• Title/Summary/Keyword: MRI scan

Search Result 338, Processing Time 0.434 seconds

Treatment of Osteoid Osteoma (유골 골종의 치료)

  • Han, Chung-Soo;Cho, Chang-Hyun;Cho, Young-Lin;Cho, Nam-Su;Lim, Chan-Teak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • Purpose : The purpose of the current study was to report the results of curettage and en bloc excision as well as to introduce how to excise the nidus percutaneously with Halo-mill. Material and Methods : Twenty patients(14 men and 6 women) were evaluated, who had operative treatments after diagnosed as osteoid osteoma from March 1990 to January 1998. These patients ranged in age from 7 to 42 years(average: 20.8 years). Locations were 9 femurs, 6 tibias, 2 vertebras, 1 ulna, 1 maxilla and 1 skull. Nine femoral lesions included 5 proximal metaphysis, 2 neck and 2 diaphysis, while 5 tibial lesions included 3 diaphysis, 1 proximal metaphysis and 1 distal metaphysis. We used simple radiography, bone scan, CT and MRI for the accurate diagnosis and localization. As for surgical treatments, while excision and curettage had to need open-exposure of lesion, the percutaneous excision of nidus did not need openexposure : guided Halo-mill into K-wire inserted to nidus under image intensifier. Results : Simple radiography showed that 10 cases had typical nidus and others had only cortical sclerosis. Bone scan was performed at 14 cases and all had hot uptake except one case. We used CT in 10 cases and MRI in 4 cases as diagnostic methods, of which 1 case didn't reveal nidus at CT. Surgical treatment consisted of 6 curettages, 11 excisions, 2 percutaneous excisions with halo-mill and 1 total elbow arthroplasty. We used 7mm sized Halo-mill. During the follow-up period, all patient relieved symptoms and there were no recurrences. All had histologically typical findings except one which had hyperostosis without nidus. Conclusion : Complete removal of the nidus is the most important factor in the treatment. We could excise the nidus percutaneously in 2 cases with the minimal injury to surrounding soft tissues. If we could evaluate the precise location, size of nidus and percutaneous acccesibility, the percutaneous excision of nidus with Halo-mill could be an alternative method as a treatment of osteoid osteoma.

  • PDF

Smoking-Induced Dopamine Release Studied with $[^{11}C]Raclopride$ PET ($[^{11}C]Raclopride$ PET을 이용한 흡연에 의한 도파민 유리 영상 연구)

  • Kim, Yu-Kyeong;Cho, Sang-Soo;Lee, Do-Hoon;Ryu, Hye-Jung;Lee, Eun-Ju;Ryu, Chang-Hung;Jeong, In-Soon;Hong, Soo-Kyung;Lee, Jae-Sung;Seo, Hong-Gwan;Jeong, Jae-Min;Lee, Won-Woo;Kim, Sang-Eun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.421-429
    • /
    • 2005
  • Purpose: It has been postulated that dopamine release in the striatum underlies the reinforcing properties of nicotine. Substantial evidence in the animal studies demonstrates that nicotine interacts with dopaminergic neuron and regulates the activation of the dopaminergic system. The aim of this study was to visualize the dopamine release by smoking in human brain using PET scan with $[^{11}C]raclopride$. Materials and Methods: Five male non-smokers or ex-smokers with an abstinence period longer than 1 year (mean age of $24.4{\pm}1.7$ years) were enrolled in this study $[^{11}C]raclopride$, a dopamine D2 receptor radioligand, was administrated with bolus-plus-constant infusion. Dynamic PET was performed during 120 minutes ($3{\times}20s,\;2{\times}60s,\;2{\times}120s,\;1{\times}180s\;and\;22{\times}300s$). following the 50 minute-scanning, subjects smoked a cigarette containing 1 mg of nicotine while in the scanner. Blood samples for the measurement of plasma nicotine level were collected at 0, 5, 10, 15, 20, 25, 30, 45, 60, and 90 minute after smoking. Regions for striatal structures were drawn on the coronal summed PET images guided with co-registered MRI. Binding potential, calculated as (striatal-cerebellar)/cerebellar activity, was measured under equilibrium condition at baseline and smoking session. Results: The mean decrease in binding potential of $[^{11}C]raclopride$ between the baseline and smoking in caudate head, anterior putamen and ventral striatum was 4.7%, 4.0% and 7.8%, respectively. This indicated the striatal dopamine release by smoking. Of these, the reduction in binding potential in the ventral striatum was significantly correlated with the cumulated plasma level of the nicotine (Spearman's rho=0.9, p=0.04). Conclusion: These data demonstrate that in vivo imaging with $[^{11}C]raclopride$ PET could measure nicotine-induced dopamine release in the human brain, which has a significant positive correlation with the amount or nicotine administered bt smoking.

