• Title/Summary/Keyword: MS solution

Search Result 508, Processing Time 0.029 seconds

Measurement of Degree of Hydrolysis of a PA66/GF Composite using a py-GC/MS analysis

  • Lee, Jong-Young;Kim, Kwang-Jea
    • Elastomers and Composites
    • /
    • v.52 no.1
    • /
    • pp.59-68
    • /
    • 2017
  • The effect on the hydrolysis resistance properties by the addition of maleic anhydride grafted EMDM (MA-g-EPDM) and PP (MA-g-PP) to a PA66/GF composite was investigated with respect to the mechanical properties, thermal properties, and morphology. The degree of hydrolysis of the PA66/GF composite was measured using py-GC/MS analysis. When compared to the PA66/GFcomposite in MEG/water solution, the composites where MA-g-EPDM and MA-g-PP were added to PA66/GF showed a higher degree of hydrolysis resistance, impact strength, and thermal properties, whereas their tensile strength, tensile modulus, flexural strength and flexural modulus decreased. As immersion time in the solution increases, the rate of tensile strength drop of the MA-g-PP added composite appeared lower than that of the PA66/MA-g-EPDM/GF and PA66/GF composites. The py-GC/MS analysis confirmed the formation of PA66 hydrolysis reaction by products such as carboxylic acid and alkylamine with increasing immersion time.

Sensitive Determination of Felodipine in Human Plasma by LC-MS/MS

  • Kim, Ho-Hyun;Roh, Hyeon-Jin;Lee, He-Joo;Han, Sang-Beom
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.283.2-283.2
    • /
    • 2003
  • This study established a highly sensitive novel quantification method for detecting felodipine in human plasma using LC-MS/MS. The mobile phase used after degassing was composed of 1 mM ammonium acetate and acetonitrile (20:80, pH 6.0), with flow rate of 200 uL/min. One mL plasma were pipetted into glass tubes and spiked with 0.1 mL of internal standard solution. (omitted)

  • PDF

Determination of Glimepiride in Human Plasma by LC-MS/MS

  • Kim, Ho-Hyun;Roh, Hyeong-Jin;Lee, Hee-Joo;Han, Sang-Beom
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.282.1-282.1
    • /
    • 2003
  • This study established a sensitive novel Quantification method for detecting glimepiride in human plasma using LC-MS/MS for pharmacokinetic studies. The mobile phase used after degassing was composed of 10 mM ammonium acetate and acetonitrile (20:80, pH 3.0), with flow rate of 200uL/min. One mL plasma were pipetted into glass tubes and spiked with 0.1 mL of internal standard solution. (omitted)

  • PDF

Comparison of TLC and GC-MS Method in the Analysis of Dye Extracted from Madder Plant (꼭두서니 추출염료에 대한 TLC와 GC-MS 분석법의 비교 연구)

  • ;S. Kay Obendorf
    • The Research Journal of the Costume Culture
    • /
    • v.12 no.4
    • /
    • pp.579-590
    • /
    • 2004
  • This research was aimed to investigate and compare the effectiveness of TLC and GC-MS methods in the analysis of chromophoric substances extracted from madder plant. Alizarin and purpurin 0.3% solution were used as comparative standards; madder extraction was prepared by heating the solution of powdered madder at 80℃, pH 1.5, for 90 min. Best elution solvent for TLC in silica gel plate was toluene:ethyl acetate=9:1, which resulted in red and yellow spots from madder extraction each of which showed R/sub f/ values 0.32-0.43 and 0.07-0.11. Although the red spot in particular exhibited similar characteristics as standard purpurin in color, shape, and R/sub f/ values, the result was inconsistent throughout different TLC trials. GC-MS analysis showed only small amount of alizarin and no purpurin in the madder extraction. Other chromophoric substance such as 2-furancarboxaldehyde, 5-(hydroxymethyl)-, anthralin, and danthron were also detected in small amounts. The result indicated that TLC was less sensitive to detecting and identifying the natural dyestuff which is generally constituted with a number of similar but chemically different chromophoric substances.

