• Title/Summary/Keyword: MRI 영상

Search Result 1,880, Processing Time 0.031 seconds

The Role of Functional Imaging Techniques in the Dementia (치매 환자에서 기능 영상법의 역할)

  • Ryu, Young-Hoon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.209-217
    • /
    • 2004
  • Evaluation of dementia in patients with early symptoms of cognitive decline is clinically challenging, but the need for early, accurate diagnosis has become more crucial, since several medication for the treatment of mild to moderate Alzheimer' disease are available. Many neurodegenerative diseases produce significant brain function alteration even when structural imaging (CT or MRI) reveal no specific abnormalities. The role of PET and SPECT brain imaging in the initial assessment and differential diagnosis of dementia is beginning to evolve vapidly and growing evidence indicates that appropriate incorporation of PET into the clinical work up can improve diagnostic and prognostic accuracy with respect to Alzheimer's disease, the most common cause of dementia in the geriatric population. in the fast few years, studios comparing neuropathologic examination with PET have established reliable and consistent accuracy for diagnostic evaluations using PET - accuracies substantially exceeding those of comparable studies of diagnostic value of SPECT or of both modalities assessed side by side, or of clinical evaluations done without nuclear imaging. This review deals the role of functional brain imaging techniques in the evaluation of dementias and the role of nuclear neuroimaging in the early detection and diagnosis of Alzheimer's disease.

Analysis of the Bird-cage Receiver Coil of a MRI System Employing a Equivalent Circuit Model Based on a Transmission Matrix (전송행렬 기반 등가 회로 모델을 이용한 자기공명영상 장치용 새장형 수신 코일 해석)

  • Kim, Hyun Deok
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.7
    • /
    • pp.1024-1029
    • /
    • 2017
  • A novel analytic solution has been derived for the bird-cage receiver coil of a magnetic resonance imaging (MRI) system, which is widely used in 3-dimensional medical imaging, by transforming the coil into an equivalent circuit model by using a transmission matrix-based circuit analysis. The bird-cage coil composed of N legs is divided into a cell for which input impedance is to be analyzed and the remaining N-1 cells, and then a transmission matrix corresponding to the N-1 cells is converted into a circuit to transform the 3-dimensional bird-cage coil into the 2-dimensional equivalent circuit model, which is suitable to derive the analytic solution for the input impedance. The proposed method derives directly the analytic solution for the input impedance at an arbitrary point of the coil unlike the conventional analytic solution of a bird-cage coil, so that it can be used not only for resonance frequency calculations but also for various coil characteristics analyses. Since the analytic solution agreed well with the results of computational simulations, it can be useful for the impedance matching of a coil and the analysis and the design of a multi-tune bird-cage coil.

Magnetic resonance images of ameloblastoma

  • Kim Jae-Duk;Kim Jin-Soo
    • Imaging Science in Dentistry
    • /
    • v.35 no.4
    • /
    • pp.207-213
    • /
    • 2005
  • Purpose: To classify and describe the characteristic features of MRI of some ameloblastoma variants. Materials and Methods: The MR images, CT images, and panoramic radiographs in 5 cases were retrospectively examined as follows. First, the contents of ameloblastomas were devided into two portions of either solid or cystic components on the basis of MR signal intensities. The signal intensity within the solid or cystic portions was classified as homogeneous or heterogeneous. Next, the characteristic internal feature of the lesion on T1W1 or T2WI was described. The signal intensities were classified into low, intermediate, slightly high, high, and strong high signal intensity. Results: Unicystic lesion showed homogeneous high signal intensity (SI) on T2W2 and the rim enhancement of the surrounding area including the mural nodule and the thick wall except the central portion on Gd- T1W1. Solid type revealed heterogeneous and high SI area with strong high SI area on T2W2. On Gd- T1W1, the area corresponding to the low signal spot on T1W1 and the strong high signal spot on T2W1 showed low SI. Hybrid type showed slightly enhanced capsular structures and low SI for the round bony septa and the areas connecting the mixed and cystic lesions on T2Wl and Gd-T1W1. Conclusion: MRI could easily assess the relationship between the mixed and cystic findings in ameloblastoma.

  • PDF

Adrenal Mass as Initial Presentation of Metastatic Hepatocellular Carcinoma: A Case Report (부신의 종괴로 처음 발현한 전이성 간세포암: 증례보고)

  • Kim, Hwan Yong;Park, Chul Hi;Kim, Min Ji;Kim, Yeo-Eun;Lee, Dong Hoon;Hwang, Ho Kyung;Shin, Dong Gue
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.321-325
    • /
    • 2013
  • Metastases from hepatocellular carcinoma (HCC) can be found in the multiple organs including adrenal gland. But adrenal metastasis of HCC without obvious hepatic lesion is very rare. We report CT and MR findings of a patient who presented with adrenal metastasis as the first clinical manifestation of HCC. Signal intensity and enhancement pattern of adrenal metastastic mass of HCC were similar to those of HCC on MRI.

A Ganglion Cyst around the Tarsal Tunnel Detected by Ultrasonography and MRI -A case report- (초음파와 자기공명영상으로 발견된 족근관 주위 결절성 낭종 -증례보고-)

  • Park, Soo Young;Nahm, Francis Sahngun;An, Sang Bum;Kim, Yong Chul;Lee, Sang Chul
    • The Korean Journal of Pain
    • /
    • v.22 no.1
    • /
    • pp.65-67
    • /
    • 2009
  • Tarsal tunnel syndrome is often misdiagnosed it shares clinical features with other diseases of the lower extremity such as lumbar radiculopathy and arthritis. Failure to diagnose and treat neuropathies effectively can cause permanent neuropathic pain. We report a case of a ganglion cyst detected early using ultrasonography and MRI in a 51-year-old man who complained of rapidly aggravating pain, numbness and paresthesia on the great toe and the first metatarsal area in the sole, symptoms that resembled tarsal tunnel syndrome. Surgical treatment could be performed early with no permanent sequelae. We could also avoid repeated steroid injections or prescription medications.

