• Title/Summary/Keyword: MX

Search Result 325, Processing Time 0.028 seconds

Studies on Intracellular Functions of the mas3 Gene in the Fission Yeast, Schizosaccharomyces pombe (분열형 효모에서 mas3 유전자의 세포내 기능 연구)

  • Hwang Mi Ra;Cha Jae Young;Shin Sang Min;Park Jong Kun
    • Journal of Life Science
    • /
    • v.15 no.1 s.68
    • /
    • pp.124-131
    • /
    • 2005
  • The regulation of gene expression plays an important rolet in cell cycle controls. In this study, a novel $mas3^+$ (mitosis associated protein) gene, a homolog of human SMARCADl, was isolated and characterized from a fission yeast Schizosaccharomyces pombe. The overall homology between the helicase proteins of the two species is $87\%$. This DEAD/H box-containing molecule has seven highly conserved sequence regions that allow us to place it in the SNF2 family of the helicase superfamily. Knock-out cell of $mas3^+$ gene was constructed using kanMX6 as a selection marker. Survival of mas3 null mutant exposed to UV or MMS was similar to those of wild type cells. $mas3^+$ expression was lowest at $G_2$ and gradually increased. Cytokinesis of mas3 null mutant was abnormal at $26^{\circ}C\;and\;35^{\circ}C$ and a large number of multi-septate cells were produced. These results indicate that the $mas3^+$ is involved in cytokinesis and cell shape control.

Prevalence and Distribution of Congenitally Missing Teeth in Patients Visiting the Department of Pediatric Dentistry of Chonbuk National University Hospita (전북대학교병원 소아치과에 내원한 어린이에서 선천적으로 결손된 치아의 유병률 및 분포)

  • Jeon, Hyunsoon;Yang, Yeonmi;Baik, Byeongju;Kim, Jaegon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.4
    • /
    • pp.274-282
    • /
    • 2013
  • The goal of this study was to analyze prevalence and distribution of congenitally missing teeth in 3302 patients from 7 to 15 years old, who had visited and taken panoramic radiographs at the Department of Pediatric Dentistry, from January 2008 to December 2012. The prevalence of hypodontia in the males (5.9%) was slightly higher than in the females (4.7%). In the affected patients, the mean number of congenitally missing teeth in the mandible was statistically higher than in the maxilla (p < 0.05). However, there was no significant difference in the number of congenitally missing teeth between left and right dentitions (p > 0.05). Excluding the Mn. third molars, the most frequent congenitally missing teeth site was the Mn. second premolars. In contrast, the most infrequent congenitally missing teeth sites were the Mx. and Mn. first premolars, and Mx. central incisors. The bilateral combination or antagonistic quadrants combination of congenitally missing teeth in hypodontia patients was 80.3%. The result of this study will contribute to clinicians to make accurate diagnosis and establish favorable treatment plans, by offering invaluable data about the number and distribution of congenitally missing teeth.

The Study of Implant Patient's Type and Implant Distribution (임플란트 환자의 유형 및 분포에 대한 연구)

  • Hong, Sung-Jae;Paik, Jeong-Won;Kim, Chang-Sung;Choi, Seong-Ho;Lee, Keun-Woo;Chai, Jung-Kiu;Kim, Chong-Kwan;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.539-554
    • /
    • 2002
  • It has been approximately 40 years since $Br{{\aa}}nemark$ first introduced osseo-integration for implants in the early 1960s. Unlike crown and bridge or denture treatment, implant treatment helps preserve existing bone and improve masticatory functions. Thus, the awareness of implant treatment has grown rapidly among dentists and patients alike in Korea, as it becomes a widely accepted treatment. The following results on patients type and implant distribution were compiled from 1814 implant cases of 640 patients treated at the periodontal dept. of Y University Hospital during 1992 to 2001. 1. There are no dissimilarities between men and women, with patients in their 40,50s accounting for 49% of patients and 56% of implant treatments; the largest share of patients and implant treatments. 2. Mn. posterior area accounted for 59% of implant treatments followed by Mx. posterior area(21%), Mx anterior area(l4%) and Mn anterior area 2%. 3. Partial edentulous patients treated by single crown and bridge-type prosthesis accounted for 98% and fully edentulous patient accounted for the remaining 2% 4. The major cause of tooth loss is periodontal disease, followed by dental caries, trauma and congenital missing. Compared to women, men are more likely to suffer from tooth loss due to periodontal disease. Also, older people are more likely to suffer from tooth loss due to periodontal disease rather than dental caries. 5. The distribution of bone quality for maxillae was 52% for type III, followed by 23% for type II, 20% for type IV and 0% for type I. As for mandible, the distribution was 52% for type II, followed by 37% for type III, 7% for type IV and 4% for type I. 6. The distribution of bone quantity for maxillae was 49% for type C, followed by 34% for type B, 14% for type D, 3% for type A, and 0% for type E. As for mandible, the distribution was 52% for type B, followed by 35% for type C, 6% for type D, 3% for type A and 0% for type E. 7. The majority of implants were those of 10-14mm in length (80%) and regular diameter in width (79%). The results provided us with basic data on patient type, implant distribution, bone condition, etc. We wish that our results coupled with other research data helps assist in the further study for better implant success/survival rates, etc.

