• Title/Summary/Keyword: MR3

Search Result 1,596, Processing Time 0.034 seconds

Endovaginal and Endorectal Surface Coils for in-ViVo Human MR Imaging and Spectroscopy (자궁경부암 진단용 MR 질내표면코일과 전립선암 진단용 MR 경직장표면코일의 제작 : 인체에서의 MR 영상과 MR 분광)

  • 문치웅;조경식
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.481-491
    • /
    • 1995
  • Endovaginal and endorectal receiver only surface coils were designed for MR imaging (MRI) and $^1H$ MR spectroscopy (MRS) for the uterine cervix and the prostate. The shape of endovaginal coil wire was rectangular with round corner. Size of the coil wire was empirically determined for 7cm and 4cm along the long and short axis, respectively. The coil wire loop was supported by acryl handle and bent about $150^{\circ}$ at one side of the loop considering the average angle of the cervix to the vagina. We called this as a "spoon-type endovaginal coil". The wire of the endorectal coil was made of the flexible materials so that the wire loop became long elliptic shape by pushing the acryl handle into the plastic tube for the comfort of patients when the coil was inserted into the cervix. Then, the shape was maintained to be circle by popping out handle. Conventional spin echo (SE) and fast spin echo (FSE) sequences were used as 71 and 72 weighted imaging sequences, respectively. Matrix size was 128~$256{\times}256$. FOVs for surface coil and body coil were 14cm and 24cm, respectively. 3D volume localized in vivo $^1H$ MR spectroscopy of the human cervix and prostate was performed using PRESS or STEAM localization method with the following parameters . TR=3 sec, TE=135 msec for PRESS or 30 msec for STEAM, NEX=2, NS=48, Sl=2048, and SW=2500 Hz. Using home-built endovaginal and endorectal coils, excellent T1- and T2-images were obtained to visualize early cervical and prostate tumors. 3D volume localized in vivo IH MRS was useful to differentiate the cancerous tissue from the normal tissue.

  • PDF

SOME PROPERTIES OF GM MODULES AND MR GROUPS

  • Cho, Yong Uk
    • Korean Journal of Mathematics
    • /
    • v.16 no.3
    • /
    • pp.281-290
    • /
    • 2008
  • The purpose of this paper, GM modules are defined as a generalization of AGR rings. Also, from the faithful GM-property, we get a commutativity of rings. Finally, for a nearring R, we will introduce MR groups, and also derive some properties of GM modules and MR groups.

  • PDF

Development of DNA Hybridization Detection Sensors and Analysis of Characteristics Using Electrochemical methods (전기화학법을 이용한 DNA Hybridization 검출 센서의 개발 및 특성 해석)

  • Ock, Jin-Young;Kim, Do-Kyun;Chang, Jeong-Soo;Kwon, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.260-262
    • /
    • 2002
  • The determination of DNA hybridization can apply the molecular biology research. clinic diagnostics. bioengineering, environment monitoring, food science and other application area. So, The determination of hybridization is very important for the improvement of DNA detection system. In this study, we report the characterization of the DNA hybridization by the electricalchemical methods. The probe oligonucleotide was used to determine the amount of target oligonucleotide in solution using Methylen Blue(MB) as the electrochemical indicators. The cathodic peak currents($I_{peak}$) of MB were linearly related to the concentration of the target oligonucleotide sequence in the range $1[{\mu}M]{\sim}0.1[{\mu}M]$. The detection limit of this approach was 0.01[nM]. As a result, the match oligonucleotide(CR-1) was most stable state and the peak of redox current measured by DNA hybridization detection sensors by using electrochemical method seem to be similar to 1-mer terminal mismatch oligonucleotide(MR-3). The MR-2, MR-3, MR-22 and MR-33 have each mismatching sequence of central and terminal. With this set the role of point mutations was to be investigated. Terminal mismatch oligonucleotide (MR-3, 33) is shown more stable state than central mismatch oligonucleotide(MR-2, 22). And 1-mer mismatch oligonucleotide(MR-2 or 3) is shown more stable state than 2-mer mismatch oligonucleotide(MR-22 or 33).

