magnitude and distance can have an impact on it. However, DMF formulations incorporating these seismological parameters cannot be directly applied to seismic design because these parameters are not specified in the present seismic codes. The goal of this study is to develop a formulation for the DMF that can be directly applied in seismic design and that takes the effects of magnitude, distance, and site conditions into account. To achieve this goal, 16660 ground motions with magnitudes ranging from 4 to 9 and epicentral distances ranging from 10 to 200 km are used to systematically study the effects of magnitude, distance, and site conditions on the DMF. Furthermore, according to the knowledge that magnitude and distance affect the DMF primarily by changing the spectral shape, a spectral shape factor is adopted to reflect influences of magnitude and distance, and a new formulation for the DMF incorporating the spectral shape factor is developed. In comparison to the current formulations, the proposed formulation provides a more accurate prediction of the DMF and can be employed directly in seismic design.

A Novel Detection Algorithm for Instantaneous Voltage Sag Corrector Using Series Compensator

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.502-507
    • /
    • 2001
  • This paper proposes a novel detection algorithm of faulted voltages under the unbalanced condition. To quantify the standard of unbalance under the faulted conditions, the 3-phase unbalanced voltages are decomposed into two balanced 3-phase symmetrical components of the positive and negative sequence voltages, which is defined by the magnitude factor (MF) and unbalance factor (MF). It is analyzed that MF and UF values are given as the dc constant values even though unbalance condition. This paper also proposes the control scheme of the instantaneous voltage sag corrector based on this detection algorithm. The validity of the proposed algorithm is verified through the EMTDC simulation and experiments.

  • PDF

Voltage Sag Detection Algorithm for Instantaneous Voltage Sag Corrector

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • Journal of Power Electronics
    • /
    • 제2권3호
    • /
    • pp.162-170
    • /
    • 2002
  • Voltage sag detection algorithm for voltage sag corrector is proposed in this paper. To quantify the standard of voltage unbalance under the faulted conditions, the 3-phase unbalanced voltages are decomposed into two balanced 3-phase symmetrical components of the positive and negative sequence voltages, which is defined by the magnitude factor (MF) and unbalance factor (UF). It is analyzed that MWF and UF values are given as the dc constant values even though under the voltage unbalance condition. This paper also proposes the control scheme of the instantaneous voltage sag corrector based on this detection algorithm. The validity of the proposed algorithm is verified through the EMTDC simulation and experiments.

세척과 절연보강에 따른 고압전동기 고정자 권선의 절연상태 분석 (Analysis of Insulation Condition in High Voltage Motor Stator Windings Following Cleaning and Insulation Reinforcement)

  • 김희동
    • 한국전기전자재료학회논문지
    • /
    • 제25권6호
    • /
    • pp.474-480
    • /
    • 2012
  • Diagnostic tests were performed on two high voltage(HV) motor stator windings. These tests included the measurement of insulation resistance, polarization index, AC current, dissipation factor($tan{\delta}$) and partial discharge(PD) magnitude. Surface contamination of HV motor stator windings has an effect on the AC current and $tan{\delta}$. When the stator windings were finished cleaning and insulation reinforcement, the increase rate of AC current(${\Delta}I$) and dissipation factor(${\Delta}tan{\delta}$) were very small compared to those before cleaning. However, the PD magnitude remained the same. These tests show that cleaning and insulation reinforcement of HV motor stator windings can reduce the insulation failure.

Analysis of Insulation Quality in Large Generator Stator Windings

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho;Kim, Byong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권3호
    • /
    • pp.384-390
    • /
    • 2011
  • To evaluate the condition of stator winding insulation in generators that have been operated for a long period of time, diagnostic tests were performed on the stator bars of a 500 MW, 22 kV generator under accelerated thermal and electrical aging procedures. The tests included measurements of AC current (${\Delta}I$), dissipation factor ($tan{\delta}$), partial discharge (PD) magnitude, and capacitance (C). In addition, the AC current test was performed on the stator winding of a 350 MW, 24 kV generator under operation to confirm insulation deterioration. The values of ${\Delta}I$, ${\Delta}tan{\delta}$, and PD magnitude in one stator bar indicated serious insulation deterioration. In another stator bar, the ${\Delta}I$ measurements showed that the insulation was in good condition, whereas the values of ${\Delta}tan{\delta}$ and PD magnitude indicated an incipient stage of insulation deterioration. Measurements of ${\Delta}I$ and PD magnitude in all three phases (A, B, C) of the remaining generator stator windings showed that they were in good condition, although the ${\Delta}tan{\delta}$ measurements suggested that the condition of the insulation should be monitored carefully. Overall analysis of the results suggested that the generator stator windings were in good condition. The patterns of PD magnitude in all three phases (A, B, C) were attributed to internal discharge.

