• 제목/요약/키워드: Magnetic Field Strength

검색결과 395건 처리시간 0.025초

Effect of turbulence driving and sonic Mach number on Davis-Chandrasekhar-Fermi method

  • Yoon, Heesun;Cho, Jungyeon
    • The Bulletin of The Korean Astronomical Society
    • /
    • 제44권1호
    • /
    • pp.44.1-44.1
    • /
    • 2019
  • Davis-Chandrasekhar-Fermi (DCF) method is a tool that is widely used to obtain the strength of the mean magnetic field projected on the plane of the sky. When there are independent eddies along the line of sight, the variation of polarization angle will decrease by the averaging effect. Therefore, the measured strength of the magnetic field can be overestimated. Cho & Yoo (2016) proposed a modified DCF method considering such effect. By using this, we quantitatively compared the results from the conventional DCF and the modified DCF methods for various sonic Mach numbers and driving schemes (the solenoidal and compressive driving). Here, we present that the modified DCF method does not show a strong dependence on the sonic Mach number or driving schemes either, while the conventional DCF method depends on the sonic Mach number for the compressive driving scheme.

  • PDF

LINEAR ANALYSIS OF PARKER-JEANS INSTABILITY WITH COSMIC-RAY

  • KUWABARA TAKUHITO;KO CHUNG-MING
    • Journal of The Korean Astronomical Society
    • /
    • 제37권5호
    • /
    • pp.601-603
    • /
    • 2004
  • We present the results of the linear analysis for the Parker-Jeans instability in the magnetized gas disks including the effect of cosmic-ray diffusion along the magnetic field lines. We adopted an uni-formly rotating two temperature layered disk with a horizontal magnetic fields and solved the perturbed equations numerically. Fragmentation of gases takes place and filamentary structures are formed by the growth of the instability. Nagai et al. (1998) showed that the direction of filaments being formed by the Parker-Jeans instability depends on the strength of pressure outside the unperturbed gas disk. We found that at some range of external pressures the direction of filaments is also governed by the value of the diffusion coefficient of CR along the magnetic field lines k.

In situ analysis of capturing dynamics of magnetic nanoparticles in a microfluidic system

  • Munir, Ahsan;Zhu, Zanzan;Wang, Jianlong;Zhou, H. Susan
    • Smart Structures and Systems
    • /
    • 제12권1호
    • /
    • pp.1-22
    • /
    • 2013
  • Magnetic nanoparticle based bioseparation in microfluidics is a multiphysics phenomenon that involves interplay of various parameters. The ability to understand the dynamics of these parameters is a prerequisite for designing and developing more efficient magnetic cell/bio-particle separation systems. Therefore, in this work proof-of-concept experiments are combined with advanced numerical simulation to design and optimize the capturing process of magnetic nanoparticles responsible for efficient microfluidic bioseparation. A low cost generic microfluidic platform was developed using a novel micromolding method that can be done without a clean room techniques and at much lower cost and time. Parametric analysis using both experiments and theoretical predictions were performed. It was found that flow rate and magnetic field strength greatly influence the transport of magnetic nanoparticles in the microchannel and control the capturing efficiency. The results from mathematical model agree very well with experiments. The model further demonstrated that a 12% increase in capturing efficiency can be achieved by introducing of iron-grooved bar in the microfluidic setup that resulted in increase in magnetic field gradient. The numerical simulations were helpful in testing and optimizing key design parameters. Overall, this work demonstrated that a simple low cost experimental proof-of-concept setup can be synchronized with advanced numerical simulation not only to enhance the functional performance of magneto-fluidic capturing systems but also to efficiently design and develop microfluidic bioseparation systems for biomedical applications.

Giant Magnetoresistance Phenomenon under the Double Magnetic Fields (이중자장하에서 거대자기저항 현상)

  • 송용진;주승기
    • Journal of the Korean Magnetics Society
    • /
    • 제4권4호
    • /
    • pp.340-346
    • /
    • 1994
  • Change in the electrical resistance of artificial superlattice under two magnetic fields-the main and the secondary magnetic field-has been studied with respect to each magnetic field strength in (200) textured Co/Cu artificial superlattice. When the two magnetic fields were applied in the same direction, lateral shift of the magnetoresistance curve occurred, while splitting phenomenon of the maximum resistance appeared when the two magnetic fields were applied at the right angle. When the angle between the two magnetic fields became $45^{\circ}$ shifting as well as splitting occurred in the magnetoresistance curve. This magnetoresistance behavior with double magnetic fields in the artificial superlattices could be explained with the macroscopic spin alignment model newly suggested in this work.

  • PDF

Morning-afternoon asymmetry of geosynchronous magnetic field variations during geomagnetic sudden commencements

  • Park, Jong-Sun;Kim, Khan-Hyuk;Sung, Suk-Kyung;Lee, Dong-Hun
    • Bulletin of the Korean Space Science Society
    • /
    • 한국우주과학회 2010년도 한국우주과학회보 제19권1호
    • /
    • pp.40.2-40.2
    • /
    • 2010
  • It has been reported that geosynchronous magnetopause crossings are more frequently observed in the prenoon sector than in the postnoon sector, indicating a dawn-dusk magnetopause asymmetry during extreme solar wind conditions. Motivated by these observations, we investigate geosynchronous magnetic field variations normalized to SYM-H when sudden commencements (SC) are observed on the ground. From a statistical analysis of the geosynchronous magnetic field responses to SC events from 1997 to 2006, we found that the normalized SC amplitude at geosynchronous orbit is larger in the morning sector than in the afternoon sector. In order to examine if this morning-afternoon asymmetry at geosynchronous orbit occurs only during disturbed geomagnetic conditions, we compared the geosynchronous magnetic field strength obtained in the morning and afternoon during undisturbed intervals (Kp < 3). We found that the asymmetry appears under undisturbed geomagnetic conditions and it is not due to solar wind aberration. This indicates that the morning-afternoon asymmetry was not strongly affected by changes in solar wind condition. Using solar wind data, we discuss what causes the morning-afternoon asymmetry at geosynchronous orbit.

