• 제목/요약/키워드: Machine speed

검색결과 2,750건 처리시간 0.039초

퍼팅 스트로크에서 퍼터의 선 운동량 크기에 따른 볼의 이동 속도 변화에 관한 연구 (Ball Velocity Changes Depending on the Different Linear Momentum of Putter Head during the Putting Strokes)

  • 박진
    • 한국운동역학회지
    • /
    • 제17권4호
    • /
    • pp.83-88
    • /
    • 2007
  • The purpose of this study was to investigate the ball velocity changes depending on the different linear momentum of putter head. For this study, two different moving conditions(25cm free fall and 35cm free fall) of putter head were set. And two different types of ground conditions were used which are artificial grass green($180cm{\times}600cm{\times}1cm$) and glass green($40cm{\times}130cm{\times}1cm$). Movements of putter head and ball were recorded with 2 HD video cameras(60 Hz, 1/500s shutter speed). Small size control object($18.5cm{\times}18.5cm{\times}78.5cm$) was used in this study. Ball and putter head velocities were calculated by the First Central Difference Method(Hamill & Knutzen, 1995). Linear momentum of ball and putter head were calculated with mass and its velocities. Before impact, the velocity of the putter head of 35cm free fall was about 30% greater than that of the putter head of 25cm free fall. Linear momentum of putter head of 35cm free fall was about 0.355-0.364kg m/s and 25cm free fall was 0.251 kg m/s. After impact, putter head lost its linear momentum about 14-19% and adjusting time of putter head after impact would be 0.1 second. After 0.1 second, putter moved the route same as before impact. Maximum ball velocities were appeared 0.08s-0.10s after impact no matter what the ground conditions are. Ball velocities struck by 35cm free fall were 30 % faster than 25cm free fall. Linear momentum of ball struck by putter head was greater than that of expected amount because the moving ball has translational energy and rotational energy. Future study must treat three things. One is ball must struck by the different putters with different materials. Another is two-piece ball and three-piece ball should be used for the same condition studies. The other is height of center of rotation of club should be changed. In this study, the height of center of rotation of club head is 71cm from the ground. But recently many golfers used the long putter. Therefore next study should apply the different height of center of rotation of club head.

영역카메라를 이용한 이송중인 제재목의 화상처리시스템 개발 (The Development of Image Processing System Using Area Camera for Feeding Lumber)

  • 김병남;이형우;김광모
    • Journal of the Korean Wood Science and Technology
    • /
    • 제37권1호
    • /
    • pp.37-47
    • /
    • 2009
  • 최근 목재산업계에서는 사람의 시각을 대체하는 기계시각을 이용한 화상처리시스템을 도입하여 제재목 등급 판정의 자동화, 제품의 품질향상 및 재단 최적화 등에 활용하고 있다. 본 연구에서는 국내산 소나무 제재목을 대상으로 표면결함검출을 위한 화상처리시스템을 개발하고자 하였으며, 주로 이용되고 있는 라인스캔카메라를 대신하여 비교적 저가의 영역카메라를 이용하였을 때 발생되는 문제점을 해결하고자 하였다. 벨트컨베이어의 불균일한 이송속도에 따른 문제점을 해결하기 위해 화상의 특징점을 이용한 결과 효과적인 화상병합을 할 수 있었다. 일반적인 영역카메라는 송재속도 15.7 m/min 이상에서는 모션블러에 의한 화상의 품질저하로 인하여 화상처리가 어려웠고 화상처리에 적합한 송재속도는 13.8 m/min였으며 추후 송재속도를 향상시키기 위해서는 전자셔터 속도가 빠른 카메라의 사용이 요구되었다. 녹색 컨베이어벨트상의 제재목 화상의 배경과의 분리를 위해서는 RGB필터의 red 채널을 이용하면 효과적이었다. 옹이검출을 위한 문턱값 판정법은 화상분석형인 문턱값 감소법이 우수하였으며 히스토그램분석형 중에서는 엔트로피법이 적합하였다.