Noise Characteristics of 64-channel 2nd-order DROS Gradiometer System inside a Poorly Magnetically-shielded Room (저성능 자기차폐실에서 64채널 DROS 2차 미분계 시스템의 잡음 특성)

  • Kim, J.M.;Lee, Y.H.;Yu, K.K.;Kim, K.;Kwon, H.;Park, Y.K.;Sasada, Ichiro
    • Progress in Superconductivity
    • /
    • v.8 no.1
    • /
    • pp.33-39
    • /
    • 2006
  • We have developed a second-order double relaxation oscillation SQUID(DROS) gradiometer with a baseline of 35 mm, and constructed a poorly magnetically-shielded room(MSR) with an aluminum layer and permalloy layers for magnetocardiography(MCG). The 2nd-order DROS gradiometer has a noise level of 20 $fT/{\surd}Hz$ at 1 Hz and 8 $fT/{\surd}Hz$ at 200 Hz inside the heavily-shielded MSR with a shielding factor of $10^3$ at 1 Hz and $10^4-10^5$ at 100 Hz. The poorly-shielded MSR, built of a 12-mm-thick aluminum layer and 4-6 permalloy layers of 0.35 mm thickness, is 2.4mx2.4mx2.4m in size, and has a shielding factor of 40 at 1 Hz, $10^4$ at 100 Hz. Our 64-channel second-order gradiometer MCG system consists of 64 2nd-order DROS gradiometers, flux-locked loop electronics, and analog signal processors. With the 2nd-order DROS gradiometers and flux-locked loop electronics installed inside the poorly-shielded MSR, and with the analog signal processor installed outside it, the noise level was measured to be 20 $fT/{\surd}Hz$ at 1 Hz and 8 $fT/{\surd}Hz$ at 200 Hz on the average even though the MSR door is open. This result leads to a low noise level, low enough to obtain a human MCG at the same level as that measured in the heavily-shielded MSR. However, filters or active shielding is needed fur clear MCG when there is large low-frequency noise from heavy air conditioning or large ac power consumption near the poorly-shielded MSR.

  • PDF

Establishing the Concept of Buffer for a High-level Radioactive Waste Repository: An Approach (고준위폐기물처분장의 완충재 개념 도출: 접근방안)

  • Lee, Jae Owan;Lee, Minsoo;Choi, Heuijoo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.4
    • /
    • pp.283-293
    • /
    • 2015
  • The buffer is a key component of the engineered barrier system in a high-level radioactive waste (HLW) repository. The present study reviewed the requirements and functional criteria of the buffer reported in literature, and also based on the results, proposed an approach to establish a buffer concept which is applicable to an HLW repository in Korea. The hydraulic conductivity, radionuclide-retarding capacity (equilibrium distribution coefficient and diffusion coefficient), swelling pressure, thermal conductivity, mechanical properties, organic carbon content, and illitization rate were considered as major technical parameters for the functional criteria of the buffer. Domestic bentonite (Ca-bentonite) and, as an alternative, MX-80 (Na-bentonite) were proposed for the buffer of an HLW repository in Korea. The technical specifications for those proposed bentonites were set to parameter values that conservatively satisfy Korea's functional criteria for the Ca-bentonite and Swedish criteria for the Na-bentonite. The thickness of the buffer was determined by evaluating the means of shear behavior, radionuclide release, and heat conduction, which resulted in the proper buffer thickness of 0.25 to 0.5 m. However, the final thickness of the buffer should be determined by considering coupled thermal-hydraulic-mechanical evaluation and economics and engineering aspects as well.