  • PDF

Properties of transient horizontal magnetic fields and their implication to the origin of quiet-Sun magnetism

  • Ishikawa, Ryohko
    • The Bulletin of The Korean Astronomical Society
    • /
    • 제37권1호
    • /
    • pp.84.1-84.1
    • /
    • 2012
  • Recent spectropolarimetric observations with high spatial resolution and high polarization sensitivity have provided us with new insight to better understand the quiet-Sun magnetism. This talk is concerned with the ubiquitous transient horizontal magnetic fields in the quiet-Sun, as revealed by the Solar Optical Telescope (SOT) on board Hinode satellite. Exploiting the SOT data with careful treatment of photon noise, we reveal the enigmatic properties of these horizontal magnetic fields such as lifetime, size, position in terms of granular structure, occurrence rate, three-dimensional structure, total magnetic flux, field strength distribution, relationship with the meso- and super-granulations and so on. Based on these observational consequences, we conjecture that the local dynamo process, which takes place in a relatively shallow layer with the granular size, produces these transient horizontal magnetic fields and that these horizontal magnetic fields contribute to the considerable amount of quiet-Sun magnetic fields. We also estimate the magnetic energy flux carried by these horizontal magnetic fields based on the statistical data, and find that the total magnetic energy is comparable to the total chromospheric and coronal energy loss, implying their important role for the chromospheric heating and dynamism.

  • PDF

Study on the two-dimensional Formation Control of Free Surface of Magnetic Fluid by Electromagnetic Force (전자기력에 의한 자성유체의 2차원 자유표면 형상 제어에 관한 연구)

  • 안창호;지병걸;이은준;박명관
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.979-982
    • /
    • 2003
  • In this study, because of change in electromagnetic force, deformation of the free surface motion of a magnetic fluid is changed. Deformation of the free surface motion of a magnetic fluid for the change in electromagnetic force is discussed and carried out theoretically and experimentally on the basis of Rosensweig Ferrohydrodynamic Bernoulli Equation. Objective of this study explicates free surface motion by electromagnetic force and planes to designed controller. To control free surface of magnetic fluid, it embody designed two-dimensional free surface form of magnetic fluid. By using this characteristics, they applied to oscillator for surface control, flow control, boundary layer control. Strength of magnetic field and height of free surface of magnetic fluid measure as a hall-effect sensor. As performing height control of magnetic fluid, the result will be presented possibility of free surface deformation control.

  • PDF

Detection of Magnetic Nanoparticles in Tissue Using Magneto-Motive DP-OCT

  • Oh, Jung-Hwan;Lee, Ho;Kim, Jee-Hyun
    • Journal of the Optical Society of Korea
    • /
    • 제11권1호
    • /
    • pp.26-33
    • /
    • 2007
  • We demonstrate the capability of differential-phase optical coherence tomography (DP-OCT) to detect superparamagnetic iron oxide (SPIO) nanoparticles taken up by liver parenchymeal macrophages (Kupffer cells). We apply an external time-varying high-intensity focused magnetic field. Our experiments demonstrate a novel diagnostic modality to detect macrophages that have taken up SPIO nanoparticles. Magnetic force acting on the nanoparticles was varied by applying a sinusoidal current to a solenoid containing a conical iron core that substantially increased and focused the magnetic field strength ($B_{max}$ = 2 Tesla). $ApoE^{-/-}$ mice were sacrificed 2 days post intravenous injections of different SPIO doses (1.0, and 0.1 mmol Fe/kg body weight). Livers of $ApoE^{-/-}$ mice with and without injection of SPIO nanoparticles were investigated using DP-OCT, which detects tissue movement with nanometer resolution. Frequency response of iron-laden liver movement was twice the stimulus frequency. Movement was not observed in livers of control mice. Results of our experiments indicate DP-OCT is a candidate methodology to detect tissue based macrophages containing SPIO nanoparticles excited by an external focused magnetic field.

The Electro-Magnetic Susceptibility Test Method of a Road Vehicle Considering the Field Uniformity (전계의 균일성을 고려한 자동차의 전자파 내성시험 방법에 관한 연구)

  • Bae, Min-Gwan;Shin, Jae-Kon;Yong, Gee-Joong;Woo, Hyun-Gu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • 제18권4호
    • /
    • pp.84-91
    • /
    • 2010
  • Owing to revolutionary developments in automobile technologies, a variety of advanced vehicles - hybrid vehicle, hydrogen fuel-cell vehicle, electric vehicle, etc. - emerges recently. The safety is getting more important for developing automobiles. The electro-magnetic compatibility has to be assured, since those advanced vehicles are equipped with various new electronic systems. Electro-magnetic compatibility tests, in general, consist of an EMI(electro-magnetic interference) test and an EMS (electro-magnetic susceptibility) test. We investigated the susceptibility test method suggested in KMVSS (Korean Motor Vehicle Safety Standard) as the EMS test method. A series of experiments results that the above test method should be partially revised to comply with a Korean governmental standard method. In this paper, the some directions of modifications are presented to enhance the quality of the above EMS test method.