• Title/Summary/Keyword: MRI contrast agent

Search Result 79, Processing Time 0.029 seconds

The Utility Evaluation of Reconstructed 3-D Images by Maximum Intensity Projection in Magnetic Resonance Mammography and Cholangiopancreatography

  • Cho, Jae-Hwan;Lee, Hae-Kag;Park, Cheol-Soo;Kim, Ham-Gyum;Baek, Jong-Geun;Kim, Eng-Chan
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.365-371
    • /
    • 2014
  • The aim of this study was to evaluate the utility of 3-D images by comparing and analyzing reconstructed 3-D images from fast spin echo images of MRI cholangiopancreatography (MRCP) images using maximum intensity projection (MIP) with the subtraction images derived from dynamic tests of magnetic resonance mammography. The study targeted 20 patients histologically diagnosed with pancreaticobiliary duct disease and 20 patients showing pancreaticobiliary duct diseases, where dynamic breast MR (magnetic resonance) images, fast spin echo imaged of pancreaticobiliary duct, and 3-D reconstitution images using a 1.5T MR scanner and 3.0T MR scanner were taken. As a result of the study, the signal-to-noise ratio in the subtracted breast image before and after administering the contrast agent and in the reconstructed 3-D breast image showed a high ratio in the reconstructed image of lesional tissue, relevant tissue, and fat tissue. However, no statistically meaningful differences were found in the contrast-to-noise ratio of the two images. In the case of the MRCP image, no differences were found in the ratios of the fast spin echo image and reconstructed 3-D image.

The increase of blood vessels using a signal during the image acquisition phase T1 shortening effect (위상영상 획득 시 T1 shortening effect를 이용한 혈관의 신호 증가에 관한 연구)

  • Lee, Ho-Beom;Choi, Kwan-Woo;Son, Soon-Yong;Min, Jung-Whan;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4704-4710
    • /
    • 2015
  • The purpose of this study is to obtain a useful diagnostic image by increasing the signal strength of the peripheral artery, was to use a T1 shortening effect of gadolinium contrast agents to improve the disadvantages of the phase image. From october to december 2014 thirty patients were underwent the MRI scanning, except for heart disease. Research method was evaluated comparing the image after gadolinium contrast MR image acquisition step before evaluating the difference between the signal intensity for T1 shortening effect. In frontal lobe 19.45%, temporal lobe 23.09%, occipital lobe 25.45%, parietal lobe 18.82%, cerebellum 20.93% after peripheral arterial signal strength results of gadolinium contrast agent injection was increased significantly after injection of gadolinium both statistically significant. After injecting a contrast agent gadolinium in SWI by increasing the signal strength of the T1 shortening effect can be obtained when using the phase image to give a useful image in diagnosis and treatment.

The Synthesis and MR Properties of New Macromolecular MR Contrast Agent (새로운 거대분자 MR 조영제의 합성 및 MR 특성에 관한 연구)

  • 장용민;장영환;황문정;박현정;전경녀;이종민;배경수;강봉석
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.35-40
    • /
    • 2002
  • Purpose : To evaluate the NMR relaxation properties and imaging characteristics of tissue-specificity for a newly developed macromolecular MR agent. Materials and methods : Phthalocyanine (PC) was chelated with paramagnetic ion, Mn.2.01g (5.2 mmol) of Phthalocyanine was mixed with 0.37g (1.4 mmol) of Mn chloride at $310^{\circ}C$ for 36 hours and then purified by chromatography (CHC13/CH3OH 98/2 v/v, Rf, 0.76) to obtain 1.04g (46%) of MnPC (molecular weight= 2000d). The $T1}T2$ relaxivity of MnPC was measured in 1.5T(64 MHz) MR using 0.1 mM MnPC. The MR image characteristics of MnPC was evaluated using spin-echo (TR/TE=500/14 msec) and gradient-echo (FLASH) (TR/TE=80/4 msec, flip angle=60) techniques in 1.57 MR scanner. The images of rabbit liver were obtained every 10 minutes up to 4 hours. To study the effect of concentration on image, 20 mM, 50 mM, 100 mM of MnPC were tested. Results : The relaxivities of MnPC at 1.5T(64MHz) were Rl=7.28 $mM^{-1}S^{-1},{\;}R2=55.56mM^{-1}S^{-1}$. Compared to the values of Gd-DTPA (Rl[=4.8 $mM^{-1}S^{-1})$], R2[=5.2 $mM^{-1}S^{-1}])$]), both T1/T2 relaxivities of MnPC were higher than those of Gd-DTPA. For both of SE and FLASH techniques, the contrast enhancement reached maximum at 10 minutes after bolus injection and the enhancement continued for more than 2 hours. When compared with small molecular weight liver agents such as Gd-EOB-DTPA, Gd-BOPTA and MnDPDP, MnPC was characterized by more prolonged enhancement time. The time course of MR images also revealed biliary excretion of MnPC. Conclusion : We developed a new macromolecular MR agent, MnPC. The relaxivities of MnPC were higher than those of small molecular weight Gd-chelate. Hepatic uptake and biliary excretion of MnPC suggests that this agent is a new liver-specific MR agent.

