• Title/Summary/Keyword: MafK

Search Result 137, Processing Time 0.031 seconds

Validity and Reliability of Translated Multidimensional Assessment of Fatigue Scale for the Patients with Rheumatoid Arthritis (류마티스 관절염환자용 다차원적 피로척도의 타당도 및 신뢰도)

  • Lee, Kyung-Sook;Lee, Eun-Ok
    • Journal of muscle and joint health
    • /
    • v.5 no.2
    • /
    • pp.206-221
    • /
    • 1998
  • The purpose of this study was to validate translated Multidimensional Assessment of Fatigue(MAF) scale. The scale is a 16-item scale that measures four dimensions of fatigue : severity, distress, impact, timing. Fourteen items are numerical rating scales and 2 items have multiple choice responses. Data were collected from the 137 patients with rheumatoid arthritis after content validation. Criterion validity was tested by correlation coefficient with Piper Fatigue Scale, which resulted in 0.7573(p<.0000). Construct validity was tested by item analysis and factor analysis. Corrected item-total correlation coefficients were 0.63-0.88. And factor analysis showed 2 factors : fatigue degree factor and fatigue impact factor. These two factors explained 73.5% of total variance. Reliability of internal consistency was 0.96 in Cronbach's alpha. Further validation study is necessary in each factor in other settings with other subjects.

  • PDF

Heart Rate Estimation Based on PPG signal and Histogram Filter for Mobile Healthcare

  • Lee, Ju-Won;Lee, Byeong-Ro
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.1
    • /
    • pp.112-115
    • /
    • 2010
  • The heart rate is the most important vital sign in diagnosing heart status. The simple method to measure the heart rate in the mobile healthcare device is using the PPG signal. In developing the mobile healthcare device using the PPG signal, the most important issue is the inaccuracy of the measured heart rate because the PPG signal is distorted from the user's motions. To improve the problem, this study proposed the new method that is to estimate the heart rate without an additional sensor in real life. The proposed method in this study is using the histogram filter. In order to evaluate the performance of the proposed method, the study compares its results with the moving average method in motion environment. According to the experimental results, the performance of the proposed method was more than 40% better than the performances of the MAF.

Design and Implementation of a Robust Predictive Control Scheme for Active Power Filters

  • Han, Yang;Xu, Lin
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.751-758
    • /
    • 2011
  • This paper presents an effective robust predictive control scheme for the active power filter (APF) using a smith-predictor based current regulator, which show superior features when compared to proportional-integral (PI) controllers in terms of an enhanced closed-loop bandwidth and an improved current tracking accuracy. A moving average filter (MAF) is implemented using a field programmable gate array (FPGA) for signal pre-processing to eliminate the switching ripple contamination. An adaptive linear neural network (ADALINE) is used for individual harmonic estimation to achieve selective compensation purpose. The effectiveness and validity of the devised control algorithm are confirmed by extensive simulation and experimental results.

Modulated Finite Control Set - Model Predictive Control for Harmonic Reduction in a Grid-connected Inverter

  • Nguyen, Tien Hai;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.268-269
    • /
    • 2017
  • This paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. Distorted grid condition is undesirable due to negative effects such as power losses and heating problem in electrical equipments. To enhance the power quality of distributed generation systems under such a condition, a modulated finite control set - model predictive control (MFCS-MPC) scheme will be proposed, in which the optimal switching signals of inverter are chosen by online basis using the principle of current error minimization. In addition, the moving average filter (MAF) is used to improve the phase-lock loop in order to obtain the harmonic-free reference currents on the stationary frame. The usefulness of the proposed MFCS-MPC method is proved by the comparative simulation results under different operating conditions.

