• Title/Summary/Keyword: Magnetic device

Search Result 934, Processing Time 0.031 seconds

Preparation of Photosensitizer-Coated Ferrofluids and Fabrication of a Device for Photodynamic Therapy (광감제가 코팅된 자성유체의 제조와 광역학 치료용 장치의 구성)

  • Gwon, Sun-Gwang;Kim, Jong-O;Kim, Jong-Hui
    • Korean Journal of Materials Research
    • /
    • v.12 no.3
    • /
    • pp.215-219
    • /
    • 2002
  • For the purpose of annihilating tumor in body, hematoporphyrin as a photosensitizer was coated onto magnetic particles of $Fe_3O_4$ prepared by coprecipitation which could be concentrated around the tumor by magnetic field. The photosensitizer was applied differently before, during and after adsorbing the 1st surfactant on the particles. Its added amount was $5{\times}10^{-4}/mol$, and the coating reaction proceeded at temperatures of 60, 70 and 8$0^{\circ}C$. The amounts of photosensitizer coated on the magnetic particles were obtained by calculating an optical density with the maximum UV spectrum. As a result of the UV analysis, the coating amount of photosensitizer increased with higher reaction temperatures. When applied at 8$0^{\circ}C$ after adsorbing the 1st surfactant, the photosensitizer was coated with a maximum value of $3.8{\times}10^{-3}/mo1/$\ell$$. The TGA analysis revealed that the ferrofluids included the particles of 30.115 g/$\ell$. It was suggested that the magnetite particles was coated with photosensitizer of $1.26{\times}10^{-4}/mo1/g$. A small-sized device for magnetic field and light emission was designed, in which LED sheets coverts the permanent magnet of Nd-Fe-B. The LED sheet was connected in series circuit and also protected with a silicon tube. The power was supplied with rechargable battery of 9V and 100-120mA.

Study of Superparamagnetic Microneedles containing Iron Oxide Nanoparticles (산화철 나노입자를 함유한 초상자성 마이크로니들에 관한 연구)

  • Lee, Seung-Jun
    • Applied Chemistry for Engineering
    • /
    • v.32 no.5
    • /
    • pp.556-561
    • /
    • 2021
  • Recently, iron oxide nanoparticles have been used as the subject of many studies on drug delivery system (DDS) due to their excellent magnetic properties and biocompatibility in response to external magnetic fields. In this study, hyaluronic acid-superparamagnetic microneedles (HA-SMNs) and carboxy methyl cellulose-superparamagnetic microneedles (CMC-SMNs) containing superparamagnetic iron oxide nanoparticles (SIONs) were prepared with HA and CMC as a matrix materials of MNs (microneedles). Various properties of SMNs were then investigated with scanning electron microscopy (SEM), superconducting quantum interference device-vibrating sample magnetometer (SQUD-VSM), frequency mixing magnetic detection (FMMD), and polymer/bio membrane. The SQUID-VSM measurements showed superparamagnetism of HA-SMNs and CMC-SMNs containing SIONs. The FMMD results demonstrated that the signal intensity changed significantly as the concentration of SIONs increased. In addition, SMNs exhibited the average skin permeability intensities on the bio membrane for HA-SMNs and CMC-SMNs were 92.5 and 98.5%, respectively. These results suggested that SMNs could be utilized as deliver materials for a TDDS and MR molecular imaging.

A study on digital locking device design using detection distance 13.4mm of human body sensing type magnetic field coil (인체 감지형 자기장 코일의 감지거리 13.4mm를 이용한 디지털 잠금장치 설계에 관한 연구)

  • Lee, In-Sang;Song, Je-Ho;Bang, Jun-Ho;Lee, You-Yub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.9-14
    • /
    • 2016
  • This study evaluated a digital locking device design using detection distance of 13.4mm of a human body sensing type magnetic field coil. In contrast to digital locking devices that are used nowadays, the existing serial number entering buttons, lighting, number cover, corresponding pcb, exterior case, and data delivery cables have been deleted and are only composed of control ON/OFF power switches and emergency terminals. When the magnetic field coil substrates installed inside the inner case detects the electric resistance delivered from the opposite side of the 12mm interval exterior contacting the glass body part, the corresponding induced current flows. At this time, the magnetic field coil takes the role as a sensor when coil frequency of the circular coil is transformed. The magnetic coil as a sensor detects a change in the oscillation frequency output before and after the body is detected. This is then amplified to larger than 2,000%, transformed into digital signals, and delivered to exclusive software to compare and search for embedded data. The detection time followed by the touch area of the body standard to a $12.8{\emptyset}$ magnetic field coil was 30% contrast at 0.08sec and 80% contrast at 0.03sec, in which the detection distance was 13.4mm, showing the best level.

