• Title/Summary/Keyword: MRA2

Search Result 171, Processing Time 0.029 seconds

An Experimental Study on the Cause of Signal Inhomogeneity for Magnetic Resonance Angiography Using Phantom Model of Anterior Communicating(A-com) Artery (전교통동맥 모형을 이용한 자기공명혈관촬영술의 신호 불균일에 관한 실험적 연구)

  • Yoo, Beong-Gyu;Chung, Tae-Sub
    • Journal of radiological science and technology
    • /
    • v.25 no.1
    • /
    • pp.55-62
    • /
    • 2002
  • Aneurysm-mimicking findings were frequently visualized due to hemodynamical causes of dephasing effects around area of A-com artery during magnetic resonance angiography(MRA) and these kind of phenomena have not been clearly known yet. We investigated the hemodynamical patterns of dephasing effect around area of the A-com artery that might be a cause of false intracranial aneurysms on MRA. For experimental study, We used hand-made silicon phantoms of the asymmetric A-com artery as like a bifurcation configuration. In a closed circulatory system with UHDC computer driven cardiac pump system. MRA and fast digital subfraction angiography(DSA) involved the use of these phantoms. Flow patterns were evaluated with axial and coronal imaging of MRA(2D-TOF, 3D-TOF) and DSA of Phantoms constructed from an automated closed-type circulatory system filled with glycerol solution [circulation fluid(glycerol:water = 1:1.4)]. These findings were then compared with those obtained from computational fluid dynamic(CFD) for inter-experimental correlation study. Imaging findings of MRA, DSA and CFD on inflow zone according to the following: a) MRA demonstrated high signal intensity zone as inflow zone on silicon phantom; b) Patterns of DSA were well matched with MRA on trajectory of inflow zone; and c) CFD were well matched with MRA on the pattern of main flow. Imaging findings of MRA. DSA and CFD on turbulent flow zone according to the following: a) MRA demonstrated hyposignal intensity zone at shoulder and axillar zone of main inflow; b) DSA delineated prominent vortex flow at the same area. The hemodynamical causes of signal defect, which could Induce the false aneurysm on MRA, turned out to be dephasing effects at axilla area of bifurcation from turbulent flow as the results of MRA, DSA and CFD.

  • PDF

A Study on the Trade-Economic Effects and Utilization of AEO Mutual Recognition Agreements

  • LEE, Chul-Hun;HUH, Moo-Yul
    • The Journal of Industrial Distribution & Business
    • /
    • v.11 no.2
    • /
    • pp.25-31
    • /
    • 2020
  • Purpose: The AEO (Authorized Economic Operator) program, created in 2001 in the United States due to 9.11 terrorist's attack, fundamentally changed the trade environment. Korea, which introduced AEO program in 2009, has become one of the world's top countries in the program by ranking 6th in the number of AEO certified companies and the world's No. 1 in MRA (Mutual Recognition Agreement) conclusions. In this paper, we examined what trade-economic and non-economic effects the AEO program and its MRA have in Korea. Research design, data and methodology: In this study we developed a model to verify the impact between utilization of AEO and trade-economic effects of the AEO and its MRA. After analyzing the validity and reliability of the model through Structural Equation Model we conducted a survey to request AEO companies to respond their experience on the effects of AEO program and MRA. As a result, 196 responses were received from 176 AEO companies and utilized in the analysis. Results: With regard to economic effects, the AEO program and the MRA have not been directly linked to financial performance, such as increased sales, increased export and import volumes, reduced management costs, and increased operating profit margins. However, it was analyzed that the positive effects of supply chain management were evident, such as strengthening self-security, monitoring and evaluating risks regularly, strengthening cooperation with trading companies, enhancing cargo tracking capabilities, and reducing the time required for export and import. Conclusions: When it comes to the trade-economic effects of AEO program and its MRA, AEO companies did not satisfy with direct effects, such as increased sales and volume of imports and exports, reduced logistics costs. However, non-economic effects, such as reduced time in customs clearance, freight tracking capability, enhanced security in supply chain are still appears to be big for them. In a rapidly changing trade environment the AEO and MRA are still useful. Therefore the government needs to encourage non-AEO companies to join the AEO program, expand MRA conclusion with AEO adopted countries especially developing ones and help AEO companies make good use of AEO and MRA.

Pathology of the Rotator Cuff in Adhesive Capsulitis Patients (견관절 유착성 관절 낭염 환자에 동반된 회전근 개 병변)