병렬 연산을 이용한 방출 단층 영상의 재구성 속도향상 기초연구 (Preliminary Study on the Enhancement of Reconstruction Speed for Emission Computed Tomography Using Parallel Processing)

  • 박민재;이재성;김수미;강지연;이동수;박광석
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권5호
    • /
    • pp.443-450
    • /
    • 2009
  • 목적: 기존의 영상 재구성은 간소화된 투사 물리 모델을 사용하고 있다. 하지만 3D 재구성과 같은 실제적인 물리 모델은 시간이 많이 걸려서 임상에서 모든 데이터에 적용하기 힘들고, 복잡한 물리모델을 설명하기 위해 큰 메모리를 사용하면 한대의 일반적인 재구성 머신으로는 불가능하다. 개인 컴퓨터들에서도 큰 규모의 기술을 가능하게 하기위해, 병렬 연산을 이용한 빠른 재구성의 현실적인 분산메모리 모델을 제시한다. 대상 및 방법: 실제로 구현하는 가능성을 보기 위해 가상 컴퓨터들을 이용하여 선행 연구를 진행하였고, 다양한 가능성을 테스트하기 위해 상용서비스를 하고 있는 슈퍼컴퓨터(Tachyon)에서 성능 테스트를 하였다. 가장 많이 사용되는 2D 투사 영상과 실제적인 물리 모델인 3D 응답라인을 이용한 기댓값 최대화 알고리즘을 테스트하였다. 스터디 중 특정 반복횟수 이후에 속도가 최대 6배까지 느려지는 현상이 발견되어 컴파일러 최적화를 통해 병렬 효율의 극대화를 꾀하였다. 결과: Linux에서 MPICH와 NFS를 이용하여, 여러 컴퓨터에서 하나의 프로그램으로 분산 연산이 가능하였다. 병렬 연산을 했을 때 동일한 반복 연산에서 재구성된 영상간의 차이가 실수의 유효숫자(6bit) 정도임을 확인하였다. 2배의 연상장치를 사용했을 때 1.96배의 좋은 병렬화 효율을 보여주었다. 반복 연산 횟수가 증가함에 따라 느려지는 현상은 SSE를 이용한 Vectorization 방법을 사용했을 때 해결할 수 있었다. 결론: 이번 연구를 통해 일반 컴퓨터들을 이용한 현실적인 병렬 컴퓨터 시스템을 구성하여, 작은 메모리의 단일 일반 컴퓨터로는 불가능한 간단화 할 수 없는 복잡한 물리 과정도 영상 재구성 방법에 사용 가능하게 되었다.

치과용 아말감의 미세경도에 관한 실험적연구 (AN EXPERIMENTAL STUDY ON THE MICROHARDNESS OF DENTAL AMALGAMS)

  • 신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제8권1호
    • /
    • pp.89-96
    • /
    • 1982
  • The purpose of this study is to identify the phases of four different types, low-copper lathe cut (Type II, class 1) and spherical (Type II, class 2) amalgam alloys which are made by Caulk company and high copper Dispersalloy (Type II, class 3) made by Johnson & Johnson and Tytin (Type I, class 2) made by S.S. White and to determine the Vickers hardness number on the individual phase and four different types of dental amalgam. After each amalgam alloy and Hg measured exactly by the balance was triturated by the mechanical amalgamator (De Trey), the triturated mass was inserted into the cylindrical metal mold which was 4 mm in diameter and 12mm in height and was pressed by the Instron Universal Testing machine (Model 1125) at the speed of 1mm/minute with 143$kg/cm^2$ according to the A.D.A. Specification No. 1. The Specimen removed from the mold, mounted and stored in the room temperature for 7 days. The speciman was polished with the emery paper from #220 to #1200 and finally on the polishing cloth with 0.3 and 0.05 um $Al_2O_3$ powder suspended in water. And then each specimen was etched by Allan's method and washed with Sodium Bisulfinite for 30 seconds. Finally differentiation and metallography on each phase were obtained by using metallographical microscope (Versamet, Union) and microhardness was obtained by using microhardness tester (MVH-2, Torsee). The results were as follows: 1. In the low-copper amalgam, the ${\gamma}$, ${\gamma}_1$ and ${\gamma}_2$ phase were observed and in the high-copper amalgam, the ${\gamma}$, ${\gamma}_1$. ${\epsilon}$ and ${\eta}$ phases were observed but ${\gamma}_2$ phase was not observed. 2. Among the microhardness of each amalgam phase measured under pressing a vickers diamond indenter with 2.0gm load for 30 seconds, e phase has the highest V.H.N (314 ${\pm}$ 20), and in low-copper amalgam 12 phase has the lowest V.H.N. (29${\pm}$1) and ${\eta}$ phase which was observed in high-copper amalgam has 230${\pm}$13 V.H.N and this phase is considerd to contribute to strengthen the handness in amalgam. 3. The V.H.N. measured under pressing a Vickers diamond indenter with 300.0gm load for 30 seconds in low-copper amalgam was lower than that of high-copper amalgam.