  • PDF

Primary Hepatic Lymphoma: MR Imaging and Pathologic Correlation (일차성 간림프종: 자기공명영상과 병리소견의 연관)

  • Kim, Han-Na;Shin, Yu-Ri;Rha, Sung-Eun;Jung, Eun-Sun;Oh, Soon-Nam;Choi, Joon-Il;Jung, Seung-Eun;Lee, Young-Joon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.2
    • /
    • pp.151-155
    • /
    • 2010
  • Primary hepatic lymphoma is extremely rare, representing less than 1% of all extranodal lymphomas. We report MR imaging features and pathologic correlation of a case of primary hepatic lymphoma. MR images showed a large lobulated mass with gradual contrast enhancement, resembling intrahepatic cholangiocarcinoma. However, both hepatobiliary phase image obtained 20 minutes after injection of hepatocyte specific contrast agent and diffusion-weighted image demonstrated characteristic three layered pattern representing viable lymphoma in the outer layer, tumor necrosis in the middle layer and necrotic hepatic parenchyma in the center.

Synthesis and Magnetic Relaxation Properties of Paramagnetic Gd-complexes of New DTPA-bis-amides. The X-ray Crystal Structure of [Gd(L)(H2O)]·3H2O (L = DTPA-bis(4-carboxylicphenyl)amide)

  • Dutta, Sujit;Kim, Suk-Kyung;Lee, Eun-Jung;Kim, Tae-Jeong;Kang, Duk-Sik;Chang, Yong-min;Kang, Sang-Ook;Han, Won-Sik
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.7
    • /
    • pp.1038-1042
    • /
    • 2006
  • A new type of DTPA-bis-amides (L1-L4) and their Gd(III)-complexes of the type $[Gd(L)(H_2O)]{\cdot}nH_2O$ (5: L1; 6: L2; 7: L3; 8: L4) have been prepared and characterized by analytical and spectroscopic techniques. The X-ray crystal structure of 8 has been determined for structural confirmation. The coordination geometry adopts a tricapped trigonal prism geometry with L4 acting as a chelate octadentate and a water molecule in the coordination sphere. Crystals are monoclinic, $P2_1$, a = 14.468(3), b = 19.235(4), c = 13.527(2) $\AA$ $\beta$ = $107.245(3)^{\circ}$, V = 3595.2(11) $\AA^3$, Z = 4, $D_{calc}$ = 1.570. Significant increases in relaxivities are observed with 6 and 7 as compared with that of $Omniscan^{(R)}$, a commercial MR agent: R1 = 12.46 $mM^{-1}\;s^{-1}$, R2 = 8.76 $mM^{-1}\;s^{-1}$ for 6; R1 = 12.77 nm-1 s-1, R2 = 7.60 mM-1 s-1 for 7; R1 = 4.9 $mM^{-1}\;s^{-1}$, R2 = 4.8 $mm^{-1}\;s^{-1}$ for $Omniscan^{(R)}$. In the case of 5, however, both R1 and R2 are found to be lower to show 2.09 $mM^{-1}\;s^{-1}$, and 1.82 $mM^{-1}\;s^{-1}$, respectively.

Combined MRI and Relaxogram: A New Method of Fat Study (MRI와 Relaxogram을 이용한 지질 연구의 새로운 기법에 관한 연구)

  • Yongmin Chang;Yoo, Done-Sik;Kim, Tae-Hun;Kim, Yong-Joo;Kang, Duk-Sik;Robert B. Clarkson
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.23-32
    • /
    • 1999
  • Combined MRI and Relaxogram approach was introduced as a very useful tool for fat study. The phantoms simulating homogeneous mixture of fat and non-fat environments were measured with spin echo pulse sequence on a 0.15 T whole body imager. From 45 scans, the Tl values were obtained by fitting the data to continuous distribution (CONTIN) of relaxation time. This relaxogram gives broad distributions of relaxation time, which are characterized by a number of peaks with characteristic T1 values. Two distinct peaks in relaxogram were observed and identified as signals from com oil and gelatin gel. This model system can be served as simulating the distribution of fat in muscle. Also the relative ratio of two components, which is proportional to the area under the peak, is estimated and compared to nominal values. Based on the good agreement between two predictions, the values from our proposed method agreed with nominal values within $\pm$7 % error. The effects of different concentration of contrast agent and different region of interest are presented. To optimize total scan times, the minimum required data points and so further reduction in total scan times are discussed.