  • PDF

Effect of Soyangin-Hyeongbangpaedok-san on Anti-CD3 Stimulated Mouse T Cells In Vivo and In Vitro (소양인 형방패독산(荊防敗毒散)의 마우스 T 세포 활성에 대한 실험적 연구)

  • Kim, Joong-Bae;Kang, Hee;Ahn, Kwang-Seok;Shim, Bum-Sang;Kim, Sung-Hoon;Choi, Seung-Hoon;Ahn, Kyoo-Seok
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.3
    • /
    • pp.554-561
    • /
    • 2009
  • Soyangin-Hyeongbangpaedok-san(SHBPDS) is a herbal formula used for the common cold or upper respiratory illness. In order to investigate the effect of SHBPDS, mice were orally administered with SHBPDS alcohol extract for 7 days followed by intravenous anti-CD3 injection. In addition, splenocytes and CD4 T cells were cultured with SHBPDS in response to anti-CD3 in vitro and cytokines and transcription factors were evaluated. In vivo treatment with SHBPDS significantly augmented the expressions of the percentage of CD4 T cells and CD 69, an indicator of early T cell activation. Serum levels of IL-4 were significantly increased but those of IFN-${\gamma}$ and IL-2 did not reach statistical significance. The expressions of IFN-${\gamma}$ and T-bet mRNA were significantly downregulated in SHBPDS treated mice while those of IL-4 and C-Maf were significantly upregulated. In vitro stimulation of splenocytes and CD4 T cells by SHBPDS resulted in a reduction in IFN-${\gamma}$ secretion and STAT4 activity. The IL-4 releases from both cells were slightly reduced, but STAT6 activity was rather increased. In conclusion, SHBPDS exerted an inhibition in the expression of IFN-${\gamma}$, T-bet and STAT4 while IL-4, C-Maf and STAT6 were increased. Further studies are required to examine its pharmacological effects using more appropriate animal experiments.

APICAL PREPRATION SIZE IN INFECTED ROOT CANALS (감염근관에서의 apical preparation size)

  • Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.1
    • /
    • pp.1-4
    • /
    • 2010
  • The final preparation (MAF) size in infected root canals is still controversial. Nonetheless, recent studies demonstrated that larger apical preparation sizes produces a greater reduction in remaining bacteria and dentinal debris as compared to smaller apical preparation sizes. Therefore, clinicians should be practiced with treatment strategies guided by evidence-based information, especially in infected/failed root canals.

A Study on the Urea-SCR System for NOx Reduction of a light-Duty Diesel Engine (소형 디젤엔진의 NOx 저감을 위한 Urea-SCR 시스템에 관한 연구)

  • Nam Jeong-Gil
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.5
    • /
    • pp.57-63
    • /
    • 2005
  • The effects of an urea injection at the exhaust pipe for a 4-cylinder DI(Direct Injection) diesel engine were investigated with the parameters such as urea-SCR(Selective Catalytic Reduction) and EGR system. The urea quantity was controlled by NOx quantity and MAF(Manifold Air Flow). The urea injection quantity can be controlled with the urea syringe pump, precisely. The effects of NOx reduction for the urea-SCR system were investigated with and without ECR engine, respectively. It was concluded that the SUF(Stoichiometric Urea Flow) is calculated and the NOx results are visualized with engine speed and load. Furthermore, the NOx map is made from this experimental results. It was suggested, therefore, that NOx reduction effects of the urea-SCR system without the EGR engine were better than that with the EGR engine except of low load and low speed.

Experimental induction of the two-host life cycle of Sarcocystis cruzi between dogs and Korean native calves

