• Title/Summary/Keyword: Magnetic field shielding

Search Result 99, Processing Time 0.026 seconds

Analysis and Improvement of Shielding Effect of Electromagnetic Field in Extremely Low Frequency System (극저주파 시스템에서 전자장 차폐효과 해석 및 개선 방안)

  • Kim, Sang-Hon;Choi, Hong-Soon;Park, Il-Han
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.978-979
    • /
    • 2006
  • Recently, Peoples are exposed the ELF(Extremely Low Frequency) magnetic fields in the vicinity of underground transmission lines, and there are the generally accepted opinion that the magnetic fields affect the human body and there are possibility of the disease. Also in relation to this problem, technical solution methods and research are advanced for reducing the magnetic fields. In this paper, to practically understand the magnetic fields underground transmission lines, We analyze the electromagnetic field distribution in the underground transmission lines by means of FEM(Finite Element Methods) and present that improvement of the effective shielding methods by applying cable arrangements and shielding materials, eddy current problem to the underground transmission lines by means of the numerical analysis Tool.

  • PDF

Magnetic Field Reduction Characteristics of Shielding Wear Materials for Workers Using AC Arc Welder (교류 아크용접기를 사용하는 작업자의 차폐복 재질에 따른 자계저감 특성검토)

  • Park, Jun-Hyeong;Min, Suk-Won;Lee, Seung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.7
    • /
    • pp.1265-1271
    • /
    • 2010
  • Power cable of an AC arc welder can surround a body of worker at the moment of welding. Applying the boundary element method, we calculated current densities induced in organs inside a worker to study the magnetic field reduction characteristics of shielding wear materials. We knew shielding wear with high permeability materials lowers current density more than high conductivity materials. We also found current density was lowest when high permeability materials were inside high conductivity materials in double layer shielding wear.

Influence of Sintering Temperature on Magnetic Properties of Ni-Zn-Cu Ferrites Used for Mangetic Shielding in NFC (NFC의 자기차폐용 Ni-Zn-Cu 페라이트의 자기특성에 미치는 소결온도의 영향)

  • Ryu, Yo-Han;Kim, Sung-Soo
    • Journal of Powder Materials
    • /
    • v.23 no.2
    • /
    • pp.132-135
    • /
    • 2016
  • This study investigates the influence of sintering temperature on the magnetic properties and frequency dispersion of the complex permeability of Ni-Zn-Cu ferrites used for magnetic shielding in near-field communication (NFC) systems. Sintered specimens of $(Ni_{0.7}Zn_{0.3})_{0.96}Cu_{0.04}Fe_2O_4$ are prepared by conventional ceramic processing. The complex permeability is measured by an RF impedance analyzer in the range of 1 MHz to 1.8 GHz. The real and imaginary parts of the complex permeability depend sensitively on the sintering temperature, which is closely related to the microstructure, including grain size and pore distribution. In particular, internal pores within grains produced by rapid grain growth decrease the permeability and increase the magnetic loss at the operating frequency of NFC (13.56 MHz). At the optimized sintering temperature ($1225-1250^{\circ}C$), the highest permeability and lowest magnetic loss can be obtained.

Calculation of induced currents and analysis of shielding effectiveness in finite conductive shield (도전성 유한 차폐판의 유도전류 계산 및 차폐효과 분석)

  • Kang, Dael-Ha;Son, Jung-Dae;Lee, Yung-Sik;Jo, Yeong-Ho;Choi, Phil-Soo;Park, Sang-Ho;Kim, Won-Hi
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.551-552
    • /
    • 2011
  • In this study new evaluation method of eddy currents in conductive shielding sheets are introduced. This method is based on the magnetic flux linkage in rectangular cells. According to this method the allocated amount of memory and the calculation time can be reduced. In this method calculation of magnetic field in any space can be performed by summing contributions of source currents and eddy currents in conductive shielding sheets. This method is applicable to the design of magnetic field-shield.

  • PDF

Electromagnetic Shielding Effectiveness of a Soft Magnetic Film for Application of Noise Reduction In RE Range (RF대역 노이즈 저감용 연자성 필름의 전자기파 차폐효과)

  • Kim Sang-Woo;Yun Yong-Woon;Kim Gwang-Yoon;Lee Yo-Chun;Lee Kyung-Sup
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.3 s.32
    • /
    • pp.31-36
    • /
    • 2004
  • We charaterized electromagnetic shielding properties of a soft magnetic film using by a ASTM method and 2-port flanged coaxial line method in a RF range and quantitatively analyzed factors for the shielding effectiveness of the soft magnetic film in far field. The shielding effectiveness of the soft magnetic film was dominantly affected by absorption loss not reflection loss in high frequency range of 4-13.5 GHz.

  • PDF

Magnetic Shielding Effect of Amorphous Strips in Low Frequency Field (비정질 연자성재료를 이용한 복층 차폐체의 저주파 자기장 차폐효과)

  • Kim, S.G.;Hur, J.;Park, P.G.;Chung, Y.C.;Kim, Y.B.;Kim, T.K.
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.6
    • /
    • pp.341-345
    • /
    • 1998
  • Magnetic shielding effect of cylinderical ahields made of commericial amorphous ribbons has been studied. The shell-arrangement-order of double shell shield has been found to show a striking differencein shielding factor. In low applied field region, a 2605CO-2705M-shield (outer shell: 2605CO, inner shell: 2705M) yields two times higher shielding factor than a 2705M-2605CO-shield (outer shell: 2705M, inner shell: 2605CO). The reasons are as follows: In case of 2605CO-2705M-shield, the outer shell is not easily saturated and effectively shields the applied field. In addition, the inner shell shows high shielding factor in the field shielded by the outer shell. In case of 2705M-2605CO-shield, the outer shell is saturated at very low-field as well as the inner shell shows low shielding factor in the field shielded by the outer shell.