[ $^1H$ ] MR Spectroscopy of the Normal Human Brains: Comparison between Signa and Echospeed 1.5 T System (정상 뇌의 수소 자기공명분광 소견: 1.5 T Signa와 Echospeed 자기공명영상기기에서의 비교)

  • Kang Young Hye;Lee Yoon Mi;Park Sun Won;Suh Chang Hae;Lim Myung Kwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.79-85
    • /
    • 2004
  • Purpose : To evaluate the usefulness and reproducibility of $^1H$ MRS in different 1.5 T MR machines with different coils to compare the SNR, scan time and the spectral patterns in different brain regions in normal volunteers. Materials and Methods : Localized $^1H$ MR spectroscopy ($^1H$ MRS) was performed in a total of 10 normal volunteers (age; 20-45 years) with spectral parameters adjusted by the autoprescan routine (PROBE package). In all volunteers, MRS was performed in a three times using conventional MRS (Signa Horizon) with 1 channel coil and upgraded MRS (Echospeed plus with EXCITE) with both 1 channel and 8 channel coil. Using these three different machines and coils, SNRs of the spectra in both phantom and volunteers and (pre)scan time of MRS were compared. Two regions of the human brain (basal ganglia and deep white matter) were examined and relative metabolite ratios (NAA/Cr, Cho/Cr, and mI/Cr ratios) were measured in all volunteers. For all spectra, a STEAM localization sequence with three-pulse CHESS $H_2O$ suppression was used, with the following acquisition parameters: TR=3.0/2.0 sec, TE=30 msec, TM=13.7 msec, SW=2500 Hz, SI=2048 pts, AVG : 64/128, and NEX=2/8 (Signa/Echospeed). Results : The SNR was about over $30\%$ higher in Echospeed machine and time for prescan and scan was almost same in different machines and coils. Reliable spectra were obtained on both MRS systems and there were no significant differences in spectral patterns and relative metabolite ratios in two brain regions (p>0.05). Conclusion : Both conventional and new MRI systems are highly reliable and reproducible for $^1H$ MR spectroscopic examinations in human brains and there are no significant differences in applications for $^1H$ MRS between two different MRI systems.

  • PDF

Treatment of Intracranial Meningioma with Linac Based Radiosurgery (뇌수막종에서 선형가속기를 이용한 방사선수술 효과)

  • Kay Chul Seung;Yoon Sei Chul;Chung Su Mi;Ryu Mi Ryung;Kim Yeon Sil;Suh Tae Suk;Choi Kyuho;Son Byung Chul;Kim Moon Chan
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.81-86
    • /
    • 2001
  • Prupose : To evaluate the role of linac based radiosurgery (RS) in the treatment of meningiomas, we retrospectively analyzed the results of clinical and follow up CT/MRI studies. Methods and Materials : From the 1988 July to 1998 April, twenty patients of meningioma had been treated with 6 MV linear accelerator based radiosurgery. Of the 20 patients, four $(20\%)$ were male and 16 $(80\%)$ were female. Mean age was 51 years old ($22\~78$ years old). Majority of intracranial location of tumor for RS were parasagittal and sphenoid wing area. RS was done for primary treatment in 6 $(30\%)$, postoperative residual lesions in 11 $(55\%)$ and regrowth after surgery in 3 $(15\%)$. Mean tumor volume was $5.72\;cm^3\;(0.78\~15.1\;cm^3)$ and secondary collimator size was 2.04 cm $(1\~3\;cm)$. The periphery of tumor margin was prescribed with the mean dose of 19.6 Gy $(9\~30\;Gy)$ which was $40\~90\%$ of the tumor center dose. The follow up duration ranged from 2.5 to 109 months (median 53 months). Annual CT/MRI scan was checked. Results : By the follow up imaging studies, the tumor volume was reduced in 5 cases $(25\%)$, arrested growth in 14 cases $(70\%)$, and increased size in 1 case $(15\%)$. Among these responsive and stable 19 patients by imaging studies, there showed loss of contrast enhancement after CT/MRI in four patients. In clinical response, nine $(45\%)$ patients were considered improved condition, 10 $(50\%)$ patients were stable and one $(5\%)$ was worsened to be operated. This partly resulted in necrosis after surgery. Conclusion : The overall control rate of meningiomas with linac based RS was $95\%$ by both imaging follow-up and clinical evaluation. With this results, linac based RS is considered safe and effective treatment method for meningioma.

