• 제목/요약/키워드: Magnification of image

검색결과 190건 처리시간 0.028초

디지털 치근단방사선영상에 관한 시각 특성 연구 (A Study on the Visual System of the Digital Periapical Images)

  • 최은숙;고광준
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.261-274
    • /
    • 1999
  • Objectives: The purpose of this study was to evaluate the optimal distance and angle of observers by modulation transfer functions(MTFs) and receiver operating characteristics(ROCs), Material and Methods: Digital periapical radiograms were taken from 43 patients who have dental diseases(19 patients : dental caries. 12 patients : periapical lesions, 12 patients : periodontal diseases). Segmental images(4×4cm) were evaluated by 4 MTFs and ROC analysis. Results: The optimal distance(magnification) using MTF by Mannos & Sakrison was 12.97. and those by Nill. Ngan and Rao were 8.39, 4.78. 5.84 respectively. The optimal distance obtained from 4 radiologists by ROC analysis was 32cm(Az value: 0.89). and it was 40cm(Az value: 0.78) from 4 non-radiologists. There were significant differences of Az values between 4 radiologists and 4 non-radiologists at 24. 32 and 40cm (P<0.05). No significant differences of optimal distances were observed using 4 MTFs among +20, +10, 0, -10, -20 degrees(P>0.05). The optimal angle obtained from 4 radiologists by ROC analysis was +20 degree(Az value: 0.91). and no significant differences of Az values were observed among +20, +10, 0, -10 and -20 degrees(P>0.05). The optimal angle obtained from 4 non-radiologists by ROC analysis was 0 degree(Az value : 0.81). and no significant differences of Az values were observed among +20, +10, 0, -10 and -20 degrees(P>0.05). And there was significant difference of Az value between 4 radiologists and 4 non-radiologists at +20 degree(P<0.05). but no significant differences of Az values were observed among +10, 0, -10 and -20 degrees(P>0.05).

  • PDF

광학 현미경을 이용한 선표준물 측정 시스템 개발 (Development of Line Standards Measurement System Using an Optical Microscope)

  • 김종안;김재완;강주석;엄태봉
    • 한국정밀공학회지
    • /
    • 제26권8호
    • /
    • pp.72-78
    • /
    • 2009
  • We developed a line standards measurement system using an optical microscope and measured two kinds of line standards. It consists of three main parts: an optical microscope module including a CCD camera, a stage system with a linear encoder, and a measurement program for a microscopic image processing. The magnification of microscope part was calibrated using one-dimensional gratings and the angular motion of stage was measured to estimate the Abbe error. The threshold level in line width measurement was determined by comparing with certified values of a line width reference specimen, and its validity was proved through the measurement of another line width specimen. The expanded uncertainty (k=2) was about 100 nm in the measurements of $1{\mu}m{\sim}10{\mu}m$ line width. In the comparison results of line spacing measurement, two kinds of values were coincide within the expanded uncertainty, which were obtained by the one-dimensional measuring machine in KRISS and the line standards measurement system. The expanded uncertainty (k=2) in the line spacing measurement was estimated as $\sqrt{(0.098{\mu}m)^2+(1.8{\times}10^{-4}{\times}L)^2}$. Therefore, it will be applied effectively to the calibration of line standards, such as line width and line spacing, with the expanded uncertainty of several hundreds nanometer.

측방가압법과 System BTM를 이용한 근관충전시 근관만곡도에 따른 폐쇄효과의 비교 (COMPARISON OF THE INFLUENCE OF CANAL CURVATURE ON THE SEALING ABILITY OF LATERAL CONDENSATION AND SYSTEM BTM)

