Initial Rotor Position Detection of Single-phase Permanent Magnet Synchronous Motor using Offset Voltage (옵셋 전압을 이용한 단상 영구자석 동기 전동기의 초기 회전자 위치 검출)

  • Hwang, Seon-Hwan;Seo, Sung-Woo;Jung, Tae-Uk
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.622-627
    • /
    • 2019
  • This paper propose an initial rotor position detection method for sensorless operation of a single-phase permanent magnet synchronous motor(SP-PMSM) with asymmetric air-gap. In general, the sensorless control based on back-emf estimation is difficult to estimate the back-emf at the zero and low speed regions. For this reason, an open loop start-up technique is indispensable, and it is also necessary to detect the initial position of the rotor in order to rotate in a certain direction. In this paper, we propose a method to detect rotor polarity by adding offset voltage to high frequency voltage signal based on the magnetic characteristics of SP-PMSM. The validity and usefulness of the proposed algorithm are verified through several experimental results.

EFFECTS OF THE CHANGES OF THE MAGNETIC VOLUME ON THE MAGNETIC FORCES (영구자석의 체적 변화가 자력에 미치는 영향)

  • Jang, Hang-Ik;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.25 no.2 s.49
    • /
    • pp.201-208
    • /
    • 1995
  • Recently, magnetic forces are considered as a method for more efficient tooth movement. The purpose of this study was to evaluate the effects of the changes of the magnetic volume on the magnetic forces. The universal testing machine and the electronic balance were used for the exact measurement of the force with constant air gap. While the magnet was kept same on one side, the magnetic volume of the other side was increased gradually in four manners. In the first group, the thickness was increased by adding same size of the magnets one after another while the thickness was increased by changing with a thicker magnet gradually in the second group. In the third group. the width was increased by adding same size of the magnets while the width was increased by changing with a wider magnet gradually in the last group. The results were as follows : 1. With the increase of the thickness, the magnetic force increased, while the magnetic force decreased with the increase of the width. 2. The magnetic force according to the change of the magnetic volume showed the distribution of the logarithmic function. 3. An originally thick magnet showed larger force than the added magnets although both of them had same volume.

  • PDF

A Study on the Design of the Flywheel Energy Storage Device to Store the Regenerative Energy (회생에너지 저장용 플라이휠 에너지 저장 장치 설계에 관한 연구)

  • Lee, Jun-Ho;Park, Chan-Bae;Lee, Byeong-Song
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.1045-1052
    • /
    • 2013
  • In this study we deal with design procedures for the flywheel energy storage system that has the capacity to store the regenerative energy produced from the railway vehicles. The flywheel energy storage system (FESS) stores the regenerative electrical energy into the high speed rotational flywheel, by conversion the electrical energy into the mechanical rotational energy. Thus the FESS is composed of the energy conversion components, such as the motor and generator, mechanical support components, such as the rotational rotor, the magnetic bearings to support the rotor, and the digital controller to control the air gap between the rotor and the magnetic bearings. In this paper the design procedures for the rotor operating at the rigid mode and the magnetic bearings to support the rotational rotor without contact are presented.

A Study on Improvement of Operation Efficiency of Magnetic Levitation Train Using Linear Induction Motor

  • Park, Sang Uk;Zun, Chan Yong;Park, Doh-Young;Lim, Jaewon;Mok, Hyung Soo
    • International Journal of Railway
    • /
    • v.9 no.2
    • /
    • pp.41-45
    • /
    • 2016
  • In this paper, a study on the efficiency improvement of the magnetic levitation train using the LIM (Linear Induction Motor) was presented. The maglev train has the advantage of being environmentally friendly since much less noise and dust is produced. However, due to structural limitation, compared to a rotating induction motor, linear induction motor, the main propulsion engine of the maglev train has a relatively greater air gap and hence has the lower operation efficiency. In this paper, the relationship between the operating condition of the train and the slip frequency has been investigated to find out the optimum slip frequency that might improve the efficiency of the magnetic levitation train with linear induction motor. The slip frequency is variable during the operation by this relationship only within a range that does not affect the levitation system of the train. After that, the comparison of the efficiency between the conventional control method with the slip frequency fixed at 13.5[Hz] and the proposed method with the slip frequency variable from 9.5[Hz] to 6.5[Hz] has been conducted by simulation using Simplorer. Experiments of 19.5[ton] magnetic levitation trains owned by Korea Institute of Machinery and Materials were carried out to verify the simulation results.

