• Title/Summary/Keyword: MRI 모델

Search Result 126, Processing Time 0.032 seconds

Detection and Forecast of Climate Change Signal over the Korean Peninsula (한반도 기후변화시그널 탐지 및 예측)

  • Sohn, Keon-Tae;Lee, Eun-Hye;Lee, Jeong-Hyeong
    • The Korean Journal of Applied Statistics
    • /
    • v.21 no.4
    • /
    • pp.705-716
    • /
    • 2008
  • The objectives of this study are the detection and forecast of climate change signal in the annual mean of surface temperature data, which are generated by MRI/JMA CGCM over the Korean Peninsula. MRI/JMA CGCM outputs consist of control run data(experiment with no change of $CO_2$ concentration) and scenario run data($CO_2$ 1%/year increase experiment to quadrupling) during 142 years for surface temperature and precipitation. And ECMWF reanalysis data during 43 years are used as observations. All data have the same spatial structure which consists of 42 grid points. Two statistical models, the Bayesian fingerprint method and the regression model with autoregressive error(AUTOREG model), are separately applied to detect the climate change signal. The forecasts up to 2100 are generated by the estimated AUTOREG model only for detected grid points.

Sacroiliac Joint MRI Segmentation to Generate RoI of Ilium (장골의 관심영역 생성을 위한 천장관절 MRI 세그멘테이션)

  • Lee, Go-Eun;Min, Jae-Eun;Choi, Changhwan;Cho, Jungchan;Choi, Sang Tae;Choi, Sang-Il
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2022.07a
    • /
    • pp.223-224
    • /
    • 2022
  • 본 논문에서는 축형 척추관절염으로 발전할 수 있는 천장관절염 환자들을 진단하기 위해 장골의 관심영역을 자동 생성할 수 있는 세그멘테이션 방법을 제안한다. 다양한 MRI 기기로부터 얻은 천장관절염 환자의 영상에서 장골의 GT(Ground Truth)를 생성하였으며, 대장 용종 검출을 위한 세그멘테이션 모델인 PraNet과 지역 특징 간의 표현 능력을 활용할 수 있는 Position Attention Module을 사용하여 유의미한 성능 향상을 보여주었다.

  • PDF

Generation Method of 3D Human Body Level-of-Detail Model for Virtual Reality Device using Tomographic Image (가상현실 장비를 위한 단층 촬영 영상 기반 3차원 인체 상세단계 모델 생성 기법)

  • Wi, Woochan;Heo, Yeonjin;Lee, Seongjun;Kim, Jion;Shin, Byeong-Seok;Kwon, Koojoo
    • The Journal of Korean Institute of Next Generation Computing
    • /
    • v.15 no.4
    • /
    • pp.40-50
    • /
    • 2019
  • In recent years, it is important to visualize an accurate human body model for the low-end system in the medical imaging field where augmented reality technology and virtual reality technology are used. Decreasing the geometry of a model causes a difference from the original shape and considers the difference as an error. So, the error should be minimized while reducing geometry. In this study, the organ areas of a human body in the tomographic images such as CT or MRI is segmented and 3D geometric model is generated, thereby implementing the reconstruction method of multiple resolution level-of-detail model. In the experiment, a virtual reality platform was constructed to verify the shape of the reconstructed model, targeting the spine area. The 3D human body model and patient information can be verified using the virtual reality platform.

Case study on the couple therapy for family violence : Focusing on the wife residing in a shelter (가정폭력에 대한 부부치료 사례 분석 : 가정폭력 쉼터에 거주하는 부인을 대상으로)

