• 제목/요약/키워드: MR angiography

검색결과 154건 처리시간 0.025초

Investigation of the Characteristics of New, Uniform, Extremely Small Iron-Based Nanoparticles as T1 Contrast Agents for MRI

  • Young Ho So;Whal Lee;Eun-Ah Park;Pan Ki Kim
    • Korean Journal of Radiology
    • /
    • 제22권10호
    • /
    • pp.1708-1718
    • /
    • 2021
  • Objective: The purpose of this study was to evaluate the magnetic resonance (MR) characteristics and applicability of new, uniform, extremely small iron-based nanoparticles (ESIONs) with 3-4-nm iron cores using contrast-enhanced magnetic resonance angiography (MRA). Materials and Methods: Seven types of ESIONs were used in phantom and animal experiments with 1.5T, 3T, and 4.7T scanners. The MR characteristics of the ESIONs were evaluated via phantom experiments. With the ESIONs selected by the phantom experiments, animal experiments were performed on eight rabbits. In the animal experiments, the in vivo kinetics and enhancement effect of the ESIONs were evaluated using half-diluted and non-diluted ESIONs. The between-group differences were assessed using a linear mixed model. A commercially available gadolinium-based contrast agent (GBCA) was used as a control. Results: All ESIONs showed a good T1 shortening effect and were applicable for MRA at 1.5T and 3T. The relaxivity ratio of the ESIONs increased with increasing magnetic field strength. In the animal experiments, the ESIONs showed peak signal intensity on the first-pass images and persistent vascular enhancement until 90 minutes. On the 1-week follow-up images, the ESIONs were nearly washed out from the vascular structures and organs. The peak signal intensity on the first-pass images showed no significant difference between the non-diluted ESIONs with 3-mm iron cores and GBCA (p = 1.000). On the 10-minutes post-contrast images, the non-diluted ESIONs showed a significantly higher signal intensity than did the GBCA (p < 0.001). Conclusion: In the phantom experiments, the ESIONs with 3-4-nm iron oxide cores showed a good T1 shortening effect at 1.5T and 3T. In the animal experiments, the ESIONs with 3-nm iron cores showed comparable enhancement on the first-pass images and superior enhancement effect on the delayed images compared to the commercially available GBCA at 3T.

Diagnosis of Unruptured Intracranial Aneurysms Using Proton-Density Magnetic Resonance Angiography: A Comparison With High-Resolution Time-of-Flight Magnetic Resonance Angiography

  • Pae Sun Suh;Seung Chai Jung;Hye Hyeon Moon;Yun Hwa Roh;Yunsun Song;Minjae Kim;Jungbok Lee;Keum Mi Choi
    • Korean Journal of Radiology
    • /
    • 제25권6호
    • /
    • pp.575-588
    • /
    • 2024
  • Objective: Differentiating intracranial aneurysms from normal variants using CT angiography (CTA) or MR angiography (MRA) poses significant challenges. This study aimed to evaluate the efficacy of proton-density MRA (PD-MRA) compared to high-resolution time-of-flight MRA (HR-MRA) in diagnosing aneurysms among patients with indeterminate findings on conventional CTA or MRA. Materials and Methods: In this retrospective analysis, we included patients who underwent both PD-MRA and HR-MRA from August 2020 to July 2022 to assess lesions deemed indeterminate on prior conventional CTA or MRA examinations. Three experienced neuroradiologists independently reviewed the lesions using HR-MRA and PD-MRA with reconstructed voxel sizes of 0.253 mm3 or 0.23 mm3, respectively. A neurointerventionist established the gold standard with digital subtraction angiography. We compared the performance of HR-MRA, PD-MRA (0.253-mm3 voxel), and PD-MRA (0.23-mm3 voxel) in diagnosing aneurysms, both per lesion and per patient. The Fleiss kappa statistic was used to calculate inter-reader agreement. Results: The study involved 109 patients (average age 57.4 ± 11.0 years; male:female ratio, 11:98) with 141 indeterminate lesions. Of these, 78 lesions (55.3%) in 69 patients were confirmed as aneurysms by the reference standard. PD-MRA (0.253-mm3 voxel) exhibited significantly higher per-lesion diagnostic performance compared to HR-MRA across all three readers: sensitivity ranged from 87.2%-91.0% versus 66.7%-70.5%; specificity from 93.7%-96.8% versus 58.7%-68.3%; and accuracy from 90.8%-92.9% versus 63.8%-69.5% (P ≤ 0.003). Furthermore, PD-MRA (0.253-mm3 voxel) demonstrated significantly superior per-patient specificity and accuracy compared to HR-MRA across all evaluators (P ≤ 0.013). The diagnostic accuracy of PD-MRA (0.23-mm3 voxel) surpassed that of HR-MRA and was comparable to PD-MRA (0.253-mm3 voxel). The kappa values for inter-reader agreements were significantly higher in PD-MRA (0.820-0.938) than in HR-MRA (0.447-0.510). Conclusion: PD-MRA outperformed HR-MRA in diagnostic accuracy and demonstrated almost perfect inter-reader consistency in identifying intracranial aneurysms among patients with lesions initially indeterminate on CTA or MRA.