The Microfluidic Device using Viscosity Deviation of Magnetic Fluids Due to Temperature Changes (자성유체의 온도에 따른 점성 변화를 이용한 미소 유체 소자)

  • Choi, Bum-Kyoo;Oh, Jae-Geun;Ahn, Jeong-Jae
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.473-478
    • /
    • 2004
  • This study focused on the charateristic of magnetic fluids, the viscosity deviation of magnetic fluids due to temperature changes, and fabrication of a 'purely' liquid type microvalve. The viscosity of magnetic fluids decreases sharply during increasing of temperature. The viscosity of magnetic fluids is rated 1,000 cP at the room temperature and 25 cP when the temperature reaches $100^{\circ}C$. Briefly, it is remarkable that the fluid flow can be controlled by the temperature and this characteristic can be adopted to the microfluidics as a microvalve. The fabrication of a liquid type microvalve is more easy than solid state microvalves and which can increase an efficiency of the controlability with respect to the thermo-pneumatic micropump which is studied broadly for many years. When the magnetic fluid used as a sealant for high level sealing, the pressure leakage is less than solid state microvalve. The experimental results show that the pressure drop in microchannel, filled with the magnetic fluid, is significant in the temperature range of $20^{\circ}C{\sim}50^{\circ}C$ and this result explains why the use of magnetic fluids is possible as a microvalve searcher uses this characteristics. Well known thermo-pnumatic.

Ground Detection Method for Removement of Earth Field for Magnetic Guidance System (자계안내시스템용 지자계 제거를 위한 Ground 검출법)

  • Im, Dae-Yeong;Jung, Young-Yoon;Ryoo, Young-Jae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.16 no.5
    • /
    • pp.581-586
    • /
    • 2006
  • In this paper, describes ground detection method for removal earth field of magnet guidance system Magnetic guidance system is magnetic markers are installed just under the surface of roadway pavement and the magnetic fields generated these markers are detected by magnetic field sensor mounted of vehicles. vehicle is know lot lateral distance using magnetic field. But sensor is together measuring the magnetic field and earth field. It is operate error. Thus in this paper, proposed new method removing earth field or development experiment device via show the for practical and excellence.

Finite Element analysis of Magnetic Actuators with permanent magnet (영구자석을 갖는 마그네틱 액추에이터의 유한요소 해석)

  • Park, Jeong-Hong;Seo, Jeong-Ho;Joo, Su-Won;Hahn, Sung-Chin
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.857-859
    • /
    • 2002
  • This paper describes an analysis of Magnetic actuator with permanent magnet using 2-D axisymmetric finite element method. Magnetic actuator is the machine to change electrical signal into mechanical signal, and fast switching device to be used for breaker and automation field etc. This magnetic actuator considered action for armature distance, external circuit, and nonlinear material characteristic and current. Also, comparative analysis is performed for 2 coil type and 1 coil type by coil type of actuator, then characteristic is grasped. It is Combined with external circuit for analyzing transient characteristic by variable time. According to the results, we analyzed action characteristic of Magnetic actuator.

  • PDF

Analysis of Novel Magnetic-Spring Actuators for Portable Units (휴대장치용 새로운 자기 스프링 액추에이터의 해석)

  • 한인환
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.12
    • /
    • pp.1942-1949
    • /
    • 2004
  • SLA(Scanned Linear Array) is a portable display unit for implementing next-generation virtual realities, utilizes a design that light generated by a line of LEDs is reflected from the rapidly oscillating mirror to generate a raster display. Reaction forces generated by the motions of the mirror and counter-balance mass cancel each other at the device base, reducing vibration. Metal leaf springs have been extensively applied in such portable units. Magnetic springs have been developed and adopted that can replace the metal spring and can avoid many disadvantages of metal springs. We model and analyze the dynamics of the structure with magnetic springs and present the simulation and experimental analysis results, which can be utilized for identifying and eliminating possible problem sources in removing shaking forces and moments, and oscillating the mirror at the required amplitude and frequency. Finally, we present the improved novel magnetic actuator model which can be applied in portable display units.

Microfluidic immunoassay using superparamagnetic nanoparticles in an enhanced magnetic field gradient (강화된 자기장 구배 하에서 나노자성입자를 이용한 미세유체 기반의 면역 측정)

  • Hahn, Young-Ki;Kang, Joo-H.;Kim, Kyu-Sung;Park, Je-Kyun
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.158-163
    • /
    • 2006
  • This paper reports a novel immunoassay method using superparamagnetic nanoparticles and an enhanced magnetic field gradient for the detection of protein in a microfluidic device. We use superparamagnetic nanoparticles as a label and fluorescent polystyrene beads as a solid support. Based on this platform, magnetic force-based microfluidic immunoassay is successfully applied to analyze the concentration of IgG as model analytes. In addition, we present ferromagnetic microstructure connected with a permanent magnet to increase magnetic flux density gradient (dB/dx, ${\sim}10^{4}$ T/m), which makes limit of detection reduced. The detection limit is reduced to about 1 pg/mL.

A Study on the Ultra-Precision Polishing Technique for the Upper Surface of the Micro-Channel Structure (미세채널 구조물 상부의 초정밀 연마 기술 연구)

  • 강정일;이윤호;안병운;윤종학
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.313-317
    • /
    • 2003
  • Micro-Channel ultra-precision polishing is a new technology used in magnetic field-assisted relishing. In this paper, an electromagnet or the i18 of test system was designed and manufactured. A size of magnetic abrasive is used on 25~75${\mu}{\textrm}{m}$ and for the polish a micro-channel upper part. A surface of channel which is not even is manufactured using magnetic abrasive finishing at upper surface of micro-channel. As a result, the surface roughness rose by 80% after upper surface of micro- channel was polished up 8 minutes by polishing.

  • PDF