Design of MR damper with multi_stage core (다중 자기 코일 작동기를 사용한 MR damper의 설계해석)

  • Lee, Gyu-Seop;Yoo, Won-Hee;Ryu, Bong-Jo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.525-528
    • /
    • 2008
  • The dynamic range of MR damper is the most important characteristics for the usage of semi-active control system. The damping force can be increased by simply decresing the orifice gap in the traditional oil damper, but it deteriorate the dynamic range in MR damper. In this paper, the multi-stage electro-magnetic core is suggested to maintain the performance of MR damper with a large damping force. The MR damper with 3 stage core is designed and manufactured for testing and analysis.

  • PDF

Development of a Round endmill Type MR Polishing System Using Neodymium Magnets (네오디뮴 자석을 이용한 라운드 엔드밀 타입 MR연마 시스템 개발)

  • Hong, Kwang-Pyo;Shin, Bong-Cheol;Kim, Dong-Woo;Cho, Myeong-Woo;Je, Tae-Jin
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.3
    • /
    • pp.316-321
    • /
    • 2011
  • Recently, it has been studied machining of micro parts with increasing demands for ultra precision parts. However, many engineering problems have already begun in polishing of optical parts or lens. As a method to overcome such problems, a new technology for the polishing of the target surface is being studied by controlling abrasives using MR fluids which are sensitive to magnetic fields. Since the current MR polishing system uses a big electromagnet, and is difficult to polish micro parts or spherical lens. Therefore, in this study, a round endmill type MR polishing system was developed to polish a three-dimensional structure which has spherical or inclined plane. And then, series of experiments were performed to verify the polishing performance of the developed round endmill type MR polishing system.

3D Non-Rigid Registration for Abdominal PET-CT and MR Images Using Mutual Information and Independent Component Analysis

  • Lee, Hakjae;Chun, Jaehee;Lee, Kisung;Kim, Kyeong Min
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.5
    • /
    • pp.311-317
    • /
    • 2015
  • The aim of this study is to develop a 3D registration algorithm for positron emission tomography/computed tomography (PET/CT) and magnetic resonance (MR) images acquired from independent PET/CT and MR imaging systems. Combined PET/CT images provide anatomic and functional information, and MR images have high resolution for soft tissue. With the registration technique, the strengths of each modality image can be combined to achieve higher performance in diagnosis and radiotherapy planning. The proposed method consists of two stages: normalized mutual information (NMI)-based global matching and independent component analysis (ICA)-based refinement. In global matching, the field of view of the CT and MR images are adjusted to the same size in the preprocessing step. Then, the target image is geometrically transformed, and the similarities between the two images are measured with NMI. The optimization step updates the transformation parameters to efficiently find the best matched parameter set. In the refinement stage, ICA planes from the windowed image slices are extracted and the similarity between the images is measured to determine the transformation parameters of the control points. B-spline. based freeform deformation is performed for the geometric transformation. The results show good agreement between PET/CT and MR images.

Financial Data Assessment Using Table-Graph-Mixed Reality Visualization

  • Tanlamai, Uthai;Savetpanuvong, Phannaphatr;Kunarittipol, Wisit
    • Journal of Information Technology Applications and Management
    • /
    • v.19 no.1
    • /
    • pp.13-24
    • /
    • 2012
  • Usability and knowledge drawn from utilizing various ways of representing accounting data were examined. Classroom experiments were conducted to compare students' assessment of financial data using table of numbers, 2-dimensional column graphs (2D), 3-dimensional column graphs (3D), and mixed reality visualization of true 3-dimensional graphs (MR). The results showed that in assessing the financial status and performance of a firm, Table of numbers and MR took longer than 2D and 3D graphs. The time spent on true 3D graphs using MR technology was about the same as Table of numbers. When compared the assessment scores of the firm's financial status and performance between participants and experts, the difference was the least when participants used 2D graphs. However, MR was seen as being a new way to provide data of greater complexity and was very useful for financial information.

