• Title/Summary/Keyword: Magnetic Detector

Search Result 129, Processing Time 0.026 seconds

Study on Heterogeneous Structures and High-Frequency Magnetic Properties Amorphous CoZrNb Thin Films (비정질 CoZrNb 박막의 불균일 구조와 고주파 자기특성에 관한 연구)

  • 정인섭;허재헌
    • Journal of the Korean Magnetics Society
    • /
    • v.1 no.2
    • /
    • pp.31-36
    • /
    • 1991
  • Structural and compositional heterogeneities of sputter deposited, amorphous $Co_{87}Zr_{4}NB_{9}$ thin films were investigated using TEM and EDS with windowless detector. The films deposited with substrate bias and annealed in rotating magnetc field showed two amorphous phases of Co-rich region and (ZrNb)oxide-rich region, and revealed 'ultra-soft' magnetic properties. Revesible bias-responses and overdamped frequency responses, along with small Hc, Hk and Mr/Ms ratio, give the possibility of ultra-soft magnetic behavior fo CoZrNb thin films. We proposed the vortex type magnetization distribution in remanent state which was correlated with the thin film heterogeneity. Then, the ultra-soft characteristics of the compositionally heterogeneous films were explained by the spin vortices that minimized the total magnetostatic and exchange coupling energies.

  • PDF

Performance Of Iterative Decoding Schemes As Various Channel Bit-Densities On The Perpendicular Magnetic Recording Channel (수직자기기록 채널에서 기록 밀도에 따른 반복복호 기법의 성능)

  • Park, Dong-Hyuk;Lee, Jae-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.7C
    • /
    • pp.611-617
    • /
    • 2010
  • In this paper, we investigate the performances of the serial concatenated convolutional codes (SCCC) and low-density parity-check (LDPC) codes on perpendicular magnetic recording (PMR) channels. We discuss the performance of two systems when user bit-densities are 1.7, 2.0, 2.4 and 2.8, respectively. The SCCC system is less complex than LDPC system. The SCCC system consists of recursive systematic convolutional (RSC) codes encoder/decoder, precoder and random interleaver. The decoding algorithm of the SCCC system is the soft message-passing algorithm and the decoding algorithm of the LDPC system is the log domain sum-product algorithm (SPA). When we apply the iterative decoding between channel detector and the error control codes (ECC) decoder, the SCCC system is compatible with the LDPC system even at the high user bit density.

A study on the measurement of the current & voltage using Photoelastic effect of Optical Fiber (광섬유의 photoelastic효과를 이용한 전류및 전압의 측정에 관한 연구)

  • Choi, Do-In;Kim, Chang-Hyun;Kim, Ho-Seong
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1268-1270
    • /
    • 1995
  • A method using photoelectric effect of a single-mode optical fiber, with a 632.8nm He-Ne laser, has been developed for the simultaneous measurment of current and voltage. The Magnetic stress for the current and the piezoelectric effect for voltage are utilized. It is found that the detector output voltage is proportional to the square of the applied current and the frequency of the output is twice of that of the applied current.

  • PDF

LOW COST DEBRIS ANALYSIS FOR INDUSTRIAL MACHINERY CONDITION EVALUATION

  • Raadnui, S.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.465-466
    • /
    • 2002
  • In any mechanical system consisting of gears, shafts and/or bearings, the majority of metallic particles deposited into and carried by the lubrication system originate from the deterioration of oil-wetted working surfaces, even in proper lubrication system, due to failure mechanism (s) such as wear, fatigue and fretting corrosion. Determination of the point at which transition from normal to abnormal or to actual damage occurs has become a focus of attention in research activities for years, because it has been recognized that reliable, economic operation can be achieved through appropriate preventative measures. Known collectively from 'all size wear debris analysis' as early failure detection, the methods of testing for damage differ considerably, range from a micron or a submicron size debris analysis to Magnetic Chip Detector (MCD) ferrous debris analysis. This paper will be focused on the utilization of the low-cost analysis techniques for evaluation of industrial machinery condition.

  • PDF

The Research & Development of Infra-Red Flame Detector (적외선 불꽃감지기 개발연구)

  • 이복영;권오승;정창기;박상태;조성수
    • Fire Science and Engineering
    • /
    • v.14 no.2
    • /
    • pp.1-6
    • /
    • 2000
  • The radiant energy from a flaming fire of fuels containing carbonaceous material can be applied to fast growing fire. Raiant energy sensinsing technique applied detectors are ultimately effective when early detecting fire alarm system is required or the smoke and heat detectors can not be applied. This study investigated the characteristics of sun light, artificial light and flame radiation light and the foundation technique of flame detecting is established. Pyroelectric element proper for the characteristics of flame radiant energy developed and circuit stabilizing technique, electro-magnetic immunity technique, durable and reliable operating technique to circuits developed.

