• 제목/요약/키워드: Magnetic probe

검색결과 262건 처리시간 0.026초

Recent NMR developments for pharmaceutical research

  • Lee, Kwanghwan
    • 한국자기공명학회논문지
    • /
    • 제20권1호
    • /
    • pp.27-35
    • /
    • 2016
  • NMR spectrometer has been regarded as essential tool for structure elucidation in variable scientific field as like organic synthesis, natural product and macro protein research. Also NMR can be applied for defining dynamic behavior like ligand and receptor binding. One of advantage of research with NMR is that to be great confident to confirm structure and the measured sample could be recovered. Nevertheless NMR also has a weak points than other spectroscopic methods that require a lot of time for interpreting acquired spectrum and running time due to low sensitivity. For last two decade Bruker has developed hardware and software solution for overcome those weak points. In order to overcome low sensitivity Bruker introduced Cryo and Micro diameter probe head technology. And researcher can reduce the time for routine spectrum processing and interpretation works due to lots of introductions in software solutions for quantification, identification and statistics analysis. With four examples, this article describing those new hardware and software solutions in field of recent pharmaceutical research as follows. - New Horizons for NMR in the Biopharmaceutical Industry - The development and application of solid-state NMR spectroscopy (SSNMR) in pharmaceutical analysis - Assisted NMR Data Interpretation in Synthetic Chemistry - Complete Analysis of New Psychoactive Substances Using NMR.

PFG NMR Study of Intra-cellular Drug Uptake in Xenopus laevis Oocyte

  • Kwan, soo-Hong;Yeom Gyo-Seon;Kim, Eun-Hee;Lee, Chul-hyun;Lee, Sang-Do;Cheong, chae-joon
    • 한국자기공명학회논문지
    • /
    • 제9권1호
    • /
    • pp.29-37
    • /
    • 2005
  • Intra-cellular drug uptake in Xenopus laevis oocyte has been elucidated using localized MR spectroscopy (MRS) and PFG NMR techniques at a 600 $MH_z$(Bruker, 14.1 T) NMR spectrometer. The localized MRS has been done with a homemade probe, and shows the intra-cellular uptake of nicotinamide. The self-diffusion of the molecule in Xenopus oocyte was obtained by PFG NMR technique. The measured data are well fitted with a linear combination of two exponential functions, which shows that there are two types of drug molecules, intra-and extra-cellular molecules. Diffusion coefficients of intra- and extra-cellular drug molecules are 3.7 $\times$ $10^{-11}$ $\m^{2}/s$and 6.4 $\times$ $10^{-10}$ $\m^{2}/s$, respectively. In the weighting factors there is shown that about 5% of drug molecule is inside the cells. These techniques can be used for drug screening in molecule-, cell-, and tissue-based preclinical test.

  • PDF

Structural Studies of Peptide Binding Interaction of HCV IRES Domain IV

  • Shin, Ji Yeon;Bang, Kyeong-Mi;Song, Hyun Kyu;Kim, Nak-Kyoon
    • 한국자기공명학회논문지
    • /
    • 제21권3호
    • /
    • pp.109-113
    • /
    • 2017
  • The hepatitis C virus (HCV) internal ribosome entry site (IRES) is an RNA structure located in the 5'-UTR of the HCV RNA genome. The HCV IRES consists of four domains I, II, III, and IV, where domains II - IV are recognized by 40S ribosomal subunit and the domain III is bound to eukaryotic initiation factor 3 (eIF3) for translation initiation. Here, we have characterized the tertiary interaction between an L-/K- rich peptide and the HCV IRES domain IV. To probe the peptide binding interface in RNA, we synthesized $^{13}C$- and $^{15}N$-double labeled RNA and the binding site was identified by using the chemical shift perturbation (CSP) NMR methods. Our results showed that the peptide binds to the upper stem of the IRES domain IV, indicating that the tertiary interaction between the IRES domain IV and the peptide would disrupt the initiation of translation of HCV mRNA by blocking the start codon exposure. This study will provide an insight into the new peptide-based anti-viral drug design targeting HCV IRES RNA.