  • PDF

Synthesis of Homing Peptide-Immobilized Magnetite Nanoparticles through PEG Spacer and Their Biomedical Applications (PEG 스페이서를 통해 Homing 펩타이드를 고정화한 산화철 나노입자의 제조 및 생의학적 응용)

  • Lee, Sang-Min;Xing, Zhi-Cai;Shin, Yong-Suk;Gu, Tae-Hyung;Lee, Byung-Heon;Huh, Man-Woo;Kang, Inn-Kyu
    • Polymer(Korea)
    • /
    • v.36 no.5
    • /
    • pp.586-592
    • /
    • 2012
  • Iron oxides ($Fe_3O_4$) are metabolically secreted after endocytosed by cells, indicating no cytotoxicity. Therefore, they are widely used as a contrast agent before photographing of magnetic resonance imaging. In this study, iron oxide nanoparticles are synthesized by the co-precipitation method and subsequently immobilized with a homing peptide (AP), which specifically interacts with interleukin-4 receptor located on the membrane of endothelial and bladder cancer cells. The size of AP-immobilized iron oxide particle is about 39 nm. Intracellular uptake of the AP-immobilized iron oxide nanoparticles was investigated using bladder cancer cells and fibroblasts as the control. As the result, the nanoparticles are specificially uptaken by bladder cancer cells. However, the nanoparticles are not specificially uptaken by fibroblast. It could be said that the AP-immobilized iron oxide nanoparticles have a potential to be used as a contrast agent for early diagnosis of cancer.

Assessments of Dissolved Rare Earth Elements and Anthropogenic Gadolinium Concentrations in Different Processes of Wastewater Treatment Plant in Busan, Korea (부산 하수처리장에서 공정별 용존 희토류 원소의 농도 및 인위적 기원 가돌리늄의 배출량 평가)

  • Lim, Ijin;Ryu, Jong-Sik;Lee, Joonyeob;Lee, Jun-Ho;Cho, Hyung-Mi;Kim, Taejin
    • Journal of the Korean earth science society
    • /
    • v.43 no.2
    • /
    • pp.303-311
    • /
    • 2022
  • Gadolinium, commonly used as a contrast agent for magnetic resonance imaging (MRI), is discharged into aquatic environments without removal after treatment in wastewater treatment plants (WWTPs) because of its high stability. In this study, we collected water samples from Suyeong WWTP, Busan, to investigate the dissolved rare earth element (REE) removal capacity of each wastewater treatment process and to evaluate the discharge of anthropogenic Gd (Gdanth) from effluents. As wastewater passed through each stage of treatment, the concentrations of light REEs (La-Eu) decreased, whereas those of heavy REEs (Tb-Lu) were relatively consistent. Negative Sm anomalies (<1) were observed in several samples, indicating that Sm can be removed by adsorption onto particles or phosphate during the biological removal process. Positive Gd anomalies (149±50, n=9) were observed in all samples. The ratios of Gdanth concentrations to measured Gd concentrations in all wastewater treatment processes were higher than 97%. This indicates that Gdanth was discharged to the Suyeong River without removal during the wastewater treatment process. Considering the daily treatment capacity in each process, the total flux of Gdanth was estimated to be 259 mmol/day. Our results suggest that mid- and/or long-term monitoring of Gd is needed because Gdanth is continuously discharged into Suyeong Bay through WWTPs.

Understanding on MR Perfusion Imaging Using First Pass Technique in Moyamoya Diseases (Moyamoya 질환에서 1차 통과기법을 이용한 자기공명관류영상의 이해)

  • Ryu, Young-Hwan;Goo, Eun-Hoe;Jung, Jae-Eun;Dong, Kyung-Rae;Choi, Sung-Hyun;Lee, Jae-Seung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.27-31
    • /
    • 2010
  • The purpose of this study was to investigated the usefulness of MR perfusion image comparing with SPECT image. A total of pediatric 30 patients(average age : 7.8) with Moyamoya disease were performed MR Perfusion with 32 channel body coil at 3T from March 01, 2010 to June 10, 2010. The MRI sequences and parameters were as followed : gradient Echo-planar imaging(EPI), TR/TE : 2000ms/50ms, FA : $90^{\circ}$, FOV : $240{\times}240$, Matrix : $128{\times}128$, Thickness : 5mm, Gap : 1.5mm. Images were obtained contrast agent administrated at a rate of 1mL/sec after scan start 10s with a total of slice 1000 images(50 phase/1 slice). It was measured with visual color image and digitize data using MRDx software(IDL version 6.2) and also, it was compared of measurement with values of normal and abnormal ratio to analyze hemodynamic change, and a comparison between perfusion MR with technique using Warm Color at SPECT examination. On MR perfusion examination, the color images from abnormal region to the red collar with rCBV(relative cerebral blood volume) and rCBF(relative cerebral blood flow) caused by increase cerebral blood flow with brain vascular occlusion in surrounding collateral circulation advancement, the blood speed relatively was depicted slowly with blue in MTT(Mean Transit Time) and TTP(Time to Peak) images. The region which was visible abnormally from MR perfusion examination visually were detected as comparison with the same SPECT examination region, would be able to confirm the identical results in MMD(Moyamoya disease)judgments. Hymo-dynamic change in MR perfusion examination produced by increase and delay cerebral blood flow. This change with digitize data and being color imaging makes enable to distinguish between normal and abnormal area. Relatively, MR perfusion examination compared with SPECT examination could bring an excellent image with spatial resolution without radiation expose.

  • PDF