  • PDF

법랑질에 의한 수종의 간접복합레진의 마모에 관한 연구 (AN IN-VITRO WEAR STUDY OF INDIRECT COMPOSITE RESINS AGAINST HUMAN ENAMEL)

  • 이현정;전영찬;정창모;정희찬
    • 대한치과보철학회지
    • /
    • 제45권5호
    • /
    • pp.611-620
    • /
    • 2007
  • Statement of problem: Second-generation indirect composite resins have been improved flexural strength, compressive strength, hydrolytic degradation resistance, wear resistance compared to first-generation indirect composite resins, but there are still some problems as hydrolysis and low wear resistance. Some manufacturers claim that wear resistance of their materials has been improved, but little independent study has been published on wear properties of these materials and the properties specified in the advertising materials are largely derived from in-house or contracted testing. Purpose: This study was to evaluate the wear of indirect composite resins (SR Adore, Sinfony, Tescera ATL) and gold alloy against the human enamel. Material and method: Extracted human incisors and premolars were sectioned to $2{\times}2{\times}2mm$ cube and embedded in the clear resin and formed conical shaped antagonist to fit the jig of pin-on-disk tribometer. Total 20 antagonists were stored in distilled water. Five disk samples, 24mm in diameter and 1.5mm thick, were made for each of three groups of indirect composite resins and gold alloy group, and polished to #2,000 SiC paper on auto-polishing machine. Disk specimens were tested for wear against enamel antagonists. Wear test were conducted in distilled water using a pin-on-disk tribometer under condition (sliding speed 200rpm contact load 24N, sliding distance 160m). The wear of the enamel was determined by weighing the enamel antagonist before and after test, and the weight was converted to volumes by average density. The wear tracks were analyzed by scanning electron microscopy and surface profilometer to elucidate the wear mechanisms. Statistical analysis of the enamel wear volume, wear track depth and wear tract width of disk specimens were accomplished with one-way ANOVA and the means were compared for significant differences with Scheffe's test. Results: 1. The enamel wear was most in gold alloy, but there were no statistically significant differences among all the groups (P>.05). 2. In indirect composite resin groups, the group to make the most shallow depth of wear tract was Sinfony, followed by Tescera ATL, SR Adoro (P<.05). Gold alloy was shallower than Sinfony, but there was no statistically significant difference between Sinfony and gold alloy (P>.05). 3. The width of wear tract of SR Adore was larger than the other groups (P<.05), and there were no statistically significant differences among the other groups (P>.05). 4. SEM analysis revealed that Sinfony and gold alloy showed less wear scars after test, Tescera ATL showed more wear scars and SR Adore showed the most. Conclusion: Within the limits of this study, Sinfony and gold alloy showed the least wear rates and showed similar wear patterns.

이원중합형 코어 축조용 복합레진의 결합강도에 대한 NaOCI의 영향에 대한 연구 (Influence of Sodium Hypochlorite on Bond Strength of Dual-cured Core Build-up Resin Composite)

  • 이준봉;박종덕;권수미;유미경;이광원
    • 구강회복응용과학지
    • /
    • 제23권4호
    • /
    • pp.283-292
    • /
    • 2007
  • Two-step or one-step bonding systems generally inhibit curing process of dual-cured core build-up resin composite for their adhesive acidity. In addition this dual-cured core build-up resin composite can be applied to dentin of pulp chamber and root at the time that complete the endodontic treatment. The purpose of this investigation was to determine the influence of sodium hypochlorite on rnicrotensile bond strength of dual-cured core build-up resin composite. Extracted human molars were horizontally sectioned with 1mm thickness using low speed diamond saw. After the sectioned specimens were divided into 8 groups, adhesive systems (Clearfil SE-Bond, Prime&Bond NT[2-step, 1-step], Adper Prompt L-Pop) were then applied with or without sodium hypochlorite pretreatment. The treated specimen was filled with dual-cured core build-up resin composite (Luxacore, DMG corp., German). Then light cured for 40 seconds and soaked in $37^{\circ}C$ water bath for 24 hours. After the treated specimen was grinded with 1mm width and measured rnicrotensile bond strength by testing machine. Additionally 8 teeth were prepared for SEM evaluation. The results were as follows. : NaOCl treated groups generally had lower rnicrotensile bond strength but did not show any difference statistically except Adper Prompt L-Pop. When the teeth were treated by NaOCl, though the difference of applied adhesive system, it had no statistically significant difference within the NaOCl treated groups except the relation of between ClearFil SE-Bond adhesive system and Adper Prompt L-Pop adhesive system. In the SEM evaluation, NaOCl treated groups presented relatively long resin tags and incomplete hybrid layer formation generally.

