• Title/Summary/Keyword: Magnetic array

Search Result 285, Processing Time 0.024 seconds

Analysis and Control Parameter Estimation of a Tubular Linear Motor with Halbach and Radial Magnet Array

  • Jang Seok-Myeong;Choi Jang-Young;Cho Han-Wook;Lee Sung-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.2
    • /
    • pp.154-161
    • /
    • 2005
  • In the machine tool industry, direct drive linear motor technology is an interesting means to achieve high acceleration, and to increase reliability. This paper analyzes and compares the characteristics of a tubular linear motor with Halbach and radial magnet array, respectively. First, the governing equations are established analytically in terms of the magnetic vector potential and two dimensional cylindrical coordinate systems. Then, we derive magnetic field solutions due to the PMs and the currents. Motor thrust, flux linkage and back emf are also derived. The results are shown to be in good conformity with those obtained from the commonly used finite element method. Finally, control parameters are obtained from analytical solutions.

Dynamic Analysis and Control Simulation of the Air-Core PMLSM with Halbach Arrays (Halbach 배열을 갖는 공심형 PMLSM의 동특성 해석)

  • Jang, Seok-Myeong;Chang, Kun-Woo;Lee, Sung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.72-74
    • /
    • 2001
  • This paper deals with a dynamic analysis and a position control for air-core type linear synchronous motor with Halbach array (HA) permanent magnet mover. The primary coils are designed to be air-cored, so the HA-PMLSM don't exist the detent force. The secondary HA array of PMs does not require any ferro-magnetic yoke and excites stronger magnetic flux density and closer to the sinusoids than a conventional PM array.

  • PDF

Development of New Biochip using Magnetic Interaction and Random Fluidic Self-assembly (자기력과 Random Fluidic Self-assembly에 의한 신규 바이오칩의 개발)

  • Choi, Yong-Sung;Kwon, Young-Soo;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.6
    • /
    • pp.615-621
    • /
    • 2004
  • This paper describes a new constructing method of multifunctional biosensor using many kinds of biomaterials. A metal particle and an array was fabricated by photolithographic. Biomaterials were immobilized on the metal particle. The array and the particles were mixed in a buffer solution, and were arranged by magnetic force interaction and random fluidic self-assembly. A quarter of total Ni dots were covered by the particles. The binding direction of the particles was controllable, and condition of particles was almost with Au surface on top. The particles were successfully arranged on the array. The biomaterial activities were detected by chemiluminescence and electrochemical methods.

Development of 3-Dimensional Biochip Using Magnetic Interaction and Self-Assembly (자기력과 self-assembly에 의한 3차원 바이오칩의 개발)

  • Choi, Yong-Sung;Park, Dae-Hee;Kwon, Young-Soo;Tamiya, E.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1909-1911
    • /
    • 2003
  • This research describes a new constructing method of multifunctional biosensor using many kinds of biomaterials. A metal particle and an array was fabricated by photolithographic. Biomaterials were immobilized on the metal particle. The array and the particles were mixed in a buffer solution, and were arranged by magnetic force interaction and self-assembly. A quarter of total Ni dots were covered by the particles. The binding direction of the particles was controllable, and condition of particles was almost with Au surface on top. The particles were successfully arranged on the array. The biomaterial activities were detected by chemiluminescence and electrochemical methods.

  • PDF

Protein Chip Using Magnetic Force (자기력에 의한 단백질칩)

  • Choi, Yong-Sung;Moon, Jong-Dae;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.386-387
    • /
    • 2006
  • This research describes a new constructing method of multifunctional biosensor using many kinds of biomaterials. A metal particle and an array was fabricated by photolithographic. Biomaterials were immobilized on the metal particle. The array and the particles were mixed in a buffer solution, and were arranged by magnetic force interaction and self-assembly. A quarter of total Ni dots were covered by the particles. The binding direction of the particles was controllable, and condition of particles was almost with Au surface on top. The particles were successfully arranged on the array. The biomaterial activities were detected by chemiluminescence and electrochemical methods.

  • PDF

Design of Scan-Capable Fabry Perot Cavity Antenna Using Artificial Magnetic Conductors (인공 자기 도체를 이용한 스캔 가능한 패브리 패롯 공진기형 안테나 설계)

  • Kim, Myong-Gyun;Kim, Jong-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.9
    • /
    • pp.1025-1033
    • /
    • 2012
  • Fabry-Perot cavity(FPC) antennas with artificial magnetic conductor(AMC) surface are designed in order to provide scan capability by $4{\times}1$ array feed inside the cavity. The proposed antenna, excited by $4{\times}1$ thinned array, not only achieve higher directivities but also improve suppression of sidelobe level(SLL) relative to that of the thin array alone. The FPC antenna with the height of a quarter wavelength generate maximum gain of 19 dB, SLL suppression of 14 dB and maximum scan angle of $8^{\circ}$ under the feed phase difference of $90^{\circ}$ at the design frequency of 12 GHz.

Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch (대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : To assess the clinical utility of turbo contrast-enhanced magnetic resonance angiography(CE MRA) in the evaluation of the aortic arch and its major branches and to compare the image quality of CE MRA among different coils used. Materials and Methods : Turbo three-phase dynamic CE MRA encompassing aortic arch and its major branches was prospectively performed after manual bolus IV injection of contrast material in 29 patients with suspected cerebrovascular diseases at 1.0T MR unit. the raw data were obtained with 3-D FISH sequence (TR 5.4ms, TE 2.3ms, flip angle 30, slab thickness 80nm, effective slice thickness 4.0mm, matrix size $100{\times}256$, FOV 280mm). Total data acquisition time was 4. to 60 seconds. We subjectively evaluated the imge quality with three-rating scheme : "good" for unequivocal normal finding, "fair" for relatively satisfactory quality to diagnose 'normal' despite intravascular low signal, and "poor" for equivocal diagnosis or non-visualization of the origin or segment of the vessels due to low signal or artifacts which needs catheter angiography. At the level of the carotid bifurcation, it was compared with conventional 2D-TOF MRA image. Overall image quality was also compared visually and quantitatively by measuring signal-to-noise ratios (SNRs) of the ascending aorta, the innominate artery and both common carotid arteries among the three different coils used(CP body array(n=12), CP neck array(n=9), and head-and-neck(n=8). Results : Demonstration of the aortic arch and its major branches was rated as "good" in 55% (16/29) and "fair" in 34%(10/29). At the level of the carotid bifurcation, image quality of turbo CE MRA was same as or better than conventional 2D-TOF MRA in 65% (17/26). Overall image quality and SNR were significantlygreater with CP body array coil than with CP neck array or head-and-neck coil. Conclusions : Turbo CE MRA can be used as a screening exam in the evaluation of the major branches of the aortic arch from their origin to the skull base. Overall imagequality appears to be better with CP body array coil than with CP neck array coil or head-and-neck coil.

  • PDF

Analytical Prediction for Electromagnetic Characteristics of Tubular Linear Actuator with Halbach Array Using Transfer Relations

  • Jang, Seok-Myeong;Choi, Jang-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.221-230
    • /
    • 2007
  • This paper deals with analytical prediction for electromagnetic characteristics of a tubular linear actuator with Halbach array using transfer relations, namely, Melcher's methodology. Using transfer relations derived in terms of magnetic vector potential and a two-dimensional (2-d) cylindrical coordinate system, this paper derives analytical solutions for magnetic vector potential due to permanent magnets (PMs) and stator winding currents. On the basis of these analytical solutions, this paper also achieves analytical solutions for the magnetic fields distribution produced by PMs, stator windings current and axial thrust. The analytical results are validated extensively by finite element (FE) analyses. In particular, test results such as thrust measurements are given to confirm the analysis. Finally, this paper estimates control parameters using analytical solutions and test results such as thrust, back-emf, inductance and resistance measurements.

A study on Eddy current Magnetic Repulsion System Using Permanent Magnets (영구자석을 이용한 와전류 자기반발식 부상장치에 관한 연구)

  • Sung, H.K.;Jho, J.M.;Kim, B.S.;Cho, H.J.;Kim, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1613-1615
    • /
    • 2005
  • Maglev equipped with permanent magnets on the moving part can be levitated by the magnetic repulsion between Halbach array and conducting plate when this vehicle is running. This paper deals with the fundamental principles of the eddy-current magnetic repulsion system and the force characteristics to the change of the permanent magnet array and conduction bar.

  • PDF

Characteristics of Matrix Type SFCL with $2{\times}3$ Array According to the Trigger Coil and Shunt Resistance ($2{\times}3$구조의 매트릭스형 초전도 한류기의 트리거 코일 및 션트 저항에 따른 특성)

  • Jung, Byung-Ik;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.85-89
    • /
    • 2009
  • We investigated the quench characteristics in accordance with increase of turns number of trigger coil and shunt resistance of matrix-type superconducting fault current limiter (SFCL) with $2{\times}3$ array. The matrix-type SFCL consists of the trigger part to apply magnetic field and the current-limiting part to limit fault current. The fault current limiting characteristics according to the increase of magnetic field and applied voltage were nearly same. This is because the application of magnetic field hasn't an affect on total impedance of the SFCL. When turns number of a reactor increased, the voltage difference between two superconducting units in the current-limiting part according was decreased. The resistance difference generated in two superconducting units was also decreased. Therefore, we confirmed that the differences of the critical behaviors between superconducting units were reduced by application of magnetic field. By this results, we could decide the optimum turns number of reactor to apply magnetic field.