  • PDF

MS/OR EDUCATIONAL SOFTWARE PACKAGES: ARE THEY EFFECTIVE TUTORING PROGRAMS\ulcorner

  • Kim, Eyong-B;Sangjin Yoo
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.5 no.3
    • /
    • pp.30-37
    • /
    • 2000
  • Management science/operations research (MS/OR) educational software packages are widely used at the present time. Those software packages are expected to help students understand MS/OR techniques better. However, MS/OR educational software packages are often used as computational tools to obtain model solutions efficiently rather than as the tutoring software packages. Several possible reasons for the lack of effective tutoring capacity in MS/OR educational software packages are identified in this paper. The authors believe that the deficiency of tutoring capacity in those software is mainly due to technological limitations (computers and artificial intelligence) and the MS/OR professionals' perception about those software packages. Given technological limitations, feasible design and development approaches are provided to improve the tutoring effectiveness of MS/OR educational software packages.

  • PDF

Plasma Phosphoproteome and Differential Plasma Phosphoproteins with Opisthorchis Viverrini-Related Cholangiocarcinoma

  • Kotawong, Kanawut;Thitapakorn, Veerachai;Roytrakul, Sittiruk;Phaonakrop, Narumon;Viyanant, Vithoon;Na-Bangchang, Kesara
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1011-1018
    • /
    • 2015
  • This study was conducted to investigate the plasma phosphoproteome and differential plasma phosphoproteins in cases of of Opisthorchis viverrini (OV)-related cholangiocarcinoma (CCA). Plasma phosphoproteomes from CCA patients (10) and non-CCA subjects (5 each for healthy subjects and OV infection) were investigated using gel-based and solution-based LC-MS/MS. Phosphoproteins in plasma samples were enriched and analyzed by LC-MS/MS. STRAP, PANTHER, iPath, and MeV programs were applied for the identification of their functions, signaling and metabolic pathways; and for the discrimination of potential biomarkers in CCA patients and non-CCA subjects, respectively. A total of 90 and 60 plasma phosphoproteins were identified by gel-based and solution-based LC-MS/MS, respectively. Most of the phosphoproteins were cytosol proteins which play roles in several cellular processes, signaling pathways, and metabolic pathways (STRAP, PANTHER, and iPath analysis). The absence of serine/arginine repetitive matrix protein 3 (A6NNA2), tubulin tyrosine ligase-like family, member 6, and biorientation of chromosomes in cell division protein 1-like (Q8NFC6) in plasma phosphoprotein were identified as potential biomarkers for the differentiation of healthy subjects from patients with CCA and OV infection. To differentiate CCA from OV infection, the absence of both serine/threonine-protein phosphatase 2A 56 kDa regulatory subunit beta isoform and coiled-coil domain-containing protein 126 precursor (Q96EE4) were then applied. A combination of 5 phosphoproteins may new alternative choices for CCA diagnosis.

Effect of Artificial Soils and Aqueous Solutions for Plantlet Acclimatization of Somatic Embryos of Aralia elata (두릅나무 체세포배 유래 소식물체의 순화에 미치는 배양토 및 공급액의 효과)

  • 문흥규;배찬호;김용욱;이재순;이재선
    • Korean Journal of Plant Tissue Culture
    • /
    • v.28 no.5
    • /
    • pp.273-276
    • /
    • 2001
  • In order to develop effective acclimatization methods for Aralia elata plantlets regenerated from somatic embryos, various acclimatizing conditions were compared regarding both survival rate and growth of the plantlets. The plantlets were transplanted into plastic boxes containing artificial soil in the presence of either several levels of MS liquid media, distilled water, 2% sucrose or 0.1% hyponex solution. They were then cultured by spraying of distilled water twice a week and maintained in the normal tissue culture room. Perlite was proved to be better than vermiculite on survival rate and growth of the plantlets. As the size of perlite (larger than 0.2 cm in diameter) increased, both the survival rate and growth of the plantlets improved. Among the various MS liquid media and different aqueous solutions tested, distilled water appeared to result in the best survival rate and growth. MS media were also effective in increasing survival rate and supporting growth when diluted to 1/4 and/or 1/8. The acclimatized plantlets could be transplanted directly onto the nursery bed and grown normally. The above results suggest that plantlets regenerated from somatic embryos of Aralia elata be effectively acclimatized using a plastic box containing perlite with distilled water treatment.