  • PDF

Assessment of the Synovial Inflammation in Rheumatoid Arthritis with $^{99m}Tc$-labelled Polyclonal Human IgG(HIG): Prospective Comparison with Gadolinium Enhanced MRI ($^{99m}Tc$-labelled HIG 스캔을 이용한 류마티스 관절염 환자에서 활막염증의 평가 : 조영증강 자기공명영상과의 전향적인 비교)

  • Ryu, Young-Hoon;Lee, Jong-Doo;Suh, Jin-Suck;Park, Chang-Yun;Jeon, Pyoung;Na, Jae-Beom;Lee, Soo-Kon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.84-91
    • /
    • 1995
  • Many clinical and laboratory tests have been employed to evaluate disease activity in rheumatioid arthritis. $^{99m}Tc$-labelled polyclonal IgG(HIG) has been demonstrated to accumulate in focal sites of infection or inflammation in both animals and human subjects. The purpose of this study was to distinguish arthritis with active inflammation from those without active inflammation and to correlate relative intensities of $^{99m}Tc$-labelled HIG uptake of the rheumatoid arthritis with clinical and MR indices of the joint inflammation. This study included twelve patients with active rheumatoid arthritis, two with ankylosing spondylitis and one with degenerative osteoarthritis without active inflammation. A Whole-body and spot images were obtained 4 hours after intravenous injection of 20mCi of $^{99m}Tc$-labelled HIG. Scintigrams were assessed visually by 3 experienced radiologists, and graded as normal or mildly and markedly increased uptake within the joints, and the degree of uptake was compared with clinical and radiologic severity of synovial inflammation. MRI studies were done on the involved joints consisted of wrist(n = 11), knee(n = 2) and hip joint(n= 2). Active synovitis was defined when marked elevation of ESR and gadolinium enhancement of synovium on MRI were demonstrated. Markedly increased radiotracer uptake was seen in 10 of 11 rheumatoid arthritic patients with active synovitis whereas normal or mildly increased uptakes were noted in others, including rheumatoid arthritic patient(n=1) and non-rheumatoid patients(n = 3) without active synovitis. This study showed that the localization of involved joints in rheumatoid arthritis could be detected with $^{99m}Tc$-labelled HIG and that the degree of uptake correlated well with the degree and activity of inflammation. In conclusion, $^{99m}Tc$-labelled HIG scan is a useful method in the evaluation of active inflammation in rheumatoid arthritis.

  • PDF

BOLD Responses to Acupuncture on Each Side of ST36 (족삼리 좌우측 자침에 대한 BOLD 반응)

  • Yeo, Sujung;Bae, Seong-In;Choe, Ilwhan;Jahng, Geon-Ho;Lim, Sabina
    • Korean Journal of Acupuncture
    • /
    • v.31 no.1
    • /
    • pp.20-32
    • /
    • 2014
  • Objectives : There has been some controversy about the modulatory effects on brain function during acupuncture on each side of the same acupoint. This study was designed to investigate and compare the blood oxygen level-dependent(BOLD) responses of acupuncture on each side of ST36. Methods : Fourteen healthy subjects were recruited for imaging and received acupuncture or placebo stimulations either on the left or on the right acupoint of ST36 in each scan. For the voxel-wise statistical analysis, one sample T-test and the within-subject analysis of variance(ANOVA) test were performed using SPM8 software. Results : This study showed that acupuncture on each side of ST36 showed different BOLD signal patterns. Higher BOLD responses after acupuncture stimulations at the left ST36 compared to the right were observed mainly in the parahippocampal gyrus(BA 28), dorsolateral prefrontal cortex(DLPFC, BA 44), thalamus, culmen and claustrum. We investigated the different neural responses between rest and activation periods of placebo and acupuncture stimulations on each side of ST36. Acupuncture at the right ST36 elicited activation mainly in the insula, supplementary motor area(SMA) and anterior cingulate cortex(ACC), while acupuncture at the left ST36 elicited activation mainly in the insula, primary somatosensory cortex(SI, BA 2) and DLPFC(BA 44). Conclusions : To our knowledge, this is the first reported functional MRI study directly comparing when needling at the right and at the left side of ST36. This study's preliminary results proved to be evidence of acupuncture's different effects when performed on opposite sides of an acupoint.

