• Title/Summary/Keyword: Magnetic collection

Search Result 66, Processing Time 0.023 seconds

A Study on the Application of the RFID Technology to Libraries (RFID 기술의 도서관 적용 방안 연구)

  • Lee, Jong-Moon
    • Journal of Korean Library and Information Science Society
    • /
    • v.38 no.1
    • /
    • pp.157-171
    • /
    • 2007
  • In this study, the usefulness of the RFID technology, which has been recommended to be used in libraries, is reviewed by its technical aspect and the successful methods derived from RFID-applied libraries is presented to other libraries. More precisely, it is advised that checking out or returning books and materials, checking a collection of books, identifying misplaced materials, and theft-proofing materials, which have been previously performed using bar codes or the magnetic tapes, should be automated through RFID additionally the method to apply the technology to library's facilities or devices is proposed.

  • PDF

The Dynamic Characteristics Analysis Between Pantograph and Catenary System Using Block Pulse Function (블럭펄스함수를 이용한 판토그래프와 가선시스템사이의 동특성 해석)

  • Shin, Seung-Kwon;Song, Yong-Soo;Eum, Ju-Hwan;Eum, Ki-Young
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.748-750
    • /
    • 2004
  • The pantograph should supply the electrification equipments of a train with the current from the overhead catenary system over a broad range of speeds. For a high-speed electrical train, the dynamic interaction between the pantograph and the overhead catenary system causes the variation of the contact force. As the operational speed increases, the variation of the contact force increases. The contact force variation can cause contact losses, arcing and sparking. If the spark happens between the pantograph and the overhead catenary system, the EMI(electro magnetic interface) and noises may occur. After all, the quality of current collection is deteriorated. This paper deals with the dynamic characteristics analysis between pantograph and catenary system using block pulse function.

  • PDF

256-channel 1ks/s MCG Signal Acquisition System (256-channel 1 ksamples/sec 심자도 신호획득 시스템)

  • Lee, Dong-Ha;Yoo, Jae-Tack;Huh, Young
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.538-540
    • /
    • 2004
  • Electrical currents generated by human heart activities create magnetic fields represented by MCG(MagnetoCardioGram). Since an MCG signal acquisition system requires precise and stable operation, the system adopts hundreds of SQUID(Superconducting QUantum Interface Device) sensors for signal acquisition. Such a system requires fast real-time data acquisition in a required sampling interval, i.e., 1 mili-second for each sensor. This paper presents designed hardware to acquire data from 256-channel analog signal with 1 ksamples/sec speed, using 12-bit 8-channel ADC devices, SPI interfaces, parallel interfaces, 8-bit microprocessors, and a DSP processor. We implemented SPI interface between ADCs and a microprocessor, parallel interfaces between microprocessors. Our result concludes that the data collection can be done in $168{\mu}sec$ time-interval for 256 SQUID sensors, which can be interpreted to 6 ksamples/sec speed.

  • PDF

Detection of Ions in ECR $H_2$ Plasma Using Omegatron Mass Spectrometer (오메가트론을 이용한 ECR 수소 플라프마 내의 이온 검출)

  • Park, Jung-Woo;Jeong, Heui-Seob;Kim, Gon-Ho;Whang, Ki-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.459-461
    • /
    • 1995
  • An omegatron mass spectrometer was designed and fabricated. Experiments have been performed to demonstrate the instrument's operation in the ECR plasma device. By using this analyzer, mass spectra have been obtained in hydrogen plasmas, and typical results are presented. In the plasma omegatron, downstreaming plasma generated by ECR are entering the analyzer through a smsll floating aperture. We employ a biasing technique to reduce the ion velocity along the magnetic field and to keep the ions from drifting to the side pintos, and thus achieved improved ion collection and sensitivity. Mass spectra obtained show that main positive ion components are $H_3{^+}$ and $H_2{^+}$ with the density ratio of $H_2{^+}$ to $H_3{^+}$ $\simeq$ 0.2.

  • PDF

The analysis of the dynamic response between the pantograph and overhead wire (고속열차 주행을 위한 판토그래프와 가선시스템과의 동적응답 해석)

  • Shin Seung-Kwon;Song Yong-Soo;Mun Hyung-Scok;Eum Ki-Young;Kim Jae-Mun
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1366-1371
    • /
    • 2004
  • The development of the European railway high speed network brings new problems related to the interoperability across the railways of different countries. The pantograph and the overhead wire form a dynamic coupled system and they affect each other through the contact force. Unfortunately, as the operational speed of a train increases, the vibration of the pantograph and the overhead wire also increases. This may lead to a zero contact force between the pantograph head and the overhead wire, which can results in the loss of contact, arching and abrasion. If the arching and spark happen between the pantograph and the overhead catenary system, the EMI(electro magnetic interface) and noises may occur. After an, the quality of current collection is deteriorated. This paper describes the dynamic response between the pantograph and catenary system by the numerical simulations and predicts the possibility of operating the high speed train in the conventional lines.

  • PDF

Multiplexed single-molecule flow-stretching bead assay for DNA enzymology

  • Lee, Ryanggeun;Yang, Keunsang;Lee, Jong-Bong
    • BMB Reports
    • /
    • v.52 no.10
    • /
    • pp.589-594
    • /
    • 2019
  • Single-molecule techniques have been used successfully to visualize real-time enzymatic activities, revealing transient complex properties and heterogeneity of various biological events. Especially, conventional force spectroscopy including optical tweezers and magnetic tweezers has been widely used to monitor change in DNA length by enzymes with high spatiotemporal resolutions of ~nanometers and ~milliseconds. However, DNA metabolism results from coordination of a number of components during the processes, requiring efficient monitoring of a complex of proteins catalyzing DNA substrates. In this min-review, we will introduce a simple and multiplexed single-molecule assay to detect DNA substrates catalyzed by enzymes with high-throughput data collection. We conclude with a perspective of possible directions that enhance capability of the assay to reveal complex biological events with higher resolution.