  • PDF

Skeletal Sarcomas Examined with MR in Tubular and CT in Flat Bones (골격계 육종에서 관상골MR과 편평골CT의 유용성)

  • Moon, Tae-Yong;Lee, Young-Joon;Jung, Kyung-Hwa;Hur, Jin-Do;Sol, Mi-Young;Kwon, Woon-Jung
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.2
    • /
    • pp.162-168
    • /
    • 2003
  • Purpose: Primary malignant bone tumors are classified with mesenchymal sarcomas (MS) such as osteosarcoma and chondrosarcoma and small round cell sarcomas (SRS) such as Ewing's sarcoma and lymphoma. Radiological examinations for skeletal sarcoma were using MR scan in tubular bone sarcomas and CT scan in flat bone sarcomas recently. Both MR and CT scans show some findings of bone destruction and soft tissue mass but MR scans don't reveal a finding with mineralization relatively. So we investigated bone destructive pattern of skeletal sarcomas on both MR and CT scans for differentiation of MS and SRS. Materials and Methods: There are 28 MS and 26 SRS examined with MR or CT scans. The findings according to bone destructive pattern were divided to eccentric and concentric in 26 cases of tubular bone sarcomas with MR scan and 28 cases of flat bone sarcomas with CT scan. Results: MR images revealed eccentric destruction in 12 cases of 16 MS and concentric in all cases of 10 SRS (p>.01). CT images showed eccentric destruction in 10 cases of 12 MS and concentric bone destruction in 13 cases of 16 SRS (p>.01) Conclusion: The findings divided to eccentric and concentric bone destructive patterns were useful for differential diagnosis of MS from SRS on both MR and CT scans.

  • PDF

Semi-Active Control System Based on the Experimental Results of the Performance of a Small Scale MR Damper (소형 MR감쇠기의 성능 실험에 기초한 준능동 제어 시스템)

  • Min Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.3 s.73
    • /
    • pp.233-238
    • /
    • 2006
  • In this paper, mixed mode magneto-rheological(MR) damper, which is applicable for vibration control of a small scale multi-story structure, is devised. First, the schematic configurations of the shear, flow, and mixed mode MR dampers are described with design constraints and then the analytical models to predict the field-dependent damping forces are derived for each type. Second, an appropriate size of the mixed mode MR damper is manufactured and its field-dependent damping characteristics are evaluated in time domain. Finally, the performance of the manufactured MR damper which is semi-actively applied to a small scale building excited by earthquake load, is numerically evaluated.

Synthetic Computed Tomography Generation while Preserving Metallic Markers for Three-Dimensional Intracavitary Radiotherapy: Preliminary Study

  • Jin, Hyeongmin;Kang, Seonghee;Kang, Hyun-Cheol;Choi, Chang Heon
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.172-178
    • /
    • 2021
  • Purpose: This study aimed to develop a deep learning architecture combining two task models to generate synthetic computed tomography (sCT) images from low-tesla magnetic resonance (MR) images to improve metallic marker visibility. Methods: Twenty-three patients with cervical cancer treated with intracavitary radiotherapy (ICR) were retrospectively enrolled, and images were acquired using both a computed tomography (CT) scanner and a low-tesla MR machine. The CT images were aligned to the corresponding MR images using a deformable registration, and the metallic dummy source markers were delineated using threshold-based segmentation followed by manual modification. The deformed CT (dCT), MR, and segmentation mask pairs were used for training and testing. The sCT generation model has a cascaded three-dimensional (3D) U-Net-based architecture that converts MR images to CT images and segments the metallic marker. The performance of the model was evaluated with intensity-based comparison metrics. Results: The proposed model with segmentation loss outperformed the 3D U-Net in terms of errors between the sCT and dCT. The structural similarity score difference was not significant. Conclusions: Our study shows the two-task-based deep learning models for generating the sCT images using low-tesla MR images for 3D ICR. This approach will be useful to the MR-only workflow in high-dose-rate brachytherapy.