유방암의 위험요인 (Risk Factors of Breast Cancer)

  • 정복례;변혜선;김경덕;김경혜
    • 종양간호연구
    • /
    • 제8권2호
    • /
    • pp.120-127
    • /
    • 2008
  • Purpose: The purpose of this study was secondary analysis to explore about risk factors with breast cancer on a basis of primary literature. Methods: This study was searched articles by using CINAHL, MEDLINE, Riss4u, Internet website regarding breast cancer. This study searched for the journal published in Korea and foreign countries from 2000 to 2008, about risk factors of breast cancer. This study was reviewed 42 articles (5 experimental study, 35 survey, 1 qualitative study, 1 report) suitable for the research objectives. Results: Magnitude of risk breast cancer (++) was age, geographic region, family history, mutations in BRCA1, BRCA2 genes and in other penetrance genes, radiation, history of benign breast disease, late age of menopause, early age of menarch, nulliparity and older age at first birth, high mammographic breast density, high insulin-like growth factor 1 level. Magnitude of risk factor (+) was hormone replacement therapy, oral contraceptives use, obesity, tall stature, alcohol consumption, high prolactin level, high saturated fat and well-done meat intake, polymorphisms in low penetrance gene, high socioeconomic status. Conclusion: A breast cancer screening protocol according to magnitude of risk factors is needed for disease prevention. The nurses need to educate and counsel women with risk factors of breast cancer.

  • PDF

Bearing capacity factor Nγ for a rough conical footing

  • Khatri, Vishwas N.;Kumar, Jyant
    • Geomechanics and Engineering
    • /
    • 제1권3호
    • /
    • pp.205-218
    • /
    • 2009
  • The bearing capacity factor $N_{\gamma}$ is computed for a rough conical footing placed over horizontal ground surface. The axisymmetric lower bound limit analysis formulation, in combination with finite elements and linear programming, proposed recently by the authors is used in this study. The variation of $N_{\gamma}$ with cone apex angle (${\beta}$), in a range of $30^{\circ}-180^{\circ}$, is obtained for different values of ${\phi}$; where ${\phi}$ is soil friction angle. For ${\phi}<30^{\circ}$, the magnitude of $N_{\gamma}$ is found to decrease continuously with an increase in ${\beta}$ from $30^{\circ}$ to $180^{\circ}$. On the other hand, for ${\phi}>30^{\circ}$, the minimum magnitude of $N_{\gamma}$ is found to occur generally between ${\beta}=120^{\circ}$ and ${\beta}=150^{\circ}$. In all the cases, it is noticed that the magnitude of $N_{\gamma}$ becomes maximum for ${\beta}=30^{\circ}$. For a given diameter of the cone, the area of the plastic zone reduces generally with an increase in ${\beta}$. The obtained values of $N_{\gamma}$ are found to compare quite well with those available in literature.

손상곡선에 의한 구조물의 거동파악 (The Response of the Structure with the Damage Curve)

  • 이상호;송현섭
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제9권1호
    • /
    • pp.189-196
    • /
    • 2005
  • 임펄스 비와 하중최대치의 비로 작성된 손상곡선을 이용하여 충격하중의 임펄스와 하중의 크기가 구조물의 거동에 미치는 영향을 분석하였다. 단기에 종료하는 충격하중의 경우 관성력의 영향으로 하중의 크기보다는 임펄스가 구조물 손상에 주요변수가 되며, 관성력을 극복할 충분한 시간을 갖는 장기하중이 작용하는 경우에는 임펄스보다는 하중의 크기가 구조물 손상에 주요변수가 된다. 지반충격에 의한 구조물의 손상은 단기인 경우에는 지반의 최대입자속도가 그러나 장기인 경우에는 최대입자가속도가 손상의 주요 변수가 된다.

INFLUENCE FACTOR-BASED RISK ASSESSMENT METHODOLOGY FOR CONSTRUCITON

  • Hyunsoo Kim;Hyunsoo Lee;Moonseo Park;Kwang-pyo Lee
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.1231-1236
    • /
    • 2009
  • Many work-related risk factors can cause construction site hazards. Therefore, safety management begins with measuring the magnitude of risk involved in a project. This study proposes a methodology for risk assessment of major trades at a particular construction site. To assess risk, this methodology integrates hazard severity and frequency, and their magnitude is calculated based on actual work-site hazards. This methodology also considers the influence factors that affect the frequency of work-related hazards. To select the appropriate influence factors, a two step approach is deployed. First, the predominant factors are identified through a literature review. Second, a selective process filters out the influence factors that are difficult to analyze quantitatively, and these extracted factors are weighted using expert surveys. Finally, the factors are combined and a quantitative risk assessment methodology is proposed.

  • PDF

Magnitude Estimation기법을 이용한 설계대안의 평가 (Evaluating design alternatives based on magnitude estimation)

  • 한성호;정의승;정무영;박성준;곽지영;최필성
    • 대한인간공학회지
    • /
    • 제12권2호
    • /
    • pp.3-13
    • /
    • 1993
  • A psychophysical measurement technique called "magnitude estimation" was used to evaluate several interior design alternatives for a high speed train. Pas- senger activity, seat direction, and passenger age were manipulated by using a three factor within-subjects experimental design. During the experiment, two dependent measures, a line length and a numerical estimate for each alternative design were collected to validate the experimental procedures. The results showed that pasnger seats arranged in the same direction as the running direction of the train was favored nine times more than the opposite. Also, the subjects preferred listening to music in a coach train to the other activities such as reading newspaper, watching a movie, and resting. This paper demonstrates that a psychophysical technique can be sued in the design of a development process, especially when it is difficult to quantify design variables such as subjective opinion or preference, etc.

  • PDF