  • Yoo, Jae-Chul;Ahn, Jin-Hwan;Kim, Jae-Hoon;Chang, Moon-Jong;Seo, Hee-Soo;Sul, Eun-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.1
    • /
    • pp.24-31
    • /
    • 2007
  • Purpose: To evaluate any combined rotator cuff pathologies in adhesive capsulitis patients with magnetic resonance arthrography (MRA) or ultrasonography (USG), and to see any differences in findings between MRA and USG. Materials and Methods: From June to December 2005, 80 consecutive patients with adhesive capsulitis were prospectively evaluated with either MRA or USG. Two groups were randomly assigned for examination. Evaluation were focused on any combined rotator cuff pathologies especially supraspinatus tendon. Results: Small (less than 1 cm) full-thickness SSP tendon tear were seen in 6 patients (MRA 4, USG 2, 8%) and partial-thickness SSP tendon tears in 21 (MRA 12, USG 9, 26%). In addition, supraspinatus tendinopathy were seen in 15 patients (MRA 7, USG 8, 19%). Overall, various SSP pathologies were reported in 42 patients (53%) of the study objects (MRA 23, 68% and USG 19, 41%). Subscapularis tendon partial tears were reported in 9 patients (MRA 6, USG 3, 11%). There were no statistical differences of the findings between MRA and USG in detecting rotator cuff pathologies (p>0.5). Conclusion: Nearly one half of the adhesive capsulitis patients showed various supraspinatus tendon pathology in MRA or USG. Although MRA group showed slight higher percentage of associated rotator cuff pathology than USG group (without statistical significance), this could be attributed to better resolution capacity of MRA than USG.

  • PDF

Secondary structure analysis of MRA1997 from Mycobacterium tuberculosis and characterization of DNA binding property

  • Kim, Hyo Jung;Lee, Ki-Young;Kim, Yena;Kwon, Ae-Ran;Lee, Bong-Jin
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.20 no.2
    • /
    • pp.36-40
    • /
    • 2016
  • MRA1997 is a highly conserved protein from mycobacterial strains. However, no structural and functional information is associated with it. Thus, to obtain details about structure and function of this protein, we have utilized NMR spectroscopy. The recombinant MRA1997 was highly purified and its DNA binding mode was characterized. The tertiary structure of MRA1997 was modeled on the basis of our NMR chemical shift data combined with the webserver CS23D. The binding of MRA1997 with DNA was first monitored by electrophoresis mobility shift assays. The residues involved in DNA binding are identified using NMR chemical shift perturbation experiments. Based on our study, we suggest that MRA1997 interacts with DNA and may play an important role in Mycobacterium tuberculosis physiology.

The Research to Correct Overestimation in TOF-MRA for Severity of Cerebrovascular Stenosis (3D-SPACE T2 기법에 의한 TOF-MRA검사 시 발생하는 혈관 내 협착 정도의 측정 오류 개선에 관한 연구)

  • Han, Yong Su;Kim, Ho Chul;Lee, Dong Young;Lee, Su Cheol;Ha, Seung Han;Kim, Min Gi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.180-188
    • /
    • 2014
  • It is very important accurate diagnosis and quick treatment in cerebrovascular disease, i.e. stenosis or occlusion that could be caused by risk factors such as poor dietary habits, insufficient exercise, and obesity. Time-of-flight magnetic resonance angiography (TOF-MRA), it is well known as diagnostic method without using contrast agent for cerebrovascular disease, is the most representative and reliable technique. Nevertheless, it still has measurement errors (also known as overestimation) for length of stenosis and area of occlusion in celebral infarction that is built by accumulation and rupture of plaques generated by hemodynamic turbulence. The purpose of this study is to show clinical trial feasibility for 3D-SPACE T2, which is improved by using signal attenuation effects of fluid velocity, in diagnosis of cerebrovascular disease. To model angiostenosis, strictures of different proportions (40%, 50%, 60%, and 70%) and virtual blood stream (normal saline) of different velocities (0.19 ml/sec, 1.5 ml/sec, 2.1 ml/sec, and 2.6 ml/sec) by using dialysis were made. Cross-examinations were performed for 3D-SPACE T2 and TOF-MRA (16 times each). The accuracy of measurement for length of stenosis was compared in all experimental conditions. 3D-SPACE 2T has superiority in terms of accuracy for measurements of the length of stenosis, compared with TOF-MRA. Also, it is robust in fast blood stream and large stenosis than TOF-MRA. 3D-SPACE 2T will be promising technique to increase diagnosis accuracy in narrow complex lesions as like two cerebral small vessels with stenosis, created by hemodynamic turbulence.

The 3-Phase Induction Motor Speed Control by the MRA-DSM controller (MRA-DSM 제어기를 이용한 3상 유도전동기의 속도 제어)

  • 원영진;한완옥;박진홍;이종규;이성백
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.1
    • /
    • pp.54-62
    • /
    • 1995
  • This paper is a study on a speed control of an induction motor used the MRA-DSM(Mode1 Reference Adaptive-Discrete Sliding Mode) controller. In this paper, when controls motor speed, DSM algorithm is proposed for having Robustness against disturbance and parameter variation. and it is also proposed MRA-DSM including the additional load model reference algorithm, which can be compensated the discontinuous control imputs at sliding mode and followed the model Preference independent of parameter variation of control subjects. The control system is composed of the parallel processing control system using the microprocessor for maximizing the performance of control systems and the real time processing. Also it simplifies the hardware composed of controlling the system by software and improves the reliability of the system. And while MRA-DSM control, faster response characteristics of 27.2 % is obtained than DSM control.