Role of Magnetic Field Configuration in a Performance of Extended Magnetron Sputtering System with a Cylindrical Cathode

  • Chun, Hui-Gon;Sochugov, Nikolay S.;You, Yong-Zoo;Soloviv, Andrew A.;Zakharov, Alexander N,
    • 반도체디스플레이기술학회지
    • /
    • 제2권3호
    • /
    • pp.19-23
    • /
    • 2003
  • Extended unbalanced magnetron sputtering system based on the cylindrical magnetron with a rotating cathode was developed. The unbalanced configuration of magnetic field was realized by means of additional lines of permanent magnets, placed along both sides of a 89 mm outer diameter and 600 mm long cylindrical cathode. The performance of the unbalanced magnetron was assessed in terms of the ion current density and the ion-to-atom ratio incident at the substrate. Furthermore, the paper presents the comparison of the internal plasma parameters, such as the electron temperature, electron density, plasma and floating potentials, measured by a Langmuir probe in various positions from the cathode, for conventional and unbalanced constructions of the cylindrical magnetron. The plasma density and ion current density are about 3-5 times higher than those of conventional one, in the unbalanced magnetron in a 0.24 Pa Ar atmosphere with a DC cathode power of 3 kW.

  • PDF

자성 산화철(iron oxide) 나노입자를 이용한 DNA 센서 개발 (Development of DNA Sensor Using Magnetic Iron Oxide Nanoparticle)

  • 남기창;송광섭
    • 전자공학회논문지SC
    • /
    • 제48권6호
    • /
    • pp.51-56
    • /
    • 2011
  • 자성 산화철 나노입자(iron oxide nanoparticle, ${\gamma}-Fe_2O_3$) 표면을 기능성 유기 분자를 이용하여 아민기($-NH_2$), 카르복실기(-COOH)로 표면 처리 하였으며, 이들 기능기로 표면 처리된 산화철 나노입자를 FT-IR을 이용하여 나노입자 표면을 분석하였다. 아민기, 카르복실기로 표면처리된 산화철 나노입자 표면에 특정 배열을 갖는 21-base pair 길이의 프로브 DNA를 고정하였고, 형광 라벨(Cy5)이 부착된 상보적, 비상보적 타게트 DNA를 이용하여 고정된 프로브 DNA와 hybridization을 진행하였다. 각각의 상보적, 비상보적 타게트 DNA와 hybridization 처리한 산화철 나노입자를 confocal microscopy를 이용하여 관찰하였으며, 그 결과 산화철 나노입자를 이용하여 특정 배열의 DNA검출에 성공하였다.

열처리 조건에 따른 Tb이온의 확산 및 Nd-Fe-B 자석의 자기적 특성 (Inward Diffusion of Tb Ions and the Magnetic Properties of the Nd-Fe-B Magnets)

  • 오성욱;김동환;공군승;허영우;김정주;이준형
    • 한국전기전자재료학회논문지
    • /
    • 제30권1호
    • /
    • pp.27-31
    • /
    • 2017
  • In this study, the effect of Tb inward diffusion on the magnetic properties of the Nd-Fe-B sintered magnets was studied. After sintering of the magnets, $TbF_3$ slurries were dip-coated on the surface of the samples, then heat-treatment was followed for $TbF_3$ diffusion. The element distribution in the magnets and the diffusion profiles of Tb ions were analyzed by an EPMA (electron probe micro-analyzer). Prolonged heat treatment resulted in a deeper diffusion length of Tb ions. Coercivity of the $1^{st}$ heat-treated sample showed 21.86 kOe, while that of the $1^{st}$, $2^{nd}$ heat-treated and annealed sample revealed 34 kOe.

Per-deuteration and NMR experiments for the backbone assignment of 62 kDa protein, Hsp31

  • Kim, Jihong;Choi, Dongwook;Park, Chankyu;Ryu, Kyoung-Seok
    • 한국자기공명학회논문지
    • /
    • 제19권3호
    • /
    • pp.112-118
    • /
    • 2015
  • Hsp31 protein is one of the members of DJ-1 superfamily proteins and has a dimeric structure of which molecular weight (MW) is 62 kDa. The mutation of DJ-1 is closely related to early onset of Parkinson's disease. Hsp31 displays $Zn^{+2}$-binding activity and was first reported to be a holding chaperone in E. coli. Its additional glyoxalase III active has recently been characterized. Moreover, an incubation at $60^{\circ}C$ induces Hsp31 protein to form a high MW oligomer (HMW) in vitro, which accomplishes an elevated holding chaperone activity. The NMR technique is elegant method to probe any local or global structural change of a protein in responses to environmental stresses (heat, pH, and metal). Although the presence of the backbone chemical shifts (bbCSs) is a prerequisite for detailed NMR analyses of the structural changes, general HSQC-based triple resonance experiments could not be used for 62 kDa Hsp31 protein. Here, we prepared the per-deuterated Hsp31 and performed the TROSY-based triple resonance experiments for the bbCSs assignment. Here, detailed processes of per-deuteration and the NMR experiments are described for other similar NMR approaches.