  • 임동열;이희주;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제24권3호
    • /
    • pp.482-489
    • /
    • 1999
  • The purpose of this study was to compare sealing ability between lateral condensation and continuous wave of condensation in depend of root canal curvature. In this study, we divided fifty-six human molar teeth into two group in depend of Schneider method, and then subdivided them into four experimental group (each group is composed of twelve teeth) by canal curvature and obturation method, and eight teeth were served as positive and negative controls. Specimens were prepared by Quantac 2000 series file and obturated by lateral condensation or System B. Specimens were immersed in india ink for 7 days, decalcified by 10% nitric acid, dehydrated by 75, 95 and 100% alcohol in order, cleared by methyl salicylate and then measured of dye penetration with stereomicroscope(${\times}6.5$ magnification) and Image Pro plus. The data were analyzed stastically by one-way ANOVA and Scheffe test. The data were as follows: 1. The mean leakage was $0.725{\pm}1.167$ for group A, $0.813{\pm}0.921$ for group B, $0.809{\pm}0.997$ for group C, $1.111{\pm}1.147$ for group D, but no significant difference among them(p>0.05). 2. Lateral condensation had better sealing ability than continuous wave of condensation, but no significant difference among them(p>0.05). 3. There was no significant difference between root canal curvature degree and microleakage(p>0.05).

  • PDF

무선 WiGig 전송 연구 (Generation of Forensic Evidence Data from Script)

  • 최상현;박대우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 추계학술대회
    • /
    • pp.356-359
    • /
    • 2017
  • 교육부의 운영계획에 따라서 학교당 1~2개 교실에 전자칠판(IWB, Interactive White Board)이 보급되었다. 따라서, 두상투영기(OHP, Overhead Projector)와 스크린 대신에 실물화상기와 전자칠판이 그 역할을 대신하게 되었다. 하지만 촬상소자와 디스플레이 장치의 발전 속도를 따라가지 못하고, 활용도가 떨어지는 경우가 많았다. 본 연구에서는 스마트폰의 카메라를 이용하여 고해상도의 이미지를 획득할 수 있도록 연구한다. 획득한 고해상도의 이미지를 전자칠판이나 대형 TV로 무선 통신으로 지연시간 없이 전송할 수 있도록 와이기그(WiGig, Wireless Gigabit) 기술을 이용한다. 또한 스마트폰 카메라에 넓은 화각(FOV, Field of View)의 렌즈를 탑재하여 출시하는 것에 반하여, 현미경 렌즈를 이용하여 스마트폰으로 특정 부분을 400배까지 확대하여 관찰할 수 있도록 한다. 본 연구결과로 교육 및 연구 현장에서 실시간 400배 확대의 활성화 자료로서 사용될 것이다.

  • PDF

시멘트 공간이 캐드캠 시스템으로 제작한 지르코니아 수복물의 변연과 내부 적합도에 미치는 효과 (Effect of cement space on the marginal and internal fit of zirconia restorations fabricated by CAD/CAM system)

  • 이정환;안재석
    • 대한치과기공학회지
    • /
    • 제39권4호
    • /
    • pp.235-242
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate the marginal and internal gap of zirconia copings fabricated by CAD/CAM system and to research the effect of cement space on the fit of zirconia prosthesis. Methods: Zirconia copings were designed using 3shape software and then milled from presintered zirconia blocks by Kavo dental milling machine. The cement space was set at $0{\mu}m$ around the margins for all groups, and additional cement space appling 1 mm above the finish lines of tooth. The samples were classified into 4 groups according to the cement space setting(Cs-0, Cs-40, Cs-80, Cs-120). Replica technique used to investigate marginal and internal gap. The silicone film thickness was recorded using a optical microscope with image software analysis system at 75${\times}$magnification. The assessment performed on the six points in bucco-lingual and mesio-distal sections(4 groups, 10 copings per group, 12 measuring points per coping). The data were statistically analyzed with one-way ANOVA followed by pair-wise Tukey's post hoc tests(${\alpha}$<0.05). Results: Better marginal and internal fit values were exhibited by $80{\mu}m$ cement space. The results showed that different cement space values had statistically significant effect on the marginal and internal gap of zirconia copings(p<0.001). The gap of margin and axial wall area was smaller than that the gap of occlusal area in all groups(p<0.001). Conclusion : Effect of different cement spaces on the marginal and internal gap of zirconia copings.