Development of Novel Joint Device for a Disposal Canister in Deep Borehole Disposal (고준위폐기물 심부시추공 처분을 위한 처분용기 접속장치의 개발)

  • LEE, Minsoo;LEE, Jongyoul;JI, Sung-Hoon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.2
    • /
    • pp.261-270
    • /
    • 2018
  • In this study, to replace the 'J-slot joint', a joint device between a disposal canister and an emplacement jig in Deep Borehole Disposal process, a novel joint device was designed and tested. The novel joint device was composed of a wedge on top of a disposal canister and a hook box at the end of a winch system. The designed joint device had merits in that it can recombine an emplaced canister freely without the replacement of the joint component. Moreover, it can be applied to various emplacement jigs such as drill pipes, wire-lines, and coiled tubing. To demonstrate the designed joint device, the joint device (${\Phi}110mm$, H 148 mm), a twin canister string (${\Phi}140mm$, H 1,105 mm), and a water tube (${\Phi}150mm$, H 1,500 mm) as a borehole model were manufactured at 1/3 scale. As deployment muds, Na-type bentonite (MX-80) and Ca-type (GJ II) bentonite muds were prepared at solid contents of 7wt% and 28wt%, respectively. The manufactured joint device showed good performance in pure water and viscous muds, with an operation speed of $10m{\cdot}min^{-1}$. It was concluded that the newly developed joint device can be used for the emplacement and retrieval of a deep disposal canister, below 3~5 km, in the future.

Antimicrobial Resistance of Organisms Isolated from Clinical Specimens (임상재료에서 분리한 각종세균의 항균제내성)

  • Suh, Seong-Il;Park, Jong-Wook;Chun, Do-Ki
    • The Journal of the Korean Society for Microbiology
    • /
    • v.22 no.3
    • /
    • pp.283-294
    • /
    • 1987
  • One hundred and fifty-seven strains of staphylococci isolated from various clinical specimens and 80 of Gram-negative bacilli from urine of patients with urological diseases were tested for resistance to antimicrobial drugs by microdilution broth method. Among staphylococci, 50 to 89% of the strains were resistant to gentamicin(Gm), kanamycin(Km), erythromycin(Em), nalidixic acid(Na), and tetracycline. Ninety per cent MIC was lowest in ciprofloxacin(Cp), followed by vancomycin(Vc), trimethoprim(Tp), enoxacin(Ex), and norfloxacin(Nf) with the values of two ${\mu}g/ml$ or lower. Twenty-seven strains were resistant to methicillin(MR), with 24 strains of Staphylococcus aureus and 3 of S. epidermidis. All strains of MR S. aureus were resistant to oxacillin, rifampin(Rf), Gm, Km, Em, Na, and Tc, and no strain was resistant to Vc and Tp. Almost all staphylococci isolated from urine were S. epidermidis and sensitive to most drugs tested without MR strain. Among Gram-negative bacilli from urine, Escherichia coli(43 strains) was most frequently isolated, and followed by Klebsiella spp.(11), Proteus spp.(10), Serratia spp.(10), and Pseudomonas aeruginosa(6) in the decreasing order. The majority of E. coli and Serratia spp. were resistant to chloramphenicol(Cm), Tc, streptomycin, sulfisomidine(Su), ampicillin(Ap), Km, and carbenicillin(Cb), and 50 and 90% MICs of these drugs were also high. In Klebsiella spp., 54% or more were resistant to Cm, Su, Ap, cephalothin, and Cb. Proteus spp. were susceptible to most drugs tested, but Pseudomonas were resistant to nearly all drugs tested except Rf, amikacin, and moxalactam(Mx). All Gram-negative bacilli tested were found to be susceptible to Mx. New quinolone carboxylic acid compounds, such as Nf, Ex, and Cp showed very high antimicrobial activities against the majority of organisms tested except Pseudomonas, and 50 and 90% MICs of Nf and Ex were always equal or 2 to 4 times higher than Cp. Organisms multiply resistant to drugs were noted in almost all isolates tested. Twenty-seven strains of staphylococci were multiply resistant to 11 or more drugs, and 6 of Klebsiella spp. to 8 to 11 drugs. The most frequent multiplicity of durg resistance were 7 and 8, 12, and 13 in E. coli, Serratia spp., and Pseudomonas, respectively. No strain was resistant to more than 5 drugs in Proteus spp..

