• 제목/요약/키워드: MR3

검색결과 1,634건 처리시간 0.038초

자궁경부암 진단용 MR 질내표면코일과 전립선암 진단용 MR 경직장표면코일의 제작 : 인체에서의 MR 영상과 MR 분광 (Endovaginal and Endorectal Surface Coils for in-ViVo Human MR Imaging and Spectroscopy)

  • 문치웅;조경식
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권4호
    • /
    • pp.481-491
    • /
    • 1995
  • Endovaginal and endorectal receiver only surface coils were designed for MR imaging (MRI) and $^1H$ MR spectroscopy (MRS) for the uterine cervix and the prostate. The shape of endovaginal coil wire was rectangular with round corner. Size of the coil wire was empirically determined for 7cm and 4cm along the long and short axis, respectively. The coil wire loop was supported by acryl handle and bent about $150^{\circ}$ at one side of the loop considering the average angle of the cervix to the vagina. We called this as a "spoon-type endovaginal coil". The wire of the endorectal coil was made of the flexible materials so that the wire loop became long elliptic shape by pushing the acryl handle into the plastic tube for the comfort of patients when the coil was inserted into the cervix. Then, the shape was maintained to be circle by popping out handle. Conventional spin echo (SE) and fast spin echo (FSE) sequences were used as 71 and 72 weighted imaging sequences, respectively. Matrix size was 128~$256{\times}256$. FOVs for surface coil and body coil were 14cm and 24cm, respectively. 3D volume localized in vivo $^1H$ MR spectroscopy of the human cervix and prostate was performed using PRESS or STEAM localization method with the following parameters . TR=3 sec, TE=135 msec for PRESS or 30 msec for STEAM, NEX=2, NS=48, Sl=2048, and SW=2500 Hz. Using home-built endovaginal and endorectal coils, excellent T1- and T2-images were obtained to visualize early cervical and prostate tumors. 3D volume localized in vivo IH MRS was useful to differentiate the cancerous tissue from the normal tissue.

  • PDF

SOME PROPERTIES OF GM MODULES AND MR GROUPS

  • Cho, Yong Uk
    • Korean Journal of Mathematics
    • /
    • 제16권3호
    • /
    • pp.281-290
    • /
    • 2008
  • The purpose of this paper, GM modules are defined as a generalization of AGR rings. Also, from the faithful GM-property, we get a commutativity of rings. Finally, for a nearring R, we will introduce MR groups, and also derive some properties of GM modules and MR groups.

  • PDF

전기화학법을 이용한 DNA Hybridization 검출 센서의 개발 및 특성 해석 (Development of DNA Hybridization Detection Sensors and Analysis of Characteristics Using Electrochemical methods)

  • 옥진영;김도균;장정수;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.260-262
    • /
    • 2002
  • The determination of DNA hybridization can apply the molecular biology research. clinic diagnostics. bioengineering, environment monitoring, food science and other application area. So, The determination of hybridization is very important for the improvement of DNA detection system. In this study, we report the characterization of the DNA hybridization by the electricalchemical methods. The probe oligonucleotide was used to determine the amount of target oligonucleotide in solution using Methylen Blue(MB) as the electrochemical indicators. The cathodic peak currents($I_{peak}$) of MB were linearly related to the concentration of the target oligonucleotide sequence in the range $1[{\mu}M]{\sim}0.1[{\mu}M]$. The detection limit of this approach was 0.01[nM]. As a result, the match oligonucleotide(CR-1) was most stable state and the peak of redox current measured by DNA hybridization detection sensors by using electrochemical method seem to be similar to 1-mer terminal mismatch oligonucleotide(MR-3). The MR-2, MR-3, MR-22 and MR-33 have each mismatching sequence of central and terminal. With this set the role of point mutations was to be investigated. Terminal mismatch oligonucleotide (MR-3, 33) is shown more stable state than central mismatch oligonucleotide(MR-2, 22). And 1-mer mismatch oligonucleotide(MR-2 or 3) is shown more stable state than 2-mer mismatch oligonucleotide(MR-22 or 33).

