• Title/Summary/Keyword: Mach-Zehnder 간섭계

Search Result 96, Processing Time 0.025 seconds

The visibility variation of the mach-zehnder optical fiber interferometerdue to birefringences, input states of polarization and optical losses (복굴절, 입력 편광상태 및 광손실이 광섬유간섭계의 visibility에 미치는 영향)

  • 강현서;이영택;이경식
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.2
    • /
    • pp.140-147
    • /
    • 1996
  • The output of the mach-zehnder optical fiber interferometer varies with birefringences existing in the figer arms. New equations experessing for the visibility of the mach-zehnder interferometer were derived in terms of a number of parameters related to the birefringences, the input SOP and the optical losses. Based on the equations the visibility of the interferometer was simulated in different cases. Some maximum visibility conditons were also presented.

  • PDF

Humidity Sensor using Polyvinylpyrrolidone-Coated Mach-Zehnder Interferometer in Planar Lightwave Circuit (폴리비닐피롤리돈이 코팅된 마하젠더 간섭계 기반의 평판형 광도파로 습도센서)

  • Kim, Ju Ha;Kim, Myoung Jin;Jung, Eun Joo;Hwang, Sung Hwan;Lee, Woo Jin;Choi, Eun Seo;Rho, Byung Sup
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.251-255
    • /
    • 2013
  • In this paper, the characteristics of a humidity sensor implemented by Mach Zehnder Interferometer (MZI) in a Planar Lightwave Circuit (PLC) have been designed and demonstrated. The humidity outside is detected with polyvinylpyrrolidone (PVP) coated on the etched arm of the MZI. The length of the etched arm is 10 mm and the PVP was coated by dip-coating into the etched region. As the refractive index of the PVP changes with the surrounding humidity, the PVP-coated humidity sensor presented changes in the interferogram depending on RH (Relative Humidity) around the PLC. The measured results show that the proposed humidity sensor works successfully in the range of 30% to 80% of RH.

Fiber-optic Mach-Zehnder Interferometer for the Detection of Small AC Magnetic Field (미소 교류 자기장 측정을 위한 Mach-Zehnder 광섬유 간섭계 자기센서 특성분석)

  • 김대연;안준태;공홍진;김병윤
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.139-148
    • /
    • 1991
  • A fiber-optic magnetic sensor system for the detection of small ac magnetic field(200Hz-2 kHz) was constructed. Magnetic field sensing part was fabricated by bonding a section of optical fiber to amorphous metallic glass(2605SC) having large magnetostriction effect. And with the directional coupler, all fiber type Mach-Zehnder interferometer was constructed to measure the variation of the external magnetic field by translating it into the optical phase shift in the interferometer. The signal fading problem of the interferometer, which is due to random phase drifts originated from the environment, i.e., temperature fluctuation, vibrations, etc., was elliminated by feedback phase compensation. This allows the sensitivity to be maintained at the maximum by keeping the interferometer in quadrature phase condition. The frequency response of metallic glass was found to be nearly flat in the range of 90 Hz-2 kHz and dc bias field for the maximum ac response was 3.5 Oe. The interferometer output showed good linearity over the range $\pm$0.5 Oe. For 1 kHz ac magnetic field the scale factor S and the minimum detectable magnetic field were measured to be 8.0 rad/Oe and $3X10^{-6} Oe/\sqrt{Hz}$at 1 Hz detection bandwidth respectively.

  • PDF

FBG Sensor Demodulation Using a Double-Pass Mach-Zhender Interferometer (더블패스 마하젠더 간섭계를 이용한 광섬유 격자 센서의 파장복조)

  • Park, Hyoung-Jun;Song, Min-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.285-290
    • /
    • 2007
  • A wavelength-demodulation algorithm for FBG sensor is proposed by using a double-pass Mach-Zehnder interferometer. Zero-crossing points of double-passed interference signal are used to trigger the accurate $90^{\circ}C$ phase difference positions in the sensor signal, which is an essential condition in the subsequent arctangent and phase unwrapping signal processing. With the proposed method, we could efficiently measure various measurands, such as dynamic-, static-strain, and temperature, and ${\sim}8pm$ of wavelength resolution was obtained.

All-fiber heterodyne interferometer with phase modulation (Mach-Zehnder 광섬유 간섭계를 이용한 Heterodyne 검파 방법)

  • Jeong, Kyu-Cheol;Song, Jung-Tae;Lee, Kyung-Shik
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.996-998
    • /
    • 1998
  • We have proposed and demonstrated a novel method of heterodyne detection using all-fiber Mach-Zehnder interferometer. The method is characterized by the phase modulation with a sawtooth waveform instead of a frequency modulation in true heterodyne. The experimental results will be compared with the expected results.