Easy Filling 및 Quick Obturation System을 이용한 열연화 충전법의 치근단 밀폐도 평가 (A COMPARISON OF THE APICAL SEAL PRODUCED BY EASY FILLING SYSTEM AND QUICK OBTURATION SYSTEM)

  • 신정인;금기연;이승종
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.202-211
    • /
    • 2000
  • The aim of this study was to compare the apical sealing ability of a new thermoplasticized gutta-percha filling technique, the Easy Filling and the Quick Obturation system with lateral condensation technique and Thermafil system to evaluate their clinical acceptabilities. Fifty-two extracted single-rooted teeth were instrumented to #35 using the .04 taper ProFile system. Four groups of 12 teeth were obturated by lateral condensation technique. Thermafil system and two new thermoplasticized gutta-percha techniques, the Easy Filling system and Quick Obturation system (Meta Dental co. Ltd. Korea), respectively. Four teeth served as controls. After the teeth were immersed in 2% methylene blue dye for 48 hours, they were resected horizontally at 1mm to 5mm level from the anatomical apex using a low-speed microtome. Each section was examined under a stereomicroscope at ${\times40}$ magnification and photographed. After each image was scanned, the leakage area was measured at each level using Brain 3 (Nosdia Tech., Korea) software. Leakage ratio was calculated for each group and was analyzed statistically to come up with the following results: 1. At 1mm level, the Quick Obturation system had the largest amount of apical leakage and it was statistically significant when compared with the lateral condensation group and the Thermafil group (p<0.05). 2. At 2mm and 3mm level, there were no significant difference of apical leakage among all four groups (p>0.05), and from 4mm level, no apical dye penetration was observed in all the groups. In conclusion, the apical seal produced by Easy Filling system and the Quick Obturation system was comparable to lateral condensation technique and Thermafil system except for the 1mm level. More improvement of the apical seal can be expected as the operator becomes skillful with the new techniques.

  • PDF

세척 방법 및 세척 시간에 따른 3D 프린팅 방식으로 제작된 임시 보철물의 변연 및 내면 적합도 평가 (Evaluation of Marginal and Internal Gap of Temporary Prosthesis Fabricated by 3D Printing Method According to Rinsing Method and Rinsing Time)

  • 배지현;최재원
    • 한국산업융합학회 논문집
    • /
    • 제26권4_2호
    • /
    • pp.561-570
    • /
    • 2023
  • This study was to evaluate the effect of different rinsing times and methods on the accuracy of temporary prostheses fabricated by 3D printing method. Sixty temporary prostheses were fabricated with LCD types of 3D printer(Halot-Sky, Creality, Shenzhen, China) and divided into six groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5 and 10 min using three methods-hand washed, ultrasonic cleaning, and automated washing. All specimens were polymerized for 3 minutes under the same conditions. The marginal and internal gaps of specimens were examined using a replica technique. The light-body silicone thickness was measured at 6 reference points(Absolute marginal discrepancy, Marginal, Chamfer, Axial, Angle, and Occlusal gap). All measurements were performed by a stereomicroscope. Reference point images were taken at 100× magnification and then measured using an image analysis program. Statistical analysis was performed using Two-way ANOVA, One-way ANOVA, and the Kruskal-Wallis test (p = .05). The marginal and internal gaps were statistically different according to the rinsing methods and rinsing times(p < .001). In the rinsing time, the temporary prosthesis rinsed for 5 minutes group showed higher accuracy than 10 minutes group. In the rinsing method, the hand washing group showed higher accuracy than the automated washing group.