  • PDF

DC Current sensor using the saturable magnetic cores (자성체포화를 이용한 DC전류센서)

  • Park, Y.T.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.699-702
    • /
    • 2002
  • A DC current sensor is disclosed in which two pairs of saturable cores are provided so as enclose a conductor carrying a direct current to be measured. On each of the saturable cores, a bias winding, a feedback winding and an output winding are wound. Circuit for detection of an asymmetry in the magnetization current, generated by a reference alternating voltage, in a signal-conditioner. The reference alternating voltage is fed to the respective series circuits such that no resultant induction current is induced in the modulating current. The voltages over the resistor form input signals for two peak value detectors, the strength of the output signal of which represents the degree of asymmetry of magnetization current. This paper describes the development a DC current sensor and its signal-conditioner.

  • PDF

Study on Design and Characteristic Analysiy of 6/8 SRM (6/8극 SRM의 설계 및 특성해석에 관한 연구)

  • Sohn Ick-Jin;Oh Seok-Gyu;Hao Chen;Ahn Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.407-410
    • /
    • 2002
  • A three-phase 6/8 structure Switched Reluctance Motor drive, the construction of the stator and the rotor. in the motor, the scheme of the rotor position detector and the main circuit of the power converter are described. The range of the stator pole arc factor and the rotor pole arc factor of the motor are analyzed in the linear region. The optimum range of the stator pole arc factor and the optimum range of the turn-off angle of the main switches in the power converter are given with the 2-D finite element electro-magnetic field calculation of the motor and the nonlinear simulation. Test jesuits of the developed prototype are discussed.

  • PDF

A Development of Computer Controlled 5 Axis Ultrasonic Testing System (컴퓨터제어식 5축 자동초음파탐상장치의 개발)

  • Kim, Y.S.;Kim, J.G.;Park, J.C.;Kim, N.I.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.10 no.2
    • /
    • pp.32-37
    • /
    • 1990
  • A computer controlled 5 axis ultrasonic testing system is developed in order to detect flaws in special parts with complex shape. The various kinds of ultrasonic test can be performed automatically using computer program which was developed by DHI(Daewoo Heavy Industries Ltd.). By use of this computer program, the detector location can be programed and the amplitude signal of echo can be processed digitally. The test results can be plotted graphically on a high resolution display monitor in real time base. The test data can be also saved in magnetic memory devices(HDD or FDD) as well as in the form of hard copy through color printer. The computer software contains c- scan, c+a scan processing programs as well as statistical analysis for test data.

  • PDF

A Clamp Type Sensor for AC/DC Low Current Measurement (클램프 형 직교류 저 전류 측정 센서)

  • 박영태;유광민
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.12
    • /
    • pp.1045-1053
    • /
    • 2002
  • This paper describes characteristics of the developed current sensor by means of two identically wound magnetic cores forming a clamp like for measurement of a low DC, or AC current. This sensor consists of peak value detectors, a sensor of an electrically compensated current transformer type, a reference alternating voltage, Precision measuring circuits to measure the output signals of sensor with harmonics, and can be measured up to 2 A at DC, or AC current. The current sensor shows a measurement accuracy of less than 0.3% in the frequency range 40 Hz - 10 HBz. The resolution and sensitivity of the sensor were evaluated 0.1 mA and 10 mV/mA, respectively.

Spin Transport in a Ferromagnet/Semiconductor/Ferromagnet Structure: a Spin Transistor

  • Lee, W.Y;Bland, J.A.C
    • Journal of Magnetics
    • /
    • v.7 no.1
    • /
    • pp.4-8
    • /
    • 2002
  • The magnetoresistance (MR) and the magnetization reversal of a lateral spin-injection device based on a spin-polarized field effect transistor (spin FET) have been investigated. The device consists of a two-dimensional electron gas (2DEG) system in an InAs single quantum well (SQW) and two ferromagnetic $(Ni_{80}Fe_{20})$ contacts: all injector (source) and a detector (drain). Spin-polarized electrons are injected from the first contact and, after propagating through the InAs SQW are collected by the second contact. By engineering the shape of the permalloy contacts, we were able to observe distinct switching fields $(H_c)$ from the injector and the collector by using scanning Kerr microscopy and MR measurements. Magneto-optic Kerr effect (MOKE) hysteresis loops demonstrate that there is a range of magnetic field (20~60 Oe), at room temperature, over which the magnetization in one contact is aligned antiparallel to that in the other. The MOKE results are consistent with the variation of the magnetoresistance in the spin-injection device.