Analysis of skin movement using MR images (자기공명 영상을 이용한 피부 움직임 분석에 관한 연구)

  • ;Natsuki Miyata;Makiko Kouchi;Masaaki Mochimaru
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.719-722
    • /
    • 2003
  • This paper describes a novel experiment that measures the skin movement of a hand based on MR (magnetic resonance) images in conjunction with surface modeling techniques. The proposed approach consists of 3 phases: (1) MR scanning of a hand with surface makers, (2) 3D reconstruction from the MR images. and (3) registration of the 3D models. The results of registration are used to trace the skin movement with respect to underlying bone motions by measuring the positions of the surface markers.

  • PDF

A Study on Aspheric Optics Research for Improving the Luminous Efficiency of the LED MR16 (LED MR16의 광효율 향상을 위한 비구면 광학계 연구)

  • Yoo, Sook-Chul;Yoo, Kyung-Sun;Hyeon, Dong-Hun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.3
    • /
    • pp.480-487
    • /
    • 2013
  • In this study, we researched the LED source MR16,which maintains the strong points of an ordinary MR16 while compensating for its weak points. The optical system composition of the LED MR16 includes four aspherical lens per sheet and a patterned reflector. The aspherical optical system and reflector were designed using optical software, and the performance was estimated using a lighting simulation program. Finally, a prototype was manufactured after analyzing the simulation data, and the reliability of the simulation results was estimated using a comparative analysis of the designed data and measured data.

An innovative hardware emulated simple passive semi-active controller for vibration control of MR dampers

  • Zhang, Jianqiu;Agrawal, Anil K.
    • Smart Structures and Systems
    • /
    • v.15 no.3
    • /
    • pp.831-846
    • /
    • 2015
  • Magneto-Rheological (MR) dampers are being used increasingly because of their adaptability to control algorithms and reliability of passive systems. In this paper, an extensive investigation on performance of MR dampers in semi-active and passive modes has been carried out. It is observed that the overall energy dissipation by MR dampers in passive-on modes is higher than that in semi-active modes for most of the competitive semi-active controllers. Based on the energy dissipation pattern, a novel semi-active controller, termed as "Simple Passive Semi-Active Controller", has been proposed for MR dampers. This controller can be emulated by a simple passive hardware proposed in this paper. The proposed concept of controller "hardware emulation" is innovative and can also be implemented for other semi-active devices for control algorithms of certain form. The effectiveness and reliability of the proposed controller has been investigated extensively through numerical simulations. It has been demonstrated that the proposed controller is competitive to or more effective than other widely used / investigated semi-active controllers.

Effects of multiple MR dampers controlled by fuzzy-based strategies on structural vibration reduction

  • Wilson, Claudia Mara Dias
    • Structural Engineering and Mechanics
    • /
    • v.41 no.3
    • /
    • pp.349-363
    • /
    • 2012
  • Fuzzy logic based control has recently been proposed for regulating the properties of magnetorheological (MR) dampers in an effort to reduce vibrations of structures subjected to seismic excitations. So far, most studies showing the effectiveness of these algorithms have focused on the use of a single MR damper. Because multiple dampers would be needed in practical applications, this study aims to evaluate the effects of multiple individually tuned fuzzy-controlled MR dampers in reducing responses of a multi-degree-of-freedom structure subjected to seismic motions. Two different fuzzy-control algorithms are considered, a traditional controller where all parameters are kept constant, and a gain-scheduling control strategy. Different damper placement configurations are also considered, as are different numbers of MR dampers. To determine the robustness of the fuzzy controllers developed to changes in ground excitation, the structure selected is subjected to different earthquake records. Responses analyzed include peak and root mean square displacements, accelerations, and interstory drifts. Results obtained with the fuzzy-based control schemes are compared to passive control strategies.