• Title/Summary/Keyword: Magnetic Field Strength

Search Result 395, Processing Time 0.023 seconds

Characterization of Surface Damage and Contamination of Si Using Cylindrial Magnetron Reactive Ion Etching

  • Young, Yeom-Geun
    • Korean Journal of Materials Research
    • /
    • v.3 no.5
    • /
    • pp.482-496
    • /
    • 1993
  • Radiation damage and contamination of silicons etched in the $CF_4+H_2$ and $CHF_3$ magnetron discharges have been characterized using Schottky diode characteristics, TEM, AES, and SIMS as a function of applied magnetic field strength. It turned out that, as the magnetic field strength increased, the radiation damage measured by cross sectional TEM and by leakage current of Schottky diodes decreased colse to that of wet dtched samples especially for $CF_4$ plasma etched samples, For $CF_4+H_2$and $CHF_3$ etched samples, hydrogen from the plasmas introduced extended defects to the silicon and this caused increased leakage current to the samples etched at low magnetic field strength conditions by hydrogen passivation. The thickness of polymer with the increasing magnetic field strength and showed the minimum polymer residue thickness near the 100Gauss where the silicon etch rate was maximum. Also, other contaminants such as target material were found to be minimum on the etched silicon surface near the highest etch rate condition.

  • PDF

The Control of the Magnetic Field around Down Conductors (인하도선 주변에서 발생하는 자장의 억제)

  • Lee, Bok-Hee;Kang, Sung-Man;Lee, Seung-Chil;Eom, Ju-Hong;Lee, Kyoung-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.216-218
    • /
    • 2001
  • This paper deals with the control of magnetic field around the down conductor of lightning protection systems. The magnetic field strength in the vicinity of down conductor is shown to drop off rapidly with distance from the down conductor and is reversely proportional to the number of down conductor. Also the magnetic field strength is decreased in the structures as the down conductor is installed with the symmetrical arrangement, and it is zero at the center of symmetry. The magnetic field strengths for the symmetrical arrangement of two down conductors are less than one half compared with that for a down conductor. A proper arrangement of down conductor can reduce or cancel the magnetic field in a restricted place where information-oriented and computerized facilities are densely installed.

  • PDF

A Study on the Engineering Properties of Grout Materials Using a Magnetic Field Treated Water (자화수를 사용한 주입재의 공학적 특성에 관한 연구)

  • Chun, Byung-Sik;Park, Doo-Hee;Yang, Hyung-Chil;Jung, Jong-Ju;Lee, Sang-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1195-1203
    • /
    • 2006
  • Water that is treated by passing through a magnetic field of certain strength is called Magnetic Field Treated Water(MFTW). Previous research indicate that use of MFTW can save 5% of cement dosage, decrease bleeding of concrete, and improve resistance to freezing. The reason why MFTW can improve characteristics of concrete can be explained by the molecular structure of water. Magnetic force can break apart water clusters into single molecules or smaller ones, therefore, the activity of water is improved. While hydration of cement particles is in progress, the MFTW can penetrate the core region of cement particles more easily. Hence, hydration takes place more efficiently which in turn improves concrete compressive strength. Test results demonstrate that the compressive strength of the sodium silicate cement grout homogel increases by approximately 20 - 50% by using the MFTW.

  • PDF

Fabrication and magnetic properties of hexagonal BaFe12O19 ferrite obtained by magnetic-field-assisted hydrothermal process

  • Zhang, Min;Dai, Jianming;Liu, Qiangchun;Li, Qiang;Zi, Zhenfa
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1426-1430
    • /
    • 2018
  • High magnetic field effects on the microstructure and magnetic properties of $BaFe_{12}O_{19}$ hexaferrites synthesized hydrothermal method have been investigated. The obtained results indicate that the lattice constant decreases gradually as the magnetic field strength increases, which may be attributed to the lattice distortion resulted from the high magnetic field. Polycrystalline $BaFe_{12}O_{19}$ samples prepared under magnetic field strength at zero and 5 T are single phase. It is found that application of external magnetic field during synthesis can induce orientated growth of the hexaferrite crystals along the easy magnetic axis. The magnetic properties can be effectively regulated by an application of high magnetic fields. It is observed that the $BaFe_{12}O_{19}$ prepared under a 5 T magnetic field exhibits a higher room-temperature saturation magnetization (66.3 emu/g) than that of the sample (43.6 emu/g) obtained without magnetic field. The results can be explained as the enhanced crystalline, improvement of $Fe^{3+}$ ions occupancy and the oriented growth induced by the external magnetic field. The growing orientation of particles gives rise to increased coercivity due to the enhancement in shape anisotropy. It is expected that an application of magnetic field during the formation of magnetic nanoparticles could be a promising technique to modify magnetic properties with excellent performance.

The study to flat-type generate of magnetic field with CW (Continue wave) frequency and AM (Amplitude modulation) frequency

  • Shin, Gi Won;Kang, Chang Ho;Lee, Min Jun;Yang, Sung Jae;Lee, Hyuk Ho;Hong, Hyun Bin;Jo, Tae Hoon;Kwon, Gi Chung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.139.2-139.2
    • /
    • 2015
  • In this study, We applied the magnetic field that has CW frequency and AM frequency to heating magnetic nano powder. For this experiment, We set up the devices flat-type magnetic field generator with CW frequency and AM frequency. We supplied the current to encircling coil by adjusting the power of generating of magnetic field device for AC voltage through Slidacs and using way of LC resonance circuit and SMPS(Switching Mode Power Supply). Above the encircling coil, We covered the circular flat insulator like glass. And we located the well plate containing the magnetic nano powder liquor above the circular flat insulator and exposed the magnetic field to this well plate. Using the flat-type magnetic field generator with CW and AM frequency and the magnetic field measurement sensor(Magnetic pick up coil or Hall sensor), We measured the strength of the magnetic field of circular flat insulator's surface in each position. The temperature of the magnetic nano powder in the well plate was quantitatively measured by the magnetic field strength through the Fluoroptic thermometer.