대동맥-상대정맥루를 동반한 A형 대동맥 해리증 수술 치험 -1례보고- (Type A Aortic Dissection with Aortocaval Fistula -Report of 1 case-)

  • 김흥수;양승인;정성운;김종원;이형렬
    • Journal of Chest Surgery
    • /
    • 제35권8호
    • /
    • pp.599-604
    • /
    • 2002
  • 급성 혹은 만성 대동맥 해리증은 파열을 일으킬 수 있는데 이는 사망의 주요 원인이 된다. 상행대동맥의 해리성 동맥류(Stanford A형 대동맥 해리증)는 극히 드물게 상대정맥으로 파열되어 대동백-상대정맥루를 형성할 수 있는데 대동백-하대정맥루는 복부 대동맥류 환자에서 이따금씩 보고되어 왔다. 최근 상대정맥증후군의 증상을 가진 67세 남자환자에서 CT, MR angiography, 동맥촬영 등 방사선학적 검사결과 Stanford A형 대동맥 해리증 및 대동맥-상대정맥루가 진단되었다. 해리된 동맥류는 절제 후 인조혈관으로 치환되었고 대동맥-상대정맥루는 초저온 순환정지 상태에서 교정되었다. 이에 대해 상세하게 기술하는 바이다.

Spontaneous Intraorbital Hemorrhage : A Case Report

  • Kwon, Jae-Hyun;Song, Young-Jin;Choi, Sun-Seob;Kim, Ki-Uk
    • Journal of Korean Neurosurgical Society
    • /
    • 제44권3호
    • /
    • pp.156-158
    • /
    • 2008
  • Intraorbital hemorrhage is a rare clinical condition caused by orbital trauma, surgery around the orbit, intraorbital vascular abnormalities, and neoplasm. It was reported to occur spontaneously without any known causes and in association with orbital pseudotumor in a very few cases. A 59-year-old, female patient admitted with sudden onset of severe exophthalmos and pain on the left eye. Orbital CT and MR imaging suggested hemorrhage in the upper part of retrobulbar area of the left orbit. Cerebral angiography was taken to rule out any possible vascular abnormalities. On the left carotid cerebral angiography, the run-off of the distal ophthalmic artery was not seen and the engorgement of the supraophthalmic artery was noted. Systemic administration of corticosteroid did not improve the clinical status and craniectomy was done and retrobulbar hematoma was removed, and the clinical symptoms and signs were improved. Authors report a case of spontaneous intraorbital hemorrhage with the clinical features similar to those of orbital pseudotumor, requiring surgical decompression.

MR Line Scan Angiography using Spectral Analysis

  • Jung, Kwan-Jin;Ro, Yong-Man;Sim, Bog-Tae;Ra, Jong-Beom;Cho, Zang-Hee
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1989년도 춘계학술대회
    • /
    • pp.27-28
    • /
    • 1989
  • In conventional line scan angiography, flow signal has been enhanced by the time_of_flight effect while the signal from stationary tissues has been suppressed by the saturation rf pulse followed by spoiling gradients. Due to the inhomogeneous rf field and the tissue dependent T1 relaxation time, however, stationary tissues can not be suppressed completely or uniformly, and the remnant stationary signal deteriorates the resultant angiogram. Here, the complete cancellation of stationary tissues is made possible by the spectral analysis of a series of repetitive line images of the same slice. The Fourier transformation of a set of line images results in the spectrum images, where stationary tissues are collected into the dc component while arteries are included in harmonic components because of the variation of the flow velocity and the resultant flow signal in arteries according to the cardiac cycle. The summation of harmonic components excluding the dc component results in the angiogram of arteries with the complete cancellation of stationary tissues.