  • Wee, Sung-Hwan;Shin, Sung-Shik
    • Parasites, Hosts and Diseases
    • /
    • v.39 no.3
    • /
    • pp.227-232
    • /
    • 2001
  • Eight dogs were experimentally infected with Sarcocystis by oral inoculation of cardiac muscle from naturally infected cattle. The infected dogs commenced discharging of sporocysts in the feces after 10 to 12 days of inoculation, and continued until 20 and 35 days after inoculation. Three dogs were reinfected with cardiac muscle from the naturally infected cattle. Sporocysts reappeared in the feces on 12 to 13 days after reinfection. Sarcosystis sporocysts collected from the experimentally infected dogs were fed to each of the two 30-day-old Korean native calves. The infected calves remained clinically normal, except for the high fever (${\geq}{\;} 40^{\circ}C$) and decreased hematocrit values on day 30 to 40 post inoculation. Muscular cysts of Sarcocystis were found from infected calves on day 40 post inoculation. Proliferative forms of Sarcocystis were also observed in the muscle of infected calves. These results suggest that the Sarcocystis cruzi found in Korean native cattle has a 2-host life cycle with dogs as the definitive host and Korean native calves as the intermediate host.

  • PDF

Floating Point Unit Design for the IEEE754-2008 (IEEE754-2008을 위한 고속 부동소수점 연산기 설계)

  • Hwang, Jin-Ha;Kim, Hyun-Pil;Park, Sang-Su;Lee, Yong-Surk
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.10
    • /
    • pp.82-90
    • /
    • 2011
  • Because of the development of Smart phone devices, the demands of high performance FPU(Floating-point Unit) becomes increasing. Therefore, we propose the high-speed single-/double-precision FPU design that includes an elementary add/sub unit and improved multiplier and compare and convert units. The most commonly used add/sub unit is optimized by the parallel rounding unit. The matrix operation is used in complex calculation something like a graphic calculation. We designed the Multiply-Add Fused(MAF) instead of multiplier to calculate the matrix more quickly. The branch instruction that is decided by the compare operation is very frequently used in various programs. We bypassed the result of the compare operation before all the pipeline processes ended to decrease the total execution time. And we included additional convert operations that are added in IEEE754-2008 standard. To verify our RTL designs, we chose four hundred thousand test vectors by weighted random method and simulated each unit. The FPU that was synthesized by Samsung's 45-nm low-power process satisfied the 600-MHz operation frequency. And we confirm a reduction in area by comparing the improved FPU with the existing FPU.

EVALUATION OF THE INFLUENCE OF APICAL SIZES ON THE APICAL SEALING ABILITY OF THE MODIFIED CONTINUOUS WAVE TECHNIQUE (Modified Continuous Wave Technique을 이용한 근관충전시 형성된 치근단 크기가 치근단 폐쇄에 미치는 영향)

  • Ryu, Mu-Hyun;Jung, Il-Young;Lee, Seung-Jong;Shin, Su-Jung;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.66-75
    • /
    • 2008
  • This study examined the influence of the apical sizes on the sealing ability of a root canal filling. Thirty-six single rooted teeth with a single canal were divided into 3 groups (n = 12) and instrumented with either the $Profile^{(R)}$ or $LightSpeed^{(R)}$ system to achieve three different apical sizes (master apical file [MAF] of #25, #40, or #60). The teeth were filled with gutta perch a using a modified continuous wave technique. The level of microleakage was determined by immersing ten teeth from each group into India ink for 1 week followed by clearing with nitric acid, ethyl-alcohol, and methylsalicylate. The microleakage was measured using vernier calipers. The data was analyzed statistically using Kruskal-Wallis one-way ANOVA and a Student-Newman-Keuls Method. Two teeth from each group were sectioned horizontally at 1, 2, 3 and 4 mm from the apex in order to observe a cross section. The apical size was significantly (p < .05) influenced the level of microleakage. In the Student-Newman-Deuls Method, MAF sizes of #25 and #40; and MAF sizes of #25 and #60, respectively showed a statistically significant difference. There was no significant difference between #40 and #60. In most cross sections, oval-shaped canals were observed, and the irregularity of the internal surface increased with decreasing apical size. There was also an increase in the area of recess, which is the area where the canal space is not filled with either gutta-percha or sealer. When the root canals are filled using a modified continuous wave technique, canal filling with more consistent and predictable outcome may be expected as the apical preparation size is increased.