  • PDF

An Invesitgation of Pre-service Teachers Understandings on Magnet (초등학교 예비교사들의 자석에 관한 이해도 조사)

  • 이형철;정승호
    • Journal of Korean Elementary Science Education
    • /
    • v.23 no.2
    • /
    • pp.141-151
    • /
    • 2004
  • Pre-service teachers' understandings on magnet was investigated through the questionnaire method. The questionnaire was composed of 17 questions about the strength of magnet, the magnetized object and the direction of magnetic field around magnet. In this investigation study, 225 pre-service teachers were selected through random sampling method, who were sophomores in a National University of Education. The formation rate of the scientific conceptions on the strength of magnet was 30.3% and that on the direction of magnetic field around magnet was 53.9%. The average formation rate of scientific conception of all questions on magnet was 44.13%, which doesn't seem to be high as expected. It shows that many of subjects of the questionnaire don't understand fully the concept of moleclar magnet model and the superposition effects of magnetic field around magnet. The formation rate of the scientific conception on magnet of females who took courses in sciences in high school were higher than that of females who took courses in arts in high school, which had meaningful difference (p<.05).

  • PDF

A Method of Prediction and Analysis of Electromagnetic Interference (EMI) in Wireless Power Transfer System Operating at 13.56 MHz (13.56 MHz 무선 에너지 전송 시스템의 효율적인 전자파 장해(EMI) 예측 및 분석 방법)

  • Shim, Hyun-Jin;Park, Jong-Min;Nam, Sangwook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.9
    • /
    • pp.873-882
    • /
    • 2013
  • The effective way of estimation and analysis of EMI(Electromagnetic Interference) in Wireless Power Transfer System operating at 13.56 MHz is proposed. In this paper methodology of driving magnetic field strength and electric loop current of two antennas which are in free space and on PEC plane using image theory and duality is proposed. Perfect electric conductor(PEC) is planar, infinite in extent, and perfectly conducting plane. And we will refer it as PEC plane. A equivalent circuit model is used to analyze. Using this theoretical analysis, we can derive maximum magnetic field strength of the far-field region numerically using measured data of near-field maximum magnetic field strength. The experimental results using commercial numerical simulation tool are in agreement with the theoretical results. Also, using the derivation of maximum magnetic field strength in the far-field region, we can easily estimate the maximum allowable power dissipation that meets EMI regulations.

Dynamic Properties of Squeeze Type Mount Using MR Fluid (MR 유체를 이용한 스퀴즈모드형 마운트의 동특성)

  • 안영공
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.6
    • /
    • pp.490-495
    • /
    • 2003
  • This paper presents investigation of damping characteristics of squeeze mode type MR (magneto-rheological) mount experimentally. Since damping property of the MR fluid is changed by variation of the applied magnetic field strength, squeeze mode type MR mount proposed in the study has variable damping characteristics according to the applied magnetic field strength. In the present work, the performance of the mount was experimentally Investigated according to the magnetic field strength and exciting frequencies. The experimental results present that the MR mount can effectively reduce the vibration in a wide range of frequency by controlling the applied electromagnetic field strength. Viscous damping and stiffness coefficients of the MR mount tend to be changed according to the variation of the applied currents in this study and MR effect is reduced by increasing exciting frequency.

MAGNETOSTATIC MODELS OF STARSPOTS

  • YUN HONG SIK;PARK JONG-SUH
    • Journal of The Korean Astronomical Society
    • /
    • v.26 no.2
    • /
    • pp.89-98
    • /
    • 1993
  • Magnetostatic models of starspots of late type main sequence stars$(G5V\~K5V)$ have been constructed to investigate their physical characteristics by using the similarity law suggested by Schluter and Temesvary(1958) and later employed by Deinzer(1965) and Yun(1968). The starspots are assumed to be single, circular and in horizontal magnetostatic equilibrium. In the present study we considered only those model spots whose area covers less than $12\%$ of the entire stellar surface as suggested by observations. The computed surface field strength of our model spots ranges from $10^3$\;to\;several\;10^3$ gauss and their magnetic flux is found to be $10\~100$ times that of sunspots. The field strength is sensitive to spectral type, which increases with later spectral type. In contrast to the field strength, the area of starspots depends strongly on the total magnetic flux. Finally, it is noted that the computed field strength of model spots belonging to $G0V\~G5V$ falls below the equipartition field strength at their parent stellar surface unless the coverage is less than $2\%$. This suggests that the observed spot on $G0V\~G5V$ stars is likely to be a group of small starspots.

  • PDF

Fundamental Background for 3T MRI/MRS

  • Choe, Bo-Young
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.47-49
    • /
    • 2002
  • At present, the trend of magnetic field strength in MRI system is dramatically changing. In early 70, the only low field (<0.5T) was developed. It was technically difficult to develop the high field system. At that time, people believed that the fine MR imaging could not be obtained in the high field MR system due to the magnetic susceptibility effect. However, 1.5T system was evolved at the end of 80, and used for clinical usage. Thus, it was proved that the signal to noise ratio (SNR) could be greatly contribute to enhance the image quality. And, the results of functional MRI and MR spectroscopy could be improved in the higher field MR system. So, 8T system was eventually developed in Ohio State University Hospital at the end of 90. Therefore, there is no doubt that the system with the ultra high magnetic field strength will be developed near future in 21 century.

  • PDF