차세대 정보저장시스템 최신 기술 동향 (Technology Trend of Next Generation Information Storage Systems)

  • 박영필;임윤철;양현석;강신일;박노철;김영주
    • 정보저장시스템학회논문집
    • /
    • 제1권1호
    • /
    • pp.1-22
    • /
    • 2005
  • There are two important trends in the modern information society, including digital networking and ubiquitous environment. Thus it is strongly required to develop new information storage devices such as high density storages to match the increased data capacity and small size storage devices to be applied to the mobile multimedia electronics. So far, many approaches have been studied for the high density memory, including the holographic memory, super-RENS and near-field recording using solid immersion lens (SIL) or nano-probe for the ODD (Optical Disk Drive) system, and the perpendicular magnetic recording and heat-assisted magnetic recording for the HDD (Hard Disk Drive) system. In addition, new mobile storage devices have been prepared using 0.85" HDD and 30mm ODD systems from a lot of foreign and domestic companies and institutes. In this paper, the recent technology trend for the next generation information storage system is summarized to offer a research motivation and encouragement to new researchers in this field with an emphasis on the technical issues of the increase of data capacity and decrease of device size.

  • PDF

Magnetic and Electrical Properties of the Spin Valve Structures with Amorphous CoNbZr

  • Cho, Hae-Seok
    • Journal of Magnetics
    • /
    • 제2권3호
    • /
    • pp.96-100
    • /
    • 1997
  • A spin valve structure of NiO(40 nm)/Co(2 nm)/Cu(2.6 nm)/Co(x nm)/Ta(5 nm) has been investigated for the application of magnetic random access memory (MRAM). The spin valve structure exhibited very large difference in the coercivities between pinned and free layers, a relatively high GMR ratio, and a low free layer coercivity. The spin valves were prepared by sputtering and were characterized by dc 4-point probe, and VSM. The spin valves with combined free layer exhibited a maximun GMR ratio of 10.4% with a free layer coercivity of about 82 Oe. The spin valves with a single 10 nm thick a-CoNbZr free layer exhibited a GMR ratio of about 4.3% with a free layer coercivity of about 12 Oe. The GMR ratio of the spin valves increased by addition of Co between Cu and a-CoNbZr. It has been confirmed that the coercivity of free layer can be decreased by increasing the thickness of a-CoNbZr. It has been confirmed that the coercivity of free layer can be decreased by increasing the thickness of a-CoNbZr layer without losing the GMR ratio substantially, which was mainly due to high resistivity of the amorphous "layers".

  • PDF

전자선 안정화에 의한 니켈 나노 입자가 분산된 탄소섬유의 전자기적 특성 향상 (Enhanced Electromagnetic Properties of Nickel Nanoparticles Dispersed Carbon Fiber via Electron Beam Irradiation)

  • 이영주;김현빈;이승준;강필현
    • 방사선산업학회지
    • /
    • 제9권1호
    • /
    • pp.15-20
    • /
    • 2015
  • Carbon fiber has received much attention owing to its properties, including a large surface-to-volume ratio, chemical and thermal stability, high thermal and electrical conductivity, and high mechanical strengths. In particular, magnetic nanopowder dispersed carbon fiber has been attractive in technological applications such as the electrochemical capacitor and electromagnetic wave shielding. In this study, the nickel-oxide-nanoparticle dispersed polyacrylonitrile (PAN) fibers were prepared through an electrospinning method. Electron beam irradiation was carried out with a 2.5 MeV beam energy to stabilize the materials. The samples were then heat-treated for stabilization and carbonization. The nanofiber surface was analyzed using a field emission scanning electron microscope (FE-SEM). The crystal structures of the carbon matrix and nickel nanopowders were analysed using X-ray diffraction (XRD). In addition, the magnetic and electrical properties were analyzed using a vibrating sample magnetometer (VSM) and 4 point probe. As the irradiation dose increases, the density of the carbon fiber was increased. In addition, the electrical properties of the carbon fiber improved through electron beam irradiation. This is because the amorphous region of the carbon fiber decreases. This electron beam effect of PAN fibers containing nickel nanoparticles confirmed their potential as a high performance carbon material for various applications.