  • PDF

Quantitative analysis of 3-MCPD in water using LC-MS (LC-MS를 이용한 수용액중의 3-MCPD 정량)

  • Park, Gyo-Beom;Kim, Yong-Hwa;Kim, Jin-Sung;Jeong, Ja-Young;Kim, Choong-Yong;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.198-203
    • /
    • 2007
  • The analysis method of 3-Monochloropropane-1,2-diol (3-MCPD) compound in water was developed using liquid chromatography with mass spectrometric detection. Aqueous solution was controlled in strong basic condition with sodium hydroxide, and then $25{\mu}L$ of benzoyl chloride was added to the solution for the derivatization of 3-MCPD. The derivative was extracted using pentane and analyzed by the selected ion monitoring (SIM) method of LC-MS. The results of analyses showed that the calibration curves was in the range of 1.0 to $100{\mu}g/mL$ with a good linearity (correlation coefficient of $r^2=0.992$) and limit of detection was below $0.01{\mu}g/mL$. The recoveries of this analysis method by LC-MS were 92.3-98.0 %.

Uncertainty evaluation for the determination of creatinine in urine by LC-MS/MS (LC-MS/MS를 이용한 소변 중 크레아티닌 분석의 측정불확도 평가)

  • Kim, Jin-Young;Kwon, Woon-Yong;Suh, Sung-Ill;In, Moon-Kyo
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.83-90
    • /
    • 2012
  • The objective of the study was to estimate the measurement uncertainty associated with determination of creatinine (Cr) in urine samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Centrifuged urine samples (10 ${\mu}L$) were diluted with 390 ${\mu}L$ of distilled water. To 20 ${\mu}L$ aliquots of diluted urine samples, 30 ${\mu}L$ of internal standard solution (Cr-$d_3$, 5 ${\mu}g/mL$) and 10 ${\mu}L$ of acetonitrile were added and filtered. The samples (1 ${\mu}L$) were introduced into LC-MS/MS with no further pretreatment. Cr was separated on a multi-mode ODS column (Scherzo SM-C18, 75 ${\times}$ 2.0 mm I.D., 3 ${\mu}m$) and quantified by LC-MS/MS operating in MRM mode (Cr, m/z 114.0${\rightarrow}$ 86.0; Cr-$d_3$, m/z 117.0${\rightarrow}$ 89.1). The four factors that contribute uncertainty to the final result were extracted and evaluated. The principal factors of contribution to combined standard uncertainty were sample dilution, calibration curve and repeatability, while the preparation of standard solution was only a minor factor. Relative extended uncertainty of the measured concentration was 14.2% in a real urine sample.

A short study of uncertainty for post column isotope dilution method in HPLC-ICP/MS (HPLC-ICP/MS에서 후 컬럼 동위원소 희석법의 기초적인 불확도 연구)

  • Joo, Mingyu;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.269-276
    • /
    • 2014
  • A short study for the uncertainty of post column isotope dilution method has been performed for the analysis of Selenomethionine in HPLC-ICP/MS. Major error sources studied were concentration and the flow rate of Se isotope solution, atomic weights of Se in spike and sample, and isotope ratio measured for the spiked sample. Uncertainties were obtained for each factor and the contribution for the total concentration uncertainty was 54.4% and 0.61%, 0.0072% and 0.018%, and 45.0%, respectively. The biggest contribution factor was concentration of the spike solution and the second was the isotopic ratio measured for the spiked sample solution. The mass flow rate of spike and atomic weights did not show much contribution. The calculated total uncertainty was $1.46ng{\cdot}g^{-1}$ for the standard SeMet ($126.30ng{\cdot}g^{-1}$). The experimental result was $127.09{\pm}1.46ng{\cdot}g^{-1}$ and the relative uncertainty was 1.20%.