Time Resolution Improvement of MRI Temperature Monitoring Using Keyhole Method (Keyhole 방법을 이용한 MR 온도감시영상의 시간해상도 향상기법)

  • Han, Yong-Hee;Kim, Tae-Hyung;Chun, Song-I;Kim, Dong-Hyeuk;Lee, Kwang-Sig;Eun, Choong-Ki;Jun, Jae-Ryang;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.31-39
    • /
    • 2009
  • Purpose : This study proposes the keyhole method in order to improve the time resolution of the proton resonance frequency(PRF) MR temperature monitoring technique. The values of Root Mean Square (RMS) error of measured temperature value and Signal-to-Noise Ratio(SNR) obtained from the keyhole and full phase encoded temperature images were compared. Materials and Methods : The PRF method combined with GRE sequence was used to get MR temperature images using a clinical 1.5T MR scanner. It was conducted on the tissue-mimic 2% agarose gel phantom and swine's hock tissue. A MR compatible coaxial slot antenna driven by microwave power generator at 2.45GHz was used to heat the object in the magnetic bore for 5 minutes followed by a sequential acquisition of MR raw data during 10 minutes of cooling period. The acquired raw data were transferred to PC after then the keyhole images were reconstructed by taking the central part of K-space data with 128, 64, 32 and 16 phase encoding lines while the remaining peripheral parts were taken from the 1st reference raw data. The RMS errors were compared with the 256 full encoded self-reference temperature image while the SNR values were compared with the zero filling images. Results : As phase encoding number at the center part on the keyhole temperature images decreased to 128, 64, 32 and 16, the RMS errors of the measured temperature increased to 0.538, 0.712, 0.768 and 0.845$^{\circ}C$, meanwhile SNR values were maintained as the phase encoding number of keyhole part is reduced. Conclusion : This study shows that the keyhole technique is successfully applied to temperature monitoring procedure to increases the temporal resolution by standardizing the matrix size, thus maintained the SNR values. In future, it is expected to implement the MR real time thermal imaging using keyhole method which is able to reduce the scan time with minimal thermal variations.

  • PDF

Measurement of the Grafts for the Anterior Cruciate Ligament Reconstruction with Tension Load Technique and Achilles Tendon Autograft using Postoperative Magnetic Resonance Imaging (자가 아킬레스 건과 장력 부하 기법을 이용한 전방십자인대 재건술 후 자기 공명 영상을 이용한 이식건의 평가)

  • Seo, Jai-Gon;Moon, Young-Wan;Yoo, Jae-Chul;Chang, Moon-Jong;Kim, Seung-Yeon;Kim, Mu-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.191-197
    • /
    • 2008
  • Purpose: To evaluate the postoperative magnetic resonance image (MRI) findings of anterior cruciate ligament (ACL) reconstructed with a tension load technique using auto-Achilles tendon, and to compare the results with knees with a native ACL. Materials and Methods: We evaluated 21 postoperative MRI scan of 21 patients (group A) who had undergone ACL reconstruction between January 1995 and November 1996. The control group (group B) consisted of 50 patients whose meniscus tear had been operated by arthroscopy and whose ACL was intact. We measured the orientation of the graft in the sagittal and coronal planes and compared it with that of the native ACL. Results: The mean sagittal angle of the ACL angle in group A ($55.7{\pm}5.6^{\circ}$, range $47.2{\sim}68.8^{\circ}$) was statistically lesser than group B ($58.7{\pm}3.8^{\circ}$, range $50.4{\sim}67.5^{\circ}$) (p=0.036). But there was no statistically significant difference between the two groups with regard to the mean ACL-Blumensaat line angle (group A: $8.1^{\circ}{\pm}4.9^{\circ}$, range $1.7^{\circ}{\sim}22.0^{\circ}$, group B: $8.6^{\circ}{\pm}3.6^{\circ}$, range $2.6^{\circ}-18.1^{\circ}$) and the mean coronal angle of the ACL (group A: $64.9^{\circ}{\pm}9.1^{\circ}$, range $46.9^{\circ}{\sim}76.4^{\circ}$, group B: $65.9^{\circ}{\pm}4.4^{\circ}$, range $57.7^{\circ}{\sim}75.2^{\circ}$)(p=0.88, p= 0.62). In the sagittal plane, the mean center of tibial insertion of the ACL graft in group A ($31.9{\pm}7.1%$, range 22.4-47.9%) was positioned more anteriorly than group B ($37.0{\pm}4.9%$, range $18.5{\sim}44.7%$)(p=0.005). But in the coronal plane, there was no statistically significant difference between the two groups(group A: $46.3{\pm}2.8%$, range $42.1{\sim}52.5%$, group B: $45.7{\pm}2.8%$, range $41.0{\sim}49.1%$)(p=0.392). Conclusion: We performed an ACL reconstruction with the tension load technique using auto-Achilles tendon and we found that the graft orientation in MRI was as good as that of the native ACL.