  • PDF

골연골종에 의한 슬와동맥 압박: 도플러 초음파의 유용성 (Popliteal Arterial Compression Caused by Osteochondroma: Usefulness of Doppler Ultrasonography)

  • 정웅교;김호중;이순혁
    • 대한정형외과 초음파학회지
    • /
    • 제3권2호
    • /
    • pp.69-73
    • /
    • 2010
  • 슬관절 주변부에 발생한 골연골종은 간혹 혈관 합병증을 동반하기도 한다. 혈관 합병증을 진단하기 위해 혈관 조영술이 보편적으로 사용되고 있으나 침습적 검사라는 단점이 있고 최근에는 비침습적 검사로 자기공명 혈관 조영술이 이용되기도 하나 고가의 검사라는 제한점이 있다. 저자들은 원위 대퇴골에 발생한 골연골종에 의해 슬와동맥이 압박되었던 20세 남자를 도플러 초음파를 사용하여 진단 및 치료결과를 평가하였기에 문헌고찰과 함께 도플러 초음파의 유용성을 보고하고자 한다.

  • PDF

혈액투석 환자에서 발생한 중심 정맥 협착의 혈관성형술 후 호전된 대뇌 정맥 고혈압: 증례 보고 (Resolved Cerebral Venous Hypertension after Angioplasty of Central Venous Stenosis in a Hemodialysis Patient: A Case Report)

  • 강희민;박성태
    • 대한영상의학회지
    • /
    • 제83권1호
    • /
    • pp.206-211
    • /
    • 2022
  • 혈액투석 환자에서 중심정맥 협착은 비교적 흔한 합병증이다. 하지만 중심정맥 협착으로 인해 대뇌 정맥 고혈압과 이로 인한 신경학적 증상이 발생하는 것은 비교적 드물다. 중심정맥협착으로 인해 발생한 좌측 내경정맥으로부터의 역행성 혈류로 대뇌 정맥 고혈압이 발생한 63세 남성의 증례를 보고하고자 한다. 환자는 중심정맥 협착에 대한 치료를 받은 후 증상 및 치료 전 자기공명영상에서 역행성 혈류를 의미하는 time-of-flight 신호가 소실되었다.

조영증강 전산화단층촬영술을 이용한 두경부 조영증강 삼차원 자기공명혈관촬영술에서 내경정맥 폐쇄의 원인 평가 (Evaluation of the Cause of Internal Jugular Vein Obstruction on Head and Neck Contrast Enhanced 3D MR Angiography Using Contrast Enhanced Computed Tomography)

  • 권혜미;정태섭;서상현
    • Investigative Magnetic Resonance Imaging
    • /
    • 제15권1호
    • /
    • pp.41-47
    • /
    • 2011
  • 목적: 조영 증강 삼차원 자기공명혈관촬영술에서 관찰되는 내경정맥 폐쇄의 원인을 조영 증강 전산화단층촬영술을 이용하여 분석하고자 한다. 대상과 방법: 2005년부터 2008년까지 두경부 조영증강 자기공명혈관조영술과 조영증강 전산화단층촬영술을 함께 시행한 30명의 환자를 대상으로 하였다. 조영증강 자기공명혈관조영술에서 내경정맥의 폐쇄가 있는 경우 폐쇄군으로 하였고 내경정맥의 폐쇄가 없는 경우 대조군으로 구분하였다. 다음의 지표를 조영증강 전산화단층촬영술에서 분석하였다 : 1) 내정정맥의 직경; 2) 경상돌기와제일경추의 외측돌기와의 거리; 3) 제일경추의 외측돌기의 최대넓이 이후 각각의 지표를 폐쇄군과 대조군에서 비교하였다. 결과: 폐쇄군에서 내경정맥의 직경 그리고 정상돌기와 제일경추의 외측돌기와의 거리는 각각 $1.6{\pm}1.0\;mm$ 그리고 $4.1{\pm}2.1\;mm$로 평가되었으며 이는 대조군과 비교하여 유의하게 작게 분석되었다 (p < 0.01). 폐쇄군에서 제일경추의 외측돌기의 최대 넓이는 $103.4{\pm}25.3\;mm^2$로 평가되었으며 이는 대조군과 비교하여 유의하게 넓은 것으로 나타났다 (p < 0.05). 결론: 조영증강 자기공명혈관촬영술에서 보이던 대경정맥 폐쇄의 원인은 제일경추의 비대칭적인 큰 넓이에 의한 것 일수 있다.

