• 제목/요약/키워드: Magnetic Camera

검색결과 84건 처리시간 0.035초

전자기센서를 이용한 고속철도용 차륜재의 구름접촉피로 손상 모니터링 (Damage Monitoring of Rolling Contact Fatigue in Wheel Specimen for High Speed Train Using Electro-Magnetic Sensor)

  • 권석진;황지성;서정원;이진이
    • 한국정밀공학회지
    • /
    • 제29권6호
    • /
    • pp.600-606
    • /
    • 2012
  • Upon investigation of the damaged wheels for high speed train it was determined that the damage was caused by rolling contact fatigue during operation of train. The major problems that railway vehicle system using wheel-rail has to face during operation of railway vehicle are rolling contact fatigue, cracks in wheels, cracks in rails and wheel-rail profile wear. If these deficiencies are not controlled at early stages the huge economical problems due to unexpected maintenance cost in railway vehicle can be happened. Also, If the accurate knowledge of contact conditions between wheel and rail can be evaluated, the damage of wheel can be prevented and the maintenance operation can save money. This paper presents the applicability of electro-magnetic technique to the detection and sizing of defects in wheel. Under the condition of continuous rolling contact fatigue the damage of wheel has continuously monitored using the applied sensor. It was shown that the usefulness of the applied sensor was verified by twin disc test and the measured damaged sizes showed good agreement with the damaged sizes estimated by electro-magnetic technique.

알루미늄 기판에 코팅된 흑연입자의 배향도 변화와 열방사율 변화의 관계 (Relation between Thermal Emissivities and Alignment Degrees of Graphite Flakes Coated on an Aluminum Substrate)

  • 강동수;이상민;김석환;이상우;노재승
    • 한국재료학회지
    • /
    • 제24권3호
    • /
    • pp.159-165
    • /
    • 2014
  • This study is research on the thermal emissivity depending on the alignment degrees of graphite flakes. Samples were manufactured by a slurry of natural graphite flakes with organic binder and subsequent dip-coating on an aluminum substrate. The alignment degrees were controlled by applying magnetic field strength (0, 1, and 3 kG) to the coated samples. The alignment degree of the sample was measured by XRD. The thermal emissivity was measured by an infrared thermal image camera at $100^{\circ}C$. The alignment degrees were 0.04, 0.11, and 0.17 and the applied magnetic field strengths were 0, 1, and 3 kG, respectively. The thermal emissivities were 0.829, 0.837, and 0.844 and the applying magnetic field strengths were 0, 1, and 3 kG, respectively. In this study the correlation coefficient, $R^2$, between thermal emissivity and alignment degree was 0.997. Therefore, it was concluded that the thermal emissivities are correlated with the alignment degree of the graphite flakes.

Apophis Rendezvous Mission: II. Payloads and Operation Scenario

  • Jeong, Minsup;Choi, Young-Jun;Moon, Hong-Kyu;Kim, Myung-Jin;Choi, Jin;Moon, Bongkon;JeongAhn, Youngmin;Lee, Hee-Jae;Baek, Seul-Min;Yang, Hongu;Ishiguro, Masateru
    • 천문학회보
    • /
    • 제46권1호
    • /
    • pp.44.1-44.1
    • /
    • 2021
  • 한기로 나누어 보면, 흑점의 관측 빈도는 두 기간에서 비슷하지만, 오로라는 냉한기에 집중적으로 관측된다. 특이하게도, 크기가 큰 흑점의 경우는 냉한기보다 온난기에서 관측 빈도가 세 배 이상 높다. 또한, 흑점과 관련된 오로라의 강도를 분석해보면 크기가 큰 흑점은 작은 흑점보다 2~3배 이상 지구영향성이 높다는 것을 알 수 있다.

  • PDF

무전극 형광램프의 주파수 변화에 따른 온도 및 광속 특성 (Properties of Temperature and Brightness Applied on Frequency in Electrodeless Fluorescent Lamp)

  • 이주호;최기승;김남군;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.607-608
    • /
    • 2006
  • In recent, it became necessary to develop the technology about electrodeless fluorescent lamp according to demand of the electrodeless fluorescent lamp system that used higher efficiency and advantage of long lifetime. Inductively coupled plasma is commonly used for electrodeless lamp due to its ease of plasma generation. An electric power efficiency of electrodeless fluorescent lamp has big relative property of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. We have examined temperature and flux characteristic by frequency. Considering using frequency 2.65[MHz], Frequency was changed from 2.05(MHz) to 3.05[MHz] to recognize flux and temperature change of lamp. I used LMS(Lighting Measurement System) to measure flux and IR Camera to measure temperature of lamp.

  • PDF

무전극 형광램프의 주파수 변화에 따른 온도 및 광속 특성 (Properties of Temperature and Brightness Applied on Frequency in Electrodeless Fluorescent Lamp)

  • 이주호;최기승;김남군;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2239-2240
    • /
    • 2006
  • In recent, it became necessary to develop the technology about electrodeless fluorescent lamp according to demand of the electrodeless fluorescent lamp system that used higher efficiency and advantage of long lifetime. Inductively coupled plasma is commonly used for electrodeless lamp due to its ease of plasma generation. An electric power efficiency of electrodeless fluorescent lamp has big relative property of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. We have examined temperature and flux characteristic by frequency. Considering using frequency 2.65[MHz], Frequency was changed from 2.05[MHz] to 3.05[MHz] to recognize flux and temperature change of lamp. I used LMS(Lighting Measurement System) to measure flux and IR Camera to measure temperature of lamp.