  • PDF

Understanding on MR Perfusion Imaging Using First Pass Technique in Moyamoya Diseases (Moyamoya 질환에서 1차 통과기법을 이용한 자기공명관류영상의 이해)

  • Ryu, Young-Hwan;Goo, Eun-Hoe;Jung, Jae-Eun;Dong, Kyung-Rae;Choi, Sung-Hyun;Lee, Jae-Seung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.27-31
    • /
    • 2010
  • The purpose of this study was to investigated the usefulness of MR perfusion image comparing with SPECT image. A total of pediatric 30 patients(average age : 7.8) with Moyamoya disease were performed MR Perfusion with 32 channel body coil at 3T from March 01, 2010 to June 10, 2010. The MRI sequences and parameters were as followed : gradient Echo-planar imaging(EPI), TR/TE : 2000ms/50ms, FA : $90^{\circ}$, FOV : $240{\times}240$, Matrix : $128{\times}128$, Thickness : 5mm, Gap : 1.5mm. Images were obtained contrast agent administrated at a rate of 1mL/sec after scan start 10s with a total of slice 1000 images(50 phase/1 slice). It was measured with visual color image and digitize data using MRDx software(IDL version 6.2) and also, it was compared of measurement with values of normal and abnormal ratio to analyze hemodynamic change, and a comparison between perfusion MR with technique using Warm Color at SPECT examination. On MR perfusion examination, the color images from abnormal region to the red collar with rCBV(relative cerebral blood volume) and rCBF(relative cerebral blood flow) caused by increase cerebral blood flow with brain vascular occlusion in surrounding collateral circulation advancement, the blood speed relatively was depicted slowly with blue in MTT(Mean Transit Time) and TTP(Time to Peak) images. The region which was visible abnormally from MR perfusion examination visually were detected as comparison with the same SPECT examination region, would be able to confirm the identical results in MMD(Moyamoya disease)judgments. Hymo-dynamic change in MR perfusion examination produced by increase and delay cerebral blood flow. This change with digitize data and being color imaging makes enable to distinguish between normal and abnormal area. Relatively, MR perfusion examination compared with SPECT examination could bring an excellent image with spatial resolution without radiation expose.

  • PDF

Primary Non-Hodgkin's Lymphoma in Right Ventricle with Right Atrial Invasion -Report of 1 case- (우심실에 발생하여 우심방을 침범한 원발성 비호지킨씨 림프종 -1예 보고-)

  • Park, Ki-Sung;Ahn, Wook-Su;Lee, Sub;Kwon, Oh-Choon;Ko, Moo-Sung;Jheon, Sang-Hoon
    • Journal of Chest Surgery
    • /
    • v.37 no.4
    • /
    • pp.376-381
    • /
    • 2004
  • Primary cardiac lymphoma is an extranodal malignant lymphoma of any cell type involving only heart and pericardium without dissemination. Patients usually present symptoms of heart failure, arrhythmias, pericardial effusion and cardiac tamponade. Diagnosis of primary cardiac lymphoma can be performed by echocardiogram, CT and MRI and cytologic examination of pericardial effusion or transvenously biopsied cardiac tissue. Prognosis of primary cardiac lymphoma is poor. Because of poor prognosis, early diagnosis and complete surgical excision is essential and postoperative systemic chemotherapy or radiotherapy is useful. In this case extensive tumor infiltration on the right ventricle and atrioventricular groove preclude surgical excision. Tissue biopsy revealed primary cardiac lymphoma. After postoperative chemotherapy and radiotherapy, the size of intracardiac mass is decreased in follow up chest CT scan and echocardiogram and symptoms of patient are relieved. Therefore, we report a case of primary cardiac lymphoma with review of literatures.