Lithium Disilicate (IPS e.max CAD) 코어와 전장 도재 사이의 전단결합강도에 관한 연구 (A Study on the Shear Bond Strength of Veneering Ceramics to the Lithium Disilicate (IPS e.max CAD) Core)

  • 김기백;김재홍
    • 치위생과학회지
    • /
    • 제13권3호
    • /
    • pp.290-295
    • /
    • 2013
  • 본 연구는 심미 치과보철물에 사용되는 지르코니아, lithium disilicate 코어와 전장도재 사이의 전단결합강도를 측정하고, 금속도재관을 대조군으로 설정하여 비교하였다. 직사각기둥 모양의 시편을 각각 10개씩 제작하여 코어와 전장도재 사이의 전단결합강도를 측정한 후 파절면의 양상을 실체현미경을 통해 관찰하였다. 제한된 조건하에 시행된 실험을 통하여 심미보철 분야에 널리 적용되고 있는 치과용세라믹 코어의 전단결합강도를 확인하였으며, 측정 후 비교분석된 결과는 다음과 같다. 2종의 치과용 세라믹 코어와 전장도재 간에 전단결합강도는 금속도재관의 전단결합강도와 유의한 차이가 있었다 (p<0.05). 본 실험 결과를 토대로 ZB군은 임상적으로 받아들여지는 전단결합강도 범위 내 분포를 보이지만, LB군은 임상허용 범위에 못 미치는 결과값을 보였다. 금속도재관과 달리 지르코니아, lithium disilicate 전부도재관은 모두 혼합형 파절양상을 보였다. 결론적으로 전단결합강도 실험에 사용된 시편이 임상적인 치과보철물의 형태와는 달리 실험을 위한 시편의 형태로 제작되어 임상적 결과를 반영하지 못했으며 구강 내의 상황과도 다르다는 한계점을 가지고 있다. 추후에는 이를 보완하여 치과보철물과 유사한 형태의 시편을 이용한 전단결합 강도의 측정과 구강 내 조건을 고려한 추가 실험이 필요하다고 생각된다.

상아질 표면상태에 따른 광중합형 글래스아이오노머 시멘트의 전단결합강도에 관한 연구 (A STUDY ON THE SHEAR BOND STRENGTH OF LIGHT CURED GLASS IONOMER CEMENTS TO CONTAMINATED DENTIN)

  • 김경화;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.609-621
    • /
    • 1997
  • The purpose of this study was to evaluate the shear bond strength of three light-cured glass ionomer cements to blood contaminated bovine dentin. The materials used in this study were Fuji II LC, Dyract and Variglass VLC. The dentin conditioners were 10% polyacrylic acid, 10% maleic acid and 10% phosphoric acid. 180 lower anterior bovine teeth were selected in this study. The teeth were embedded in acrylic resin and were grounded with 320 to 600 grit silicon carbide paper to create a flat dentin surface. The teeth were divided into SIX groups. The experimental procedures in six groups were as follows; Group l(GF) : Samples bonded to dentin surface with Fuji II LC after 10% polyacrylic acid treatment. Group 2(BGF) : Samples bonded to dentin surface with Fuji II LC after 10% polyacrylic acid treatment and blood contamination. Group 3(MD) : Samples bonded to dentin surface with Dyract after 10% maleic acid treatment. Group 4(BMD) : Samples bonded to dentin surface with Dyract after 10% maleic acid treatment and blood contamination. Group 5(PV) : Samples bonded to dentin surface with Variglass VLC after 10% phosphoric acid treatment. Group 6(BPV) : Samples bonded-to dentin surface with Variglass VLC after 10% phosphoric acid treatment and blood contamination. Group 1,3 and 5 were classified into the control groups, while group 2,4 and 6 were classified into the experimental groups. Each group contained 30 samples. After 24 hours water storage at $37^{\circ}C$, all smples were subjected to a shear load to fracture at a cross head speed of 1.0 mm/min with Instron universal testing machine(No. 4467). Debonded surfaces were observed under Scanning Electron Microscope(Hitachi S-2300) at 20kvp. The data were evaluated statistically at the 95% confidence level with Student's t-test. The following results obtained; 1. Shear bond strengths were higher in the control groups(1,3,5 group) than in the experimental groups(2,4,6 group). 2. The shear bond strength of group 5(PV) was the highest in the control groups, and the group 5 was significantly higher than the group l(GF) on the shear bond strength. 3. The group 4(BMD) was the highest on the shear bond strength, and the group 2(BGF) was the lowest in the experimental groups. The group 4(BMD) and 6(BPV) showed a significant difference with the group 2 on the shear bond strength. 4. All the groups showed an adhesive-cohesive failure. except the group 2(BGF) showing adhesive failure.