  • PDF

The Usefulness of the 3-D Overlapped Reconstruction MR Angiographic Technique in Patients with Hemifacial Spasm - A Preliminary Study (반얼굴 연축 환자에서 삼차원 중첩 자기공명 혈관 조영술 기법의 유용성-초기 보고)

  • Lee, Yoon-Mi;Park, Sun-Won;Pyun, Hae-Wook;Yoon, Myung-Kwan;Kim, Eun-Young;Suh, Chang-Hae;Lim, Myung-Kwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.33-38
    • /
    • 2007
  • Purpose : To investigate the applicability of the new three-dimensional overlapped reconstruction MR angiography (3-D ORMRA) technique in patients with hemifacial spasm and to compare the new 3-D reconstruction images with conventional MRA source images. Materials and Methods : The study group comprised 27 patients with surgically proven hemifacial spasm. In all patients, conventional MRA source images and 3-D fast imaging employing steady-state acquisition (FIESTA) images were obtained prospectively. After 3-D MR angiographic images were obtained, the 3-D MRA and FIESTA images were overlapped at the workstation by using GE A/W 4.2 add/sub software. We analyzed the relationship between the offending vessels and root exit zone of the facial nerve using both 3-D ORMRA images and conventional MRA source images. Results : In 25 of 27 patients, the offending vessel at the REZ of the facial nerve could be correctly identified on conventional MRA source images. In all patients, the presumed offending vessels depicted by the overlapped 3-D reconstruction MRA image corresponded well with the intraoperative findings. The 3-D reconstruction image showed more clear visualization of the spatial relationship between the offending vessels and the root exit zone of the facial nerve. Conclusion : The overlapped 3-D reconstruction MR angiography technique is very useful and informative in patients with hemifacial spasm, as compared with conventional MRA angiography technique.

  • PDF

Contested Technologies, Resetting the Boundary, and the "signifiant-politics": Semiotical Governance of New Technology in the Case of fMRA (경합하는 기술, 경계의 재설정, 그리고 기표-정치(signifiant-politics): 기능성자기공명혈관조영술(fMRA)의 사례로 살펴본 신기술의 명명 작업)

  • Lee, June-Seok
    • Journal of Science and Technology Studies
    • /
    • v.14 no.2
    • /
    • pp.199-222
    • /
    • 2014
  • Functional Magnetic Resonance Angiography (fMRA) was a technoscientific innovation that allows scientists to directly view the changes made in the blood vessels of a brain. fMRA was first developed at Neuroscience Research Institute (NRI) in Korea. fMRA mainly utilizes 7 Tesla MRI technology, and NRI is equipped with the instrument. First article on fMRA was published in 2008, and two more papers in 2010 and 2012 consecutively had been published on the newly developed technique. However, fMRA is a competitive technology with existing fMRI. Both techniques capture microvascular changes in a brain, and by doing it, both techniques visualize the cognitive and affective changes. fMRI technology was introduced by Seiji Ogawa in the early 1990's and has been widely used since then. In contrast, fMRA was a newer technology and rather unknown. Developers of fMRA in NRI used series of signifiant-politics in order to make it better known to scientific community as well as public. By resetting the boundaries of existing concept of fMRI, they tried to lower the threshold of a new concept/technique. This case study shows how technoscientists use semiotic strategies governing new technology.

  • PDF

Frame Multiresolution Analysis

  • Kim, Hong-Oh;Lim, Jae-Kun
    • Communications of the Korean Mathematical Society
    • /
    • v.15 no.2
    • /
    • pp.285-308
    • /
    • 2000
  • We generalize bi-orthogonal (non-orthogona) MRA to frame MRA in which the family of integer translates of a scaling func-tion forms a frame for the initial ladder space V0. We investigate the internal structure of frame MRA and establish the existence of a dual scaling function, and show that, unlike bi-orthogonal MRA, there ex-ists a frame MRA that has no (frame) 'wavelet'. Then we prove the existence of a dual wavelet under the assumption of the existence of a wavelet and present easy sufficient conditions for the existence of a wavelet. Finally we give a new proof of an equivalent condition for the translates of a function in L2(R) to be a frame of its closed linear span.

  • PDF

Effects of Flow Rates and CS Factors on TOF MRA using Compressed Sensing (Compressed sensing을 이용한 TOF MRA 검사에서 Flow rate와 CS factor의 변화에 따른 영향)

  • Kim, Seong-Ho;Jeong, Hyun-Keun;Yoo, Se-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.281-291
    • /
    • 2021
  • This study aimed to measure the quantitative changes in images according to the use of compressed sensing in expressing the slow flow rate in TOF MRA test using magnetic resonance imaging. This study set different blood flow rate sections by using auto-injector and flow phantom and compared changes in the SNR, CNR, SSIM, and RMSE measurements by different CS factors between TOF with CS and TOF without CS. One-way ANOVA was performed to test the effect on the image induced by the increase of the CS factor. The results revealed that TOF MRA with CS significantly decreased scan time without significantly affecting SNR and CNR compared to TOF MRA with CS. On the other hand, the differences in SSIM and RMSE between TOF with CS and TOF without CS increased as the CS factor increased. Therefore, it is necessary to efficiently reduce scan time by adapting the CS technique while considering the appropriate range of the CS factor. Additionally, more studies are needed to evaluate CS factors and the similarity precision of images further.