• Title/Summary/Keyword: Magnetic Field Reduction

Search Result 186, Processing Time 0.034 seconds

The magnetic properties of the systems of the ultra-fine particles

  • Perov, N.S;Sudarikova, N.Yu.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.17-17
    • /
    • 2002
  • The magnetic effects connected to finite-size of the particles become dominant at transition of particles in region several nanometers and less [1]. At reduction of atom numbers in magnetic cluster (tens or hundreds atoms), along the classical features, essential appear the quantum phenomena resulting in spin transformation of magnetic structure, both with reduction of the size and at applying of an external magnetic field. (omitted)

  • PDF

Stress Wave Reduction of Structures Using MR Inserts (MR Insert를 이용한 구조물의 응력파 저감)

  • 강병우;김재환;최승복;김경수
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.4
    • /
    • pp.71-77
    • /
    • 2001
  • In this paper, stress wave propagation characteristics of MR(Magneto-rheological) inserts are experimentally investigated. Generally, stress waves of structures such as warships or submarines are induced by shock waves from underwater explosion. Their fatal effects on the shipboard equipments or structures damage the performance of warships. But, such a problem can be solved by controlling the stress waves propagating through structures by means of MR inserts. MR insert consists of two aluminum layers and MR fluid filled in between. Two piezoceramic disks are embedded on the host plate as a transmitter and a receiver of stress waves. Pulse waves are generated by the transmitter and they reach to the receiver through the MR insert. Permanent magnet and magnetic coil are used to produce magnetic field at the MR insert. In the presence of magnetic field, MR particles are arranged in chains parallel to the magnetic field such that the transmitted stress waves are reduced. Attenuation of stress waves is experimentally investigated.

  • PDF

Magnetic separation device for paramagnetic materials operated in a low magnetic field

  • Mishima, F.;Nomura, N.;Nishijima, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.3
    • /
    • pp.19-23
    • /
    • 2022
  • We have been developing a magnetic separation device that can be used in low magnetic fields for paramagnetic materials. Magnetic separation of paramagnetic particles with a small particle size is desired for volume reduction of contaminated soil in Fukushima or separation of iron scale from water supply system in power plants. However, the implementation of the system has been difficult due to the needed magnetic fields is high for paramagnetic materials. This is because there was a problem in installing such a magnet in the site. Therefore, we have developed a magnetic separation system that combines a selection tube and magnetic separation that can separate small sized paramagnetic particles in a low magnetic field. The selection tube is a technique for classifying the suspended particles by utilizing the phenomenon that the suspended particles come to rest when the gravity acting on the particles and the drag force are balanced when the suspension is flowed upward. In the balanced condition, they can be captured with even small magnetic forces. In this study, we calculated the particle size of paramagnetic particles trapped in a selection tube in a high gradient magnetic field. As a result, the combination of the selection tube and HGMS (High Gradient Magnetic Separation-system) can separate small sized paramagnetic particles under low magnetic field with high efficiency, and this paper shows its potential application.

Ligand Field Approach to $4d^{1}$ Magnetism Based on Intermediate Field Coupling Scheme

  • 최진호;김종영
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.9
    • /
    • pp.976-981
    • /
    • 1997
  • The magnetic susceptibilities of molybdenum ions with 4d1 electronic configuration in the octahedral crystal field were calculated on the basis of ligand field theory. The experimental magnetic susceptibilities for molybdenum ions, which are stabilized at the octahedral site in the perovskite lattice of Ba2ScMoⅤO6 and Sr2YMoⅤO6, were compared with the theoretical ones. We have tried to fit their temperature dependence of magnetic susceptibility with ligand field parameters, spin-orbit coupling constant ζSO, and orbital reduction parameter κ according to intermediate field coupling and strong field theory. Strong field coupling theory could not explain experimental curves without unrealistically large axial ligand field, since it ignores the mixing up between different state via spin-orbit interaction and ligand field. On the other hand, the intermediate field coupling theory could successfully reproduce experimental data in octahedral and trigonal ligand field. The fitting result demonstrates not only the fact that spin-orbit interaction is primarily responsible for the variation of magnetic behavior but also the fact that effective orbital overlap, enhanced by cubic crystal structure, reduces significantly orbital angular momentum as indicated by κ parameter.

Study on Variation of Depth Dose Curves by the Strong Magnetic Fields : Monte Carlo Calculation for 10 MV X-rays (강자기장에 의한 깊이선량율(PDD) 변화에 관한 연구 : 10 MV 광자선에 대한 몬테칼로 계산)

  • 정동혁;김진기;김정기;신교철;김기환;김성규;김진영;오영기;지영훈
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.234-239
    • /
    • 2003
  • We examined the variation of percent depth dose (PDD) curves for 10 MV X-rays in the presence of magnetic fields. The EGS4 Monte Carlo code was applied and modified to take account of the effect of electron deflection under magnetic field was used. We defined and tested DI (dose improvement) and DR (dose reduction) to describe variation of PDD curves under various magnetic fields. For a magnetic field of 3 T applied at the depth region of 5-10 cm and field size of 10${\times}$10 $\textrm{cm}^2$, the DI is 1.56 (56% improvement) and DR is 0.68 (32% reduction). We explained the results from the Lorentz law and the concept of electron equilibrium. We suggested that the dose optimization in radiotherapy can be achieved from using the characteristics of dose distributions under magnetic fields.