A Coupled Circuit and Field Analysis of a Stand-Alone Permanent-Magnet Synchronous Generator with Inset Rotor

  • Chan T. F.;Yan Lie-Tong;Lai L. L.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.3
    • /
    • pp.253-257
    • /
    • 2005
  • By using a coupled circuit, time-stepping, two-dimensional finite element method (2-D FEM), the performance of a stand-alone permanent-magnet synchronous generator (PMSG) with inset rotor can be computed without involving the classical two-axis model. The effects of interpolar air gap length and armature resistance on the load characteristics are investigated. It is shown that the interpolar flux density, and hence the amount of voltage compensation, is affected by magnetic saturation. Validity of the coupled circuit and field analysis is confirmed by experiments on a prototype generator. The machine exhibits an approximately level load characteristic when it is supplying an isolated unity-power-factor load.

Design and Analysis of an Axial Flux Magnet for Magnetic Levitation System. (자기부상용 증축형 전자석의 설계 및 특성 해석)

  • Kang, Do-Hyun;Shin, Pan-Seok;Kim, Yong-Joo;Cho, Yun-Hyun;Park, Do-Young
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.63-67
    • /
    • 1990
  • An axial flux magnet for a magnetic levitation system is designed and analysed by finite element simulations. The results are compared with those of experiment in order to verify the analysing method. Lift force, air gap flux density and temperature characteristics of the magnet showed fairly good agreement with each other.

  • PDF

A 3 Dimensional Characteristic Analysis of SLIM by the 2-D Finite Element Method (2차원 유한요소법에 의한 SLIM의 3차원적 특성 해석)

  • Cho, Yun-Hyun;Kim, Yong-Joo;Shin, Pan-Seok;Kang, Do-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.37-42
    • /
    • 1990
  • In order to obtain optimal design criteria and operating parameters, a Single-sided Linear Induction Motor (SLIM) is analysed by using a 2-D finite element method with magnetic and current vector potential. In the analysing procedures, the governing equation is derived from Maxwell's equation combined with the magnetic vector potential. As a forcing term, 3-phase voltage source is employed using the Kirchhoff's voltage law in order to look into effects of the unbalanced 3-phase currents and air gap flux density. Also, 2ndary eddy current distribution, longitudinal end and transverse edge effects are in turns visualized by flux lines in 3 different analysing planes as functions of frequency and input power.

  • PDF

Development of control algorism and magnetic analysis of a MR damper (작동기 구조해석 및 제어알고리즘 개발)

  • Park, C.S.;Song, S.S.;Lee, H.J.;Lee, J.J.;Hong, S.H.;Jo, H.M.
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.254-256
    • /
    • 2008
  • In recent Year were many devices and facilities developed and manufactured. For guarantee of the property of the devices and facilities needs Vibration protecting Technique and the Technique will be developed more and more. Magneto-Rheological damper is one of the nice devices for reducing of Vibration. In this paper magnetic properties of a MR-damper which is developed for reducing of vibration in display manufacture devices will be analysed at variation different air-gap length and current.

  • PDF

A Study on the Effect of the Magnetic Flux Feedback on Open Loop Characteristics in a Magnetic Suspension System (자기부상 시스템에서 자속 궤환이 Open-Loop 특성에 미치는 영향에 대한 연구)

  • Kim, Yong-Kyu;Lee, Jun-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.181-186
    • /
    • 2006
  • 본 논문에서는 자속 궤환을 포함하는 자기부상 시스템의 open-loop 특성에 대해서 다룬다. 훌륭한 외란 억제 특성을 포함하고 파라메타 변동에 대해서 둔감한 제어기를 설계하기 위해서 자속 궤환을 이용하는 것이 효과적일 수 있다. 적절한 센서에 의해서 측정 가능한 자속은 전류와 공극의 시간 변화에 대해서 선형적인 관계를 가지고 있으며, 자속의 궤한은 자기 부상시스템이 본질적으로 갖고 있는 전기적 엑츄에이터와 기계적 플랜트 사이의 간섭에 의해서 발생하는 비선형성을 감소시키는 역할을 한다. 모의시험 결과를 통해서 자속의 궤환이 자기부상 시스템의 부하변동에 대해서 open-loop 성능 향상에 효과적임을 보인다.

  • PDF

Analysis of the Electromagnetic Clutch for Emergency Power Generator (비상발전기용 전자클러치의 자계해석)

  • Jeon, Mun-Ho;Kim, Chang-Eob
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.111-116
    • /
    • 2011
  • This paper deals with the electromagnetic clutch which stop the generator at emergency by using the engine power of generator. The electromagnetic field was analyzed using Flux-2d program with different conditions : voltage, air gap, coil locations. As a result, the maximum magnetic flux density of electromagnetic clutch occurred between the coil and wheel : 0.27[T], 0.41[T] at 12[V], 24[V]. The maximum flux density was at the center location of the coil.