Technological Advances for Particulate Matter Collection in Subway System (지하철 미세먼지 포집을 위한 기술적 진보)

  • Son, Youn-Suk;Ryu, Jae-Yong
    • Prospectives of Industrial Chemistry
    • /
    • v.21 no.2
    • /
    • pp.24-34
    • /
    • 2018
  • 본 연구에서는 지하역사 및 터널에서 발생되는 미세먼지의 현황 및 이를 저감하기 위한 기술의 동향을 조사하였다. 지하역사 및 터널의 미세먼지 농도는 주변 대기 중의 농도보다 높은 것으로 나타났다. 그 구성 성분에 있어서 다양한 중금속 및 발암물질들을 함유하고 있고, Fe의 농도가 가장 높게 나는 것을 알 수 있었다. 지하역사 및 터널의 미세먼지 농도는 주변 대기 농도와 같은 외부 요인뿐만 아니라 열차의 운행 수, 이용 승객수, 환기량과 같은 내부 요인도 큰 영향을 미치는 것을 확인할 수 있었다. 현재 지하역사 및 터널의 미세먼지를 저감하기 위해서 다양한 기술(환기팬, 스크린도어, 자성필터, 소형제트팬, 인공지능 환기시스템 등)들이 연구되고 있으며, 그 기술들은 현장 조건에 맞추어 사용되어야 그 실효성을 극대화시킬 수 있을 것이다.

A Case of Epidural Blood Patch to Treat Headache Due to Spontaneous Intracranial Hypotension -A case report- (경막외 혈액봉합술을 이용한 자연성 두개내 저압성 두통 환자의 치험 1예 -증례 보고-)

  • Park, Soo-Seog;Jang, Yeon;Cho, Eun-Chung;Jee, Seung-Eun;Song, Ho-Kyung;Jung, Sung-Woo
    • The Korean Journal of Pain
    • /
    • v.11 no.2
    • /
    • pp.338-342
    • /
    • 1998
  • Postural headache due to spontaneous intracranial hypotension occurs without any diagnostic lumbar puncture, myelography, cranial or spinal injury, or spinal anesthesia. The clinical characteristics of the syndrome are disappearance of the headache or a notable decrease in its severity with recumbency, the finding of meningeal enhancement and subdural fluid collection on brain MRI, the pleocytosis and the increased CSF protein concentration. We report a case of a 40-year-old woman who exhibited the signs and symptoms of postural headache due to low CSF pressure. Her headache started suddenly at the occiput and radiated to frontal head. Magnetic resonance imaging (MRI) of her brain showed enhancement of the meninges and subdural fluid collection. Intrathecal radionuclide cisternography showed the delayed appearance of the isotope in the cranium and the minimal CSF leak at the left upper thoracic region. Her headache was relieved completely after a lumbar (L2-L3) epidural injection of 12 ml of autologous blood and remained asymptomatic.

  • PDF

Charcot Spinal Arthropathy with Extensive Vertebral Body Destruction and Cerebrospinal Fluid Collection: A Case Report Mimicking Infective Spondylitis (척추체의 광범위한 파괴와 뇌척수액 축적이 동반된 샤르코 척추 관절병증: 감염성 척추염과 유사한 소견을 보이는 증례보고)

  • Cho, Kyu-Jung;Kim, Yeo-Ju;Kim, Young-Tae;Youn, Yung-Hun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.4
    • /
    • pp.348-353
    • /
    • 2020
  • A 68-year-old man presented with a bed sore with pus discharge on lower back. Radiographs showed extensive destruction of the L4 vertebral body. Magnetic resonance imaging (MRI) showed fluid collection with an enhanced wall at the defect of the L4 vertebral body extending into both psoas muscles. The primary diagnosis was neuropathic spondylopathy, but infective spondylitis was not ruled out. Initially, he was treated with antibiotics for two weeks. A follow-up MRI showed no improvement of the abscess, so surgical exploration was done. Charcot spinal arthropathy resulted in extensive vertebral body destruction that may be similar to infectious spondylitis, particularly in the case with fluid accumulation due to rupture of dura.

Indoor Position Technology in Geo-Magnetic Field (지구 자기장 기반의 Fingerprint 실내 위치추정 방법 연구)

  • Hur, Soojung;Song, Junyeol;Park, Yongwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.1
    • /
    • pp.131-140
    • /
    • 2013
  • Due to the limitations of the existing indoor positioning system depending on the radio wave, at present, it is required to introduce a new method in order to improve the accuracy in indoor environment. Recently, bio-inspired technology has become the future core technology. Thus, this study examined the accurate positioning method applying the abilities that animals with homing instinct measure their position by searching geomagnetic field with the use of their biomagnets. In order to confirm the applicability of geomagnetic field, a new source for indoor positioning, this study separated the constituent materials and building structure and designed the structures that can carry the actual magnetic field sensor and the data collection module. Subsequently, this study investigated the applicability of geomagnetic field as a positioning source by establishing the positioning system of Fingerprint method. In performance evaluation of the positioning system, the geomagnetic strength-based positioning system was similar to or approximately 20 percent higher than the wireless LAN-based positioning system in the buildings with the existing wireless LAN. Thus, in the environment without infrastructure for indoor positioning, the geomagnetic, an independent earth resource, can make it possible to realize the indoor positioning.