Pulsating fluid induced dynamic stability of embedded viscoelastic piezoelectric separators using different cylindrical shell theories

  • Pour, H. Rahimi;Arani, A. Ghorbanpour;Sheikhzadeh, Gh.
    • Steel and Composite Structures
    • /
    • 제24권4호
    • /
    • pp.499-512
    • /
    • 2017
  • This paper deals with nonlinear dynamic stability of embedded piezoelectric nano-composite separators conveying pulsating fluid. For presenting a realistic model, the material properties of structure are assumed viscoelastic based on Kelvin-Voigt model. The separator is reinforced with single-walled carbon nanotubes (SWCNTs) which the equivalent material properties are obtained by mixture rule. The separator is surrounded by elastic medium modeled by nonlinear orthotropic visco Pasternak foundation. The separator is subjected to 3D electric and 2D magnetic fields. For mathematical modeling of structure, three theories of classical shell theory (CST), first order shear deformation theory (FSDT) and sinusoidal shear deformation theory (SSDT) are applied. The differential quadrature method (DQM) in conjunction with Bolotin method is employed for calculating the dynamic instability region (DIR). The detailed parametric study is conducted, focusing on the combined effects of the external voltage, magnetic field, visco-Pasternak foundation, structural damping and volume percent of SWCNTs on the dynamic instability of structure. The numerical results are validated with other published works as well as comparing results obtained by three theories. Numerical results indicate that the magnetic and electric fields as well as SWCNTs as reinforcer are very important in dynamic instability analysis of structure.

Theoretical Analysis of Magnetic Flux Density Distribution in an Electro-Magnetic Chuck

  • Kim, Chung-Kyun
    • KSTLE International Journal
    • /
    • 제2권2호
    • /
    • pp.114-119
    • /
    • 2001
  • The distribution of magnetic flux density of electro-magnetic chucks may clarify the clamping characteristics, which is strongly related to the machining efficiency and machining accuracy in surface grinding machine. Therefore the distribution of the normal and the tangential components of magnetic flux density have been analyzed theoretically. It appears that the normal component of magnetic flux density increases and the tangential component of magnetic flux density increases as the ratio of the separator width to the pitch, e/p decreases. The results seem to increase the stability and uniformity of normal component of magnetic flux density for the decreased e/p.

  • PDF

산업폐수의 수처리를 위한 초전도 자기분리 장치 제작 (Superconducting Magnetic Separator for Purification of Industrial Wastewater)

  • 하동우;권준모;고락길;백승규;손명환;이유진;김태형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.44-44
    • /
    • 2010
  • Conventional water treatment facilities like precipitation process need large-scale equipment and wide space to purify the wastewater of paper factory. In case of massive waste water, high gradient magnetic separation (HGMS) parts are more effective to purify it rapidly and to occupy relatively small space, since large voids at filter with HGMS are adopted. Cryo-cooled Nb-Ti superconducting magnet with room temperature bore in diameter of 100 mm and 600 mm in height was used for magnetic separator. Magnetic filters were designed by the analysis of magnetic field distribution at superconducting magnets.

  • PDF

전자척에서 자속밀도 해석에 관한 연구 (Analysis of Magnetic Flux Density in Electro-Magnetic Chucks)

  • 김청균
    • 한국정밀공학회지
    • /
    • 제9권2호
    • /
    • pp.29-35
    • /
    • 1992
  • The distribution of magnetic flux density of electro-magnetic chucks may clarify the clamping characteristics which are strongly related to the machining efficiency and machining accuracy in a surface grinder. Therefore the distribution of the normal and the tangential components of magnetic flux density has been analyzed theoretically. It appears that the normal and the tangential components of magnetic flux density increase as the ratio of the separator width to the pitch e/p decreases. The results seem to increase the uniformity and stability of normal component of magnetic flux density for the decreased e/p.

  • PDF

Performance Determination of Novel Design Eddy Current Separator for Recycling of Non-Ferrous Metal Particles

  • Fenercioglu, Ahmet;Barutcu, Hamit
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.635-643
    • /
    • 2016
  • Improvements were made in the study for the design of the conventional Eddy Current Separator (ECS) used for separating small sized non-ferrous particles in the waste. These improvements include decreasing the air gap between the material and magnetic drum, making the drum position adjustable and placing the splitter closer to the drum. Thus, small particles were separated with high efficiency. The magnetic drum was removed from inside the ECS conveyor belt system as design change and was placed as a separate unit. Hence, the force generated on the test material increased by about 5.5 times while the air gap between the non-ferrous materials and drum decreased from 3 mm to 1 mm. The non-metal material in the waste is separated before the drum in the novel design. Whereas non-ferrous metal particles are separated by falling into the splitter as a result of the force generated as soon as the particles fall on the drum. Every material that passes through the drum can be recycled as a result of moving the splitter closer to the contact point of the drum. In addition, the drum can also be used for the efficient separation of large particles since its position can be adjusted according to the size of the waste material. The performance of the novel design ECS was verified via analytical approaches, finite element analysis (FEA) and experimental studies.

초전도 자기분리에 의한 제지폐수의 정수 (Purification of wastewater from paper factory by superconducting magnetic separator)

  • 하동우;김태형;권준모;손명환;백승규;오상수;하홍수;고락길;김호섭;김영훈;하태욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.342-343
    • /
    • 2009
  • Paper factories use a large amount of water and same amount of wastewater is generated. It is important to purity and recycle the wastewater because of water shortages and water pollution. The existing water treatment facilities like precipitation process need large-scale equipment and wide space to purity the wastewater of paper factory. High gradient magnetic separation (HGMS) system has the merits to purity rapidly because of large voids at filter and to occupy small space. In this paper, two types of superconducting magnets were used for HGMS systems. Cryo-cooled Bi-2223 superconducting magnet system with 70 mm room temperature bore and 200 mm of height was prepared. Cryo-cooled Nb-Ti superconducting magnet with 100 mm room temperature bore and 600 mm of height was used for magnetic separator. Magnetic filters were designed by the analysis of magnetic field distribution at superconducting magnets. The various magnetic seeding reactions were investigated to increase the reactivity of coagulation. The effects of magnetic separation of wastewater were investigated as variation of magnetic field strength and flow rate of wastewater.

  • PDF

전도냉각형 고온초전도 자석을 이용한 제지폐수의 자기분리에 의한 정수 (Purification of wastewater from paper factory by cryo-cooled high-$T_c$ superconducting magnetic separator)

  • 하동우;김태형;손명환;권준모;백승규;오상수;고락길;하홍수;김호섭;김영훈;강채훈;하태욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 춘계학술대회 논문집
    • /
    • pp.4-4
    • /
    • 2009
  • Paper factories use a large amount of water and same amount of wastewater is generated. It is important to recycle the wastewater because of water shortages and water pollution. The existing water treatment facilities like precipitation process need large-scale equipment and wide space to purify the wastewater of paper factory. High gradient magnetic separation (HGMS) system has the merits to purify rapidly because of large voids at filter and to occupy small space. In this paper, two types of superconducting magnets were used for HGMS systems. Cryo-cooled Bi-2223 superconducting magnet system with 70 mm room temperature bore and 200 mm of height was prepared. Cryo-cooled Nb-Ti superconducting magnet with 100 mm room temperature bore and 600 mm of height was used for magnetic separator. Magnetic filters were designed by the analysis of magnetic field distribution at superconducting magnets. The various magnetic seeding reactions were investigated to increase the reactivity of coagulation. The effects of magnetic separation of wastewater were investigated as variation of magnetic field strength and flow rate of wastewater.

  • PDF