  • PDF

골격계 육종에서 관상골MR과 편평골CT의 유용성 (Skeletal Sarcomas Examined with MR in Tubular and CT in Flat Bones)

  • 문태용;이영준;정경화;허진도;설미영;권운정
    • 대한골관절종양학회지
    • /
    • 제9권2호
    • /
    • pp.162-168
    • /
    • 2003
  • 목적: 골격을 침해하는 원발성 악성종양으로는 골육종이나 연골육종 같은 간엽성육종과 유윙육종이나 림프종 같은 소원형세포성육종으로 나눈다. 골격육종을 진단하기 위해 관상골 육종은 MR검사를 편평골 육종은 CT검사를 주로 이용한다. MR과 CT는 공히 골파괴병소와 연조직종괴를 잘 나타내지만 무기질침착은 MR에서 식별되기 어렵다. 이에 본저자들은 관상골 MR과 편평골 CT검사의 골파괴 소견으로 간엽성육종과 소원형세포성육종을 감별하고자 하였다. 대상 및 방법: 수술적 조직생검술에 의한 병리조직학적으로 진단되고 관상골 MR 또는 편평골 CT검사를 시행했던 간엽성육종 28례와 소원형세포성육종 26례를 대상으로 하였다. 관상골 MR검사 26례와 편평골CT검사 28례에서 골파괴 병소 소견을 각각 편심성과 중심성으로 나누어 비교 분석하였다. 결과: 관상골 MR검사에서 간엽성육종 16례중 12례(75.0%)가 편심성 골파괴 소견이였고 소원형세포육종 10례는 전례(100.0%)가 중심성 골파괴 소견이었다(p>.01). 편평골 CT검사에서 간엽성육종 12례중 10례(83.3%)에서 편심성 골파괴 소견이었고 소원형세포성육종 16례중 13례(81.3%)가 중심성 골파괴 소견을 보였다(p>.01). 결론: 관상골 MR검사든 편평골 CT검사든 골파괴 양상을 중심성과 편심성으로 나누는 방사선학적 소견은 간엽성육종과 소원형세포성육종을 감별 진단하는데 도움이 되는 소견이었다.

  • PDF

소형 MR감쇠기의 성능 실험에 기초한 준능동 제어 시스템 (Semi-Active Control System Based on the Experimental Results of the Performance of a Small Scale MR Damper)

  • 민경원
    • 한국전산구조공학회논문집
    • /
    • 제19권3호
    • /
    • pp.233-238
    • /
    • 2006
  • 이 논문에서는 소형 다층 구조물의 진동제어에 적용하기 위한 복합모드의 자기유변유체(MR) 감쇠기를 개발하였다. 우선, 도식적으로 전단, 유동, 복합모드 MR감쇠기의 형태를 설계조건과 함께 표현하였고, 각각의 모드에 대하여 자기장에 따른 감쇠력을 예측하기 위한 해석모델을 유도하였다. 다음으로 적당한 크기의 복합모드 MR감쇠기를 제작하고 자기장에 따른 감쇠특성을 시간영역에서 평가하였다. 마지막으로 지진하중을 받는 소형구조물에 제작된 MR감쇠기가 준능동 제어기로 제어하였을 때의 성능을 수치적으로 평가하였다.

Synthetic Computed Tomography Generation while Preserving Metallic Markers for Three-Dimensional Intracavitary Radiotherapy: Preliminary Study

  • Jin, Hyeongmin;Kang, Seonghee;Kang, Hyun-Cheol;Choi, Chang Heon
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.172-178
    • /
    • 2021
  • Purpose: This study aimed to develop a deep learning architecture combining two task models to generate synthetic computed tomography (sCT) images from low-tesla magnetic resonance (MR) images to improve metallic marker visibility. Methods: Twenty-three patients with cervical cancer treated with intracavitary radiotherapy (ICR) were retrospectively enrolled, and images were acquired using both a computed tomography (CT) scanner and a low-tesla MR machine. The CT images were aligned to the corresponding MR images using a deformable registration, and the metallic dummy source markers were delineated using threshold-based segmentation followed by manual modification. The deformed CT (dCT), MR, and segmentation mask pairs were used for training and testing. The sCT generation model has a cascaded three-dimensional (3D) U-Net-based architecture that converts MR images to CT images and segments the metallic marker. The performance of the model was evaluated with intensity-based comparison metrics. Results: The proposed model with segmentation loss outperformed the 3D U-Net in terms of errors between the sCT and dCT. The structural similarity score difference was not significant. Conclusions: Our study shows the two-task-based deep learning models for generating the sCT images using low-tesla MR images for 3D ICR. This approach will be useful to the MR-only workflow in high-dose-rate brachytherapy.

