• Title/Summary/Keyword: MUF

Search Result 45, Processing Time 0.024 seconds

Effect of Modified Ultrafiltration on the Postoperative State after Pediatric Open Heart Surgery. (소아 개심술에 있어서 변형 초여과법(Modified Ultrafiltration)이 술후 상태에 미치는 영향)

  • 방종경;천종록;김규태
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.456-465
    • /
    • 1998
  • Cardiopulmonary bypass(CPB) in children is associated with the accumulation of body water after cardiac operation, as a consequence of an inflammatory capillary leak. Following work by Elliott in 1991, modified ultrafiltration(MUF) was introduced after bypass as a means of hemoconcentrating patients and a potential way of removing water from the tissues. We have carried out a prospective randomized study of 20 children undergoing open heart surgery, comparing MUF with nonfiltered controls. MUF was carried out for a mean of 18.9 minutes after completion of CPB to a hematocrit of 37.1%(mean). The mean water volulme removed by the ultrafiltration was 38.4 ml/kg and the mean blood volume retransfused from the oxygenator during the ultrafiltration was 32.1 ml/kg. Fluid balance, hemodynamics, hematocrit, osmolarity and dosage of drug treatment were recorded for 4∼12 hours postoperatively. The results were analyzed using Student t-test and ANOVA, comparing controls(n=10) to MUF(n=10). Blood loss(ml/kg/24hr) was 14.5(mean) in MUF versus 13.7 in controls; blood transfused(ml/kg/24hr) 6.6 in MUF versus 15.2 in controls; plasma transfused(ml/kg/24hr) 65.7 in MUF versus 59.6 in controls. There was rise in arterial blood pressure and hematocrit during MUF. Percent rise of systolic blood pressure was 28.8% in MUF versus 18.7% in controls(p=0.366); percent rise of diastolic blood pressure was 28.8% in MUF versus 8.5% in controls(p=0.135); and percent rise of mean blood pressure was 36.2% in MUF versus 8.2% in controls (p=0.086). Percent rise of hematocrit was 40.0% in MUF versus 23.5% in controls(p=0.002). There was no significant difference in the inotropic requirement and the postoperative serum osmolarity between two groups. The number of days on the ventilator, the duration of stay in the intensive care unit, and the postoperative hospital stay were not significantly different between the two groups.

  • PDF

Microbial Extracellular Enzyme Detection on Agar Plates by Means of Fluorogenic Methylumbelliferyl-Substrates (Methylumbelliferyl 형광기질을 이용한 평판배지상의 미생물 체외 세포효소측정방법)

  • ;Hoppe, H.-G.
    • Korean Journal of Microbiology
    • /
    • v.28 no.3
    • /
    • pp.229-235
    • /
    • 1990
  • A rapid and sensitive method to detect the extracellular enzymatic activity of bacteria colonies grown on agar plates is described. Selective agar media supplemented with protein, starch, chitin, Tween-80, etc. are conventionally used to detect biochemical properties of bacteria. It has been experimentally demonstrated with bacteria pure cultures that fluorogenic Methylumbelliferyl (MUF)-substrates are excellent substrate analogues for normally occurring polymers. Based on MUF-substrate hydrolysis the new method provides reliable qualitative estimates of extracellular enzymatic properties of bacteria within minutes using pure cultures as well as agar p;ates prepared for colony counts. Extracellular enzyme activities of heterotrophic bacteria from freshwater ecosystems and marine sediment using this method are discussed.

  • PDF

The MUF of a Pilot-Scaled ACP Facility and Its Sensitivity

  • W. I. Ko;D. Y. Song;Lee, S. Y.;Kim, H. D.;Park, S. W.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.401-405
    • /
    • 2003
  • The Advanced Spent Fuel Conditioning Process (ACP) have been developed at the Korea Atomic Energy Research Institute (KAERI) as an alternative for the effective conditioning of spent fuel far long-term storage or/and eventual disposal. This paper addresses the safeguardability of a pilot-scaled ACP facility and its sensitivity analysis. For this, a conceptual process and its material flow are analyzed using experiences from conventional fuel cycles, and measurement methods and their uncertainties are assumed for calculating MUF (Material Uncounted For) standards deviation (SD), We concluded from the preliminary analysis of the MUF SD that the pilot-scaled ACP facility with capacity of 30 MTHM/year can meet the International Atomic Energy Agency (IAEA) safeguards goals.

  • PDF

Isolation and Phylogenetic Characterization of Chitinase Producing Oligotrophic Bacteria (Chitinase생산 저영양세균의 분리 및 계통분류학적 특성)

  • Kim Soo-Jin;Kim Min-Young;Koo Bon-Sung;Yoon San-Hong;Yeo Yun-Soo;Park In-Cheol;Kim Yoon-Ji;Lee Jong-Wha;Whang Kyung-Sook
    • Korean Journal of Microbiology
    • /
    • v.41 no.4
    • /
    • pp.293-299
    • /
    • 2005
  • Many isolates from soil of Korean ginseng rhizosphere did not show remarkable growth on full strength of the conventional nutrient broth (NB medium) but grew on its 100-fold dilution (DNB medium). Six hundred-forty strains were isolated as oligotrophic bacteria. In the course of screening for new bioactive compounds from oligotrophic bacteria from soil, 8 strains which had appeared to form of clear zone on a medium containing colloidal chitin as a sole carbon source were selected for further studies. Strain CR42 hydrolyzed a fluorogenic analogue of chitin, 4-methylumbelliferyl-D-glucosaminide (MUF-NAG) . Mo st of the culture supernatant of these isolates hydrolyzed 4-methylumbelliferyl-D-N,N'-diacetylchitobioside (MUF-diNAG). The isolates were heterogeneous and categorized to gamma- and beta-proteobacteria, Bacillaceae, Actinobactepia, and Bacteroides by 16S rRNA analysis. Two strains, WR164 and CR18, had a 16S rRNA sequence of $95-96\%$ identical to uncultured bacteria. It was observed that CR2 and CR75 could inhibit the growth of Colletotrichum gloeosporioides with hyphal extention-inhibition assay on PDA plate supplemented with $1\%$ colloidal chitin.