  • PDF

바이오매스 및 생분해 촉매제를 이용한 산화생분해 투명 바이오 필름 개발 (Development of Oxo-biodegradable Transparent Bio Films Using Biomass and Biodegradable Catalyst)

  • 유영선;김영태;박대성;최성욱
    • 청정기술
    • /
    • 제23권2호
    • /
    • pp.133-139
    • /
    • 2017
  • 식물로부터 유래하는 바이오매스를 25% 이상 함유하는 바이오 베이스 플라스틱은 탄소배출을 억제하는 효과가 있고, 한정된 자원인 석유의 소비량을 줄일 수 있으며, 산화생분해 첨가제를 추가 적용하면 폐기 후에는 미생물에 의해 생분해되기 때문에 친환경적인 소재로 최근 연구가 활발하다. 본 연구에서는 염화비닐수지에 식물체 유래 가소제, 생분해 촉매제를 첨가하여 생분해성 및 물성변화등을 관찰하였다. 또한 초기 신장율과 인장강도 등의 물성이 우수한 자연에서 분해되는 산화 생분해 투명 바이오 필름을 제조하여 식품포장재로서의 제품 안전성을 시험하였다. 염화비닐 수지와 1차 가소제, 2차 가소제, 방담제, 안정제를 비율에 맞게 투입한 다음, 고속혼합기에서 혼합한 후, 압출성형기를 이용하여 압출한 뒤 냉각 와인더 롤을 통해 두께 $12{\mu}m$의 대조구와 산화생분해 투명 바이오 필름을 제조하였다. 기계적 물성으로 인장강도, 연신율 및 최대하중연신율을 측정하였으며, 생분해 실험을 실시하였다. 식물체 유래 가소제, 생분해 촉매제로 제조된 투명 바이오 필름은 대조구 대비 인장강도 및 연신율이 큰 차이가 없는 것으로 나타났다. 또한 ASTM D 6954-04 방법에 따라 45일간 생분해 테스트를 한 결과 표준물질인 셀룰로오스 분말 대비 61.4%의 생분해를 나타내었다.

율무의 기계수확(機械收穫) 시기(時期)에 따른 수량성(收量性) (Yield Variation in Different Harvest Time of Coix lachryma L. var. Ma-yuen STAPF)

  • 이은섭;이준석;김기중;이효승
    • 한국약용작물학회지
    • /
    • 제5권4호
    • /
    • pp.284-288
    • /
    • 1997
  • 농가(農家)에 보급(普及)된 수도용(水稻用) 콤바인의 이용효율(利用效率)을 높이고 농가소득 증대(農家所得 增大)에 기여(寄與)하기 위해 율무의 콤바인 수확적기(收穫適期)를 구명(究明)하고자 수확시기(收穫時期)를 개화기후(開花期後) 40일, 50일, 00일, 70일에 실시(實施)하시여 얻은 결과(結果)를 요약(要約)하면 다음과 같다. 1. 작업효율(作業效率)은 개화기후(開花期後) 50일 이후(以後)에는 2조 수확(收穫)) 가능(可能)하였고, 작업속도(作業速度)는 개화기후(開花期後) 50일 이후(以後)에는 0.26m/s였고 이론상의 작업능력(作業能力)은 개화기후(開花期後) 60日 이후(以後)는 11.23a/hr였다. 2. 수분함량(水分含量)은 수확시기(收穫時期)가 늦어질수록 낮아져 경엽(莖葉)의 수분함량(水分含量)은 $69.7{\sim}55.3%$ 였고, 종실(種實)의 수분함량은 개화기후(開花期後) 60일 이후(以後)에는 34.2%정도로 안정 되었다. 3. 수확시기(收穫時期)가 늦어질수록 등숙립(登熟粒)은 증가(增加)하였고, 미숙립(未熟粒)과 검불은 감소(減少)하였는데, 개화기후(開花期後) 60일 이후(以後)에는 검불의 혼입율이 1.8%미만이었다. 4. 개화기후 40일부터 70일까지 10일 간격으로 조사한 결과, l 중은 수확시기(收穫時期) 가 늦어질수록 무거워졌으나, 10a당(當) 종실수량(種實收量)은 개화기후(開花期後) 60일에서 가장 무거웠다. 5. 율무의 수도용(水稻用) 콤바인을 이용한 수확적기(收穫適期)는 회귀분석(回歸分析) 결과(結果) 개화기후(開花期後) 68 일경(日頃)이었다.

  • PDF