  • PDF

Digital Watermarking using Phase hologram and Optical Interferometer (위상 홀로그램과 광학적 간섭계를 이용한 디지털 워터마킹)

  • 김병열;조규보;신창목;서동환;김수중
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.87-90
    • /
    • 2002
  • A digital watermark is an invisible mark embedded in a digital image which used for copyright protection. In this paper, we propose a new optical watermarking system. A optical watermarking system is applied for digital watermarking by phase hologram and Mach-Zehnder interferometer. A optical watermarking technique to be hidden is phase modulated in a random patten, and its Fourier-transformed hologram image is superposed on a content image. The autentication information extract by using Mach-zehnder interferometer.

  • PDF

Digital Watermarking using Phase hologram and Optical Interferometer (위상 홀로그램과 광학적 간섭계를 이용한 디지털 워터마킹)

  • 김병열;조규보;신창목;서동환;김수중
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.227-230
    • /
    • 2002
  • A digital watermark is an invisible mark embedded in a digital image which used for copyright protection. In this paper, we propose a new optical watermarking system. A optical watermarking system is applied for digital watermarking by phase hologram and Mach-Zehnder interferometer. A optical watermarking technique to be hidden is phase modulated in a random patten, and its Fourier-transformed hologram image is superposed on a content image. The autentication information extract by using Mach-zehnder interferometer.

  • PDF

Temperature Measurement Using Single-Mode Fiber Interferometric Sensor (단일모드 광섬유의 간섭계 센서를 이용한 온도측정)

  • 김덕수;이상호
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.2
    • /
    • pp.1-5
    • /
    • 1985
  • In this paper, temperature-induced optical phase shifts in single-mode fibers are studied both analytically and experimentally. Temperature sensor using single-mode fiber interferometer is designed and the temperature sensitivity of the sensor system is investigated. This fiber-optic temperature sensor which employs the Mach-Zehnder arrangement is a high sensitivity sensor of phase detection type. In this type, temperature changes are ob-served as a motion of an optical interference fringe pattern. In the measurements using interferometer, one of the important problems is to detect simultaneously the number and direction of fringe displacement resulting from physical perturbations (temperature, pressure, etc.). To realize this, the array detector using multi-mode fiber is designed. By this array detector the number and direction of fringe displacement is Ineasured very conveniently.

  • PDF

Optical Implementation of Incoherent Holographic 3D Display System using Modified Triangular and Mach-Zehender Interferometer (변형된 삼각 및 마하젠더 간섭계 기반의 인코히어런트 홀로그래픽 3D 디스플레이 시스템의 광학적 구현)

  • 김승철;구정식;김은수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.4C
    • /
    • pp.524-532
    • /
    • 2004
  • In this paper, an incoherent holographic 3D imaging and display system based on the modified triangular and Mach-Zehnder interferometers is optically implemented and some experiments are carried out. Incoherent hologram of a 3D object is generated by using the hologram input system of modified triangular interferometer. Then this complex hologram is reconstructed by using the hologram output system of modified Mach-Zehnder interferometer in which two LCD spatial light modulators and a waveplate are inserted. From the experiment with two point sources having a depth difference of 100 mm each other, it is revealed that each point source can be independently reconstructed at its own focal position from the complex hologram, while both of the bias and conjugate image are simultaneously eliminated at the same time. And in the experiment with the real 3D object of two dices having a depth difference of 30 mm each other, it is also conformed that the bias and conjugate image can be effectively eliminated from the hologram pattern and each 3D dice can be also successfully reconstructed at its own focal position from the complex hologram. These experiment results finally suggest a possibility of implementing a new incoherent holographic 3D imaging and display system using the modified triangular and Mach-Zehender interferometers.

Comparison of Signal to Noise Ratios in different configulation of optical coherence tomography systems (간섭계 형태에 따른 광단층 촬영장치의 SNR 비교)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.804-806
    • /
    • 2004
  • As a noninvasive imaging meathod, optical coherence tomography system has been extensively studied because it has some advantage such as imaging of high resolution, low cost, and compace size configuration. The optical power of the sample signal reflected from an object is usually very small in optical coherence tomography(OCT) due to absorption and scattering in a sample material. Furthermore, there happens a serious loss of sample signal power in a fiber coupler because it does not transfer to a photodetector but return to the optical source. In order to improve the SNR of OCT system, basic Michelson and Mach-Zehnder interferometer types were configured then, we compared simulation with measurement of reference sample Therefore, an On in configuration of Math-Zehnder interferometer was demonstrated in order to improve the signal to noise ratio

  • PDF