  • Park, Tai-Young;Park, So-Young
    • Journal of Families and Better Life
    • /
    • v.28 no.5
    • /
    • pp.75-88
    • /
    • 2010
  • This study analyzed a family therapy case which dealt with family violence and was consisted of 14 sessions. The therapeutic perspective for this case was MRI model, a strategic family therapy model which emphasizes attempted solutions and interactions. The results of this study were as follows. This study found the interaction process of occurring family violence. When the husband attempted conversations with his wife after drinking, the wife who was anxious and dreadful avoided conversation. This avoidance made the husband felt rejected feeling, and he battered his wife. The avoidance of conversation, an attempted solution of wife, was made from her frame of reference which was affected from her original family context and the couple's communication style in ordinary times. The therapist made the couple recognize their attempted solutions were not effective, and he helped them begin new solutions or coping behaviors. This intervention process was long and hard, but the couple changed their attempted solutions to new solutions which were clear communication styles and functional interaction process. This study results showed the effectiveness of couple therapy on family violence. The effectiveness of MRI model was also proved from the study. The results of study will be helpful to the family therapists and counsellors in the field of family violence.

On NeMRI-Based Multicasting for Network Mobility (네트워크 이동성을 고려한 NeMRI 기반의 멀티캐스트 라우팅 프로토콜)

  • Kim, Moon-Seong;Park, Jeong-Hoon;Choo, Hyun-Seung
    • Journal of Internet Computing and Services
    • /
    • v.9 no.2
    • /
    • pp.35-42
    • /
    • 2008
  • Mobile IP is a solution to support mobile nodes, however, it does not handle NEtwork MObility (NEMO). The NEMO Basic Support (NBS) protocol ensures session continuity for all the nodes in the mobile network. Since the protocol is based on Mobile IP, it inherits the same fundamental problem such as tunnel convergence, when supporting the multicast for NEMO. In this paper, we propose the multicast route optimization scheme for NEMO environment. We assume that the Mobile Router (MR) has a multicast function and the Nested Mobile Router Information (NeMRI) table. The NeMRI is used to record o list of the CoAs of all the MRs located below it. And it covers whether MRs desire multicast services. Any Route Optimization (RO) scheme can be employed here for pinball routing. Therefore, we achieve optimal routes for multicasting based on the given architecture. We also propose cost analytic models to evaluate the performance of our scheme. We observe significantly better multicast cost in NEMO compared with other techniques such as Bi-directional Tunneling, Remote Subscription, and Mobile Multicast based on the NBS protocol.

  • PDF

The variation of biomimetic knee joint movement according to 3D shape information (3차원 형상정보에 따른 생체모방형 무릎관절 구동의 변화)

  • Jeong, Hoon-Jin;Lee, Seung-Jae
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.3
    • /
    • pp.81-86
    • /
    • 2015
  • We fabricated a 3D knee joint model through the imaging processing. The 3D shape information is different depends on specific conditions when the shape of real knee joint is extracted from CT/MRI sliced images. The two types of joint models were fabricated by using 3D printer in order to analysis of joint movement by slight difference of 3D shape information. The compressive force experiments were performed by using knee joint model. As the results, the compressive forces were changed with respect to the difference of geometry. Consequently, feasibility test should be performed before developing biomimetic bioreactor.

Context-Dependent Classification of Multi-Echo MRI Using Bayes Compound Decision Model (Bayes의 복합 의사결정모델을 이용한 다중에코 자기공명영상의 context-dependent 분류)

  • 전준철;권수일
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.179-187
    • /
    • 1999
  • Purpose : This paper introduces a computationally inexpensive context-dependent classification of multi-echo MRI with Bayes compound decision model. In order to produce accurate region segmentation especially in homogeneous area and along boundaries of the regions, we propose a classification method that uses contextual information of local enighborhood system in the image. Material and Methods : The performance of the context free classifier over a statistically heterogeneous image can be improved if the local stationary regions in the image are disassociated from each other through the mechanism of the interaction parameters defined at he local neighborhood level. In order to improve the classification accuracy, we use the contextual information which resolves ambiguities in the class assignment of a pattern based on the labels of the neighboring patterns in classifying the image. Since the data immediately surrounding a given pixel is intimately associated with this given pixel., then if the true nature of the surrounding pixel is known this can be used to extract the true nature of the given pixel. The proposed context-dependent compound decision model uses the compound Bayes decision rule with the contextual information. As for the contextual information in the model, the directional transition probabilities estimated from the local neighborhood system are used for the interaction parameters. Results : The context-dependent classification paradigm with compound Bayesian model for multi-echo MR images is developed. Compared to context free classification which does not consider contextual information, context-dependent classifier show improved classification results especially in homogeneous and along boundaries of regions since contextual information is used during the classification. Conclusion : We introduce a new paradigm to classify multi-echo MRI using clustering analysis and Bayesian compound decision model to improve the classification results.