  • PDF

무전극 형광램프의 주파수 변화에 따른 온도 및 광속 특성 (Properties of Temperature and Brightness Applied on Frequency in Electrodeless Fluorescent Lamp)

  • 이주호;최기승;김남군;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1273-1274
    • /
    • 2006
  • In recent, it became necessary to develop the technology about electrodeless fluorescent lamp according to demand of the electrodeless fluorescent lamp system that used higher efficiency and advantage of long lifetime. Inductively coupled plasma is commonly used for electrodeless lamp due to its ease of plasma generation. An electric power efficiency of electrodeless fluorescent lamp has big relative property of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. We have examined temperature and flux characteristic by frequency. Considering using frequency 2.65[MHz], Frequency was changed from 2.05[MHz] to 3.05[MHz] to recognize flux and temperature change of lamp. I used LMS(Lighting Measurement System) to measure flux and IR Camera to measure temperature of lamp.

  • PDF

캠코더용 Iris Assembly의 국산화 및 생산 기술 개발 (A Study of Development and Production Technology for Camcoder Iris Assembly)

  • 고종선
    • 전력전자학회논문지
    • /
    • 제3권1호
    • /
    • pp.53-60
    • /
    • 1998
  • 본 논문은 비디오 카메라 및 프로젝션 TV 등 영상 기기의 요소 부품인 캠코더용 Iris Assembly에 있어서 동작원리, 구성부품의 특성, 동작특성 해석과 각 요소부품의 개발시 중요 Know-how 등을 언급한다. 저전력용으로 소형이지만 간단한 구조로 만들기 위한 자계회로를 실현하였다. 특히 잔류 자계의 영향과 동작 시간의 관계를 실험적으로 규명한다. 소형 정밀부품의 국산화 개발에 있어서 필요한, 간편한 구동 시스템 원리와 그로 인해 발생하는 비선형성 토오크의 문제점 및 개발 공정 등을 설명하고, 각 부품의 Burr 최소화를 위한 점검 요소, 소형 요소 부품의 공정 등을 다룬다.

무전극 형광램프의 주파수 변화에 따른 온도 및 광속 특성 (Properties of Temperature and Brightness Applied on Frequency in Electrodeless Fluorescent Lamp)

  • 이주호;최기승;김남군;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1733-1734
    • /
    • 2006
  • In recent, it became necessary to develop the technology about electrodeless fluorescent lamp according to demand of the electrodeless fluorescent lamp system that used higher efficiency and advantage of long lifetime. Inductively coupled plasma is commonly used for electrodeless lamp due to its ease of plasma generation. An electric power efficiency of electrodeless fluorescent lamp has big relative property of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. We have examined temperature and flux characteristic by frequency. Considering using frequency 2.65[MHz], Frequency was changed from 2.05[MHz] to 3.05[MHz] to recognize flux and temperature change of lamp. I used LMS(Lighting Measurement System) to measure flux and IR Camera to measure temperature of lamp.

  • PDF

카메라 기반의 원격 모니터링 시스템을 위한 안드로이드 스마트폰 앱 개발 (Development of Android Smartphone App for Camera-based Remote Monitoring System)

  • 이성규;김진수;김영섭;최철웅
    • Spatial Information Research
    • /
    • 제19권5호
    • /
    • pp.87-96
    • /
    • 2011
  • 최근 모바일 사용자들은 언제 어디서나 스마트폰을 이용한 인터넷 접속이 가능하고, 이를 통한 정보 검색 및 공유가 가능하다. 또한, MEMS(micro-electro mechanical systems) 기술의 발달과 함께 첨단 기능을 가진 센서들이 초소형화, 저가격화 되면서 스마트폰의 활용도가 점점 증가하고 있다. 스마트폰은 고해상도 카메라, GPS, 자이로스코프, 자기 센서 등과 같은 다양한 센서를 탑재하고 있어 카메라를 이용한 원격 모니터링 연구에 적합한 시스템 구성을 지닌다. 원격 모니터링 시스템은 영상 촬영을 위한 카메라와 영상 전송을 위한 인터넷 망이 필요하고, 이로 인해 모니터링 장소에 많은 영향을 받는 단점이 있다. 본 연구는 스마트폰 기술을 이용하여 원격 모니터링이 가능한 모니터링 앱을 설계하고 개발하는데 그 목적을 둔다. 이를 위해 안드로이드 SDK 2.3을 기반으로 자바와 C를 이용하여 모니터링 앱을 개발하였다. 개발된 모니터링 앱은 정해진 시간에 ROI(region of interest)를 촬영하고 촬영된 영상은 자동으로 서버로 전송되도록 구현되었다. 개발된 앱은 SMS(short message service)를 이용한 원격제어도 가능하다. 본 연구에서 제안한 모니터링은 스마트폰에 내장된 CMOS 카메라를 이용하여 고해상도 영상 촬영이 가능하며, 3G와 Wi-Fi를 이용하여 언제 어디서나 촬영된 영상과 정보를 서버에 자동으로 전송 가능하다.

Single-Port Thoracic Surgery: A New Direction

  • Ng, Calvin S.H.
    • Journal of Chest Surgery
    • /
    • 제47권4호
    • /
    • pp.327-332
    • /
    • 2014
  • Single-port video-assisted thoracic surgery (VATS) has slowly established itself as an alternate surgical approach for the treatment of an increasingly wide range of thoracic conditions. The potential benefits of fewer surgical incisions, better cosmesis, and less postoperative pain and paraesthesia have led to the technique's popularity worldwide. The limited single small incision through which the surgeon has to operate poses challenges that are slowly being addressed by improvements in instrument design. Of note, instruments and video-camera systems that are narrower and angulated have made single-port VATS major lung resection easier to perform and learn. In the future, we may see the development of subcostal or embryonic natural orifice translumenal endoscopic surgery access, evolution in anaesthesia strategies, and cross-discipline imaging-assisted lesion localization for single-port VATS procedures.