자기공명 영상을 이용한 피부 움직임 분석에 관한 연구 (Analysis of skin movement using MR images)

  • 류재헌;;;;이관행
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.719-722
    • /
    • 2003
  • This paper describes a novel experiment that measures the skin movement of a hand based on MR (magnetic resonance) images in conjunction with surface modeling techniques. The proposed approach consists of 3 phases: (1) MR scanning of a hand with surface makers, (2) 3D reconstruction from the MR images. and (3) registration of the 3D models. The results of registration are used to trace the skin movement with respect to underlying bone motions by measuring the positions of the surface markers.

  • PDF

LED MR16의 광효율 향상을 위한 비구면 광학계 연구 (A Study on Aspheric Optics Research for Improving the Luminous Efficiency of the LED MR16)

  • 유숙철;유경선;현동훈
    • 한국생산제조학회지
    • /
    • 제22권3호
    • /
    • pp.480-487
    • /
    • 2013
  • In this study, we researched the LED source MR16,which maintains the strong points of an ordinary MR16 while compensating for its weak points. The optical system composition of the LED MR16 includes four aspherical lens per sheet and a patterned reflector. The aspherical optical system and reflector were designed using optical software, and the performance was estimated using a lighting simulation program. Finally, a prototype was manufactured after analyzing the simulation data, and the reliability of the simulation results was estimated using a comparative analysis of the designed data and measured data.

An innovative hardware emulated simple passive semi-active controller for vibration control of MR dampers

  • Zhang, Jianqiu;Agrawal, Anil K.
    • Smart Structures and Systems
    • /
    • 제15권3호
    • /
    • pp.831-846
    • /
    • 2015
  • Magneto-Rheological (MR) dampers are being used increasingly because of their adaptability to control algorithms and reliability of passive systems. In this paper, an extensive investigation on performance of MR dampers in semi-active and passive modes has been carried out. It is observed that the overall energy dissipation by MR dampers in passive-on modes is higher than that in semi-active modes for most of the competitive semi-active controllers. Based on the energy dissipation pattern, a novel semi-active controller, termed as "Simple Passive Semi-Active Controller", has been proposed for MR dampers. This controller can be emulated by a simple passive hardware proposed in this paper. The proposed concept of controller "hardware emulation" is innovative and can also be implemented for other semi-active devices for control algorithms of certain form. The effectiveness and reliability of the proposed controller has been investigated extensively through numerical simulations. It has been demonstrated that the proposed controller is competitive to or more effective than other widely used / investigated semi-active controllers.

Effects of multiple MR dampers controlled by fuzzy-based strategies on structural vibration reduction

  • Wilson, Claudia Mara Dias
    • Structural Engineering and Mechanics
    • /
    • 제41권3호
    • /
    • pp.349-363
    • /
    • 2012
  • Fuzzy logic based control has recently been proposed for regulating the properties of magnetorheological (MR) dampers in an effort to reduce vibrations of structures subjected to seismic excitations. So far, most studies showing the effectiveness of these algorithms have focused on the use of a single MR damper. Because multiple dampers would be needed in practical applications, this study aims to evaluate the effects of multiple individually tuned fuzzy-controlled MR dampers in reducing responses of a multi-degree-of-freedom structure subjected to seismic motions. Two different fuzzy-control algorithms are considered, a traditional controller where all parameters are kept constant, and a gain-scheduling control strategy. Different damper placement configurations are also considered, as are different numbers of MR dampers. To determine the robustness of the fuzzy controllers developed to changes in ground excitation, the structure selected is subjected to different earthquake records. Responses analyzed include peak and root mean square displacements, accelerations, and interstory drifts. Results obtained with the fuzzy-based control schemes are compared to passive control strategies.