Scan Time Analysis Using 4D Phase-Contrast MRI According to Scan Parameter: A Phantom Study (스캔 인자에 따른 4D 위상 대조 자기공명영상을 이용한 스캔 시간 분석: 팬텀 연구)

  • Park, Jieun;Kim, Junghun;Hwang, Moonjung;Lee, Jongmin
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.179-184
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the effect according to the NEX, VENC, targeted cardiac phases on the velocity measurement of 4D phase-contrast MRI. Materials and Methods: The abdominal aortic phantom was made to experiment. The working fluid was mixed with water and glycerin to mimic the density and viscosity of human blood. The inlet velocity was Reynolds number 2000. The experimental conditions were NEX 1 and 4, VENC 102 cm/s and 200 cm/s, and 10 and 15 targeted cardiac phases, respectively. The average flow rate, average velocity, maximum velocity, and cross-section area were measured. Results: As a result of the case-by-case comparison, the error rate was less than 5%. There was no significant difference (p > 0.05). Conclusion: It is expected that this result will be useful for acquiring blood flow information in clinical practice.

Magnetic Resonance Imaging Follow-Up Case Study on Changes in a Lumbar Herniated Intervertebral Disc Treated with Korean Conservative Treatment (보존적 한방치료를 진행한 요추 추간판 탈출증 환자의 시간에 따른 영상의학적 추간판 크기 변화 1례)

  • Roh, Ji-ae;Lee, Ji-won;Jang, Jae-won;Jeong, Wu-jin;Noh, Je-heon
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.5
    • /
    • pp.879-885
    • /
    • 2018
  • Background: A herniated intervertebral disc (HIVD) triggers low back pain (LBP). Korean conservative treatment can decrease the herniated disc size without traditional surgery, but detailed prognosis is unclear. Case summary: One patient presented with LBP and bilateral sciatica. She was diagnosed with lumbar HIVD by magnetic resonance imaging (MRI) and treated by Korean medicine (acupuncture, decoction, and physical therapy). For 6 months, MRI follow-up exams showed the aggravation and migration of L5-S1 followed by distinct improvement of the same lumbar vertebra. Conclusion: The disc size in a patient with lumbar HIVD was reduced by Korean conservative treatment, and periodic radiologic examination showed the previously unrecognized process of absorbing the disc.

Painful Causes around Hip Joint and Evaluation using Ultrasonography (고관절 주위 통증의 원인과 초음파적 진단)

  • Han, Kye Young
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.1
    • /
    • pp.45-52
    • /
    • 2009
  • Simple radiography, CT and MRI were used for the diagnosis of the hip disease. However ultrasonography could be a good diagnostic tool for the lesion of tendons and bursae. Another advantage of ultrasonography is its usefulness for the follow-up of these lesions. Nowadays hip ultrasonography expanded the horizon to the follow-up study of total hip arthroplasty. However, the limitation of ultrasonography is that there is disparity in results according to the physician's experiences. In this article ultrasonographic findings of normal structures and pathologic lesions of the hip joint are introduced and explained briefly.

  • PDF

An Open Bridcage RF coil for Magnetic Rresonance Imaging (자기공명영상을 위한 개방형 새장 고주파코일)

  • Lee, S.Y.;Yi, J.H.;Yi, W.;Mun, C.W.;Cho, M.H.
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.5
    • /
    • pp.42-47
    • /
    • 1998
  • Bridcage RF coil is one of the most widely used RF coils in MRI. In order to use birdcage RF coils in open MRI systems, an open tructured birdcage RF coil has been investigated. By opening the ring structure of an original birdcage RF coil and driving the coil at two opening ends, the original birdcage RF coil can be modified to an open structured coil. In order to improve magnetic field uniformity of the open birdcage RF coil, driving voltage phases at the two opening ends can be controlled to be in-phase or out-of-phase each other. Operating frequency of the open birdcage RF coil has been theoretically derived, and the theoretical derivation has been verified by experiments.

  • PDF

A Study on the Performance Improvement for Magnetic Resonance Imaging Examination by Using the 6-Sigma Application (6-시그마 기법을 이용한 자기공명영상 검사 실적 개선에 대한 연구)

  • Seoung, Youl-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.243-249
    • /
    • 2011
  • The purpose of the study was to improve of performance for Magnetic Resonance Imaging (MRI) examination in the department of radiology. It was performed DMAIC (Define, Measure, Analyze, Improve, and Control). In the stage of definition, The fifth kinds of CTQ (critical to quality) by the kindness, the waiting time, the examination explanation, the waiting time and the waiting environment were selected by voice of customer. In the stage of measurement, the performed examinations and the reservation waiting time were measured each 1.77 and 1.69 sigma. In the stage of analysis, the potential key causes were determined the limited working hours and the difference of examination time of various entries. In the stage of improvement, MRI were performed with the operating system of 24 hours examination and the optimization of the difference of examination time by among of 30 minutes, 40 minutes, 50 minutes. Finally, the number of examinations and reserved waiting days were measured by each 3.17 and 1.71 sigma in the control stage.