  • PDF

Optimal Angle Error Reduction of Magnetic Position Sensor by 3D Finite Element Method

  • Kim, Ki-Chan
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.454-459
    • /
    • 2013
  • This paper deals with an optimal angle error reduction method of magnetic position sensor using hall effect elements. The angle detection simulation for the magnetic position sensor is performed by 3 dimensional finite element method and Taguchi method, one of the design of experiments. The magnetic position sensor is required to generate ideal sine and cosine waveforms from its hall effect elements according to rotation angle for precise angle information. However, the output signals are easy to include harmonics due to uneven magnetic field distribution from permanent magnet in the air-gap in the vicinity of hall effect elements. For the Taguchi method, three design parameters related to position of hall effect elements and shape of back yoke are selected. The characteristics of optimal magnetic position sensor are compared with those of original one in terms of simulation as well as experiment. Finally, the performances of the motor adopting original model and optimal model are represented for the purpose of verification of motor performance due to signals from magnetic position sensor.

Reduction Characteristics on Perpendicular Magnetization Loss in Transposed Stacking Conductor of Striated YBCO CC (분할형 YBCO CC들을 전위한 적층도체의 수직 자화손실 저감 특성)

  • Lee, J.K.;Byun, S.B.;Han, B.W.;Park, S.H.;Choi, S.J.;Kim, W.S.;Park, C.;Choi, K.D.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.15-19
    • /
    • 2009
  • Recently, it is proposed to make striations on the YBCO coated conductor and to transpose each other as one of the solutions to decrease the perpendicular magnetization loss. For large power application using HTS, the stacked conductor packing the YBCO coated conductors should be used because single conductor is limited in flowing of demanded large current. In this paper, we research the affect of the striation and continuously transposed stacking geometry on the magnetization loss in perpendicularly exposed magnetic field. Several short samples having different number of striation and continuously transposed stack are prepared and tested in perpendicularly exposed magnetic field for the magnetization loss characteristics. The magnetization loss of striated sample was lower than sample without striation. The reduction effect on magnetization loss by the striation is obviously appeared in higher field and lower number of stack and decreased as increasing the transposed stacking number. Also, the reduction effect by transposed stack is obviously appeared in lower field at lower number of striation and isn't appeared at higher striation number and higher magnetic field.

Feasibility Study of Squeal Noise Reduction using Magneto-rheological Elastomer (자기유변탄성체를 이용한 스퀼 소음 저감 타당성 연구)

  • Song, HyukGeun;Lee, Chul-Hee
    • Tribology and Lubricants
    • /
    • v.36 no.5
    • /
    • pp.274-278
    • /
    • 2020
  • This study investigates the possibility of reducing squeal noise generated at the contact point between an elastomer and glass by using the properties of a magneto-rheological elastomer (MRE) whose stiffness changes with the application of a magnetic field. Previously, squeal noise was mainly observed in the unstable section caused by the weakening of friction due to velocity. Previous studies have shown that squeal noise decreases as the stiffness increases. Accordingly, this study is conducted to control the unstable area of the friction curve and to reduce the noise by inducing the stiffness change of the MRE by applying a magnetic field. The friction, vibration, and noise characteristics are measured using a reciprocating friction tester. The frequency ranges of vibration and noise measured with the accelerometer and sound sensor show similar results. When a magnetic field is applied to the MRE, there is significantly lower noise compared with the case without the application of the magnetic field. The average coefficient of friction decreases with the application of the magnetic field. The maximum coefficient of friction increases rapidly at the turning point and decreases when the magnetic field is applied. This shows that the mechanical properties of the MRE change due to the magnetic field, and the noise and friction coefficient also decrease.

MODELING OF A REPULSIVE TYPE MAGNETIC BEARING FOR FIVE AXIS CONTROL INCLUDING EDDY CURRENT EFFECT

  • Ohji, T.;Mukhopadhyay, S.C.;Iwahara, M.;Yamada, S.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.625-629
    • /
    • 1998
  • So far a single-axis controlled repulsive type magnetic bearing system have been designed and fabricated in our laboratory employing the repulsive forces operating between the stator and rotor permanent magnet for levitation. The radial axis is uncontrolled passive one. The higher speed of operation is limited due to the vibration along the uncontrolled axis and the increase of control current due to eddy current interference. This paper will discuss a detailed modeling of the repulsive type magnetic bearing system for five axis control including the eddy current effect and the method of reduction of eddy current effect. Simulation results using Matlab will be presented.

  • PDF

A Study on Surface Tension Measurement for the Water through Electro-Magnetic Field (전자장을 통과한 물의 표면장력 측정에 대한 연구)

  • 고영하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.7
    • /
    • pp.826-831
    • /
    • 2003
  • The purpose of this study was to measure the surface tension of hard water through electro-magnetic field for investigating the effect of electro-magnetic water treatment. The maximum reduction of surface tension was 8% comparing to the no treatment case. When the flow velocity through the permanent magnetic device (PMD) was 6.3 m/s, sample of hard water had the minimum surface tension.