Doublet 반사경을 이용한 도트 사이트 장치의 개발 (Development of the Dot Sight Device by Using the Doublet Reflector)

  • 이동희
    • 한국안광학회지
    • /
    • 제13권1호
    • /
    • pp.65-69
    • /
    • 2008
  • 목적: Doublet 반사경을 이용한 조준사격용 도트 사이트 장치의 개발. 방법: Sigma 2000 광학 설계 프로그램으로 Singlet 반사경과 Doublet 반사경을 설계하여 비교 검토하였다. 결과: 유한광선수차 분석에서 기존 Singlet 반사경을 사용한 도트 사이트 장치에 비해 시차(parallax)가 제거된 유효 시야가 3.3배 확대되는 성능을 보인다. Doublet 반사경을 사용하는 경우 광학계의 중심 두께가 기존 Singlet 반사경을 사용한 경우보다 2배 이상 두꺼워지기 때문에 목표점이 관측자의 망막에 결상할 때 Singlet 반사경의 경우와 같이 제1면과 제3면의 곡률반경을 동일하게 할 경우에는 배율 변화가 나타난다. 이를 극복하기 위해 Doublet 반사경인 경우에는 어포칼 조건을 만족하는 것이 필요하다. 결론: 기존의 Singlet 반사경의 방식보다 시차(parallax)가 제거된 유효 시야가 3.3배 확대되는 성능을 가지는 Doublet 반사경을 이용한 조준사격용 도트 사이트 장치를 개발하였다.

  • PDF

Study on the Surface Magnetic Domain Structure of Thin-Gauged 3% Si-Fe Strips using Scanning Electron Microscopy with Polarization Analysis

  • Chai, K.H.;Heo, N.-H.;Na, J.g.;Lee, S.R.;Woo, j.s.
    • Journal of Magnetics
    • /
    • 제3권2호
    • /
    • pp.44-48
    • /
    • 1998
  • Scanning Electron Microscopy with Polarization Analysis (SEMPA) was used to image the surface magnetic domain structure of the 100 ${\mu}{\textrm}{m}$ thick 3% Si-Fe sheet. The thin-gauged 3% Si-Fe strips with magnetic induction ($B_{10}$) from 1.98 to 1.57 Tesla were prepared via conventional metallurgical processes including melting, hot-and cold-rolling, intermediate annealing and final annealing. Using SEMPA, it was observed that the $B_{10}$ (1.98 T) Tesla sample was almost composed of 180$^{\circ}$ stripe domains which are parallel to rolling direction. On the other hand the 3% Si-Fe sheet with $B_{10}$ (1.57 T) Tesla was composed of large 180$^{\circ}$stripe domains that are slanted about 30$^{\circ}$to the rolling direction and complex magnetic domain structures like tree and zigzag pattern. The 180$^{\circ}$stripe domains, which covered a major part of the sample, had (110)<001> Goss texture parallel to the rolling direction. The domain walls between 180$^{\circ}$stripe domains were the conventional Bloch type walls. On the other hand, the 90$^{\circ}$domains, which covered minor part on edge of the sample, were observed in (200) grains. The domain walls between 90$^{\circ}$domains were the Neel type walls. In high magnification, the elliptical singularity at the Neel walls was clearly observed.

  • PDF

투과형 기록구조에서 반사형 포토폴리머의 광학 특성 및 미세패턴 기록 (Optical Characteristic and Image Recording of Reflection Type Photopolymer in Transmission Structure)

  • 정현섭;김남;윤진선;박태형;신창원
    • 한국광학회지
    • /
    • 제18권1호
    • /
    • pp.8-13
    • /
    • 2007
  • 본 논문에서는 반사형 포토폴리머의 투과형 기록구조에서의 광학 특성을 분석하고 전반사 홀로그램 기법이 적용된 반사형 포토폴리머를 이용하여 미세패턴을 기록하였다. 투과형 포토폴리머는 대칭형 입사구조에서 $40^{\circ}$ 일 때 최대 효율을 보였으나 반사형 포토폴리머는 $60^{\circ}{\sim}80^{\circ}$에서 90% 이상의 회절효율을 보였다. 미세패턴 기록에서 10배 및 100배로 확대하여 측정한 결과 선 패턴과 점 패턴 간격 모두 $1{\mu}m$ 까지 구분할 수 있었다.