자기공명영상을 이용한 찜질 자극에 의한 통증 완화 효과에 대한 혈류 영상학적 고찰 (The Study of Vascular Dynamics for the Effect of a Compress Pack on Pain Relief using Magnetic Resonance Angiography)

  • 백지원;임영기
    • Journal of Radiation Protection and Research
    • /
    • 제40권4호
    • /
    • pp.277-282
    • /
    • 2015
  • 본 연구는 찜질 자극이 국소 통증을 완화시킬 뿐만 아니라 편두통과 같은 만성 질환의 통증 완화에 효과적으로 애용되고 있는 이유에 대한 근거를 혈류 역학적인 측면에서 고찰하고자 한다. 이를 위해 찜질 자극에 의한 자극 부위에서의 국소 혈류 변화가 일어나는 것을 관측하고, 이를 통해 두개 내 외부의 혈액 순환에 어떠한 변화를 야기하는지를 정상인 피험자 (n=8, 평균나이: $32.13{\pm}4.61$) 를 대상으로 자기공명영상 시스템을 이용하여 관측하였다. 국소 혈류변화는 찜질 자극에 의한 피부 색깔 및 온도 변화를 통하여 관측하고자 하였고, 두개 내 외부 혈관의 자극에 따른 변화를 자기공명혈관조영술을 통해 관측하고 영상을 분석하여 비교하고자 하였다. 찜질 자극 전 $36.4^{\circ}C$에서 자극 15분 후 $36.7^{\circ}C$, 그리고 자극 30분 후 $37.1^{\circ}C$ 로 피부온도가 상승한 것으로 나타났으며, 찜질 자극이 시작되는 시점과 자극 30분 후의 혈관 영상 분석 결과를 살펴보면 두개 내부 혈관에서는 유의한 변화를 보이지 않은 반면, 두개 외부 혈관에서는 찜질 자극 후 상당한 혈류 신호의 변화를 보여주었다(+38.8%). 결과에서 보듯이 찜질 자극 부위의 이러한 국소 온도의 변화와 두개 외의 혈류의 변화를 통하여 찜질 자극이 국소적으로는 근육 통증 및 편두통과 같은 만성질환의 통증을 완화시키는 효과를 발휘하고 더 나아가 혈액 순환을 촉진시키는 작용을 통하여 전신에 미치는 결림 현상 및 통증의 완화에 실질적으로 효과를 보일 수 있게 되는 것으로 사료된다.

자기공명혈관조영술로 진단된 제2형 전환추동맥(Proatlantal Artery): 증례 보고 (Persistent Proatlantal Artery in Magnetic Resonance Angiography: A Case Report)

  • 전성우;장혁원;김미정;조지형
    • Investigative Magnetic Resonance Imaging
    • /
    • 제17권1호
    • /
    • pp.55-58
    • /
    • 2013
  • 전환추동맥은 드물게 보고된 태생기 경-기저동맥문합 잔류동맥의 하나이다. 태생 3주경에 발생하는 경-기저동맥문합은 삼차동맥, 귀동맥, 설하동맥, 그리고 전환추동맥으로 이루어지며, 정상인에서는 태생 6주경 전환추동맥을 마지막으로 모두 퇴화된다. 일반적으로 전환추동맥은 주로 내경동맥에서 기원하며 경추 가로돌기구멍을 통과하지 않는 제1형과, 외경동맥에서 기원하여 첫째 경추 가로돌기구멍을 통과하는 제2형으로 나뉘며, 임상적인 증상을 일으키는 경우는 드물다. 그러나 비교적 잘 동반되는 척추동맥의 무형성을 포함한 두개강내 동맥기형이 있을 수 있으며, 이는 경동맥 내막 절제술 및 외경동맥 색전술 등의 시술시 의의가 있어 심도 있는 이해가 필요하다. 이에 저자들은 자기공명혈관조영술로 진단된 제2형 전환추동맥 증례보고와 문헌고찰을 하고자 한다.