  • PDF

Study on the Human Influence according to RF Pulse Intensity by use Dental Implant on BRAIN MRI: Using the XFDTD Program (Brain MRI 검사 시 치아 임플란트 시술유무와 RF Pulse 세기에 따른 인체 영향에 관한 연구: XFDTD 프로그램을 이용)

  • Choe, Dea-yeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.361-370
    • /
    • 2017
  • In the Brain MRI, RF Pulse is irradiated on the human body in order to acquire an image. At this time, a considerable part of the irradiated RF Pulse energy is absorbed as it is in our body. This will raise the temperature of the human body, but depending on the extent of exposure, it will affect the human body. The change of the SAR and the temperature of the head according to the change of the magnetic field strength is examined. And to investigate the difference in results depending on the use of dental implant. In the human head model, 64 MHz RF Pulse frequency generated from 1.5 T, 128 MHz RF Pulse frequency generated from 3.0 T, and 298 MHz RF Pulse frequency generated from 7.0 T send a frequency and experiment was performed using dental implant using the XFDTD program, we measured the SAR and body temperature changes around the head. The SAR value showed up to about 5800 times the difference at the RF Pulse frequency of 256 MHz, when with dental implant than without dental implant and as the frequency increased, the use of the dental implant increased difference in the SAR value. The change of the temperature of the head showed a temperature rise nearly 2 to 4 times when with dental implant than without dental implant. As the RF Pulse frequency increase, the SAR value increase, but the change of the temperature of the head decrease. Because of as the frequency increase, wavelength is smaller and the more the amount absorbed by the surface of the human. Physiological and biochemical studies of the human body ar necessary through studies of the presence of dental implant and the cause of reaction caused by change in the RF Pulse frequency.

Ischemic Infarcion Model by Middle Cerebral Artery Occlusion using Allogenic Blood Clot in Beagle Dogs (비글견에서 동종혈전 색전술을 이용한 중간대뇌동맥의 허혈성 뇌경색 모델)

  • Kim, Younghwan;Choi, Sooyoung;Lee, Kija;Han, Woosok;Choi, Hojung;Lee, Youngwon
    • Journal of Veterinary Clinics
    • /
    • v.33 no.1
    • /
    • pp.10-15
    • /
    • 2016
  • The purpose of this study was to establish reproducible ischemic infarction model using allogenic blood clot in beagle dogs and identify induced ischemic lesion after middle cerebral artery occlusion using magnetic resonance imaging (MRI) and histopathologic findings. Twenty eight male beagle dogs with no evidence of neurologic disease were experimented. Allogenic embolus was made using a healthy beagle dog. After internal carotid artery (ICA) was exposure, 16G catheter was introduced through the ICA. The dog was administered 0.3 ml blood clot for 15 seconds followed by 3 ml of saline for 15 seconds. MRI scans were performed with 1.5T to evaluate ischemic lesion at 7 days after middle cerebral artery occlusion procedure. Evaluation parameters of MRI include location, distribution, infarction type, margin, shape, mass effect and intensity of T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), fluid attenuated inversion recovery (FLAIR) sequence, diffusion weighted imaging (DWI) and apparent diffusion coefficient (ADC). On MRI, all dogs (28/28) showed focal or multifocal lesion including telencephalon and thalamus lesions, especially caudate nucleus (24/28). These lesions had well-defined margin from adjacent brain parenchyma, none or mild mass effect and various shape. Most of dogs appeared hyperintensity on T1WI, T2WI, FLAIR, and DWI/ADC, corresponding to chronic infarction. These lesions were histopathologically confirmed atrophic changes and unstained lesion. In conclusion, MRI is the useful method to provide information about ischemic infarction in dogs and the best reproducible ischemic infarction model was developed by using allogenic blood clot.