Diagnosis of Subclavian Steal: Contrast Enhanced 3D MR Angiography vs 2D TOF

  • 이호규;김건언;최중곤;서대철
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.136-136
    • /
    • 2001
  • Purpose: Subclavian steal refers to the retrograde flow of blood in a vertebral artery that supplies t ipsilateral shoulder and arm caused by proximal subclavian artery stenosis or occlusion. T purpose of this exhibit is to demonstrate MR findings of subclavian steal on contrast-enhanc 3D (CE 3DMRA) and 2D TOF MR angiography. Method: Four patients(men 3 and women 1, age: 28-78years) with subclavian steal obtained both CE 3DMRA and digital subtraction angiography(DSA) including subclavian arterie Sequential imaging was undertaken during first pass after double dose of Gd-DTPA (0 mM/kg) Injected by a power injector. Coronal source images were obtained with coronal D-fast low angle shot sequence(TR/TE/flip angle=3.8/l.3/35, acquisition time= 10sec/one measurement). Precontrast imaging was subtracted from enhanced images and maximu intensity projection was done. 2D time-of-flight MR angiography(2D TOF) of the carot bifurcation was added in all cases with post-saturation. All studies were review retrospectively.

  • PDF

Phenomenological Damping Flow Modeling and Performance Evaluation for a Continuous Damping Control Damper Using MR Fluid (MR 유체를 이용한 연속 감쇠력 가변형 댐퍼를 위한 감쇠유동의 현상학적 모델링과 성능평가)

  • Park, Jae-Woo;Jung, Young-Dae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.73-82
    • /
    • 2008
  • Recently MR CDC damper has been applied to semi-active suspension control system gradually. Compared to former hydraulic CDC damper, it has rapid time response performance as well as simple internal structure and wide range of damping force. In order to develop control logic algorithm which enables to take maximum advantage of unique characteristics of MR CDC damper, it is inevitable to perform a thorough investigation into its nonlinear performance. In many previous researches, MR fluid model was either simply assumed as Bingham Plastic, or a phenomenological model based on experiment was established instead to predict damping performance of MR CDC damper. These experimental flow model which is not based on flow analysis but intentionally built to fit damping characteristics, may lead to totally different results in case of different configuration or structure of MR CDC damper. In this study, a generalized flow formula from mathematical flow model of MR fluid for annular orifice is derived to analyze and predict damping characteristics when current is excited at piston valve.

Magnetic Resonance Imaging in Thoracic Disease (흉부질환의 자기공명영상)

  • Song, Koun-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.4
    • /
    • pp.345-352
    • /
    • 1993
  • The role of magnetic resonance(MR) imaging in the evaluation of thoracic disease has been limited Nontheless, MR has inherent properties of better contrast resolution than CT allowing tissue-specific diagnosis. MR has capability of direct imaging in sagittal, coronal, and oblique planes which provide better anatomic information than axial images of CT such as lesions in the pulmonary apex, aorticopulmonary window, peridiaphragmatic region, and subcarinal region. MR is sensitive to blood flow making it an ideal imaging modality for the evaluation of cardiovascular system of the thorax without the need for intravenous contrast media. Technical developments and better control of motion artifacts have resulted in improved image quality, and clinical applications of MR imaging in thoracic diseases have been expanded. Although MR imaging is considered as a problem-solving tool in patients with equivocal CT findings, MR should be used as the primary imaging modality in the following situations: 1) Evaluation of the cardiovascular abnormalities of the thorax 2) Evaluation of the superior sulcus tumors 3) Evaluation of the chest wall invasion or mediastinal invasion by tumor 4) Evaluation of the posterior mediastinal mass, especially neurogenic tumor 5) Differentiation of fibrosis and residual or recurrent tumor, especially in lymphoma 6) Evaluation of brachial plexopathy With technical developments and fast scan capabilities, clinical indications for MR imaging in thorax will increase in the area of pulmonary parenchymal and pulmonary vascular imaging.