  • PDF

Characteristics of Wireless Power Transmission Using Superconductor Coil to Improve the Efficiency According to the Shielding Materials (초전도 공진 코일의 효율성을 높이기 위한 차폐 재질에 따른 무선전력전송 효율비교 분석)

  • Lee, Yu-Kyeong;Jeong, In-Sung;Hwang, Jun-Won;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.684-688
    • /
    • 2016
  • The magnetic resonance method requires high quality factor(Q-factor) of resonators. Superconductor coils were used in this study to increase the Q-factor of wireless power transfer(WPT) systems in the magnetic resonance method. The results showed better transfer efficiency compared to copper coils. However, as superconducting coils should be cooled below critical temperatures, they require cooling containers. In this viewpoint, shielding materials for the cooling containers were applied for the analysis of the WPT characteristics. The shielding materials were applied at both ends of the transmitter and receiver coils. Iron, aluminum, and plastic were used for shielding. The electric field distribution and S-parameters (S11, S21) of superconducting coils were compared and analyzed according to the shield materials. As a result, plastic shielding showed better transfer efficiency, while iron and aluminum had less efficiency. Also, the maximum magnetic field distribution of the coils according to the shielding materials was analyzed. It was found that plastic shielding had 5 times bigger power transfer rate than iron or aluminum. It is suggested that the reliability of superconducting WPT systems can be secured if plastic is used for the cooling containers of superconducting resonance coils.

Magnetic Shielding with Thin Magnetic Materials near Power Cables (박판 자성 재료를 이용한 전력 케이블 인근의 자기장 차폐)

  • Kim, Sang-Beom;Soh, Joon-Young;Shin, Koo-Yong;Jeong, Jin-Hye;Myung, Sung-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.7
    • /
    • pp.639-647
    • /
    • 2009
  • In this work, wrapping conductors with thin magnetic materials is proposed as a magnetic shielding method. The 0.1 mm thick metal sheets of mu-metal, grain-oriented electrical steel, and non-oriented electrical steel were produced from commercial alloy sheets through cold rolling and followed high temperature annealing. In case of 3-phase electric currents, mu-metal was the best in shielding performance at a B-field magnitude of about 100 ${\mu}T$, whereas silicon steels were better than mu-metal at a B-magnitude over 500 ${\mu}T$. In addition, wrapping with silicon steel(inner) together with mu-metal(outer) resulted in a shielding factor less than 0.1 even at 500 ${\mu}T$. These results are due to changes in hierarchy of magnetic permeabilities of the materials with increasing magnetic field strength. In case of single-phase electric current, B-magnitude outside the magnetic shell was rather increased compared to the unshielded case. This result is explained by vector composition of B-fields near magnetic shielding materials.

Boundary Element Analysis of Magnetic Shielding Effects of Shield Cup in Electron Gun (경계요소법을 이용한 전자총 Shield Cup의 자기차폐 특성해석)

  • Go, Chang-Seop;Jeong, Gwan-Sik;Han, Song-Yeop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.5
    • /
    • pp.291-296
    • /
    • 2000
  • Recently large size color TV and computer monitor are very popular and a lot techniques are being developed to get a high quality picture on the screen through reducing the convergence error among the red, green and blue beams and achieving a high focusing. One of the techniques is considering the mutual effects of the components of the Brown tube. The magnetic deflection yoke, especially, stands immediately next to the electron gun and generates the leakage magnetic fields at the electron gun which affects the trajectories of the electron beams inside the gun. Hence a shield cup made of thin conducting plate is located at the end of electron gun in order to shield the leakage flux from the deflection yoke. Since the red, green and blue beams are placed unsymmetrically the shielding effects of the shield cup on the beams are not same and eddy current controller, made of thin conducting plate, is auxiliary placed inside the shield cup. In this paper a transient magnetic field analysis algorithm is developed using boundary element method, and applied to the analysis of the shielding effects of the eddy current controller of shield cup in an electron gun.

  • PDF

Electromagnetic Wave and EMF Attenuation by Shielding Materials in home appliances (가전제품 전자파 현황 및 차폐재에 의한 감쇄 효과)

  • Cho, Jae-Cheol;Park, Jae-Hwan
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.6
    • /
    • pp.711-718
    • /
    • 2019
  • Spectrum analyzer and electromagnetic field meter were used to investigate the EM generation behaviour in different types of home electrical appliances. During microwave oven operation, the EM power measured at a point 30cm apart was measured in the range of 8~11mW/㎡, the strength of the low frequency magnetic field was 60~80mG and the electric field strength was measured at 150~160V/m. For smart phone wireless charging pad, it was measured at an electromagnetic power of 0.4mW/㎡, an electric field of 160 V/m and a magnetic field of 1mG at a point 10cm away. For microwave oven and wireless charging pad, if used within 10cm, the size of the electric field has been measured at a large value that exceeds the human body protection standard and may be hazardous to humans. On the other hand, home appliances such as TVs, hairdryers and refrigerators all showed very low levels of electromagnetic waves, electric fields and magnetic fields, with no harmful effects seen. For electromagnetic shielding, the metal Cu fabric and metal foil had a high level of EM shielding, while polymer films had a low EM shielding characteristic.