  • PDF

Exosome-mediated delivery of gga-miR-20a-5p regulates immune response of chicken macrophages by targeting IFNGR2, MAPK1, MAP3K5, and MAP3K14

  • Yeojin Hong;Jubi Heo;Suyeon Kang;Thi Hao Vu;Hyun S. Lillehoj;Yeong Ho Hong
    • Animal Bioscience
    • /
    • v.36 no.6
    • /
    • pp.851-860
    • /
    • 2023
  • Objective: This study aims to evaluate the target genes of gga-miR-20a-5p and the regulated immune responses in the chicken macrophage cell line, HD11, by the exosome-mediated delivery of miR-20a-5p. Methods: Exosomes were purified from the chicken macrophage cell line HD11. Then, mimic gga-miR-20p or negative control miRNA were internalized into HD11 exosomes. HD11 cells were transfected with gga-miR-20a-5p or negative control miRNA containing exosomes. After 44 h of transfection, cells were incubated with or without 5 ㎍/mL poly(I:C) for 4 h. Then, expression of target genes and cytokines was evaluated by quantitative realtime polymerase chain reaction. Results: Using a luciferase reporter assay, we identified that gga-miR-20a-5p directly targeted interferon gamma receptor 2 (IFNGR2), mitogen-activated protein kinase 1 (MAPK1), mitogen-activated protein kinase kinase kinase 5 (MAP3K5), and mitogen-activated protein kinase kinase kinase 14 (MAP3K14). Moreover, the exosome-mediated delivery of gga-miR-20a-5p successfully repressed the expression of IFNGR2, MAPK1, MAP3K5, and MAP3K14 in HD11 cells. The expressions of interferon-stimulated genes (MX dynamin like GTPase 1 [MX1], eukaryotic translation initiation factor 2A [EIF2A], and oligoadenylate synthase-like [OASL]) and proinflammatory cytokines (interferon-gamma [IFNG], interleukin-1 beta [IL1B], and tumor necrosis factor-alpha [TNFA]) were also downregulated by exosomal miR-20a-5p. In addition, the proliferation of HD11 cells was increased by exosomal miR-20a-5p. Conclusion: The exosome-mediated delivery of gga-miR-20a-5p regulated immune responses by controlling the MAPK and apoptotic signaling pathways. Furthermore, we expected that exosomal miR-20a-5p could maintain immune homeostasis against highly pathogenic avian influenza virus H5N1 infection by regulating the expression of proinflammatory cytokines and cell death.

CKFont2: An Improved Few-Shot Hangul Font Generation Model Based on Hangul Composability (CKFont2: 한글 구성요소를 이용한 개선된 퓨샷 한글 폰트 생성 모델)

  • Jangkyoung, Park;Ammar, Ul Hassan;Jaeyoung, Choi
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.11 no.12
    • /
    • pp.499-508
    • /
    • 2022
  • A lot of research has been carried out on the Hangeul generation model using deep learning, and recently, research is being carried out how to minimize the number of characters input to generate one set of Hangul (Few-Shot Learning). In this paper, we propose a CKFont2 model using only 14 letters by analyzing and improving the CKFont (hereafter CKFont1) model using 28 letters. The CKFont2 model improves the performance of the CKFont1 model as a model that generates all Hangul using only 14 characters including 24 components (14 consonants and 10 vowels), where the CKFont1 model generates all Hangul by extracting 51 Hangul components from 28 characters. It uses the minimum number of characters for currently known models. From the basic consonants/vowels of Hangul, 27 components such as 5 double consonants, 11/11 compound consonants/vowels respectively are learned by deep learning and generated, and the generated 27 components are combined with 24 basic consonants/vowels. All Hangul characters are automatically generated from the combined 51 components. The superiority of the performance was verified by comparative analysis with results of the zi2zi, CKFont1, and MX-Font model. It is an efficient and effective model that has a simple structure and saves time and resources, and can be extended to Chinese, Thai, and Japanese.

Development of a Six-Axis Force/Moment Sensor with Rectangular Taper Beams for an Intelligent Robot

  • Kim, Gab-Soon
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.4
    • /
    • pp.419-428
    • /
    • 2007
  • This paper describes the development of a six-axis force/moment sensor with rectangular taper beams for an intelligent robot's wrist and ankle. In order to accurately push and pull an object with an intelligent robot's hand, and in order to safely walk with an intelligent robot's foot, the robot's wrist and ankle should measure three forces Fx, Fy, and Fz, and three moments Mx, My, and Mz simultaneously from the mounted six-axis force/moment sensor to the intelligent robot's wrist and ankle. Unfortunately, the developed six-axis force/moment sensor utilized in other industrial fields is not proper for an intelligent robot's wrist and ankle in the size and the rated output of the six-axis force/moment sensor. In this paper, the structure of a six-axis force/moment sensor with rectangular taper beams was newly modeled for an intelligent robot's wrist and ankle, and the sensing elements were designed by using the derived equations, following which the six-axis force/moment sensor was fabricated by attaching strain-gages on the sensing elements. Moreover, the characteristic test of the developed sensor was carried out by using the six-component force/moment sensor testing machine. The rated outputs from the derived equations agree well with those from the experiments. The interference error of the sensor is less than 2.87%.