  • PDF

Fully coupled multi-hull/mooring/riser/hawser time domain simulation of TLP-TAD system with MR damper

  • Muhammad Zaid Zainuddin;Moo-Hyun Kim;Chungkuk Jin;Shankar Bhat
    • Ocean Systems Engineering
    • /
    • v.13 no.4
    • /
    • pp.401-421
    • /
    • 2023
  • Reducing hawser line tensions and dynamic responses to a certain level is of paramount importance as the hawser lines provide important structural linkage between 2 body TLP-TAD system. The objective of this paper is to demonstrate how MR Damper can be utilized to achieve this. Hydrodynamic coefficients and wave forces for two bodies including second-order effects are obtained by 3D diffraction/radiation panel program by potential theory. Then, multi-hull-riser-mooring-hawser fully-coupled time-domain dynamic simulation program is applied to solve the complex two-body system's dynamics with the Magneto-Rheological (MR) Damper modeled on one end of hawser. Since the damping level of MR Damper can be changed by inputting different electric currents, various simulations are conducted for various electric currents. The results show the reductions in maximum hawser tensions with MR Damper even for passive control cases. The results also show that the hawser tensions and MR Damper strokes are affected not only by input electric currents but also by initial mooring design. Further optimization of hawser design with MR Damper can be done by active MR-Damper control with changing electric currents, which is the subject of the next study.

Mitral Valve Reconstruction; Result of Operation Using Prosthetic Ring (승모판막 재건술;인공판륜[prosthetic ring]을 이용한 수술례)

  • 이재원
    • Journal of Chest Surgery
    • /
    • v.26 no.3
    • /
    • pp.191-195
    • /
    • 1993
  • Among 25 consecutive cases having undergone mitral valve surgery between March 1991 and June 1992 in Gill General Hospital, 11 patients[44%] who had undergone mitral valve reconstruction using prosthetic rings is evaluated and presented. Patients` mean age is 43 + 19 years[range:16-72], and they are consisted with 4 males and 7 females. Mitral valve insufficiency is due to degenerative disease in 6 cases[55%] and rheumatic disease in 5 patients[45%]. Carpentier`s functional classification I is 2 cases, II is 6 cases, and III is 2 cases. Surgical techniques include prosthetic ring annuloplasty[11 patients, 100%], chorda shortening[6, 55%], leaflet mobilization[4,36%], new chorda formation[2, 18%], chorda transposition[1, 9%] commissurotomy[3, 27%], and papillary muscle splitting[3, 27%]. Average number of mitral anatomic lesions per patient are 2.7 and we used average 2.8 procedures upon mitral valve apparatus per patient. There were no surgical mortality and no late valve related admission during the mean follow up period of 17 months. The mean functional class[NYHA] is 2.81 preoperatively and improved to 1.10 postoperatively. Doppler echocardiography showed much improvement from grade II MR [1 case], grade III MR [1 case] and 9 cases of grade IV MR to 6 cases of patients showed no MR, only trace MR in 4 cases, and grade I MR was found only in one patient with NYHA functional class II postoperatively. The postoperative mean mitral valve area is $2.10+0.28cm^2$. We conclude that mitral reconstruction is a predictable and stable operation.

  • PDF

The Magnetoresistance effects of number of layers and magnetic anisotropic in [NiFe/Cr] Multilayers (NiFe/Cr 다층박막의 층수와 자기이방성에 따른 자기저항특성)

  • 황도근;이상석;박창만;이기암
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.3
    • /
    • pp.210-215
    • /
    • 1995
  • $Glass\Cr_{40\AA}\{[Cr_{10\AA}\NiFe_{50\AA}]}_N$ multilayers (number of layer N = 1, 2, 3, 4, 5, 6, 10) were made by dc magnetron sputtering under magnetic anisotropy of 200 G. Magnetoresistance curve MR(xx), MR(xy) were measured for the parallel and perpendicular current direction to external magnetic field. MR(xx) curves for the number of layer N=1, 5, 10 were almost became about zero percent, however the curves of other numbers appeared the phenomena of "positive magnetoresistance" that the resistance increased to external magnetic field, and the irregular and reversed curves in the vicinity of H=0 Oe.

  • PDF