An Automated Management System for MUF (초음파 다 회선 유량계(MUF)의 무인 관리 시스템 개발)

  • Kim, Hyung-Chul;Jang, Hyuk-Soo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.05b
    • /
    • pp.971-974
    • /
    • 2003
  • 본 논문은 초음파 다 회선 유량계로부터 추출된 정밀 정보를 활용하여 무인 관리 시스템을 개발하였다. 성능을 최대한 발휘 할 수 있도록 LabVIEW라는 그래픽 기반의 프로그래밍 언어를 사용하였고 IsaTrol, IsaGrape와 같은 장비로부터 추출한 디지털 데이터를 컴퓨터로 전송하는 플랫폼을 완성하였다.

  • PDF

Characteristics of Low Density Fiberboards for Insulation Material with Different Adhesives (I) - Thermal Insulation Performance and Physical Properties - (다양한 접착제로 제조한 단열재용 저밀도섬유판의 특성(I) - 단열성능 및 물리적 성질 -)

  • Jang, Jae-Hyuk;Lee, Min;Kang, Eun-Chang;Lee, Sang-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.3
    • /
    • pp.360-367
    • /
    • 2017
  • This study was carried out to compare the characteristics of low density fiberboards (LDFs) manufactured with different adhesive types such as melamine urea formaldehyde (MUF), phenol formalehyde (PF), emulsified MDI (eMDI) and latexes resins. As results, hard LDFs were successfully manufactured by MUF, PF and eMDI resins. Thermal conductivities of all LDFs were significantly lower than commercial medium density fiberboard. Especially, all LDFs showed comparable thermal insulation performance with extruded polystyrene foam (XPS). LDF manufactured with eMDI resins showed the highest physical properties such as thickness/length swelling by water absorption and bending strength.

Characteristics of Low Density Fiberboards Bonded with Different Adhesives for Thermal Insulation (II) - Formaldehyde·Total Volatile Organic Compounds Emission Properties and Combustion Shapes - (다양한 접착제로 제조한 단열재용 저밀도섬유판의 특성(II) - 폼알데하이드·총휘발성유기화합물 방출 특성 및 연소 형상 -)

  • Jang, Jae-Hyuk;Lee, Min;Kang, Eun-Chang;Lee, Sang-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.580-587
    • /
    • 2017
  • Woodfiber insulation board can be considered as a one of the key material for low energy consumption, comfortable and safety construction of residential space because of its eco-friendly and high thermal insulation performance. This study was carried out to investigate the formaldehyde (HCHO) total volatile organic compounds (TVOC) emission properties and combustion shapes by flame test of low density fiberboards (LDFs) prepared with different adhesives. HCHO TVOC emission and combustion properties of LDFs prepared by melamine urea formaldehyde (MUF), phenol formaldehyde (PF), emulsified methylene diphenyl diisocyanate (eMDI) and latex resin adhesives were measured by desiccator method, 20 L chamber method, and flame test, respectively. As results, LDFs manufactured by MUF, eMDI and latex resin adhesives satisfied the Super $E_0$ grade of HCHO emission performance except PF resin. Furthermore, TVOC emission of all LDFs were satisfied the Korean indoor air quality standard (below $400{\mu}g/m^2{\cdot}h$). Especially, LDF with eMDI resin adhesive showed the lowest HCHO and TVOC emissivity, that $0.14mg/{\ell}$, $12{\mu}g/m^2{\cdot}h$, respectively. However, eMDI emitted the small amount ($3{\mu}g/m^2{\cdot}h$) of toluene in VOC components. In the flame test, LDF with MUF resin adhesives showed the most favorable shape after flame test compare to LDFs prepared other adhesives. Based on HCHO and TVOC emission, and combustion shapes, MUF resin adhesive may be recommended to prepare LDF for insulation purpose.

Installation Effects on the Characteristics of Multi-path Ultrasonic Flowmeter with Valve (밸브후단에서의 다회선 초음파 유량계의 특성변화)

  • Hwang, S. Y.;Seo, K. H.;Kim, B. C.;Kim, K. S.;Tyan, H. S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.65-74
    • /
    • 2000
  • A five path ultrasonic and/or magnetic flowmeter were installed after valve. Five path ultrasonic flowmeter were tested to obtain it's performance in a water flow standard system and magnetic flowmeter. It's varied with straight pipe length(nD), install direction and valve position. All the results are summerized. The multi-path flowmeters(MUF) showed up to $\pm0.5{\%}$ at a 2, 4, 8, 15D spacing : the MUF was significantly better than magnetic flowmeter at disturbed flow conditions.

  • PDF